ETI SHT-1 User manual

SHT-1
SHT-1/2
SHT-3
SHT-3/2
Digital time switch
E
N
H
U
E
N
P
L
R
U
S
L
O
HRV
SRP
BOS
D
E

- 2 -
3
4
5
6
7
8
10
11
12
13
14
15
16
17
18
19
20
Warning ..........................................................................................................
Characteristics ...............................................................................................
Technical parameters ....................................................................................
Description ....................................................................................................
Symbol, Connection ......................................................................................
Versions of time switches, Load ...................................................................
Control ............................................................................................................
Mode precendence, Manual output control ...............................................
Program setting .............................................................................................
Program adjustment .....................................................................................
Program deleting, Deleting of all programs ...............................................
Date and time setting ...................................................................................
Setting of programmed/random mode .......................................................
Setting of pulse/cyclic mode interval ..........................................................
Holiday mode ................................................................................................
Exit from menu, Reset ...................................................................................
Example of programming .............................................................................
Content

- 3 -
E
N
E
N
Warning
Device is constructed for connection in 1-phase main
alternating current voltage and must be installed ac-
cording to norms valid in the state of application.
Connection according to the details in this direc-
tion. Installation, connection, setting and servicing should be
installed by qualied electrician sta only, who has learnt these
instruction and functions of the device. This device contains pro-
tection against overvoltage peaks and disturbancies in supply.
For correct function of the protection of this device there must
be suitable protections of higher degree (A,B,C) installed in front
of them. According to standards elimination of disturbancies
must be ensured. Before installation the main switch must be
in position “OFF” and the device should be de-energized. Don´t
install the device to sources of excessive electro-magnetic inter-
ference. By correct installation ensure ideal air circulation so in
case of permanent operation and higher ambient temperature
the maximal operating temperature of the device is not exceed-
ed. For installation and setting use screw-driver cca 2 mm. The
device is fully-electronic - installation should be carried out ac-
cording to this fact. Non-problematic function depends also on
the way of transportation, storing and handling. In case of any
signs of destruction, deformation, non-function or missing part,
don´t install and claim at your seller it is possible to dismount
the device after its lifetime, recycle, or store in protective dump.

- 4 -
Characteristics
- Serves for controlling of various types of appliances in depend-
ance on real time (automation-switching of heating, pumps,
ventilation etc.). Appliances can be operated in concrete periodic
time cycles or according a pre-set program (depends on type, see
the chart Versions of time switches).
- SHT-1, SHT-3: 1-channel version.
- SHT-1/2, SHT-3/2: 2-channel version (to each channel can be as-
signed an individual program).
- Possibility to control two independent circuits.
- By SHT-3, SHT-3/2 is not possible to integrate daily and night
mode on one channel. By SHT-3/2 is possible to set a dierent
mode on each channel.
- Setting of switching by:
- program (PROG) - switching according programs set in SET 1 .
Possibility to set the repeat every minute or every hour.
- random (AUTO ) - random switching in 10-120 min interval.
- permanently manualy .
- Switching modes (OUT):
- OUT ON - normal - 2 positions in memory (close /open), shortest
time of closing is 1 min.
- OUT ON - cyclic - 2 positions in memory (pulse/delay), range
1-99s.
- OUT ON - pulse - 1 position in memory, range 1-99s.
- OUT OFF - turn o the switching mode.
- Set time of pulse/delay is on one channel the same for all pro-
grams (it is not possible to set more pulses with dierent dura-
tions on one channel).
- “Holiday mode - “ - possibility to choose the period, when the
device will be not switching according a standard program and
will be blocked for the pre-set time.
- 100 memory positions (by SHT-1/2 and SHT-3/2 are those 100 po-
sitions common for both channels).
- Programming of device can be realize even under voltage and
also even in back-up mode.
- Output relays operates only under voltage.
- Automatic change-over between summer/winter time (setting is
for time zone GTM+1:00).
- Back-lighted LCD display.
- Easy and quick setting by 4 control buttons.
- Sealable transparent cover of the front panel.
- Time switch is back-up with in-built lithium element, which saves
data during voltage failure. Back-up time reserve - up to 3 years.
- Supply voltage: AC 230V or AC/DC 12-240V.
- 2-Module, DIN rail mounting, saddle terminals.
- Device is delivered with pre-programmed actual time, which is
permanently displayed also in back-up mode.

