EmoStyle Di
EmoStyle Hi
sauna control unit

2EN
English
Contents
Preface and general information about sauna bathing............................................................................ 4
General safety precautions.............................................................................................................................. 5-6
Scope of delivery .................................................................................................................................................... 7
Accessories ................................................................................................................................................................ 7
Technical data....................................................................................................................................................... 8-9
Intended use............................................................................................................................................................. 9
Installation ........................................................................................................................................................ 10-17
Main electronic unit............................................................................................................................... 10-11
Control panel - location and cable connection ..................................................................................12
Control panel - voltage regulator ............................................................................................................13
Control panel - ush-mounted installation................................................................................... 14-15
Installation of the temperatur sensor.............................................................................................. 16-17
Electrical connection..................................................................................................................................... 18-22
Sauna heater connection............................................................................................................................18
Sauna lamp connection ..............................................................................................................................19
Connection of the power extension unit..............................................................................................19
Installation diagram and terminal layout ...................................................................................... 20-21
Temperature sensor......................................................................................................................................22
Humidity sensor.............................................................................................................................................22
2nd temperature sensor (bench sensor)...............................................................................................22
Overview - connection scheme (Emotec D/H, EmoStyle D/Di and H/Hi).........................................23
Humidity sensor installation .............................................................................................................................24
Vaporizer connection...........................................................................................................................................25
Installation of the optional bench sensor.....................................................................................................26
Setup (commissioning / rst switching) ................................................................................................ 27-28
Operation.......................................................................................................................................................... 29-40
Overview...........................................................................................................................................................29
Symbol description (main navigation menu)......................................................................................30
Graphic user interface .................................................................................................................................31
Operation and program settings ...................................................................................................... 32-36
Symbol description (extended settings)...............................................................................................37
Extended settings................................................................................................................................... 38-40

3
EN
Manual setting of the lamp ...............................................................................................................................41
Service................................................................................................................................................................ 42-46
Service- and Setup ........................................................................................................................................42
Symbol description.......................................................................................................................................43
Settings ...................................................................................................................................................... 44-46
Troubleshooting (error messages)..................................................................................................................47
The ”switch-o“ rocker switch..........................................................................................................................48
Recycling ..................................................................................................................................................................49
Service Address......................................................................................................................................................49
General Terms and Conditions of Service.....................................................................................................50

Please note that an optimal interaction bet-
ween sauna cabin, sauna heater and sauna
control unit is mandatory for a pleasant sauna
climate in your cabin. With this high-quality
sauna control unit you can “operate“ your sau-
na system, and thanks to the many individual
programming options, surely you will quickly
nd the setting which suits you best.
Perception in the sauna is very subjective, the-
refore, it really requires your own perception
or that of your family to nd the most suitable
settings.
The control units are supplied with the preset
typical climate values for a classic Finnish sauna
or for models with humidity control, as well as
for a sauna with humidity operation.
The following operating instructions describe
how to pre-select “your“ climate in the cabin.
Read these instructions carefully, so that you
General information about
sauna bathing
Preface
quickly and easily nd your way though the
programming process. Please note the varia-
tion in temperatures in the cabin while sauna
bathing. The hottest area is directly below the
cabin ceiling, whereas there is a steady tempe-
rature gradient towards the oor of the cabin.
Inversely, the relative humidity is lowest direct-
ly below the cabin ceiling and the highest by
the cabin oor.
For safety reasons the temperature sensor with
the overheat safety shutdown is located on the
cabin ceiling above the heater, as this is usually
the hottest area in the cabin.
Thus, there will always be temperature varia-
tions between the temperature sensor of the
control unit and the thermometer in the cabin.
For example, when pre-setting the cabin tem-
perature to 100 °C, the thermometer inside the
cabin may show 85 °C - 90 °C. This is in accor-
dance with the typical climate inside the cabin.
Only use sauna-suitable (up to 140 °C tempera-
ture-resistant) cabin lights. Always pay attenti-
on to hygiene. Always use hand- or bathing to-
wels to avoid getting perspiration on the wood.
For control units with vaporizer connection
(optional), we recommend to reheat or dry the
cabin after each humid operation, in order to
protect your cabin from possible damage due
to the humidity mode. In addition, in poorly
ventilated rooms, a ventilation fan can be used
to remove the used moist air.
To avoid drafts, you should avoid using any
ventilation system while sauna bathing. It
should only be used if recommended by the
cabin manufacturer.
Dear customer,
you have purchased a high-quality electronic
device with which you will enjoy your sauna for
many years to come.This sauna control unit was
designed and inspected according to the current
European safety standards and manufactured
at the factory in accordance with the quality
management standard DIN EN ISO 9001:2015.
This detailed installation and operation manual
has been prepared for your information. Pay
particular attention to the important notes and
the information on electrical connection.
We wish you a restorative and eventful sauna
bathing experience.
4EN

