FAAC E850S User manual

Kit E850S
Translation of the original instructions

FAAC S.p.A. Soc. Unipersonale
Via Calari, 10 - 40069 Zola Predosa BOLOGNA - ITALY
Tel. +39 051 61724 - Fax +39 051 758518
www.faac.it - www.faacgroup.com
© Copyright FAAC S.p.A. dal 2017. Tutti i diritti riservati.
Nessuna parte di questo manuale può essere riprodotta, archiviata, distribuita a terzi
né altrimenti copiata, in qualsiasi formato e con qualsiasi mezzo, sia esso elettronico,
meccanico o tramite fotocopia, senza il preventivo consenso scritto di FAAC S.p.A.
Tutti i nomi e i marchi citati sono di proprietà dei rispettivi fabbricanti.
I clienti possono effettuare copie per esclusivo utilizzo proprio.
Questo manuale è stato pubblicato nel 2017.
© Copyright FAAC S.p.A. from 2017. All rights reserved.
No part of this manual may be reproduced, archived, distributed to third parties nor
copied in any other way, in any format and with any means, be it electronic, mechanical
or by photocopying, without prior written authorisation by FAAC S.p.A.
All names and trademarks mentioned are the property of their respective manu-
facturers.
Customers may make copies exclusively for their own use.
This manual was published in 2017.
© Copyright FAAC S.p.A. depuis 2017. Tous droits réservés.
Aucune partie de ce manuel ne peut être reproduite, archivée ou distribuée à des tiers
ni copiée, sous tout format et avec tout moyen, qu’il soit électronique, mécanique ou
par photocopie, sans le consentement écrit préalable de FAAC S.p.A.
Tous les noms et les marques cités sont la propriété de leurs fabricants respectifs.
Les clients peuvent faire des copies pour leur usage exclusif.
Ce manuel a été publié en 2017.
© Copyright FAAC S.p.A. ab dem 2017. Alle Rechte vorbehalten.
Kein Teil dieses Handbuchs darf reproduziert, gespeichert, an Dritte weitergegeben
oder sonst auf eine beliebige Art in einem beliebigen Format und mit beliebigen
Mitteln kopiert werden, weder mit elektronischen, noch mechanischen oder durch
Fotokopieren, ohne die Genehmigung von FAAC S.p.A.
Alle erwähnten Namen und Marken sind Eigentum der jeweiligen Hersteller.
Die Kunden dürfen nur für den Eigengebrauch Kopien anfertigen.
Dieses Handbuch wurde 2017 veröffentlicht.
© Copyright FAAC S.p.A. del 2017. Todos los derechos están reservados.
No puede reproducirse, archivarse, distribuirse a terceros ni copiarse de ningún modo,
ninguna parte de este manual, con medios mecánicos o mediante fotocopia, sin el
permiso previo por escrito de FAAC S.p.A.
Todos los nombre y las marcas citadas son de propiedad de los respectivos fabricantes.
Los clientes pueden realizar copias para su uso exclusivo.
Este manual se ha publicado en 2017.
© Copyright FAAC S.p.A. van 2017. Alle rechten voorbehouden.
Niets uit deze handleiding mag gereproduceerd, gearchiveerd, aan derden openbaar
gemaakt of op andere wijze gekopieerd worden, in om het even welke vorm en
met geen enkel middel, noch elektronisch, mechanisch of via fotokopiëren, zonder
schrfitelijke toestemming vooraf van FAAC S.p.A.
Alle vermelde namen en merken zijn eigendom van de respectievelijke fabrikanten.
De klanten mogen kopieën maken die enkel voor eigen gebruik bestemd zijn.
Dez handleiding werd in 2017 gepubliceerd.