- 5 -
230 UNI
E
N
E
N
Technical parameters
A1 - A2
AC/DC 12-240 V (AC 50-60 Hz)
AC 0.5 - 2 VA / DC 0.4 - 2 W
AC 230V / 50 - 60 Hz
AC max. 14 VA / 2 W
-15 %; +10 %
yes
automatic
1 x changeover (AgSnO2)
2 x changeover (AgSnO2)
16 A / AC1
4000 VA / AC1, 384 W / DC
30 A / <3s
250 V AC1 / 24 V DC
500 mW
> 3x107
> 0.7x105
up to 3 years
max. ±1s/ day at 23°C
1 min.
min. 10 years
1-99s
1-99s
100
daily, weekly
daily, weekly, monthly , yearly
(up to year 2095)
LCD display, with back light
-20.. +55 °C
-30.. +70 °C
4 kV (supply - output)
any
DIN rail EN 60715
IP10 clips, IP40 from front panel
III.
2
solid wire max. 2x 2.5 or 1x 4
with sleeve max. 1x 2.5 or 2x 1.5
90 x 35.6 x 64 mm
(UNI)-130 g, (230)-110 g
(UNI)-143 g, (230)-125 g
EN 61812-1, EN 61010-1
Supply terminals:
Supply voltage:
Consumption:
Supply voltage:
Consumption:
Supply voltage tolerance:
Real time back-up:
Summer/winter time:
Output:
Number of contacts
- SHT-1, SHT-3:
- SHT-1/2, SHT-3/2:
Rated current:
Switching capacity:
Peak current:
Switching voltage:
Min. switching capacity DC:
Mechanical life:
Electrical life (AC1):
Time circuit
Real time back-up when de-
-energi.:
Accuracy:
Minimum interval:
Data stored for:
Cyclic output:
Pulse output:
Program circuit
Number of memory places:
Program (SHT-1; SHT-1/2):
Program(SHT-3, SHT-3/2):
Data readout:
Other information
Operating temperature:
Storage temperature:
Electrical strength:
Operating position:
Mounting:
Protection degree:
Overvoltage category:
Pollution degree:
Max. cable size (mm2):
Dimensions:
Weight
- SHT-1, SHT-3:
- SHT-1/2, SHT-3/2:
Standards:

- 6 -
Supply voltage terminal (A1)
Display with back-light
Place for seal
Output - channel 1 (16-15-18)
Control buttons
Output - channel 2 (26-25-28)
Supply voltage terminal (A2)
Description

- 7 -
Auto
0 6 12 18 24
Prog Man
31 2 4 5 6 7
E
N
E
N
Indicates the day in the week
Indication (1st channel)
Bargraf
Indication (2nd channel)
Indicates 12 / 24 mode
Indicates summer / winter mode
Operating modes indication
Indication of time/date/setting menu
Control button PRG / +
Control button MAN1 / -
Control button OK
Control button MAN2 / ESC
Reset
CONTROL OF A DISPLAY WITH BACKLIGHT
Display is illuminated with a back-light for 10 s from last button press. Permanent on / o is activated by synchronic press of buttons
MAN, ESC, OK.
After permanent on/o activation, display will ash shortly.

- 8 -
SHT-1/2
SHT-3/2
Un
A2 26 25 28
A1 16 15 18
Un
A2
A1 16 15 18
SHT-1
SHT-3
SHT-1
SHT-3
SHT-1/2
SHT-3/2
15 25
16
A2
A1 18 26 28
1 5
16
A2
A1 18
Symbol
Connection

- 9 -
cos φ ≥ 0.95 M M
M M
HAL.230V
K
AC12
x
AC1
250V / 16A
AC2
250V / 5A
AC3
250V / 3A
AC5b
1000W
AC6a
x
AC7b
250V / 3A
DC14
x
AC13
x
AC14
250V / 6A
AC15
250V / 6A
DC1
24V / 10A
DC5
24V / 2A
DC12
24V / 6A
DC13
24V / 2A
DC3
24V / 3A
E
N
E
N
Versions of time switches
Load
AC5a
Uncompensated
230V / 3A (690VA)
AC5a
Compensated
230V / 3A (690VA)
max. input C=14uF
Type of load
Contact material AgSnO2,
Contact 16A
Type of load
Contact material AgSnO2,
Contact 16A
Type of load
Contact material AgSnO2,
Contact 16A
Type of product
output time program
1 channel 2 channels day week month year
SHT-1 zzz
SHT-1/2 zzz
SHT-3 z zzzz
SHT-3/2 zzzzz

