RFSA-62B
Wireless switch unit
EN
02-49/2015 Rev.1
5/5
Technical parameters /
Supplyvoltage:
Apparent input:
Dissipated power:
Supplyvoltagetolerance:
Output
Number of contacts:
Rated current:
Switching power:
Peak current:
Switching voltage:
Max.DC switching power:
Mechanical service life:
Electrical service life(AC1):
Control
RF, by command from transmitter:
Manual control:
Rangein free space:
Other data
Operating temperature:
Operating position:
Mounting:
Protection:
Overvoltagecategory:
Contamination degree:
Terminals(CY wire, cross-section):
Length of terminals:
Dimensions:
Weight:
Related standards:
Warning
Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing.
Installation and connection can be carried out only by a person with adequate professional qualification upon
understanding this instruction manual and functions of the device, and while observing all valid regulations.
Trouble-free function of the device also depends on transportation, storing and handling. In case you notice any
sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It
is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before starting
installation, make sure that all wires, connected parts or terminals are de-energized. While mounting and servicing
observe safety regulations, norms, directives and professional, and export regulations for working with electrical
devices. Do not touch parts of the device that are energized – life threat. Due to transmissivity of RF signal, observe
correct location of RF components in a building where the installation is taking place. RF Control is designated only
for mounting in interiors. Devices are not designated for installation into exteriors and humid spaces. The must not
be installed into metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is
then impossible. RF Control is not recommended for pulleys etc. – radiofrequency signal can be shielded by an
obstruction, interfered, battery of the transceiver can get flat etc. and thus disable remote control.
PROG > 5s
1 x PROG > 8s
1 x
Delete actuator /
Deleting one position of the transmitter /
By pressing the programming button on the actuator for
5 seconds, deletion of one transmitter activates. The LED
flashes in an interval of 1s.
Pressing the required button on the transmitter deletes it from
the actuator's memory.
The LED goes out and the actuator returns to operating mode.
Deleting the entire memory /
By pressing the programming button on the actuator for
8 seconds, deletion occurs of the actuator's entire memory. The
LED flashes three times and goes out, then again flashes three
times and goes out.
The actuator goes into the programming mode, the LED flashes
in 0.5s intervals (max. 4 min.).
You can return to the operating mode by pressing the Prog
button for less than 1s.
Attention:
The minimum distance between the controller (system unit) and the actuator must not be less than one
centimeter.
Between the individual commands must be an interval of at least 1s.
Funkgesteuerte Schalteinheit
DE
ELKO
EP
,
s.r
.o.
|
Palackého
493
|
769
01
Holešov
,
V
šetuly
|
Czech
Republic
|
e
-mail:
[email protected]om
|
Support:
+420
778
427
36
6ELKO
EP
Germany
GmbH
|
Minoritenstr
.
7
|
50667
Köln
|
Deutschland
|
E-mail:
[email protected] |
T
el:
+49
(0)
221
222
837
80
www.elkoep.com / www.elkoep.de
230VAC/ 50 -60 Hz120 VAC/ 60Hz12-24VAC/DC 50-60Hz
7 VA / cos φ = 0.1 7 VA / cos φ = 0.1 -
0.7W 0.7 W 0.7W
+10 %; -15 %
2x switching / Schaltkontakt (AgSnO2)
8A/ AC1
2000 VA / AC1
10 A/ < 3 s
250 VAC1
500 mW
1x107
1x105
868 MHz, 915 MHz, 916 MHz
button /Taste PROG (ON/OFF)
up to / bis zu 100 m
-15 ... + 50 °C
any / beliebig
free at lead-in wires / Frei an den Anschlussdrähten
IP30
III.