General safety precautions
• This device may be used by children (age
8 and above) and by persons with reduced
physical, sensory, or mental disabilities, or
inadequate experience and knowledge,
if they are supervised or if they have re-
ceived adequate instructions in how to
use the device safely and understand the
associated risks. Children may not play
with this device. Children may not clean
or carry out any user maintenance if un-
supervised.
• Children are to be supervised, in order to
make sure that they do not play with this
device.
•
!
ATTENTION: It is forbidden to install
the control box in a closed switch cabinet
or behind a wooden panelling!
• The electrical installation may only be
done by a qualied electrical technician.
• You must comply with the regulations of
your power supply company and applica-
bleVDE regulations (DINVDE 0100).
•
!
WARNING: Never attempt repairs or
installations yourself, as this could result
in serious injury or death. Only a qualied
technician may remove the housing cover.
• Please note the dimensions in the instal-
lation instructions, especially when in-
stalling the temperature sensor. The tem-
perature above the heater is critical for the
temperature setting. The temperature can
be held within operating parameters and
a minimal deviation at the bench level of
the sauna cabin can be achieved only if the
device is installed correctly.
• The device may only be used as intended
as a control unit for sauna heaters up to 9
kW (up to 36 kW when combined with a
power extension unit).
• Completely disconnect the control unit
from the electrical circuit, i.e. ip all circuit
breakers or the main circuit breaker during
each installation or repair.
• Please note the safety and installation
information from the sauna heater man-
ufacturer.
• Make sure to observe the specications
and instructions of the sauna cabin man-
ufacturer.
!
ATTENTION: For control units with
remote control functions*, a protection
against switching on if the heater is covered
is required. (e.g. cover protection rail type
1-5).
*Remote control = setting up, controlling or adjust-
ing a unit by a command that can be given out of
view of the unit by means of transfer media such
as telecommunication, audio technology or bus
systems, this also includes weekly timers. (from EN
60335-1)
5
EN

!
Attention!
Dear customer,
according to the valid regulations, the
electrical connection of the sauna heater
and the control box has to be carried out
through the specialist of an authorized
electric shop
We would like to draw your attention that
in case of a warranty claim, you are kindly
requested to present a copy of the invoice
of the executive electric shop.
!
When designing the sauna cabin, en-
sure that the external exposed glass surfaces
may only reach a maximum temperature of
76 °C. If necessary, protective features need
to be tted.
Inspect the sauna cabin before each
use! In particular, ensure that no objects
have been stored on the sauna heater or the
IR-radiator, if applicable.
Risk of re!
!
Attention!
Onlytheoriginalspareparts maybeused.
Anymodicationofthecables includedin
the delivery can lead to malfunctions and
is not permitted.
Any unauthorized technical alteration
makes the product warranty void.
6EN

