Introduction
The FLIR Exx series cameras are compact and rugged
infrared cameras that can be used in harsh
environments while still providing you with the latest
technology such as a modern touch screen. A FLIR Exx
series camera is the perfect choice when you are
looking for a robust but feature-rich camera at an
affordable price.
Features
Robust and sophisticated: The FLIR Exx series cameras
have a robust and light-weight design and can
withstand a 2 m drop. Large buttons combined with a
modern touch screen and extensive measuring
capabilities, they are the right choice for demanding
inspections in the field.
Best value for money: The FLIR Exx series cameras
combine good performance (up to 320 ×240 pixels),
a user-friendly interface, and a rugged point-and-
shoot design with an affordable price.
FLIR Exx Thermal Imager
Quick Start Guide
Case Contents
• Infrared camera
• Battery
• Battery charger*
• Camera lens cap
• Extra battery*
• FLIR Tools+ (license only)*
• Handstrap
• Hard transport case
• IR lens
• Memory card
• Power supply, incl. multi-plugs
• Printed documentation
• Tripod adapter*
• USB cable
• Video cable
*The inclusion of this item is dependent on model.
View from the right
1. Cover for the right-hand compartment:
• USB-A connector.
• USB mini-B connector.
• Power connector.
2. Save button.
3. Tripod mount. Requires an adapter (extra
accessory).
4. Focus ring.
5. Infrared lens.
View from the left
1. Laser pointer.
2. Lamp for the digital camera.
3. Digital camera.
4. Cover for the left-hand compartment:
• Video out connector (composite video).
• Memory card slot.
LCD and keypad
1. Touch-screen LCD.
2. Navigation pad with center push.
3. Image archive button.
4. Button to operate the laser pointer.
5. On/off button.
Function:
• Push the button to turn on the camera.
• Push and hold the button for less than 5
seconds to put the camera in standby mode.
The camera then automatically turns off after 6
hours.
• Push and hold the button for more than 10
seconds to turn off the camera.
6. Back button.
Screen elements
1. Measurement tools (e.g., spotmeter).
2. Measurement result table.
3. Status icons and notifications.
4. Temperature scale.
5. Lamp toolbar button.
6. Temperature scale toolbar button.
7. Color toolbar button.
8. Measurement toolbar button.
9. Image modes toolbar button.
10. Recording mode toolbar button.
11. Settings toolbar button.
Note To display the menu system, tap the screen or
push the navigation pad.
Latch to open the cover for the battery
compartment. Push to open.
Quick start guide
1. Put a battery into the battery compartment.
2. Charge the battery for 4 hours before starting the
camera for the first time, or until the green battery
condition LED glows continuously.
3. Insert a memory card into the card slot.
4. Push power button to turn on the camera.
5. Aim the camera toward the object of interest.
6. Adjust the focus by rotating the focus ring.
Note It is very important to adjust the focus
correctly. Incorrect focus adjustment affects how
the image modes Thermal MSX, Thermal, and
Picture-in-picture work. It also affects the
temperature measurement.
7. Push the Save button (the trigger) to save an
image.
8. Install FLIR Tools on your computer.
9. Start FLIR Tools.
10. Connect the camera to the computer using the
USB cable.
11. Import the images into FLIR Tools and create a
PDF report.
Navigating the menu system
The figure above shows the two ways to navigate
the menu system in the camera:
• Using the touch screen LCD to navigate the menu
system (left).
• Using the navigation pad to navigate the menu
system (right).
Focusing the Image
• For far focus, rotate the focus ring clockwise (with
the touch-screen LCD facing toward you).
• For near focus, rotate the focus ring counter-
clockwise (with the touch-screen LCD facing
toward you).
Note Do not touch the lens surface when you adjust
the infrared camera focus manually.
Note It is very important to adjust the focus
correctly. Incorrect focus adjustment affects how the
image modes Thermal MSX, Thermal, and Picture-in-
picture work. It also affects the temperature
measurement.
Adjusting an infrared image
An infrared image can be adjusted automatically or
manually. When manual image adjust mode is
active, the status icon is displayed.