Kit E850S 3 532181 - Rev.A
Translation of the original instructions ENGLISH
CONTENTS
1. INTRODUCTION TO THE INSTRUCTION MANUAL........... 4
1.1 Meaning of the symbols used................................... 4
1.2 Tools required ..................................................... 4
2. KIT E850S............................................................ 5
2.1 Intended use ...................................................... 5
2.2 Unauthorised use................................................. 5
2.3 Technical characteristics ......................................... 5
2.4 Component identification ....................................... 5
3. PRELIMINARY OPERATIONS..................................... 7
3.1 Removing the cover .............................................. 7
3.2 Disconnecting the electronic board E850...................... 7
3.3 Removing the original frame.................................... 8
3.4 Disconnect the limit switches ................................... 8
4. INSTALLATION ..................................................... 9
4.1 Connecting the new limit switch cable ........................ 9
4.2 Connecting the new electric motor cable ..................... 9
4.3 Installing the new frame........................................10
4.4 Removing the plastic covers....................................10
4.5 Connections to the board E850S...............................11
5. STARTUP.......................................................... 14
5.1 Manual operation................................................14
5.2 Limit switch adjustment ........................................15
5.3 Programming ....................................................17
6. PUTTING INTO SERVICE ........................................ 18
6.1 Final checks ......................................................18
7. DIAGNOSTICS .................................................... 18
7.1 LEDs check .......................................................18
7.2 Status of the automation .......................................18
EU DECLARATION OF CONFORMITY
The Manufacturer
Company name: FAAC S.p.A. Soc. Unipersonale
Address: Via Calari, 10 - 40069 Zola Predosa BOLOGNA - ITALY
hereby declares on his sole responsibility that the following products:
Description: The control board
Model: E850S
comply with the following applicable EU legislations:
2014/35/EU
2014/30/EU
2011/65/EU
Furthermore, the following harmonised standards have been applied:
EN 60335-1:2012 + A11:2014
EN61000-6-2:2005
EN61000-6-3:2007 + A1:2011
Bologna, Italy 20-03-2017 CEO

Kit E850S 4 532181 - Rev.A
Translation of the original instructions ENGLISH
1. INTRODUCTION TO THE INSTRUCTION MANUAL
1.2 TOOLS REQUIRED
1 Symbols: notes and warnings on the instructions
FWARNING ELECTRIC SHOCK HAZARD -The procedure or step described must
be carried out following the instructions provided and according to the
applicable safety regulations
!WARNING, PERSONAL INJURY HAZARD OR RISK OF DAMAGE TO COMPO
NENTS - The procedure or step described must be carried out following the
instructions provided and according to the applicable safety regulations.
WARNING - Details and specifications that must be complied with in order to
ensure that the system operates correctly.
FIGURE E.g.: 1-3 see Figure 1 - detail 3.
TABLE E.g.: 1 see Table 1.
§CHAPTER/SECTION E.g.: §1.1 see section 1.1.
Automatic operation - automation locked
Manual operation - automation unlocked
1.1 MEANING OF THE SYMBOLS USED
2 Symbols: safety signs and symbols (EN ISO 7010)
GENERIC HAZARD
Personal injury hazard or risk of damage to components
ELECTROCUTION HAZARD
Risk of electric shock from live parts
CRUSHING HAZARD
Risk of crushing of hands/feet due to the presence of heavy parts
CUTTING/AMPUTATION/PIERCING HAZARD
Cutting hazard due to the presence of sharp components or the use of
pointed/sharp tools (drill)
SHEARING HAZARD
Risk of shearing due to moving parts
RISK OF IMPACT/CRUSHING
Risk of impact or crushing due to moving parts
RISK OF TRIPPING
Risk of tripping over due to the presence of thresholds higher than 5mm
3 Symbols: personal protective equipment
Personal protective equipment must be worn to protect against hazards (e.g. crushing,
cutting, shearing etc.):
Obligation to wear work gloves
Obligation to wear safety footwear
! Use appropriate tools and equipment in working environments which
comply with applicable legislation.
4 Symbols: work tools
8 ; 19
HEX SPANNER of size indicated
FLAT SCREWDRIVER
PHILLIPS SCREWDRIVER
4
ALLEN KEY with ROUND HEAD of the size(s) indicated
ELECTRICIAN'S SCISSORS
WIRE STRIPPER/TERMINAL CRIMPER