7
EN
Scope of delivery
Check the device for completeness upon receipt. The delivery includes:
1. Main electronic unit (with two-part front cover)
2. Control panel with colour display
3. Voltage regulator
4. Housing base for ush-mounted installation of the control panel
5. De-installation tool (for control panel)
6. Temperature sensor: a) housing, b) sensor board, c) overheat protection fuse, d) 2 mounting
screws 4 x 40 mm, e) connection cable 5 m with RJ10 plug, f) 2-core white cable for overhea-
ting protection fuse 5 m
7. Connection cable (control panel - main block) with RJ14 / RJ10 plugs
8. 1 spare overheating protection fuse
9. Plastic bag with 3 mounting screws 4 x 25 mm (for main electronic unit)
10. 8 rubber cable glands
11. 1 installation and operation manual, 1 operation manual (for end users)
2
3
2nd sensor ..................................Item no. 94.5725
Humidity sensor........................Item no. 94.5726 (only H-model)
Coloured light control module...Item no. 94.5996, 94.6007
Sound module...........................Item no. 94.5920, 94.5921
Remote start modul..................Item no. 94.5782
SBM-WCI-01 web app module..Item no. 94.5987
KNX-/Modbus-module..............Item no. 94.7078 / 94.7077
SBM-HOT...................................Item no. 94.6800
SBM-ECO...................................Item no. 94.6980
Accessories (optionally available):
5
11
910
6
f
e
a
b
c
1
7
d
8
4

8EN
Technical data
Voltage (power supply): 400 V 3 N AC 50 Hz
Switching capacity: max. 9 kW resistive load, may be extended with a power
extension unit (LSG)
Fuse 3 x 16 A
Heating time limit: 6 h / 12 h / unlimited
Housing: plastic, shatter-resistant
Display: TTFT colour display 55 x 74 mm (3,5“ size)
Operation: 5 capacitive buttons on the control panel
Protection type: IPx4 in accordance with EN 60529, splashproof
Temperature control range: 30° - 115°C (dry sauna mode)
30° - 70°C (humid sauna mode - only H series models)
Humidity control: proportional to time or optionally as per rel. air humidity
(%) with
an optional humidity sensor.
Sensor system: Digital sensor with oveheating protection fuse (STB) 139°C
Control characteristic: Digital two-point control
Connection for fan: min. 5 W, max.150 W (only fans without starting capacitor)
Only use fans suitable for phase control!
Connection for light: • min. 5 W (20 mA)
• resistive loads - max. 100 W,
• dimmable energy saving lamps - max. 35 W
• Lamps at conventional transformers - max. 60 VA.
Attention: only dimmable lamps may be used!
!Fan and light output share a common 2AF fuse.
Volt-free output: contact’s resistive load carrying capacity:
maximum current: 16 A
maximum voltage: 30 V DC / 250VAC
Start time pre-selection: up to 24 h in advance
Switching automation: Week timer with 4 switching programs per day
Error display: Clear text error indication on the display
Outputs: 3 x RJ10 jacks for sensor connections
2 x RJ14 jacks for control panel and extension modules
1 x potential free contact (2 terminals)
Output S1: maximal load 50 W / 50 VA, no capacitive loads allowed.
Terminal block area for power
supply and heater connection:
0.5 – 2.5 mm² rigid or exible crimped wire, two cores with
the same cross section per terminal may be connected
Terminal block area WM, 3, 4,
light, fan:
0.34 – 2.5 mm² rigid or exible crimped wire. Please observe
the minimal cross section as per fuse protection of the line!

9
EN
Important note!
The control unit is not suitable for outdoor use!
It may only be used inside buildings and may not be exposed to environmental conditions
such as extreme humidity or moisture with possible condensate formation or corrosive
substances in the ambient air and other weathering. Excessive exposure to cold and in-
tense solar radiation should be avoided as well. If there is an increased risk of mechanical
damage, the control unit must be protected accordingly.
Card reader: Micro-SD card reader in control panel
Ambient temperatures: -10°C bis +35°C
Storage temperatures: -20°C bis +60°C
Place of installation requirement: Intended for indoor installation only.
Sensors - may not be installed in corrosive or highly salty
environment.
Device - may not be installed in corrosive environment or in
an environment which may cause water condensation.
Dimensions main block: H 270 x W 300 x D 100 mm
Dimensions control panel: H 202 x W 142 x D 42 mm (ush-mounting)
recessed part 37 mm deep
Intended use
This sauna control unit is exclusively intended
for the control of the sauna heater in a sauna
cabin. Any other use over and above the inten-
ded purpose is not considered as appropriate
use! Compliance of the standard operation,
maintenance and repair conditions is also an
element of appropriate use.
The manufacturer cannot be held liable for
deviating, unauthorized alterations and any re-
sulting damages: the initiator of these changes
bears the full risk.

