Installation notes
DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388
E-mail: [email protected] Web: www.danlers.co.uk
Company Registered Number 2570169 VAT Registration Number 543 5491 38
Products available from DANLERS
• PIR occupancy switches • Daylight linked dimmers • Manual high frequency dimmers
• Photocells • Radio remote controls • Time lag switches • Outdoor security switches
• Dimmers • Heating, ventilation and air-conditioning controls • Bespoke / O.E.M. products
Please call for more information or a free catalogue, or visit our website.
This product conforms to BS EN 60669-2-1, BS EN 55015 and BS EN 60730.
Please ensure the most recent edition of the appropriate local wiring regulations are observed
and suitable protection is provided (protected with the appropriate MCB) 1kV over voltage.
Please ensure that this device is disconnected from the supply if an insulation test is made.
This product is covered by a warranty which extends to 5 years from the date of manufacture.
Precautions and Warranty
08/09/16 INS332 EZ CEFL
Variants
DANLERS design and manufacture other EasyZAPP Ceiling Flush Mounted
variants, coded by the following order codes:
EZ CEFL 10VDC Suitable for 1-10VDC ballasts
EZ CEFL DALI Suitable for DALI ballasts
Troubleshooting
The load will not switch on:
•TheLUXsettingasspeciedbytheEasyZAPPAppissettoolowandisinhibiting
the switch.
• The moving body is not emitting more IR than the background.
(Person wearing insulating clothing in a warm environment)
• Person is too far from the PIR switch, see detection diagram.
• Person is moving unusually slowly (perhaps when testing).
• The control unit battery is not engaged (ON).
Switch RED dip switch next to the telejack connector on the control
unit to the DOWN position.
The load switches on when nobody is present:
• Heater causing infra-red variations in a small cold room.
Resite the EZ CEFL control away from heater.
• Please contact DANLERS for further technical support.
 EasyZAPPCeilingushmountedswitches
EZ CEFL
EasyZAPPceilingushmountedmultifunctionaldevicescanbeushmountedinto
suspended and plasterboard ceilings (diagram A). EasyZAPP devices incorporate
a passive infra-red quad sensor to detect movement of a warm body within their
detection zone (diagram B) and a photocell to monitor the ambient light level.
PleaseNote:ALLadjustmentsaremadeviaafreelydownloadableEasyZAPP
AppavailablefromtheDANLERSwebsite.EasyZAPPproductscannotbe
conguredbyDANLERSControlZAPPorScheduleZAPPapps.
Upon detecting movement, if the ambient light is dark enough, the EasyZAPP device
will turn the load ON. The ambient threshold can be set to between approximately
30luxto1000luxandinnitelux(photocellinactive)viathe‘Brightness’settingson
the EasyZAPP App. If no more movement is detected within a pre-selected time as
determined by the EasyZAPP App, then the EasyZAPP device will turn the load off.
This‘Timeout’ortimelagcanbesetviatheEasyZAPPAppadjusterbetween10sec
and 23hrs 59min 59sec.
Loading
EZ CEFL is suitable for mains switching or DALI switching only.
EZ CEFL can switch up to:
• 10 amps (3000W) of resistive loads
• 6amps(1500W)uorescentlamps,highfrequencyorswitchstart,
incandescent or mains halogen lamps (recommended with integral safety fuse)
