manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ETI
  6. •
  7. Thermometer
  8. •
  9. ETI 810-275 User manual

ETI 810-275 User manual

810-275/17.02.15
Waterproof
Thermometer
supplied by
Electronic Temperature Instruments Ltd
Worthing · West Sussex · BN14 8HQ
tel: 01903 202151 · email: [email protected]
www.etiltd.com
estabilizar, dependendo da natureza da medição.
MAX/MIN - Premir o botão MAX/MIN para
visualizar a leitura máxima do frigorífico (símbolo
MAX exibido). Premir o botão MAX/MIN para
visualizar a leitura mínima (símbolo MIN exibido).
Premir o botão MAX/MIN novamente para
retornar às leituras normais. Segurar o botão
MAX/MIN durante três segundos para reconfigurar
a memória de temperatura mínima e máxima.
Note por favor: As leituras Máximas/Mínimas não
serão guardadas, por isso, o desligar do termómetro
eliminará as leituras Máximas/Mínimas.
°C/°F - Premir o botão °C/°F no verso do instrumento
para mudar entre graus Centígrados e graus
Fahrenheit.
SUBSTITUIÇÃO DA PILHA - Substitua as baterias
quando visualizar 'Bat', usando uma bateria CR2032
ou equivalente 3V. A bateria está localizada por baixo
da respectiva tampa na parte de trás do instrumento.
ES - FUNCIONAMIENTO - El instrumento se enciende
presionando el botón ON/OFF situado en la parte
delantera del instrumento. Insertar la sonda en la
sustancia cuya temperatura se desea determinar.
La temperatura puede tardar unos segundos en
estabilizarse en el visualizador dependiendo de la
sustancia.
MÁX/MÍN - Pulsar el botón MAX/MIN para visualizar
la temperatura máxima registrada (el símbolo MAX
aparecerá en el visualizador). Pulsar el botón MAX/
MIN una segunda vez para visualizar la temperatura
mínima registrada (aparecerá el símbolo MIN). Pulsar
el botón MAX/MIN una tercera vez para retornar a
la temperatura normal. Mantener pulsado MAX/MIN
por tres segundos para reponer a cero la memoria de
las temperaturas mínima y máxima. Observación:
Las temperaturas MAX/MIN se borrarán de la
memoria cuando se apague el termómetro.
ºC/ºF - Pulsar el botón ºC/ºF para cambiar la escala
de temperaturas de Centígrados a Fahrenheit y
viceversa.
CAMBIO DE PILA - Cuando aparezca 'Bat' en la
pantalla, debe cambiar las baterías. Utilice siempre
baterías CR2032 o equivalentes a 3V. Para acceder a
las baterías, retire la tapa situada en la parte posterior
del instrumento.
Operating Instructions
order code: 810-275
Gerät einzuschalten, die ON/OFF Taste auf der
Vorderseite des Gerätes drücken. Messfühler in das
Messgut stecken. Je nach Art der Messung kann die
Stabilisierung des Messergebnisses einige Sekunden
dauern.
MAX/MIN - Die MAX/MIN-Taste drücken, um die
höchste gemessene Temperatur anzuzeigen (auf dem
Display erscheint MAX). Die MAX/MIN-Taste erneut
drücken, um die niedrigste gemessene Temperatur
anzuzeigen (auf dem Display erscheint MIN). Durch
nochmaliges Drücken der MAX/MIN-Taste kehren
Sie zur normalen Anzeige zurück. MAX/MIN-Taste
drei Sekunden lang gedrückt halten, um den
Minimalwert-/Maximalwertspeicher zurückzusetzen.
Achtung: Die Maximal-bzw. Minimalmesswerte
werden nicht permanent gespeichert. Beim
Ausschalten des Thermometers werden die Maximal-/
Minimalmesswerte gelöscht.
°C/°F - Zum Umschalten von °C (Celsius) auf °F
(Fahrenheit) die °C/°F-Taste auf der Rückseite des
Gerätes drücken.
BATTERIEWECHSEL - Ersetzen Sie die Batterien,
wenn 'Bat' angezeigt wird. Verwenden Sie dafür
eine CR2032-Knopfzelle oder eine äquivalente
Batterie mit 3 V. Die Batterie befindet sich unter der
Batterieabdeckung auf der Rückseite des Geräts.
IT - FUNZIONAMENTO DELLO STRUMENTO - Lo
strumento si accende premendo il pulsante ON/
OFF collocato sulla parte anteriore dello strumento.
