EOS ECON I1 User guide

INNOVATIVE SAUNA TECH N O L OGY
IPx4
Made in Germany
ECON I1
Druck Nr. 2934 4778en / 24.18
EN Installation and operating instruction
control unit for infrared warming cabins
Firmware R4.35

2EN
English
Table of contents
General Information...................................................................................................................................4
General safety precautions........................................................................................................................5
Scope of Delivery .........................................................................................................................................7
Technical data.................................................................................................................................................8
Installation of the control unit..................................................................................................................9
Wall installation........................................................................................................................................9
Surface-mounted installation.............................................................................................................9
Recessed installation .......................................................................................................................... 10
Connecting the sensor cables ............................................................................................................... 11
Installation of the main sensor........................................................................................................ 11
Electrical connection ................................................................................................................................ 13
Installation of IR-radiator...................................................................................................................13
Connecting the cabin lamp.............................................................................................................. 13
Installation diagram ............................................................................................................................14
Terminal arrangement on the circuit board............................................................................... 14
Connection diagram for IR-radiators ............................................................................................15
Operation......................................................................................................................................................16
General information............................................................................................................................ 16
The user interface ..........................................................................................................................16
Operating buttons......................................................................................................................... 16
Default display Stand-by.............................................................................................................17
Default display in operation....................................................................................................... 17
Energy-saving display...................................................................................................................17
Symbol description ....................................................................................................................... 18
Operation principle.......................................................................................................................19
Initial commissioning ...................................................................................................................20
Switching the IR-unit on / off..................................................................................................... 21
Temperature query........................................................................................................................ 21
Individual settings ...............................................................................................................................22
Cabin temperature ........................................................................................................................22
Auto-stop / heat-up time limitation........................................................................................23
Cabin lighting.................................................................................................................................. 24
Advanced settings...............................................................................................................................25
Change language...........................................................................................................................25
Change time .................................................................................................................................... 25

3
EN
Activate / deactivate the child lock......................................................................................... 26
Activate / deactivate the Life - Guard .....................................................................................26
Life-Guard .....................................................................................................................................................27
Switching on the IR unit with Life-Guard .......................................................................................... 28
Holiday home - Holiday park mode.....................................................................................................29
Device fuses ................................................................................................................................................. 30
Error messages............................................................................................................................................31
The device„Switch-off“ switch.............................................................................................................. 32
Recycling....................................................................................................................................................... 33
Service address ........................................................................................................................................... 33
General Terms and Conditions of Service.......................................................................................... 34

4EN
Dear customer,
with this IR-control unit, you have received an
advanced electronic device, which was devel-
oped and manufactured to meet to the highest
quality and safety standards.
The following operation instructions describe
how to use the control unit.
Read these instructions carefully and keep it for
future references, in order to quickly and easily
operate your infrared cabin.
General Information
The IR control unit is designed for a power sup-
ply of 230 V 50 Hz and must be separately pro-
tected with 16 A.
According to the valid regulations, the electri-
cal connection of the control unit and the elec-
tric components has to be carried out through
the specialist of an authorized electric shop.
Please check the regulations according VDE
0100 Part 703/2006-2.
To ensure a reliable and trouble-free operation
please read the following installation guide-
lines and manual. Make yourself familiar with
all operation steps.
Make sure to also observe the specications
and instructions of the cabin manufacturer.
Note!
Connecting the mains inputs L1-L3 to only
one phase is not permitted!

5
EN
General safety precautions
• This device can be used by children aged
8 upwards and by persons with physical,
sensory, or mental disabilities, or who
have inadequate experience and knowl-
edge if they are supervised or if they have
received adequate instruction in how to
use the device safely and understand the
associated risks. Children may not play
with this device. Children may not clean
or carry out any user maintenance if un-
supervised.
• Children are to be supervised in order to
make sure that they do not play with this
device.
• !Attention: It is forbidden to install
the control box in a closed switch cabinet
or behind a wooden panelling!
• The electrical installation may be done
only by a qualied electrical technician.
• You must comply with the regulations of
your power supply company and the ap-
plicable local legal regulations, such as
e.g.VDE regulations (DINVDE 0100).
• !WARNING: Never attempt repairs or
installations by yourselves, as this could
result in serious injury or death. Only a
qualied technician is allowed remove
the housing cover.
• Please note the dimensions in the assem-
bly instructions, especially when installing
the temperature sensor. The temperature
above the oven is critical for the temper-
ature setting. The temperature can be
held within operating parameters and a
minimal temperature gradient inside the
the cabin can be achieved only if unit is
installed correctly.
• The device may only be used as intended
as a control unit for IR radiators or IR heat-
ing foils.
• !Only the IR radiators or heating foils
with the integrated overheating protec-
tion 140°C compliant with the EN 60335
norm are permitted to be used.
• Completely disconnect the control unit
from the electrical circuit, i.e. ip all circuit
breakers or the main circuit breaker during
each installation or repair.
• Please observe the safety and installation
information of the manufacturer of the IR
heating equipment.
• Make sure to also observe the specica-
tions and instructions of the cabin manu-
facturer.