Kit E850S 5 532181 - Rev.A
1
1
2
3
4
5
Translation of the original instructions ENGLISH
2.4 COMPONENT IDENTIFICATION
5 Components
1New frame
2Electronic board E850S with plastic covers
3New cable for the integrated limit switches
4New cable for the electric motor
5Fasteners
2. KIT E850S
2.1 INTENDED USE
The Kit is specifically for the FAAC C850 gearmotor.
The Kit allows you to replace the electronic board E850 and inverter
with the electronic board E850S.
2.2 UNAUTHORISED USE
-Uses other than the intended use are prohibited.
-It is prohibited to power the system with energy sources other
than those specified.
-It is prohibited to integrate commercial systems and/or equip-
ment other than those specified, or use them for purposes not
envisaged and authorised by the corresponding manufacturers.
-It is prohibited to use and/or install accessories which have not
been specifically approved by FAAC S.p.A.
-It is prohibited to use the automation before performing com-
missioning.
-It is prohibited to use the automation in the presence of faults
which could compromise safety.
-It is prohibited to use the automation with the fixed and/or
mobile guards removed or altered.
-Do not allow water jets of any type or size to come into direct
contact with the gearmotor.
-Do not expose the gearmotor to corrosive chemical or atmos-
pheric agents.
-Do not use the automation unless the area of operation is free
of persons, animals or objects.
-Do not enter/remain in the area of operation of the automation
while it is moving.
-Do not try to prevent the movement of the automation.
-Do not climb on, hold onto or let yourself be pulled by the
leaf. Do not climb onto or sit on the gearmotor.
-Do not allow children to approach or play in the area of operation
of the automation.
-Do not allow the control devices to be used by anyone who is
not specifically authorised and trained to do so.
-Do not allow the control devices to be used by children or persons
with mental and physical deficiencies unless they are supervised
by an adult who is responsible for their safety.
2.3 TECHNICAL CHARACTERISTICS
The Kit E850S includes:
-the electronic board E850S for controlling the gearmotor C850
-a new support frame for the board E850S
-a new cable for connecting the integrated limit switches
-a new cable for connecting the electric motor
The electronic board E850S has an integrated:
-inverter for programming the opening and closing speeds
independently
-fan for cooling the inverter
-LCD display and 2 buttons for programming the functions

Kit E850S 6 532181 - Rev.A
PE N L
BRAKE
BRAKE
LAMP
LAMP
OPEN B
OPEN A
SAFE
OPEN
FSW CL
FSW OP
STOP
LOCK
COM
-
W.L.
COM
+24V
NC
NO
PE
N
L
U
V
W
W
V
U
MOTOR
OPEN SX OPEN DX
LIMIT
SWITCH SX
FAN
FAIL SAFE
M
3
OP
R.OP
CL
R.CL
LIMIT
SWITCH DX
ENTER UP/DWN
RADIO
RESET
T10A
230V~
30W
24V
0.2A
+24V
0.5A max
+
-
2
F1
J1
J2
J3 J4
J5 JP1
DISPLAY
P1 P2
J7
J6
JP2
JP3
DL5
DL7
DL6
DL8
J8
P3
DL9
DL10
DL11
DL12
DL13
DL14
DL15
Translation of the original instructions ENGLISH
BOARD E850S
COMPONENTS
E850S
J 1 Power supply terminal board
J 2 Electric brake and flashing light terminal board
J 3 Left opening motor terminal board
J 4 Right opening motor terminal board
J 5 Control devices terminal board
J 6 Failsafe terminal board
J 7 LED and accessories power supply terminal board
J 8 Cooling fan terminal board
JP 1 Connector (5 pin) for radio/decoder board
JP 2 Left opening limit switch connector
JP 3 Right opening limit switch connector
DISPLAY Programming display
P 1 ENTER button
P 2 UP/DWN button
P 3 RESET button
F 1 Power supply fuse T10A
DL 5 Opening limit switch status LED
DL 6 Closing limit switch status LED
DL 7 Opening deceleration status LED
DL 8 Closing deceleration status LED
DL 9 OPEN input status LED
DL 10 OPEN B input status LED
DL 11 OPEN A input status LED
DL 12 SAFE input status LED
DL 13 FSW CL input status LED
DL 14 FSW OP input status LED
DL 15 STOP input status LED
6 Board technical data E850S
Power supply voltage 230 V~(+6% -10%) 50/60 Hz
Max power 18 W
Accessories output voltage 24 V
Max. motor power 1.5 KW
Max. accessories load 500 mA
Max. flashing light load 30 W (230V~)
Ambient operating temperature -20 °C - +55 °C