Inserire la sonda nella sostanza da misurare. La
lettura dello strumento può impiegare qualche
secondo a stabilizzarsi a seconda della natura della
misurazione
MAX/MIN - Premere il pulsante MAX/MIN per
visualizzare la lettura massima e apparirà il simbolo
MAX. Premere di nuovo il pulsante MAX/MIN per
visualizzare la lettura minima e apparirà il simbolo
MIN. Premere di nuovo il pulsante MAX/MIN per
ritornare alle letture normali. Per tornare a impostare
la memoria della temperatura minima e massima
tenere premuto il pulsante MAX/MIN per tre secondi.
NB: Le letture Max/Min non vengono salvate per
cui se si spegne il termometro le letture max/min
verranno cancellate.
°C/°F - Per passare da Centigradi a Fahrenheit
premere il pulsante °C/°F sulla parte posteriore
dello strumento.
SOSTITUZIONE DELLA BATTERIA - ostituire le
batterie quando viene visualizzato 'Bat' utilizzando
una batteria CR2032 o 3V equivalente. La batteria
è situata sotto il coperchio della batteria nel retro
dello strumento.
PT - FUNCIONAMENTO DO INSTRUMENTO - O
instrumento é ligado premindo o botão ON/OFF
(LIGAR/DESLIGAR) situado na frente do instrumento.
Aplique a sonda à substância a ser medida. A leitura
do instrumento pode demorar alguns segundos a
INSTRUMENT OPERATION - The instrument is
switched on by pressing the ON/OFF button located
on the front of the instrument. Insert the probe into the
substance being measured. The instrument reading
may take a few seconds to stabilise, depending on
the nature of the measurement.
MAX/MIN - Press the MAX/MIN button to display
the maximum reading (MAX symbol displayed).
Press the MAX/MIN button again to display the
minimum reading (MIN symbol displayed). Press
MAX/MIN button again to return to normal
readings. Hold MAX/MIN for three seconds to reset
minimum and maximum temperature memory.
Please note: Max/Min readings are not saved so
switching the thermometer off will clear the max/
min readings.
°C/°F - Press the °C/°F button on the rear of the
instrument to switch between Centigrade and
Fahrenheit.
BATTERY REPLACEMENT - Replace the battery
immediately when 'Bat' is displayed, using a CR2032
battery or 3V equivalent. The battery is located under
the battery cover at the rear of the instrument.
EMC/RFI - Instrument performance may be affected
if operated within a high frequency radio field,
such as near a mobile phone, or if subjected to an
electrostatic shock.
GUARANTEE - This instrument carries a one-
year limited guarantee against manufacturing
defects. Full details of liability are available at
www.etiltd.com/terms.
FR - FONCTIONNEMENT DU THERMOMÈTRE -
Mettez le thermomètre en marche en appuyant sur
le bouton ON/OFF situé sur sa face avant. Insérez
la sonde dans l’aliment voulu. En fonction de sa
nature, quelques secondes peuvent être nécessaires
à la mesure pour se stabiliser.
MAX/MIN - Appuyez sur le bouton MAX/MIN pour
afficher la valeur mesurée maximale (symbole MAX
affiché). Appuyez à nouveau sur le bouton MAX/MIN
pour afficher la valeur mesurée minimale (symbole
MIN affiché). Appuyez à nouveau sur le bouton MAX/
MIN pour revenir aux valeurs mesurées normales.
Maintenez enfoncé MAX/MIN pendant trois secondes
pour réinitialiser la mémoire de température
minimale et maximale. Remarque: les valeurs
Max./Min. ne sont pas enregistrées ; en conséquence,
la mise hors tension du thermomètre les efface.
°C/°F - Appuyez sur le bouton °C/°F à l’arrière
du thermomètre pour basculer entre Celsius et
Fahrenheit.
REMPLACEMENT DE LA PILE - Remplacer les piles
lorsque 'Bat' s’affiche, utiliser une pile CR2032
ou une pile 3V équivalente. La pile se trouve sous
le couvercle du logement à pile, à l’arrière du
thermomètre.
DE - BEDIENUNG DES THERMOMETER - Um das

