© 2007 ITW Finishing Systems and Products 7
E
Preventative Maintenance
1. Turn off air supply and relieve pressure in the airline or, if using QD system, disconnect from
airline.
2. Empty coating material into a suitable container and clean the gun and cup, preferably in a
gun wash machine.
3. IMPORTANT– the cup must not be cleaned or rubbed with a dry cloth or paper. It is
possible to generate a static charge by rubbing which, if discharged to an earthed
object could create an incendive spark and cause solvent vapours to ignite. Only use
a dampened cloth or antistatic wipes if additional cleaning is required within a
hazardous area.
4. Remove air cap and clean. If any of the holes in the cap are blocked with coating material,
use a toothpick to clean. Never use metal wire which could damage the cap and produce
distorted spray patterns
5. Ensure the tip of the nozzle is clean and free from damage. Build-up of dried paint can
distort the spray pattern.
6. Lubrication– stud/screw (6), needle (7) and air-valve (11) should be oiled each day.
Replacement of Parts
Nozzle (2) and needle (7) – Remove parts in the following order: 10, 8, 7, 1 and 2. Replace any
worn or damaged parts and re-assemble in reverse order. Recommended tightening torque for
nozzle (2) 17-20 Nm (150-180 lbf in)
Packing – Remove parts 10, 8, 7. Unscrew cartridge (4). Fit new cartridge finger tight. Re-
assemble parts 7, 8, and 10 and tighten cartridge (4) with spanner sufficient to seal but to allow
free movement of needle. Lubricate with gun oil.
Air-Valve – Remove parts (6) and (12). Unscrew valve assembly. Re-assemble, fitting spring to
valve head.
Spreader Valve – Caution: always ensure that the valve is in the fully open position by turning
screw fully counter-clockwise before fitting to body.
Air cap / Nozzle selection
Refer to coating material manufacturers recommendations or ITW Finishing UK Website:
www.itweuropeanfinishing.com
Accessories
Spanner – order SPN-5
Cleaning brush – order 4900-5-1-K3
GFC-511 – Gravity cup, polyester for use with sulphuric acid based primers
Service kit – order KK-4502 add nozzle size and material code as required (e.g. KK-4502-FF-
H)
Service kit – order KK-4558
Mini service kit – order KK-4503
Pressure gauge attachment – order GA-515
Gun mounted regulator – order DVR-501
Lubricant – order GL-1-K10