Kit E850S 7 532181 - Rev.A
3
5
6
7
4
1
1
2
4
3
4
4
Translation of the original instructions ENGLISH
3. PRELIMINARY OPERATIONS
RISKS
PERSONAL PROTECTIVE EQUIPMENT
F Always shut off the power supply before performing any work. If
the disconnect switch is not in view, apply a warning sign stating
“WARNING - Maintenance in Progress”.
3.1 REMOVING THE COVER
1. Unscrew the 4 screws and remove the cover (3).
2. Put the cover and the 4 screws to one side.
3.2 DISCONNECTING THE ELECTRONIC BOARD
E850
1. Disconnect the power supply and earth wires from the C850
(4-1).
2. Unscrew the screws of the plastic cover of the E850 board. Re-
move the plastic cover. (5).
3. Disconnect the limit switch cable from the E850 board. Remove
the limit switch cable from the conduit (6).
4. Unscrew the 4 screws of the electric motor junction box and re-
move the cover (7-1). Put the screws and cover to one side.
5. Remove the 3 nuts that connect the cable lugs of the electric motor
(7-2). Put the nuts to one side.
6. Unscrew the electric motor cable gland
(7-3). Remove the electric motor cable from the cable gland
(7-4).
7. Disconnect the remaining wires from the electronic board
E850. Remove the wires from the conduits.

Kit E850S 8 532181 - Rev.A
4 8
4 8
8 19
9
10
11
1
2
3
Translation of the original instructions ENGLISH
3.3 REMOVING THE ORIGINAL FRAME
1. Unscrew the 2 screws and 2 nuts that fasten the frame to the base
of the operator (8-9).
2. Remove the frame from the base of the operator (10).
3.4 DISCONNECT THE LIMIT SWITCHES
1. Unscrew the 2 screws of the limit switch unit cover Remove the
cover (11-1). Put the cover and screws to one side.
2. Unscrew the cable gland from the limit switch unit (11-2).
3. Disconnect the cable lugs from the micro switches and remove
the limit switch cable from the cable gland (11-3).

Kit E850S 9 532181 - Rev.A
13
19 15
16
17
12
14
1
2
Translation of the original instructions ENGLISH
4. INSTALLATION
RISKS
PERSONAL PROTECTIVE EQUIPMENT
4.1 CONNECTING THE NEW LIMIT SWITCH
CABLE
1. Take the cable gland seal from the Kit as shown in 12-1.
2. Take the new limit switch cable included in the Kit. Make a hole
in the cable gland seal. Insert the cable lugs into the cable gland
seal in the direction shown in 12-2.
3. Slide the cable gland seal along the limit switch cable.
4. Insert the cable lugs into the cable gland of the limit switch unit.
(13).
5. Connect the cable lugs to the micro limit switches. Follow the
colour scheme indicated in 14.
6. Tighten the limit switch unit cable gland (15).
4.2 CONNECTING THE NEW ELECTRIC MOTOR
CABLE
1. Take the new electric motor cable included in the Kit.
2. Insert the ring cable lugs into the electric motor cable gland
(16).
3. Connect the ring cable lugs to the electric motor as follows:
U1 Grey/Black
V1 Blue
W1 Brown
YELLOW
EMPTY
EMPTY
EMPTY
EMPTY
WHITE
GREY
GREEN
BROWN

Kit E850S 10 532181 - Rev.A
4 8
4 8
19
20
21
22
18
12
3
Translation of the original instructions ENGLISH
4.3 INSTALLING THE NEW FRAME
1. Place the new frame on the base in the same position as the old
frame 19).
2. Fasten the new frame using the 2 nuts, the 2 screws and the 4
washers included in the Kit (20-21)
4.4 REMOVING THE PLASTIC COVERS
1. Unscrew the 7 fixing screws from the plastic covers of the E850S
board. Remove the plastic covers (22).
2. Put the plastic covers and fixing screws to one side.
4. Tighten the 3 nuts that had been put aside previously onto the
ring cable lugs (18-1).
5. Tighten the electric motor cable gland (18-2).
6. Place the cover on the electric motor junction box. Tighten the
4 screws of the cover that had been put aside previously (18-3).

