13
I. Decorative Cover Installation
Installing unit with 3105007.XXX or 3105935.XXX
ReturnAir Cover. For Genesis Air Filtration system
Return Air Kit See Page 14.
Note: On models equipped with a solar panel, see wiring
instructionsforthe solar panelbefore proceeding.
1. Removethereturnairgrill from the return aircover.
2. Place the return air cover up to the ceiling tem-
plate.
Installation (Installing unit with 3308120.XXX
Genesis Filtration System Return Air Kit)
c. Connectthepreviouslyrunfurnacethermostat
wires(ifapplicable)tothebluewiresprotruding
fromthereturnairopening.Thepolarityofthese
connections does not matter.
d. Connect the previously run Energy Manage-
mentSystemwires(ifapplicable)totheyellow
wiresprotrudingfromthereturnairopening.The
polarity of these connections does not matter.
e. Terminatethe4-conductorcontrolcable(s)pro-
truding into the 14-1/4" x 14-1/4" (±1/8") roof
opening.Thecable(s)mustbeterminatedwith
atelephoneRJ-11connector.Refertothecrimp
toolmanufacturerforcrimpinginstructions.
Important: RJ-11 connectors must be installed as
shown in FIG. 6A & 6C.
f. Plug the control cable(s) into the telephone
jack(s) protrudingfromthereturnairopening.(It
doesnot matterwhich one.)
2. ConnectionOf115VoltPowerSupply
Disconnect115 voltAC. Failure to follow these
instructions could create a shock hazard
causing death or severe personal injury.
a. Route power supply line through Romex con-
nectorinto junctionbox on sideaway from the
ceilingtemplate.Tightenconnector.
b. Connect white to white; black to black; and
greentogreenorbarecopperwireusingappro-
priate sized twist connectors.
c. Tape the twist wire connectors to the supply
wireto assuretheydon'tvibrateoff.
d. Push the wires into the box.
e. Install the cover onto the junction box.
Improper installation and sealing of foam di-
viderwillcausethecompressortoquickcycle
onthe cold control. This may result in fuseor
circuit breaker opening and/or lack of cool-
ing.
CAUTION
e. Cut the opening in the center duct using the
dischargeopeninginthe ceiling template fora
pattern.Seal the center duct to the ceiling tem-
plateusing foil tape,foam insulation orsilicon
sealant.
620515, 620525, 620526, 630515 & 630516 Installation Instructions
d. Use Aluminum foil tape (not supplied) to seal
theendsof the foamdivider tothesidesof the
opening.Make sure the areabehindtheflange
ontheceiling template issealed.SeeFIG.23.
H. Wiring Of System
Reachup intothereturnairopeningand pull theremaining
wiresdown.
1. ConnectionOfLowVoltageWires
Disconnect the positive (+) 12 volt DC termi-
nal at the supply battery. Damage to equip-
ment could occur if the 12 volt DC is not shut
off.
a. RouteRemoteTemperatureSensorcable,if
applicable, and attach it to the connector that
matchesitscolorprotrudingfromthereturnair
opening.
b. Connect the previously run 12 VDC to the red
and black wiresprotruding fromthe unitreturn
airopening.(Inmultiplezoneinstallations,this
needstobe doneat only one zone.) Connect
+12VDCtothe redwire;–12VDCtotheblack
wire. (Do not connect wires if using the
3308120.XXX Genesis Air Filtration System
ReturnAirKit.)SeeSectionIDecorativeCover
CAUTION
AC Power
Supply
Pull Electrical
Cord Down
Center Unit From Below
Roof
Gasket
FIG. 26
DC Power
Supply
CCC
Leads
Remote
Sensor
Furnace
This product is equipped with a 3-wire
(grounded) system for protection against
shock hazard. Make sure that the product is
wired into a properly grounded 115 volt AC
circuitandthepolarityiscorrect.Failuretodo
so could result in death, personal injury or
damage to the equipment.