• 3 amps (750W) of electronic or wire wound transformers.
• 2 amps (500W) of low energy lamps: CFL, LED, 2D etc.
• 1 amp (250W) of fans or most metal halide lamps.
Start-upmodeandDefaultsettings
When the EZ CEFL is powered up, it will take 1 minute for the circuitry to stabilise
(detectionLEDashing)andensuretheoutputisoff,theEasyZAPPdevicewillthen
enter its Default Operating Mode.
Please Note: When in the Default Operating Mode the EZ CEFL is set up as an
occupancy switch with a 20 minute turn OFF timeout (time lag) and photocell
disabled.
Installation procedure
1. Please read these notes carefully before commencing work. In case of doubt
pleaseconsultaqualiedelectrician.Ensurewiresandcablesaresecurelyheld
within the connection terminals.
 IMPORTANT:TheEZCEFLControlUnitclockbatterymustbeengaged(ON)
priortoinstallationbyswitchingtheREDdipswitch(seediagramE)tothe
DOWNposition.
2. POSITIONING: The EZ CEFL switch should be installed to achieve correct
coverage of the area, see diagram B.
If the photocell override facility (enabled
via EasyZAPP app) is required, the switch must be located above an area where
daylightcangivegreaterilluminationthanthearticiallight.Avoidlocatingthis
product where it is exposed to drafty conditions (exposed lobbies, open ceiling
voids or near fans) or near heat sources. To cover large areas PIRs should be
spaced in a 5 metre grid formation.
3. Disconnect the PIR from the circuit before performing insulation testing of the
wiring circuit.
4. Do not connect on a circuit with large inductive loads, as induced spikes may
cause false triggering or damage the PIR.
5. EZ CEFL must be connected to the EasyZAPP Power Supply (CZPS) via the
EasyZAPP communication cable provided, for wiring see diagrams C and D.
NOTE: The use of non EasyZAPP connectors may damage the
EZ CEFL or CZPS and will invalidate the warranty.
Settingsandcalibration
ALL settings are adjusted by EasyZAPP App as detailed in the free to download
EasyZAPP App User Guide, including:
Timeout: Adjustable time lag from 10 seconds to 24 hours.
Brightness: Adjustable switching threshold, 30 to 1000 lux and inactive.
EZ CEFL must be calibrated as instructed on the user guide manual.
BatchCongure:ForconguringmultipleEZCEFLcontrolswithidenticalsettings.
Name:For identifying individual controls.
Password: For security against accidental or malicious alteration.
Please visit www.danlers.co.uk to download the EasyZAPP user guide.
B:Detectiondiagram
up to 5m
up to 7m
Strong detection zone
i.e. person moving arm
or walking towards PIR Secondary detection
zone i.e. person
walking perpendicular
to PIR
For optimum coverage
recommended
mounting height: 2.4 to 5m
SL
L
L
N
Telejack connector Control Unit
Power Supply
Red dip switch (MUST be
switched DOWN (towards lens)
to engage clock battery ON)
IMPORTANT
E:Connectordiagram
A:Mountingdiagram
CEILING VOID
(At least 78mm deep)
75mm circular hole
cut for PIR switch
L
load
N
100 - 260 VAC
50 / 60 Hz
L
N
SL
L
load
N
100-260 VAC
50 / 60 Hz
L
N
SL
L
N
SL
L
N
SL
Several EZ CEFL wired in parallel
Single EZ CEFL
L
load
N
100 - 260 VAC
50 / 60 Hz
L
N
SL
L
load
N
100-260 VAC
50 / 60 Hz
L
N
SL
L
N
SL
L
N
SL
Several EZ CEFL wired in parallel
Single EZ CEFL
C:Wiringdiagram D:Wiringdiagram