6EN
!
Attention!
Dear customer,
according to current legal regulations, the
electrical connection of the IR radiator
and the control unit has to be carried out
through the specialist of an authorized
electric shop.
We would like to draw your attention that
in case of a warranty claim, you are kindly
requested to present a copy of the invoice
of the executive electric shop.
!
Attention!
Only the original spare parts may be used.
Any modication of the cables included in
the delivery can lead to malfunctions and
is not permitted.
Any unauthorized technical alteration
makes the product warranty void.

7
EN
Scope of delivery
(changes without prior notice reserved)
The package contents includes:
1. Control unit
2. Temperature sensor, consisiting of: sensor circuit board with overheating protection fuse, KTY-
sensor, sensor housing, two 3x25 mm fastening screws and 2,0 m sensor cable.
3. Plastic bag with three 4x25 mm fastening screws.
4. 5 rubber cable glands
5. 1 replacement overheating protection fuse
6. Installation and operating manual
4
5
1
2
3
6
a
b
c
d

8EN
Technical data
Voltage (power supply) 400 V 3 N 50 Hz AC
Switch output max. 9 kW resistive load (AC1 mode).
Heating time limit: 12 h
Display LCD display 40 x 22 mm, graphic
Dimensions (HxWxD) 220 x 250 x 67 mm
Protection type IPx4 acc. to EN 60529 splashwater protection
Temperature control range 30 to 70 °C
Sensor system (temperature) KTY-sensor with safety temperature limiter 139 °C
Control characteristic Two-point control with xed hysteresis of 3K. For control via
the stove sensor oset of 7K to compensate the higher tem-
peratures directly below the cabin ceiling
Light max. 100 W
Ambient temperatures -10 °C to +40 °C
Storage temperature -20 °C to +70 °C
T
emperature display
temperature
sensor
Current value on the sensor minus 7K to compensate the
higher temperatures directly below the cabin ceiling

Installation of the control unit
Wall installation
The control unit may only be mounted outside
the IR-cabin. It is advisable to select the out-
side wall of the cabin to which the IR-radiator
is xed from the inside as mounting position.
If ductwork is already provided for electrical in-
stallations then the position of the control unit
is predetermined by that. Please follow the in-
structions for installation:
Fig. 1
1. The 3 mm diameter boreholes for the sup-
plied wood screws 4 x 20 mm are drilled ac-
cording to the dimensions shown in Fig. 2 +
3.
2. Insert one of the wood screws into the top
center hole. The control unit is hooked onto
this screw. Therefore, leave the screw out by
approx. 3 mm (Fig. 3.1).
3. Hook the control unit onto the 3 mm pro-
truding screw in the upper mounting hole.
Insert the supplied rubber grommets into
the openings at the rear wall of the hous-
ing and insert the connecting cable through
these openings.
Fasten the housing bottom at the two bot-
tom openings (Fig. 4) rmly to the cabin wall.
Eye level
Upper mounting hole
Remove the control device cover. In order to do
this loosen the screw at the top of the housing
and pull the housing top upward while swivel-
ling (Fig. 1).
Surface-mounted installation
Fig. 4
ca. 35 cm
Fig. 2
Fig. 3.1
3 mm
Fig. 3
17 cm
17,7 cm
Augenhöhe
Feed-through for:
Mains cable
IR cable
Lamp
Feed-through for:
through for
sensor lines
ca. 35 cm
Mounting holes
9
EN

Recessed installation
1. Cut out a wall section that is at least 3.5 cm
deep according to the dimension in Fig. 5.
Insert the supplied rubber grommets into the
openings at the rear wall of the housing and
insert the connecting cables through these
openings.
Place the control unit into the wall opening and
fasten it with 4 wood screws.
Eye level
Fig. 5
Fig. 6
Feed-through for:
Mains cable
IR cable
Lamp
Feed-through for:
sensor lines
21 cm
20 cm
Holes to fasten the control
unit inside the wall opening.
10 EN

