390 / 390 24
ENGLISH
Guide for the installer
Page 5
Thank you for choosing our product. FAAC is sure that it will give you
all the performances you are looking for. All our products are the
result of a long experience in the field of the automated systems.
In the middle of the handbook you will find a detachable
brochure with the images for the installation.
These instructions apply to the following model:
390
The external automation with articulated arms automates residen-
tial swing-leaf gates with leaves of up to 3m in length, and is ideal
for applications on large pilasters without the need to provide
niches (sometimes required to observe the installation dimensions
of piston driven devices).
It consists of an irreversible electro-mechanical operator with guard
and an articulated-arm activation system to be fitted to the gate
with the appropriate accessories.
The irreversible system ensures the gate is mechanical locked when
the motor is not operating. No lock need be installed for leaves
up to 2m in length.
A manual release makes it possible to move the gate in the event
of a power-cut or fault.
IMPORTANT NOTES FOR INSTALLER
Before starting the installation of the operator read this manual
completely.
Keep this manual for future reference.
Smooth operation and specifications are obtained only declared
following the directions given in this handbook and with acces-
sories and safety devices FAAC.
The lack of a mechanical clutch device requires to ensure an
adequate level of security automation, the use of a central control
device with an electronically controlled clutch.
The automation was designed and built to control vehicular ac-
cess. Avoid any other use.
The operator can not be used to handle emergency exit routes
or gates installed on emergency (escape routes).
If there is built-in anti motorize from a door to the walkway is requi-
red to add a safety switch on the door, connected on the entry of
STOP, to inhibit the operation of automation with door open.
Everything that is not expressly stated in this manual is not al-
lowed.
1. DESCRIPTION AND TECHNICAL SPECIFICATIONS
With reference to Figure 1
Pos Description
aGuard
bOperator securing base-plate
cRelease wrench
dRelease
eGearmotor
fTransmission shaft
gStraight lever of articulated arm
hCurved lever of articulated arm
iFront coupling
TAB. 1 TECHNICAL SPECIFICATION OF OPERATOR
MODEL 390
Power supply 230V~ 50Hz 24 Vdc
Power absorption 280 W 40 W
Current absorption 1.2 A 2 A
Max torque 250 Nm 200 Nm
Nominal Torque 170 Nm 140 Nm
Starting capacitor 8 µF /
Leaf max length a3 m
Thermal protection for winding 140 °C /
Reduction ratio 1:700
Angular velocity 8 °/sec
Ambient temperature -20 °C +55 °C
Use frequency at 20°C S3 - 30% S3 - 100%
Cycles / hour at 20°C >30 >100
Noise <70 dB(A)
•
•
•
•
•
•
•
•
MODEL 390
Weight of gearmotor 11.5 Kg
Protection class IP 44
Gearmotor overall dimension Vedi Fig. 2
aAn electrolock should be installed in the event of leaves excee-
ding 2 metres, in order to guarantee the leaf blocking.
2. ELECTRICAL EQUIPMENT (standards system)
With reference to Figure 3
Pos. Description Cables
230 Vac 24 Vdc
aOperators 4x1 mm22x1.5mm2
bTX photocells 2x0.5 mm2
cRX photocells 4x0.5 mm2
dKey selector 2x0.5 mm2
eFlashing lamp 2x1.5 mm2
fControl unit 3x1.5 mm2 (power supply)
gMechanical stops —
To lay electrical cables, use adequate rigid and/or flexible
tubes.
Always separate low voltage accessories from those ope-
rating at 230 V~. To avoid any interference, always use
separate sheaths.
For the motor cable to use a sheath suitable for outdoor use,
a hand that is piped in special ducts always external use.
3. INSTALLATION OF AUTOMATION
3.1. PRELIMINARY CHECKS
To ensure safety and an efficient automation, make sure the
following requirements are met:
The gate structure must be suitable for automation. In particular,
make sure it is sufficiently sturdy and rigid, and that its dimensions
are in line with those indicated in the technical specifications.
Make sure that the leaves move properly and uniformly, without
any irregular friction during their entire travel.
Check if hinges are in good condition.
Make sure the travel limit mechanical stops are present. We
advise you to carry out any metalwork jobs before installing the
automation.
3.2. INSTALLATION DIMENSIONS
Establish the installation position of the operator by consulting
Fig. 4-5-6.
INWARD OPENING (Fig. 5)
A (mm) B (mm) C max. (mm) a (°)
60 ÷ 110
110 ÷ 130
730
90
110 ÷ 160 720
160 ÷ 210 710
210 ÷ 260 700
260 ÷ 310 690
310 ÷ 360 670
60 ÷ 110 190 ÷ 210 650
120110 ÷ 160 230 ÷ 250 600
160 ÷ 210 290 ÷ 310 540
210 ÷ 260 310 ÷ 330 510 120
As for 120° openings the curved arm must be fixed to the
hole marked with the letter “X”
OUTWARD OPENING (Fig. 6)
A (mm) B (mm) C max. (mm) a (°)
60 ÷ 110
110 ÷ 130
430
90
110 ÷ 160 380
160 ÷ 210 330
210 ÷ 260 280
260 ÷ 310 240
•
•
•
•