Kit E850S 11 532181 - Rev.A
23
24 25
JP2
JP3
J5
BRAKE
BRAKE
28
J2
J2
LOCK
COM
29
30
J5
1 1
22
1
2
1
3
26
27
Translation of the original instructions ENGLISH
4.5 CONNECTIONS TO THE BOARD E850S
LIMIT SWITCHES
1. Fasten the limit switch cable to the cable clips on the frame
(23-1).
2. Insert the limit switch cable and the cable gland seal into the hole
indicated in 23-2.
3. Depending on the direction in which the gate opens, plug the
limit switch connector into:
-JP3 if the gate opens towards the left (24)
-JP2 if the gate opens towards the right (25)
The direction in which the gate opens refers to when looking at the
gate while standing in front of the C850 (26,27).
ELECTRIC BRAKE
1. Fasten the electric brake cable to the cable clip on the frame
(28-1).
2. Make a hole in the cable gland seal. Insert the electric brake
cable into the cable gland seal (28-2).
3. Connect the 2 wires of the electric brake to the BRAKE terminals
of J2 (28-3).
The electric brake connection has no polarity.
SAFETY SWITCH ON RELEASE DEVICE
1. Fasten the safety switch cable to the cable clips on the frame
(29-1).
2. Make a hole in the cable gland seal. Insert the safety switch cable
into the cable gland seal (29-2).
3. Connect the 2 wires of the safety switch to the LOCK and COM
terminals of J5 (30).
The safety switch connection has no polarity.
Opening to the left
Opening to the right

Kit E850S 12 532181 - Rev.A
LAMP
LAMP
230V~
30W
J2
J8
JP1
W.L.
-
24V
0.2A
J7
34
35
J2
J7
36
37 38
31
U
V
W
W
V
U
MOTOR
OPEN SX OPEN DX
M
3
32
33
J3 J4
J4
J3
1
Translation of the original instructions ENGLISH
ELECTRIC MOTOR
1. Make a hole in the cable gland seal. Insert the electric motor
cable into the cable gland seal (31-1).
2. Remove the three-pole terminal from J3 or J4.
3. Connect the wires of the motor to the three-pole terminal follow-
ing the colours indicated in 31.
4. Plug the wired three-pole terminal wired into:
-J3 if the gate opens towards the left
-J4 if the gate opens towards the right
The direction in which the gate opens refers to when looking at the
gate while standing in front of the C850.
FLASHING LIGHT
Insert the cable of the flashing light into the cable gland seal indicated
in 33. Connect the flashing light (230 V~, max 30 W model), to
the LAMP terminals of J2 (34).
COOLING FAN
The board cooling fan is connected at the factory to J8 (35).
The fan is powered by a DC voltage. The connection is therefore
polarised.
The fan is started and stopped by the board according to the temper-
ature of the component to be cooled.
RADIO RECEIVER/DECODER BOARD
The quick insertion connector JP1 is specifically for 5-pin FAAC radio
or decoder boards.
It is a polarised type of connector (36).
If a FAAC model RP receiver is used, it is recommended to install the
appropriate external antenna in order to obtain a sufficient range.
LED
The LED remotely indicates the status of the gate as follows:
gate status LED status
closed off
opening on
open on
closing flashing
Insert the cable of the LED into the cable gland seal indicated in
37. Connect the LED (model 24 V", maximum 0.2 A) to the
W.L. and - terminals of J7 (38).
ACCESSORIES POWER SUPPLY
The E850S supplies 24 V"max. 0.5 A for the connected accessories,
on the +24V and - terminals of J7 ().
BROWN
BLUE
GREY/BLACK