- 10 -
0 6 12 18 24
Prog
0 6 12 18 24
0 6 12 18 24
Man
0 6 12 18 24
0 6 12 18 24
0 6 12 18 24
setting, adjustment
and program deleting
setting of programmed /
random mode
holiday mode
exit from menu
date and time setting
Control Device diers short and long button press. In the manual marked as:
- short button press (<1s)
- long button press (>1s)
c/d- number indicates button press sequence
After 30 s of inactivity (from the last press of any button) will device automatically
returns into starting menu.
- entrance into programming menu
- browsing in menu
- setting of values
- quick shifting during setting of values
- entrance into required menu
- conrmation
- entrance into chosen program (EDIT)
- one level up
- back to the starting menu
setting of pulse /cyclic mode
interval

- 11 -
0 6 12 18 24
4
0 6 12 18 24
4
0 6 12 18 24
Man
4
0 6 12 18 24
Man
4
E
N
E
N
- is superior to other set modes
Precendence of controlling
modes
display output mode
ON / OFF manual control
ON / OFF holiday mode
ON / OFF auto random mode for switching
ON / OFF / pulse-cyclic mode
ON / OFF normal mode Prog
highest priority of
controlling mode
lowest priority of
controlling mode
Mode precendence
Manual output control
- controls channel 1
- controls channel 2
(by SHT-1/2 and SHT-3/2)
relay orelay on

0 6 12 18 24
0 6 12 18 24
0 6 12 18 24
06 0 6 12 18 24
0 6 12 18 24
Man
4
- 12 -
0 6 12 18 24
Prog
0 6 12 18 24
0 6 12 18 24
0 6 12 18 24
d
c
d
c
d
c
0 6 12 18 24
d
c
0 6 12 18 24
d
c
SET 1
0 6 12 18 24
Prog
0 6 12 18 24
0 6 12 18 24
0 6 12 18 24
0 6 12 18 24
7
24
6
24
24
5
4
24
3
24
2
24
06
1
0 6 12 18 24
d
c
0 6 12 18 24 0 6 12 18 24
............
Program setting
ADD - add a new
program
only by daily
mode: ON/OFF
- setting of the
program activity
in concrete day of
the week
setting of hour
and minute of
program
start /end *
only by yearly
mode: setting
of year, month
and day
OUT - setting of
switching mode
- OUT ON - normal
- OUT ON - cyclic
- OUT ON - pulse
- OUT OFF - turn o
the switching mode
- by SHT-3 and
SHT-3/2
- selection of daily
/ night mode
- by SHT1/2 and
SHT3/2 - selection
of channel
If the program memory is full, display announces it by
notice FULL.
* If “- -”(2 dashes) is set as the hour or minute value instead
of a numerical value, the start / end of the program will be
repeated every hour or every minute.

0 6 12 18 24
0 6 12 18 24
0 6 12 18 24
06 0 6 12 18 24
0 6 12 18 24
Man
4
- 13 -
SET 1
d
c
d
c
0 6 12 18 24
o
0 6 12 18 24
d
c
0 6 12 18 24
Prog
c
0 6 12 18 24
4
0 6 12 18 24
d
c
0 6 12 18 24
d
c
d
c
0 6 12 18 24
0 6 12 18 24
0 6 12 18 24
0 6 12 18 24
0 6 12 18 24
0 6 12 18 24
7
24
6
24
24
5
4
24
3
24
2
24
06
1
0 6 12 18 24
d
c
0 6 12 18 24
0 6 12 18 24
Man
4
E
N
E
N
Program adjustment
only by daily
mode:
ON/OFF -
selection /
adjustment of
program activity
in concrete day
of the week
time
adjustment
(hours /
minutes)
OUT - selection
/ adjustment of
switching mode
by SHT-3 and
SHT-3/2
selection /
adjustment of set
mode
by SHT-1/2 and
SHT-3/2
selection /
adjustment of
channel
selection /
entrance into
chosen program
EDIT - adjustment
of already saved
programs
- long press (>1s)
- short press (<1s)
c/d- press sequence
only by yearly
mode: adjusting
of date (year,
month and day)

0 6 12 18 24
Man
4
- 14 -
SET 1
0 6 12 18 24
0 6 12 18 24
d
c
0 6 12 18 24
Prog
0 6 12 18 24
o
c
0 6 12 18 24
Man
4
0 6 12 18 24
0 6 12 18 24
4
0 6 12 18 24
Man
4
Program deleting Deleting of all programs
DEL - deleting
of individual
programs
- program
selection
- long press OK -
deleting of chosen
program
in starting menu
(time is shown on
display) - press
simultaneously
button PRG and OK
and display
announces a
notice ALL
press button OK
to complete the
deleting of all set
programs