Other DANLERS Switch manuals

DANLERS CZ CEFL Quick start guide

DANLERS

DANLERS CZ CEFL Quick start guide

DANLERS CESRA PIR DSIP Quick start guide

DANLERS

DANLERS CESRA PIR DSIP Quick start guide

DANLERS CESFPIRSV Quick start guide

DANLERS

DANLERS CESFPIRSV Quick start guide

DANLERS TWSW Quick start guide

DANLERS

DANLERS TWSW Quick start guide

DANLERS CESF PIR Quick start guide

DANLERS

DANLERS CESF PIR Quick start guide

DANLERS CESRAPIRSD Quick start guide

DANLERS

DANLERS CESRAPIRSD Quick start guide

DANLERS ControlZAPP CZ CEFL 10VDC Quick start guide

DANLERS

DANLERS ControlZAPP CZ CEFL 10VDC Quick start guide

DANLERS WACEPIR Quick start guide

DANLERS

DANLERS WACEPIR Quick start guide

DANLERS CESF PIR User manual

DANLERS

DANLERS CESF PIR User manual

DANLERS CESF PIR User manual

DANLERS

DANLERS CESF PIR User manual

DANLERS CEFLA PIR DSIP Quick start guide

DANLERS

DANLERS CEFLA PIR DSIP Quick start guide

DANLERS TLSW 10 ILM Quick start guide

DANLERS

DANLERS TLSW 10 ILM Quick start guide

DANLERS BMPIR10M Quick start guide

DANLERS

DANLERS BMPIR10M Quick start guide

DANLERS ControlZAPP CZ CEFL Quick start guide

DANLERS

DANLERS ControlZAPP CZ CEFL Quick start guide

DANLERS CESF PIR IP66 Quick start guide

DANLERS

DANLERS CESF PIR IP66 Quick start guide

DANLERS ControlZAPP CZ CEFL DALI Quick start guide

DANLERS

DANLERS ControlZAPP CZ CEFL DALI Quick start guide

DANLERS ControlZAPP CZ CESR 10VDC Quick start guide

DANLERS

DANLERS ControlZAPP CZ CESR 10VDC Quick start guide

DANLERS DUSW Quick start guide

DANLERS

DANLERS DUSW Quick start guide

DANLERS CEFLA PIR DALIP Quick start guide

DANLERS

DANLERS CEFLA PIR DALIP Quick start guide

DANLERS GRTLA MK Quick start guide

DANLERS

DANLERS GRTLA MK Quick start guide

DANLERS CEFLAPIR Quick start guide

DANLERS

DANLERS CEFLAPIR Quick start guide

DANLERS CESPLL10VDC Quick start guide

DANLERS

DANLERS CESPLL10VDC Quick start guide

DANLERS CESRA PIR 10VDC Quick start guide

DANLERS

DANLERS CESRA PIR 10VDC Quick start guide

DANLERS COPIR IP66 User manual

DANLERS

DANLERS COPIR IP66 User manual

Popular Switch manuals by other brands

Edimax GS-5008E manual

Edimax

Edimax GS-5008E manual

Bogen CA-10 datasheet

Bogen

Bogen CA-10 datasheet

Planet GSW-1601 user manual

Planet

Planet GSW-1601 user manual

SALZ 2008GT Quick installation guide

SALZ

SALZ 2008GT Quick installation guide

ATEN VanCryst VS481A user manual

ATEN

ATEN VanCryst VS481A user manual

EnGenius EWS2910P user guide

EnGenius

EnGenius EWS2910P user guide

CYP CDPS-U42HPIP Operation manuals

CYP

CYP CDPS-U42HPIP Operation manuals

KSR KUEBLER BGU D Series operating instructions

KSR KUEBLER

KSR KUEBLER BGU D Series operating instructions

NETGEAR ProSafe GS700TP Software administration manual

NETGEAR

NETGEAR ProSafe GS700TP Software administration manual

Altusen KM0832 quick start guide

Altusen

Altusen KM0832 quick start guide

TP-Link TL-SL5428E user guide

TP-Link

TP-Link TL-SL5428E user guide

D-Link DES-1210/ME Series manual

D-Link

D-Link DES-1210/ME Series manual

RFL Electronics RFL 9660 instruction manual

RFL Electronics

RFL Electronics RFL 9660 instruction manual

EUCHNER NZ H Series operating instructions

EUCHNER

EUCHNER NZ H Series operating instructions

TP-Link TL-RP108GE installation guide

TP-Link

TP-Link TL-RP108GE installation guide

Panasonic AJ9 (J9) installation instructions

Panasonic

Panasonic AJ9 (J9) installation instructions

Edge-Core ES3628EA user manual

Edge-Core

Edge-Core ES3628EA user manual

Exsys EX-1185HMVS-2 manual

Exsys

Exsys EX-1185HMVS-2 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.