10 EN
Installation of the main electronic unit
1. Remove the lower cover from the relay box. Unscrew the 3 xation screws, then slightly pull
the lower housing cover down and take it o. See g. 1 for details.
The main electronic unit (relay box) may be installed only outside the sauna cabin. The recom-
mended places of installation are the outer sauna wall or the engineering room (plant room). If
empty ducts for connection cables are already available, then they usually predetermine the in-
stallation position. The installation shall be carried out as follows:
1.
2.
210
180
3
!
Attention: The relay box may not
be installed in a closed switch cabinet
or behind a wooden panelling!
Risk of overheating! Fire hazard!
Fig. 1
Fig. 2
The holes for the provided 4 x 25 mm screws are to be installed according to the dimensions
shown in Fig. 2.
2. Use the upper central screw to hang the relay box. Make sure that this screw stands out ap-
prox. 3 mm (detail in Fig. 2).

11
EN
180 mm
210 mm
Lower mounting holes
Fig. 3
3. Hang the housing on the upper central screw in the upper central mounting hole.
Insert the supplied rubber cable glands into the openings of the bottom of the housing (from
below or from behind, as desired) and then guide the connection cables through these open-
ings.
Screw the lower part of the housing rmly to the cabin wall in the two lower mounting holes
(Fig. 3).
Fig. 4
Knock-out openinigs for connection cables
for heater, vaporizer, fan, lamp.
Knock-out openings
for sensor cables
upper central mounting hole

12 EN
189 mm
128 mm
max.
1500 mm
Lay the connection cable from the relay box to
the control panel.
The connection cable may be laid only be-
tween the outer sauna wall and insulation layer
to prevent overheating (g. 6).
The insulation should ensure that the temper-
ature at the outer sauna wall may not exceed
65 °C.
Make sure that the cable with the smaller plug
(RJ10) is routed to the control panel.
Fig. 5
Control panel
Location
The control panel may be mounted inside the
sauna cabin on the sauna wall. If ductwork is al-
ready provided for electrical installations then
the position of the control panel is predeter-
mined by that.
The control panel is designed for ush-mount-
ed installation into the sauna wall. The installa-
tion shall be carried out as follows.
First of all determine the location.
Make an installation cut-out in the wall with the
size 189 mm height x 128 mm depth (g. 5).
Use the supplied 5 m connection cable with
RJ10 plug (control panel side) and RJ14 plug
(relay box side).
If necessary, this connection line may be ex-
tended to approx. 100 m length. The extension
should occur on the relay box side. For this pur-
pose, a coupling (RJ14 / RJ14) and an extension
cable with RJ14 connector are required (availa-
ble from specialist dealers).
!
Important notice:
Maximum cable length between control
panel and main unit is 100 m.
Cable connection
Outer sauna
wall
Connect-
ion cable
Inner sauna
wall
Fig. 6
Inner-
control panel
Voltage regulator
Insulation
Installation
on wooden
planks
Connect-
ion cable