2
2x 0.75mm2, 2x 2.5 mm2
90 mm
49x 49x 21 mm
46g
EN60669, EN300220, EN301489 R&TTE Directive,Order. No426/2000 Coll.(Directive 1999/EC)/
EN 60669, EN 300220, EN 301489 Richtlinie RTTE, RG Nr.426/2000 Sgl.(Richtlinie 1999/EG)
Technische Parameter
Spannungsversorgung:
Scheinleistung Eingang:
Verlustleistung:
Toleranz der Spannungsversorgung:
Ausgang
Anzahl der Kontakte:
Messstrom:
Schaltleistung:
Spitzenstrom:
Schaltspannung:
Max.DC Schaltleistung:
Mechanische Lebensdauer:
Electrische Lebensdauer (AC1):
Steuerung
RF Signalevon den Sendern:
ManuelleSteuerung:
Reichweite im Freien:
Andere Daten
Arbeitstemperatur:
Arbeitsposition:
Installation:
Schutzklasse:
Überspannungskategorie:
Verschmutzungsgrad:
Anschlüsse (CY Draht, Querschnitt):
Längedes Terminals:
Abmessungen:
Gewicht:
Standards:
Warnung
Die Betriebsanleitung dient der Montage, sowie dem Benutzer des Geräts. Sie ist immer im Lieferumfang enthalten.
Die Montage und der Anschluss darf nur durch eine Person mit einer angemessenen Berufsqualifikation, nach dieser
Bedienungsanleitung und Funktionen des Gerätes und unter Beachtung aller gültigen Vorschriften ausgeführt
werden. Die störungsfreie Funktion des Gerätes hängt auch von Transport, Lagerung und Handhabung ab. Falls Sie
irgendwelche Anzeichen von Beschädigung, Verformung, Fehlfunktionen oder Fehlteilen feststellen, ie das Gerät
nicht und wenden sich an den Verkäufer. Es ist notwendig, dieses Produkt und Teile davon als Elektronikschrott
zu behandeln, nachdem seine Lebensdauer beendet ist. Vor Beginn der Montage ist sicherzustellen, dass alle
Leitungen, miteinander verbundenen Teilen oder Anschlüsse spannungsfrei sind. Während der Montage und
der Wartung sind die Sicherheitsvorschriften, Normen, Richtlinien für die Arbeit mit elektrischen Geräten zu
beachten. Berühren Sie keine Teile des Gerätes, die mit Energie versorgt werden - Lebensgefahr. Aufgrund der
Sendeleistung des RFSignals, beachten Sie den geeigneten Montageort der RF-Komponenten in einem Gebäude,
in dem die Installation stattfindet. RF Control ist nur für die Montage im Innenbereich geeignet. Geräte sind
nicht für die Montage in Außenbereichen und Feuchträumen geeignet. RF Control Komponenten dürfen nicht
in Metallschalttafeln und in Kunststoff - Schalttafeln mit Metalltür installiert werden - Die Durchlässigkeit des
RF-Signals ist dann nicht gegeben. RF Control ist nicht für Aufzüge geeignet - das RF Signal kann gestört und
abgeschirmt werden, die Batterie des Emfängers verliert schnell die Leistung etc. - dieses verhindert die Steuerung
durch eine Steuerungseinheit.
Aktor löschen
Löschen von einer Position des Aktors
Durch Drücken der Programmiertaste auf dem Aktor für
5 Sekunden, wird der Löschmodus aktiviert. Die LED blinkt im
Abstand von 1s.
Drücken Sie die gewünschte Taste des Senders löscht sie aus
dem Speicher des Aktors.
Die LED erlischt, der Aktor ist nun wieder in dem Betriebsmodus.
Den gesamten Speicher löschen
Durch Drücken der Programmiertaste auf dem Aktor für
8 Sekunden, erfolgt die Aktivierung der Löschung des
gesamten Speichers. Die LED blinkt dreimal und erlischt dann
wieder dreimal und erlischt.
Der Aktor geht in den Programmiermodus, und die LED blinkt
in 0.5s Intervallen (max. 4 min.).
Sie können in den Betriebsmodus durch Drücken der Prog-
Taste für weniger als 1s zurückgelangen.
Achtung:
Die Entfernung zwischen Sender und Empfänger sollte nicht weniger als 1 cm betragen.
Zwischen aufeinanderfolgenden Befehlseingaben sollte mindesten 1s Abstand liegen.