1
01
Door Preparation
Draw the center line of the device across the door and frame at
40 5/16” (1024) above the floor.
A. If door has preparation for 2 3/4” (70) backset cylindrical
lock, mount panic strike using center of 2 1/8” (54) diameter
lock hole.
B. If your door has cylindrical lock cut-out for ANSI A115.2 and
A115.3 prep doors:
B1. Extend horizontal and vertical center lines of cut-out
shown at right.
B2. If frame has 5/8” (16) stop, align center lines on template
with center lines on door. Drill template holes as
described above and follow steps three thru seven.
B3. If frame has 1/2” (12.7) stop, align center lines on
template with center lines on door and spot mounting
holes for latch assembly only. Then move template up
against stop and spot mounting holes for strike. Drill two
mounting holes. Now follow steps three thru six.
Note special shim shown at right, which is mounted
beneath strike.
02
Lock and Drill template Holes:
Locate and drill mounting holes for trim, device and strike using
furnished template.
Dim Inside ( ) are in mm
dormakaba ED22
ED22 Rim Exit Device
Installation Instruction - Reversible (Non Handed)
Twist Drill Sizes
Screw
Diameter
*Machine
Screws Self Tapping Screws
All Door
Gauges GA GA GA GA
# # (.) /” (.) /” (.) # (.) # (.)
# # (.) # (.) # (.) # (.) # (.)
Screw Chart
Item Q’ty Fastener
Front plate assembly and
rear bracket # x /” Lg. pan head tapping
screws type “A”
Strike # x /” Lg. pan head tapping
screws type “A”
Edge Filler #- x /” machine screw,
# x ” pan head tapping scew
Strike Filler #- x /” flat hd. machine screw,
# x /” pan hd tapping scew
*Machine screws are intended for use with doors having
sufficent metal thickness for proper tapping (reinforced doors)
or sex bolts.
Drill sizes for screws are recommended but various factors, such
as type of door and frame construction, thickness and type of
metal, etc, can affect the final hole diameter and resulting
holding strength of the fastener.