11
EN
Connecting the sensor cables
You should not install sensor and power supply
lines together, or lead them through the same
feedthrough. This can lead to interferences in
the electronics, such as "uttering" in the re-
lays. If it is necessary to lay the cables down
together, or if the line is longer than 3 m, use a
shielded sensor cable (4 x 0.5 mm²).
Connect the shielding to ground in the control
unit.
Please observe that the following dimensions
relate to the values stipulated during the unit
inspection acc. EN 60335-2-53. The heater sen-
sor must always be installed at the point where
the highest temperatures are to be expected.
Illust. 7-9 give you an overview of the mounting
point of the sensor.
Fig. 7
Housing
Red
Red
Sensor circuit board
Sensor
white (Limiter)
white (Limiter)
Fig. 8
Fig. 9
2. Drill a hole to lead the cable through, prefer-
ably through the middle of one of the wood-
en boards.
3. Lead the sensor cable through the drilled
hole and attach it to the sensor line accord-
ing to g. 8.
4. The cables for the temperature sensor (red)
are connected to the sensor circuit board ac-
cording to Fig. 9. Engage the sensor board
into the casing.
5. Lead the sensor cables through the right
cable intake into the control unit. Install
the sensor cables inside the control unit as
shown in Fig. 10. Connect the sensor cables
as shown in Fig. 11. In order to do this, pull
the plug X2 from the circuit board and plug
it back in after the connection.
Installation of the tempera-
ture sensor
1. The temperature sensor should be mounted
on the ceiling in the middle of the cabin. See
g. 7 for details.

12 EN
X2
N L
F2
Hole in the ceiling panel
cabin ceiling
Centre sensor housing
on middle section
Sensor cables
Sensor
Fig. 10
142°C
KTY 10/5
Sensor
Limiter
X2
weiß / white
rot / red
Fig. 11
6. After completed installation and correct
commissioning of the control unit, the line
for overtemperature protection must be
checked for short-circuits. In order to do this,
disconnect one of the wires of the white ca-
ble in the sensor casing. The respective error
message appears in the display. Reconnect
the wire to make the message disappear.
Attention! Incorrect connection at the con-
nector X2 will cause the fuse F2 to blow (see
chapter„Errors“ for replacement advice).
by use of screen-protected sensor
cables connect ground
12 : 00
Thermo -
fuse

13
EN
Electrical connection
The electrical connection may only be done
by a certied electrician in compliance with
the guidelines of the local utility company
and the VDE.
In general, there should be only one perma-
nent connection to the mains. Furthermore,
equipment should be provided that makes it
possible to disconnect the system on all phases
from the mains with a contact opening width
of minimum 3 mm.
All electrical installations and all connection
lines that are installed inside the cabin must be
suitable for an ambient temperature of at least
170 °C.
The power supply line is run to the control unit
and connected to the power input terminals.
• The cabin lamp must be suitable for the
temperatures expected in the infrared
cabin.
• Lay the connection cable from the control
unit to the lamp through the pre-drilled
hole in the cabin wall, so that the cable
is not visible inside cabin. Make the con-
nections as per connection diagram and
installation guide for the lamp.
• The lamp should be installed as far as pos-
sible from the IR-radiators and may not be
installed within the direct heat radiation
range.
• Make sure to observe the maximum
power load of the light output.
Connecting the cabin lamp
Installation of IR-radiator
• Install the IR-radiator in the cabin as per the
appropriate installation manual.
• Please note that the maximal power of con-
nected IR-radiators per phase may not ex-
ceed 3500 W.
ATTENTION!
Swapping the phase line and neutral line
will damage the control unit and can make
the safety-relevant components fail.
Danger to life!

14 EN
Installation diagram
35
4
5
400 V 3 N AC 50 Hz
ECON
Terminal arrangement on the circuit board
X2
F2
F1
L1 L2 L3 N W V U N
N L
Plug for sensor connection
N terminal only for light output!

15
EN
Connection diagram for IR-radiators
X1
UVWNL1 L2 L3 N
N L
ECON
400 V 3 N AC 50 Hz
max. 100 W
139°C
KTY 10/5
Sensor
Limiter
weiß / white
rot / red
X2
If you use this device with single phase with max. 3kW, the power
supply must be connected to terminal L1 and the load to output U.