Kit E850S 13 532181 - Rev.A
1
2
5
4
3
1
2
SAFE
FSW CL
FSW OP
COM INPUT FAIL SAFE
RADIO
-
COM
+24V
NC
NO
NC
+24V
+24V
FSW CL/FSW OP/SAFE
COM INPUT
COM INPUT
1
2
5
4
3
1
2
NC
+24V
1
2
5
4
3
1
2
NC
+24V COM INPUT
FSW CL/FSW OP/SAFE
+24V
COM INPUT
+24V
COM INPUT
39
J5
J7
J6
Translation of the original instructions ENGLISH
■1 pair of photocells
■2 pairs of photocells
CONTROL DEVICES
Connect the devices to terminal board J5.
Multiple NO contacts on same input must be connected in parallel.
Multiple NC contacts on same input must be connected in series.
TERMINAL BOARD J5
OPEN NOcontact,connectapush-buttonoranothertypeofpulsegeneratorwhich,
byclosing a contact,commands onlythe total openingof theautomation.
OPEN B
NO contact, connect a push-button or another type of pulse generator
which, by closing a contact, commands only the partial opening of the
gate.
Can be configured as CLOSE by setting programming parameter A=1; in
this case it becomes a NO contact to which to connect a push-button or
another type of pulse generator which, by closing a contact, commands
only the closing of the automation.
OPEN A
NO contact, connect a push-button or another type of pulse generator
which, by closing a contact, commands the total opening of the gate.
The effect that subsequent pulses have depends on programming
parameter d.
SAFE
NC contact, connect a safety edge or other safety device which, by
opening a contact, causes the gate to reverse slightly before stopping
the automation. Active during both opening and closing.
FSW CL NC contact, connect a photocell or another device which, by opening a
contact during closing, causes the gate to reverse.
FSW OP
NC contact, connect a photocell or another device which, by opening
a contact during opening, causes the gate to stop; when released, the
gate continues to open.
STOP
NC contact, connect a push-button or another type of pulse generator
which, by openinga contact, causes the automation to stop.The following
cycle takes place slowly until the gate is completely open.
If the input is not used, bridge it with COM INPUT.
LOCK NC contact, used for connecting the safety switch on the release device
at the factory.
COM INPUT Common contacts
If one or more SAFE, FSW CL, FSW OP inputs are not used:
- With Failsafe disabled: bridge the input with COM INPUT
- With Failsafe enabled: see below
FAILSAFE
The failsafe is a test to check the operation of the safety devices con-
nected to the inputs SAFE, FSW CL, FSW OP. It consists of momentar-
ily interrupting the power supply to the devices before any movement
takes place and checking the change in status of the inputs.
In order for the test to be performed, it must be enabled (parameter
b=1).
Terminal board J6 (39) provides a volt free contact (NO or NC) to
be used to interrupt the power supply.
39 shows the connection of one pair and two pairs of photocells
(connected in series). In this configuration, if one or more of the SAFE,
FSW CL, FSW OP inputs are not used, bridge them with NC of J6.

Kit E850S 14 532181 - Rev.A
42 43
44 45
41
PE N L
PE NL
40
J1
1
8
Translation of the original instructions ENGLISH
POWER SUPPLY AND GROUNDING
F Carry out the following operations with the power supply disconnected.
1. Crimp the system earth wire, using the supplied terminal.
2. Install the M5 nut, washer and terminal supplied onto the gear
motor earth connection (40-1). Tighten the nut.
3. Connect the phase and neutral wires of the power supply to ter-
minals L and N respectively of J1 (40).
5. START-UP
RISKS
PERSONAL PROTECTIVE EQUIPMENT
! During operation there is a risk of fingers and hands being trapped
between the rack, pinion and cover.
If the gate is not engaging a limit switch, any movement following
a start or reset during opening takes place at a slow speed until it
reaches the limit switch.
1. Make sure that the motor and limit switch cables are plugged
into the correct connectors, according to the direction in which
the gate opens.
2. Install the high voltage protection cover on the board E850S and
fasten it in place using the 4 screws that were put aside previously
(41).
3. Make sure that the C850 has been released (§ 5.1).
4. Power up the system.
5. Adjust the integrated limit switches (§ 5.2).
6. Programming the E850S board (§ 5.3)
7. Restore automatic operation (§ 5.1).
8. Carry out the procedure for putting the system into service (§ 6).
5.1 MANUAL OPERATION
! Before performing the release operation, shut off the power supply
to the automation.
During manual operation, gently guide the leaf the whole way. Do not
push it and let it slide freely.
Do not leave the gate with the release engaged: after moving it man-
ually, restore automatic operation.
RELEASE PROCEDURE
1. Turn the lock protection shutter clockwise
2. Insert the release key and rotate it anticlockwise by a quarter of
a turn
3. Turn the release knob clockwise until it stops
RESTORING AUTOMATIC OPERATION
1. Turn the release knob anticlockwise until it stops
2. Turn the release key clockwise until it stops, then remove it
3. Turn the lock protection shutter anticlockwise
4. Manually move the gate until the mechanical system engages.