Other ETI Thermometer manuals

ETI 810-140 User manual

ETI

ETI 810-140 User manual

ETI THERMAPEN IR BLUE User manual

ETI

ETI THERMAPEN IR BLUE User manual

ETI DISHTEMP User manual

ETI

ETI DISHTEMP User manual

ETI 800-850 User manual

ETI

ETI 800-850 User manual

ETI Therma 22 Plus User manual

ETI

ETI Therma 22 Plus User manual

ETI THERMAQ WIFI User manual

ETI

ETI THERMAQ WIFI User manual

ETI SuperFast Thermapen 3 User manual

ETI

ETI SuperFast Thermapen 3 User manual

ETI Thermapen Blue with Bluetooth IE Wireless... User manual

ETI

ETI Thermapen Blue with Bluetooth IE Wireless... User manual

ETI ThermaData Logger User manual

ETI

ETI ThermaData Logger User manual

ETI SAF-T-LOG User manual

ETI

ETI SAF-T-LOG User manual

ETI 810-421 User manual

ETI

ETI 810-421 User manual

ETI Raytemp 8 User manual

ETI

ETI Raytemp 8 User manual

ETI Mini RayTemp User manual

ETI

ETI Mini RayTemp User manual

ETI TEMPTEST 2 User manual

ETI

ETI TEMPTEST 2 User manual

ETI ThermoPop User manual

ETI

ETI ThermoPop User manual

ETI RAYTEMP 6 User manual

ETI

ETI RAYTEMP 6 User manual

ETI THERMAQ BLUE User manual

ETI

ETI THERMAQ BLUE User manual

ETI THERMAQ BLUE User manual

ETI

ETI THERMAQ BLUE User manual

ETI Precision User manual

ETI

ETI Precision User manual

ETI ThermaStick Series User manual

ETI

ETI ThermaStick Series User manual

ETI 810-125 User manual

ETI

ETI 810-125 User manual

ETI TempTest 1 User manual

ETI

ETI TempTest 1 User manual

ETI 800-805 User manual

ETI

ETI 800-805 User manual

ETI THERMALITE 2 User manual

ETI

ETI THERMALITE 2 User manual

Popular Thermometer manuals by other brands

Oregon Scientific AW133 user manual

Oregon Scientific

Oregon Scientific AW133 user manual

Bel-art B60901-0100 manual

Bel-art

Bel-art B60901-0100 manual

Menuett 943108 operating instructions

Menuett

Menuett 943108 operating instructions

Rossmax RA600 manual

Rossmax

Rossmax RA600 manual

Hubert 70741 instruction manual

Hubert

Hubert 70741 instruction manual

Welch Allyn 9000 Technical manual

Welch Allyn

Welch Allyn 9000 Technical manual

Digoo DG-TH1100 Indoor Thermometer Pair quick start guide

Digoo

Digoo DG-TH1100 Indoor Thermometer Pair quick start guide

Ascon tecnologic e30V operating instructions

Ascon tecnologic

Ascon tecnologic e30V operating instructions

Sanitas SFT 01 quick start guide

Sanitas

Sanitas SFT 01 quick start guide

Viproud FC-IR109 user manual

Viproud

Viproud FC-IR109 user manual

Omega OS3700 series user guide

Omega

Omega OS3700 series user guide

PCE Instruments PCE-889 operating manual

PCE Instruments

PCE Instruments PCE-889 operating manual

Center 520 instruction manual

Center

Center 520 instruction manual

Taylor 522 instruction manual

Taylor

Taylor 522 instruction manual

AccuMed AT2103 manual

AccuMed

AccuMed AT2103 manual

Maverick ET-705C instruction manual

Maverick

Maverick ET-705C instruction manual

Greenlee TG-100 instruction manual

Greenlee

Greenlee TG-100 instruction manual

Beurer Janosch JFT 60 operating instructions

Beurer

Beurer Janosch JFT 60 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.