16 EN
Operation
General information
Once the system has been installed with all components and the front cover has been xed, you
can put the control unit into operation.
Over the following pages we will show you the options provided to you with the control.
The user interface
Operating buttons
= Cabin lighting on / o
= Heating on / o (stand-by mode)
= Programming mode
= Increase the value / next function
= Decrease the value / next function
MODE
LCD-Display
operation buttons
MODE

17
EN
Default display Stand-by
Default display in operation
is shown if the system is in Stand-by mode.
The system also returns to this screen from
other menu items, if there is no activity for >15
seconds.
is displayed when the system is operational.
The display changes between the set tempera-
ture and the remaining heating time (Auto-
Stop). The system also returns to this screen
from other menu items, if there is no activity for
>15 seconds.
Illustration of the heating performance:
During the heating phase, the thermometer
lls in the right part of the display.
Once the target temperature has been reached,
the thermometer is displayed as lled.
Energy-saving display
If the unit is not used, it will switch into energy-
saving mode.
A moving time is shown after 5 minutes, simi-
lar to a PC screensaver. The back light for the
display is switched o after an additional 15
minutes.
You can return to the basic standby screen by
pressing any button.
To start heating press the On/O button for >3
seconds.
12:34
Temperature
50°C
12:00
Temperature
50°C
12:00
Auto-Stop
5:59

18 EN
Symbol description
The following is shown in the top area of the display:
12:00
P1
R
Light symbol • Light switches on automatically when heating is switched on
• Light stays on 30 min. after the heating stops
• Manual light switching is possible at any time
Clock symbol • Time indication
12 : 00
Clock • Displays the time of day
Keypad lock • Locks all buttons but still allows to switch o heating if the system
is currently running.
• Light can be still switched on and o
Holiday home mode
Holiday park mode
• Holiday home = symbol static, resticted access mode
• Holidays park = symbol ashing, restricted access, only on/o
• possible

19
EN
12:00
Temperature
50°C
50° C
Temperature
12:00
Temperature
50°C
12:00
Temperature
50°C
Modiable parameter
Modiable value
For settings press shortly the MODE -button.
Use the or - buttons to navigate to the
required parameter which you would like to
adjust.
Press the MODE button again shortly to start
the adjustment for the selected parameter.
The background of the value of the selected
parameter will be ashing.
Now you can adjust this value using the or
buttons.
All settings made in the standby mode should
be conrmed by pressing MODE for >3 secs and
are then saved in the current prole.
The parameter stops ashing and the new va-
lue becomes valid until it is changed again.
If no button is pressed for >15 secs, the device
returns to the standard screen. Any changes
made will not be saved.
Parameter values that ash on the display can
be changed and are shown in this manual as
displayed.
Operation principle

20 EN
12:00
Life - Guard
12:00
Life - Guard
12:00
DE
GB
NL
PL
IT
RU
DE
GB
NL
PL
IT
RU
12:00
> 3 Sec
MODE
Set language (DE, GB, IT, NL, PL, RU, FR, SE, ES, CZ, FI, SLO)
Set time of day (0:00 bis 23:59)
Set Life-Guard function
00:00
0: 00
Time of day
00:00
12 : 00
Time of day
00:00
12 : 00
Time of day
00:00
12 : 15
Time of day
MODE
> 3 Sec
MODE
Enable of disable Life-Guard
Select and conrm one of the following:
- disable, or - enable.
> 3 Sec
MODE
Initial commissioning
Table of contents
Other EOS Control Unit manuals

EOS
EOS ECON F1 User manual

EOS
EOS EmoTouch II + Owner's manual

EOS
EOS 94 00 Series User manual

EOS
EOS ECON H4 User guide

EOS
EOS EmoTouch II + User manual

EOS
EOS InfraTec Premium User guide

EOS
EOS EMOTEC DC 9000 User manual

EOS
EOS InfraStyle User manual

EOS
EOS SBM App Module Manual instruction

EOS
EOS ECON 45A2 Planning guide
Popular Control Unit manuals by other brands

Trinamic
Trinamic PD-1160 Getting started

Dyna-Flo
Dyna-Flo 570 Operation, Parts, and Instruction Manual

GEM
GEM 613 Installation, operating and maintenance instructions

Elektrogas
Elektrogas VML Series Technical manual

Leadshine
Leadshine 2CS3E Series user manual

Hacker
Hacker UAV Control Opto Pro Series manual