13
EN
1,5 m
0,7 m
Notes on mounting the control panel in sauna cabins
Can be used in sauna cabins in areas up to 110 °C (area 2).
Never directly above or in the surrounding area of the sauna heater (area 1),
or in the direct radiation range of short-wave infrared radiators.
.
ATTENTION!
When installing the control panel, ensure the tightness in the inside of the cabin. Excessively high temperatu-
res inside the control panel can lead to errors with the electronic components.
Area 1
Area 2
Area 3
The voltage regulator may be placed e.g. on
the sauna roof. Guide the connection cable of
the voltage regulator to the control panel and
insert the plug into the corresponding small
socket on the circuit board before inserting the
control panel into the lower part (see g. 7).
The voltage regulator must not be exposed to
elevated temperatures. Therefore, the installa-
tion in the sauna wall is not permitted. The vol-
tage regulator may be placed e.g. on the sauna
roof.
The control panel is equipped with an external
voltage regulator. This component is located
in a small separate metal housing and is con-
nected to the control panel by cable.
Fig. 7
Connect voltage
regulator here
Control panel interior
Voltage regulator
Voltage regulator

14 EN
alle Maße in mm
Änderungen vorbehalten
142
202
3
189
128
37
37
4x
4x
4x
4x
4x
Minimum wall depth:
37 mm
First install the housing base (see g. 8).
1. Loosen 4 screws on the fastening brackets
2. Pull the connection cable and the voltage regulator cable through the cable duct in the hou-
sing base.
3. Insert the housing base into the wall opening.
4. Adjust the brackets by moving them on the fastening brackets of the housing part to the de-
signated wall panelling thickness.
5. Clamp the brackets (by tightening the screw clockwise)
Wall aperture:
Hight: 189 mm
Width: 128 mm
Depth: min. 37 mm
Installation of the housing base
Flush-mounted installation (wall-mounting)
Fig. 8
Cable duct position
Fig. 9
Notice:
Please pay attention to the
correct orientation of the
bottom housing. The con-
nection cable duct must be
at the bottom side (see g.
8).
= Dimensions must be strictly adhered to

15
EN
How to remove the display panel
In order to remove the display panel, use the included removal tool or a
similar suitable tool like a at headed screwdriver.
Insert the two tools into the grooves on the side edge of the control pan-
el (between control panel and wall housing) and lever the control panel
from the wall surface, then pull it out of the wall housing. Make sure that
the connection cable can also be removed from the wall housing.
Remove the connection cable from the RJ-plug on the control panel. For
this purpose, carefully press on the small securing tab of the plug and pull it out of the connector.
Important note:
For the removal, use the tools exclusively for the provided grooves in the control panel.
Under no circumstances may the tools be used elsewhere!This can damage the glass of the
control panel. In this case, the warranty is void!
ca. 3 m
ca. 3 m
Bauteil
Fig. 10
Installation of the housing upper part (control panel with display)
Place the control panel directly in front of the housing base and pay attention to the correct orien-
tation. Plug in the connection cable with the RJ10 plug to the control panel. Now press the control
panel carefully into the housing base until the fastening tabs lock securely. Make sure the control
panel sits reliably in the base part.
Notice: When you lay the connection cable do not pull it too tight, allow some extra length around
the base, so that later you can easily take the control panel out of the base while still having it
connected.
Fig. 11
use tool
here
The voltage regula-
tor must be mounted
within a radius of ap-
prox. 3 m (cable length)
away from the control
panel.
Voltage regulator

16 EN
20 cm
19 cm
< 2 x 2 m
35 cm
> 2 x 2 m
Connection of sensor cables
Do not lay sensor and power supply lines together, or lead them through the same duct. This can
lead to interferences in the electronics, such as“uttering” in the relays. Connect the cable shield-
ing (if present) to ground in the control unit.
Please observe that the following dimensions relate to the values stipulated during the unit in-
spection acc. EN 60335-2-53. The heater sensor must always be installed at the point where the
highest temperatures are to be expected. Fig. 12-14 provide you an overview of the mounting
point of the sensor.
1. Mount the heater sensor in cabins up to 2 x 2 m according to g. 13, in larger cabins according
to g. 14.
2. Drill a hole to lead the cable through, preferably through the middle of one of the wooden
planks.
Fig. 12
Fig. 13 Fig. 14
Installation of the temperature sensor
Make sure that there is no deviating mounting position of the sensor, specic to
the sauna heater (check the installation guide of the sauna heater).
sensor line
heater heater
sensor line
Sauna control
unit. Display
panel design
may vary.
Sauna control
unit. Display
panel design
may vary.