Kit E850S 15 532181 - Rev.A
46
A
47
48
49
50
3 - CL -
4 -R.CL -
1 -R.OP -
2 -OP -
Translation of the original instructions ENGLISH
5.2 LIMIT SWITCH ADJUSTMENT
C850 must be released.
The deceleration starting points and stop points are set by adjusting
the integrated limit switches. The maximum deceleration space
that can be set is 5 m. The minimum deceleration space depends
on the programmed speed (parameters L. and .L):
7 Minimum deceleration spaces
L0 minimum distance from the stop point: 10 cm
L1 minimum distance from the stop point: 40 cm
L2 minimum distance from the stop point: 70 cm
L3 minimum distance from the stop point: 130 cm
! Failure to comply with the minimum distances indicated in 7 can
jeopardise the integrity and operation of the C850 and be a potential
safety hazard.
Loosen the central screw of the limit switch unit by one turn (46).
OPENING TO THE LEFT
8 Opening to the left
function cam to be adjusted direction of
adjustment
closing cam 3
closing deceleration cam 4
opening deceleration cam 1
opening cam 2
1. Close the gate as far as the required closed position. The closed
position must be at least 10 cm from the external mechanical stop.
2. Using a screwdriver, turn screw number 3 anticlockwise until the
cam engages the micro switch, as shown in 47. When the
micro switch is activated, the LED DL6 (CL) turns off.
3. Open the gate as far as the closing deceleration starting point.
4. Using a screwdriver, turn screw number 4 anticlockwise until the
cam engages the micro switch as shown in 48 When the
micro switch is activated, the LED DL8 (R.CL) turns off.
5. Open the gate as far as the required opening deceleration starting
point.
6. Using a screwdriver, turn screw number 1 clockwise until the cam
engages the micro switch, as shown in 49. When the micro
switch is activated, the LED DL7 (R.OP) turns off.
7. Open the gate as far as the required open position. The open
position must be at least 10 cm from the external mechanical stop.
8. Using a screwdriver, turn screw number 2 clockwise until the cam
engages the micro switch, as shown in 50. When the micro
switch is activated, the LED DL5 (OP) turns off.

Kit E850S 16 532181 - Rev.A
51
52
53
54
55
56
2 -CL -
1 -R.CL -
4 -R.OP -
3 - OP -
Translation of the original instructions ENGLISH
OPENING TO THE RIGHT
9 Opening to the right
function cam to be adjusted direction of
adjustment
closing cam 2
closing deceleration cam 1
opening deceleration cam 4
opening cam 3
1. Close the gate as far as the required closed position. The closed
position must be at least 10 cm from the external mechanical stop.
2. Using a screwdriver, turn screw number 2 clockwise until the cam
engages the micro switch, as shown in 51. When the micro
switch is activated, the LED DL6 (CL) turns off.
3. Open the gate as far as the required closing deceleration starting
point.
4. Using a screwdriver, turn screw number 1 clockwise until the cam
engages the micro switch, as shown in 52 When the micro
switch is activated, the LED DL8 (R.CL) turns off.
5. Open the gate as far as the opening deceleration starting point.
6. Using a screwdriver turn screw number 4 anticlockwise until the
cam engages the micro switch, as shown in 53. When the
micro switch is activated, the LED DL7 (R.OP) turns off.
7. Open the gate as far as the required open position. The open
position must be at least 10 cm from the external mechanical stop.
8. Using a screwdriver turn screw number 3 anticlockwise until the
cam engages the micro switch, as shown in 54. When the
micro switch is activated, the LED DL5 (OP) turns off.
! Tighten the central screw of the limit switch unit by one turn (55).
Replace the cover of the limit switch unit using the screws that were
put aside previously (56).