0 6 12 18 24 0 6 12 18 24
0 6 12 18 24
Man
4
- 15 -
SET 2
0 6 12 18 240 6 12 18 24
d
c
0 6 12 18 24
d
c
0 6 12 18 24
d
c
0 6 12 18 24
d
c
0 6 12 18 24
d
c
0 6 12 18 24
Prog
0 6 12 18 24
0 6 12 18 24
d
c
0 6 12 18 24
d
c
E
N
E
N
Date and time setting
activation of
changeover
between summer/
winter time
minutes
setting
hour
setting
setting of time
in 24 or 12 hour
format
day
setting
month
setting
year
setting
- long press (>1s)
- short press (<1s)
c/d- press sequence

06
0 6 12 18 24
Man
4
- 16 -
SET 3
0 6 12 18 24
Man
0 6 12 18 24
d
c
Auto
0 6 12 18 24
0 6 12 18 24
Prog
d
c
0 6 12 18 24
Prog
0 6 12 18 24
Man
Setting of programmed / random mode
In starting mode by chosen channel ashs symbol Prog or on display.
(Automatically preset switching according PROG).
PROG - relay
is switching
according
programs set in
menu SET 1
AUTO - relay
is switching
randomly in
10-120 min
interval
- by SHT-1/2 and
SHT-3/2
- selection of
channel

0 6 12 18 24
Man
4
- 17 -
0 6 12 18 240 6 12 18 24
d
c
0 6 12 18 24
d
c
SET 4
0 6 12 18 24
Prog
0 6 12 18 24
06
0 6 12 18 24
d
c
E
N
E
N
Setting of pulse / cyclic mode interval
- by SHT-1/2 and
SHT-3/2
selection of
channel
- setting of
pulse /cycle
duration
- setting of
delay / cycle
duration (by
- pulse mode do
not set)
Setting of time of pulse / cyclic mode switching is realized by SET 1 .
-
long press
(>1s)
- short press (<1s)
c/d- press sequence

24
0 6 12 18 24
Man
4
- 18 -
0 6 12 18 24
Prog
SET 5
0 6 12 18 240 6 12 18 24
d
c
0 6 12 18 24
d
c
0 6 12 18 24
d
c
0 6 12 18 24
d
c
0 6 12 18 24
d
c
0 6 12 18 24
d
c
0 6 12 18 24
d
c
0 6 12 18 24
Holiday mode
In the starting mode during the activation of holiday mode, ashs symbol on display.
holiday mode
ending day setting
holiday mode
ending month
setting
holiday mode
ending year
setting
holiday mode
starting day
setting
holiday mode
starting month
setting
holiday mode
starting year
setting
holiday mode
setting

0 6 12 18 24
Man
4
- 19 -
End
0 6 12 18 24
Prog
0 6 12 18 24
0 6 12 18 24 0 6 12 18 24 0 6 12 18 24 0 6 12 18 24
1
0 6 12 18 24
Man
4
0
E
N
E
N
- return to the starting mode
Exit from menu
Activated by, covered RESET button, short press with blunt spike
(with max. 2 mm diameter).
After press, information about type of device and rmware ver-
sion will displayed for 3 s and then device performs in starting
mode.
Reset will delete an actual time, set time of pulse/cyclic mode and
all temporary functions (manual or random switch output).
Reset will save all set programs.
-
long press
(>1s)
- short press (<1s)
c/d- press sequence
Reset

0 6 12 18 24
0 6 12 18 24
Man
4
- 20 -
0 6 12 18 24
Prog
0 6 12 18 24
0 6 12 18 24
0 6 12 18 24
d
c
0 6 12 18 24
d
c
d
c
0 6 12 18 24
............
7
24
6
0 6 12 18 24
d
c
24
5
4
24
3
24
2
24
06
1
0 6 12 18 24
0 6 12 18 24
d
c
Example of programming
Setting of SHT-3/2 to be activated from Monday till Friday at 8:00 by program 0 ( ) , and deactivated from Monday till Friday at
16:30 by program 1 ( ).
setting of switching on
program 0 channel 1 daily
program
turn on
a normal
mode
time of
turning on
setting of
activity
Mo-Fri
turning o
the activity
Sat-Sun
save
starting
menu program-
ming
add the
program
Other manuals for SHT-1
1
This manual suits for next models
10
Table of contents
Other ETI Timer manuals