3. Place a small quantity of solvent in
the cup. Reconnect air supply to gun.
Spray solvent until clean.
Certain environmental legis-
lation prohibits spraying sol-
vents into the atmosphere.
Check local codes.
Air Supply Requirements:
• 18 SCFM at 10 PSIG air cap pressure
(33A air cap)*
• 22.5SCFMat10PSIGaircappressure
(#46MPaircap)*
• 26.0SCFMat10PSIGaircappressure
(#83MPaircap)*
• Minimum 5/16" inside dia. air hose
1. TurnA all the way.
2. PulltriggerandturnB
untilthetriggertouchesthehandle.
3. TurnDall the way.
4. Fillcupwithpaint.Connectairhose.
Performthefollowingstepsandprac-
ticeonapieceofcardboard.
5. Adustairpressuretogunhandle,cor-
respondingwithrequiredbaferange:
JGHV-450-28or33-80=80psimaximum
JGHV-450-28or33-50=50psimaximum
JGHV-450-46-50=50psimaximum
JGHV-450-83-65=65psimaximum
Theseinputpressuresresultin10psi
air cap pressure. Use only as much
atomizing air required to properly
atomize.Verifypressureatcapusing
KK-5033-28,33A46MPor83MPaircap
test kit.
6. Whiletriggeringthegun,very slowly
turn D toincreaseuid
pressure.
7. Iftoomuchpaintisbeingsprayed,turn
DallthewayandpushdownC
to remove all cup pressure. Repeat Step
No. 6 at lower pressure.
CLEANING GUIDE
GunwashersdonotadequatelycleanHVLP
gunsandcups.Thesolventspraymustbe
directedatcriticalareassuchasthecheck
valveandpoppet.Asmallsqueezebottle
lledwithsolventisusefulforcleaning
these areas.
Ifagunwasherisused,besuretoremove
regulator Dfromgunbeforeplacinggun
assemblyinwasher.Do not put regulator
or gauge in gun washer.
Service Bulletin
SB-2-009-D
QUICK START AND CLEANING GUIDE
JGHV Spray Gun with TLC-576 or TSC-591 Cup
Read this before you attach the air hose!
Cleaning Procedures
1. Disconnectspraygunfromairsupply.
2. Removecupandemptypaint,wipelid
clean,uidtubeandinsideofcup.
The paint cup is pressurized.
Press the poppet C to release
all cup pressure before open-
ing the cup.
ReplacesSB-2-009-C
*SCFM=Standardcubicfeetperminute(airvolume)
*PSIG=Poundspersquareinchgauge(airpressure)
C Poppet
A Fan
Adjustment
B FluidNeedle
Adjustment
D FluidPressure
Adjustment