Kit E850S 17 532181 - Rev.A
Translation of the original instructions ENGLISH
5.3 PROGRAMMING
To access the programming menu, the display must indicate the gate
closed status (00).
To access the programming mode from whichever state the gate is in,
press and release the RESET button: 00 appears on the display.
Press button P1 (ENTER), for approximately 5 seconds, until the first
parameter Aappears.
Press button P2 (UP/DWN) to modify the value of the parameter.
Press button P1 (ENTER) to go to the next parameter.
After 60 seconds of inactivity, the system will automatically exit from
the programming menu saving any changes that were made.
parameter default
AOPEN B input configuration
0partial opening only
1closes only (CLOSE)
0
bFailsafe
0not enabled
1enabled
0
cAutomatic closing
0not enabled
1enabled, pause 5 s
2enabled, pause 10 s
3enabled, pause 15 s
4enabled, pause 20 s
5enabled, pause 25 s
6enabled, pause 30 s
7enabled, pause 40 s
8enabled, pause 80 s
9enabled, pause 120 s
0
dOPEN A operation
0open/stop/close/open...
1open/close/open..."
0
EPartial opening time
03 s
15 s
28 s
310 s
0
HCondominium function
0not enabled (the OPEN A command is operative during
opening)
1enabled (the OPEN command is ignored during opening)
0
L. Maximum opening speed
010 m/min
120 m/min
230 m/min
340 m/min
0
.L Maximum closing speed
010 m/min
120 m/min
230 m/min
340 m/min
0
oImmediate closure after transit across photocells
0notenabled (withautomaticclosing enabled, thegatealways
closes after the pause time)
1enabled (with automatic closing enabled, the gate closes
immediately after transit across the closing photocells)
0
parameter default
PTimer function
0not enabled
1enabled(the OPENAmaintained action control keeps the gate
open until released)
1
UDead-man function
0not enabled
1enabled (requires the OPEN A and CLOSE maintained action
controls to be used)
! In the dead-man mode:
-The control must be activated intentionally and the
gate must be visible
- The OPEN input is disabled.
- If the SAFE input is activated during opening or
closing, it stops the movement immediately.
- If the FSW CL input is activated during closing, it
stops the movement.
- If the FSW OP input is activated during opening, it
stops the movement.
- the speed of the gate must be less than 5 m/min
0
YPre-flashing during closing
0not enabled
11 s
22 s
33 s
44 s
0
The display, other than when in the programming menu, provides
information regarding the status of the automation (§ 7.2).

Kit E850S 18 532181 - Rev.A
57
58
4
Translation of the original instructions ENGLISH
6. PUTTING INTO SERVICE
F Carry out the following operations with the power supply disconnected.
Before installing the board cover and casing you must have:
- completed the start-up procedure
- checked that the C850and the installed devices are working properly.
1. Install the low voltage protection cover on the board E850S and
fasten it in place using the 3 screws that were put aside previously
(57).
2. Install the cover and fasten it using the 4 screws that were put
aside previously (58).
6.1 FINAL CHECKS
1. Make sure that the forces generated by the leaf are within the
limits permitted by the current regulations. Use an impact force
tester in accordance with standards EN 12453 and EN 12445. For
non-EU countries, of there are no specific local regulations, the
force must be less than 150 N.
2. Check that the maximum force required to move the leaf by hand
is less than 260 N.
3. Check that the C850 and the installed devices are working properly.
7. DIAGNOSTICS
7.1 LEDS CHECK
10Status of the LEDs
LED meaning
DL5 OP opening limit switch not engaged engaged
DL6 OP closing limit switch not engaged engaged
DL7 R.OP deceleration during opening not engaged engaged
DL8 R.CL deceleration during closing not engaged engaged
DL9 OPEN OPEN input active not active
DL10 OPEN B OPEN B input active not active
DL11 OPEN A OPEN A input active not active
DL12 SAFE SAFE input not active active
DL13 FSW CL FSW CL input not active active
DL14 FSW OP FSW OP input not active active
DL15 STOP STOP input not active active
Bold indicates the condition of the LEDs with the board powered, the
gate at its halfway position and no connected device active (=on
; =off).
7.2 STATUS OF THE AUTOMATION
The display, other than when in the programming menu, provides
information regarding the status of the automation:
11Status of the automation
display meaning
00 gate closed
02 gate opening/open
04 gate open in pause
06 gate closing
ST the dead-man function is active and the gate has not yet com-
pleted the opening or closing cycle
ER the failsafe function is active and the test has failed on at least
one device (the LAMP output flashes quickly at the same time)
.8.8 dot on the left lit FSW OP input active
.8.8dot on the right lit FSW CL input active


FAAC S.p.A. Soc. Unipersonale
Via Calari, 10 - 40069 Zola Predosa BOLOGNA - ITALY
Tel. +39 051 61724 - Fax +39 051 758518
www.faac.it - www.faacgroup.com
Kit E850S 20 532181 - Rev.A
Table of contents
Other FAAC Control Unit manuals
Popular Control Unit manuals by other brands

Beninca
Beninca ZED-RE operating instructions

Emerson
Emerson SM-I/O 24V Protected user guide

Weathermatic
Weathermatic N-100 Installation instruction guide

Monacor
Monacor VCA-202R manual

ZURN
ZURN AquaSense ZER-SM Series Installation, operation, maintenance and parts manual

Cincoze
Cincoze MXM-A2000 Quick installation guide