17
EN
Drilled hole in the ceiling
Sauna ceiling
Sensor, mounted in
the middle of a plank
Sensor cables
Sensor connector
RJ10 in relay box
Connector for the overheating pro-
tection fuse line STB (white cable)
Fig. 15
Fig. 16
3. Lead the sensor cable (red) and the limiter cable (white) through the drilled hole and connect
both cables to the main relay box.
4. Connect the sensor cable to the sensor board according to g.15. Make sure the connections
are correct. Connect the limiter cable (2-core white cable) to the limiter board (STB).
5. Mount the sensor to the ceiling plank using two supplied screws and attach the housing
cover.
6. After completed installation and correct commissioning of the control unit, the sensor line for
overheating protection must be tested for proper functioning. Disconnect one of the wires
of the white cable at the STB board in the sensor housing - the respective error message shall
appear on the display. Re-connect the wire to make the error message disappear.
Temperature sensor - connections:
Temperature sensor -
installation overview:
connection pins on the sensor board Attention:
Please pay attention that during the in-
stallation of cable lines for sensors and the
display panel, it is not permitted to pull the
cable by the modular plug. If you draw the
cable through the ducts, it must not be at-
tached to the plug, but to the cable only!
Pulling the cable by the plug may damage
it and cause loose contacts resulting in mal-
function of the control unit. In such case the
warranty will be void and the cable should
be replaced.
Make sure to observe the correct wire con-
necton order on the temperature sensor
board as shown on g. 15.
Temperature sensor
board
white
green
brown
Overheating protec-
tion board (STB)
white

18 EN
Install the sauna heater and the vaporizer in
front of the air intake according to the manu-
facturer’s installation instructions.
Draw the silicone cable through the ductwork
to the relay box and connect it to the appropri-
ate terminals as directed in the wiring diagram.
Make sure to observe the wiring diagrams on
pages 18 - 19 with the corresponding terminal
connection scheme.
Notice:In case there is no ductwork available
drill a hole next to the air intake opening and
run the heater line through this hole to the
outside and to the appropriate terminals in the
control unit. The silicone line must be covered
to protect it from outside inuences. There-
fore, use a suitable cable-duct or a PVC-pipe
through which you can run the line up to the
power unit.
Special advice for connection of
Bi-O sauna heaters to control unit
models H/Hi.
Sauna heater connection
!
Attention!
When the vaporizer is connected, the
output“U”is switched from the heater to
the terminal“Wb”to the vaporizer.
The sauna heater will then operate with
2/3 of the total power (if no LSG 18 H or LSG
36 H is used).
Electrical connection
The electrical connections may only be car-
ried out by a certied electrician in compli-
ance with the guidelines of the local power
supply company and applicable legal regu-
lations (e.g. VDE norms for Germany).
In general, there may be only one permanent
connection line to the network. Furthermore,
equipment should be provided that makes it
possible to disconnect the system on all phases
from the power supply with a contact gap of
minimum 3 mm.
All electrical installations and all connection
lines that are installed inside the sauna cabin
must be suitable for an ambient temperature
of at least 170 °C.
The power supply line shall be laid to the con-
trol unit and connected to the power input ter-
minals.
The power supply cable shall be laid to the
main relay box and connected to the power
input terminal as per connection diagram (see
wiring diagrams, page 18-19).
Relay box, lower front cover opened
Fig. 17

19
EN
LSG
Sauna lamp connection
Connection of the power
extension unit
The switching capacity may be extended with
an external power extension unit (LSG), in or-
der to connect and operate the sauna heaters
above 9 kW power.
For connection details please refer to the instal-
lation and operation manual for the respective
LSG model.
!The sauna lamp must have the protection
class of at least IPx4 and should be resistant to
the ambient sauna temperatures. The sauna
lamp may be installed at any location but never
close to the rising hot air of the heater.
Only dimmable lamps may be used.The control
unit will detect strongly inductive loads and
will adjust the phase edge control accordingly.
Make sure to observe the specications of the
light output of the control unit for each light
type.
!Notice: for connection of not dimma-
ble lamps there is a risk of damaging either
the illuminant or the control unit. No war-
ranty claims may be accepted in this case.
Only use fans whose speed can be controlled
via phase control. The fan must have the
splashwater protection class (IPx4) and must
be resistant to the ambient temperature. The
fan can be mounted anywhere, however never
close to the rising ow of hot air from the stove
and must be positioned as far away as possible
from the IR spot (it may not be in the light path
of the spot).
Fan
Heating time limitation
The maximal heating time may be limited with
the jumper #5 on the main board of the relay
box. The limitation may be set to 6 hours, 12
hours or to unlimited.
If the control unit has been set to private use,
then the heating time will be automatically lim-
ited to 6 hours.
The jumper setting will override the software
settings.
The terminals “3“ and “4“ on the main board of
the relay box are the terminals of the normal-
ly open (NO) contact of a relay. Both terminals
have no further connection and are therefore
potential-free (voltage free). You can inte-
grate this NO contact into any circuit, in order
to switch an external power load or to relay a
switching signal.The max. load on the potential
free contact, depending on whether AC or DC
shall be switched, is given in the specications
on the page 5.
!
Attention! If you use the terminals L1,
L2 or L3 to power the circuit connected to
the potential free contact, then the connec-
tion line should not be overloaded. If neces-
sary, the load (consumer) connected to the
potential free contact should be additionally
protected and provided with a separate po-
wer supply.
Potential-free contact
Jumper 5
6 h
12 h
24/7
Jumper settings

20 EN
}
}
STB
}
I
II
fan light
FL FN LL LN
L1 L2 L3 N W V U N N
WB
WM
3 4
S1
S1 N
MAINS OVEN VA P.
JP5
Jumper 5
6 h
12 h
24/7
LSG
Contactor box
STB
PE
P max. 9 kW
STB
fan light
L N L N
NL1 L2 L3
L1 L2 L3 N W V U N N
WB
WM
potentialfreier
Kontakt
3 4
S1
S1 N
Saunaofen
Sauna heater
Sensorbus
Saunabus
reserviert
Leuchte/light Lüfter/fan
Bankfühler/2nd Sensor
Ofenfühler/Sensor
Leistungsteil
Main unit (relay box)
Relais box
Силовой блок
B
Steckeranschluß Fühler
Sensor plug connector
weiß/white
grün/green
braun/brown
Bedienteil
Control panel
Tableau de commande
Панель управления
LSG
3x16A
Terminal layout on the main board
(relay box)
Installation diagram Emotec D / Emostyle D/Di
reserved
Fan / Phase
Fan / Neutral
Light / Phase
Light / Neutral
volt-free contact 16 A
Neutral heater
Neutral mains
Power supply phase 1
Power supply phase 2
Power supply phase 3
Output heater phase 1
Output heater phase 2
Output heater phase 3
Power
extension LSG
Schaltlasterweiterung
LSG, optional
Power extension,
optional
Sensor Bus
RJ 10
Sauna Bus
RJ 12
overheating
limiter fuse
Jumpers are supplied
with the default
setting to 6 hours
Other manuals for EmoStyle Di
1
This manual suits for next models
3
Table of contents
Other EOS Control Unit manuals

EOS
EOS EmoTouch 3 User manual

EOS
EOS EMOTEC DC 9000 User manual

EOS
EOS Emotec D Guide

EOS
EOS SBM GLT KNX User manual

EOS
EOS EmoToych II AF User manual

EOS
EOS EmoTouch II + User manual

EOS
EOS EmoTec LSG 09R Planning guide

EOS
EOS EMOTEC L 09 Relay User manual

EOS
EOS ECON A1 User manual

EOS
EOS ECON H3 User guide