• In live mode, select Temperature scale from the
menu system to switch between automatic and
manual image adjust modes.
• In live mode, you can also select manual image
adjust mode by touching the minimum or
maximum temperature scale level on the screen.
There are two different manual image adjust modes.
Select the type of mode under Settings > Device
settings > Set up camera > Level span mode.
• Level / span: This mode allows you to manually
adjust the level and span of the temperature scale.
• Level / max / min: In this mode, you can manually
adjust the temperature scale minimum and
maximum limits, simultaneously or individually.
Manual adjustment in Level / span mode
1. Push the navigation pad to display the menu
system.
2. Use the navigation pad to go to Temperature
scale.
3. Push the navigation pad.
4. Select Manual and push the navigation pad.
5. Push the navigation pad up/down to
increase/decrease the level.
6. Push the navigation pad right/left to
increase/decrease the span.
Manual adjustment in Level / max / min mode
1. Push the navigation pad to display the menu
system.
2. Use the navigation pad to go to Temperature
scale.
3. Push the navigation pad.
4. Select Manual and push the navigation pad.
5. To simultaneously change the temperature scale
minimum and maximum limits, push the
navigation pad up/down.
6. To change the minimum limit or the maximum
limit, do the following:
• Push the navigation pad left/right to select
(highlight) the maximum or minimum
temperature.
• Push the navigation pad up/down to change the
value of the highlighted temperature.
Changing the temperature range
You must change the temperature range according
to the expected temperature of the object you are
inspecting.
1. Push the navigation pad to display the menu
system.
2. Use the navigation pad to go to Settings.
3. Push the navigation pad.
4. Select Device settings and push the navigation
pad.
5. Select Set up camera and push the navigation pad.
6. Select Camera temperature range and push the
navigation pad.
7. Select the appropriate temperature range and
push the navigation pad.
Changing the color palette
You can change the color palette that the camera
uses to display different temperatures. A different
palette can make it easier to analyze an image.
1. Push the navigation pad to display the menu
system.
2. Use the navigation pad to go to Color.
3. Push the navigation pad.
4. Use the navigation pad to select a different color
palette.
5. Push the navigation pad to confirm the choice.
Imaging Modes
1. Push the navigation pad to display the menu
system.
2. Use the navigation pad to go to Image modes.
3. Push the navigation pad.
4. Select one of the following image modes:
• Thermal MSX.
• Thermal
• Picture-in-picture.
• Digital camera.
Note The data for all image modes are saved when
saving an image. Therefore, if you open an image in,
e.g., FLIR Tools or in the image archive you can still
change the image mode.
Measurement Tools
To measure a temperature, you use one or more
measurement tools, e.g., a spotmeter or a box.
1. Push the navigation pad to display the menu
system.
2. Use the navigation pad to go to Measurement.
3. Push the navigation pad. This displays a
measurement toolbar.
4. On the toolbar, select one of the following and
push the navigation pad:
• No measurements: Clears all measurement
tools from the screen.
• Center spot: A centered spotmeter on the
screen.
• Hot spot: A moving spotmeter indicating the
hottest temperature within a box.
• Cold spot: A moving spotmeter indicating the
coldest temperature within a box.
• 3 spots: Three spots vertically centered.
• Hot spot - Spot: The temperature difference
between the hot spotmeter and the spotmeter.
• Hot spot - Temp: The temperature difference
between the hot spotmeter and a set
temperature.
Moving and resizing measurement tools
You can move and resize measurement tools in
various ways.
Note
• This procedure assumes that you have previously
laid out a measurement tool on the screen.
• You can also move and resize the measurement
tool by touching the screen.
1. To select the measurement tool, touch the tool on
the screen. The tool is now displayed with one or
more handles.
Spot measurement tool:
Area measurement tool:
2. Push the navigation pad. This displays a toolbar.
• Select Resize to change the size of the tool.
• Select Move to move the tool.
• Select Center to move the tool to the center of
the screen.
3. Push the navigation pad up/down and left/right to
resize or move the tool.
4. When completed, push the navigation pad and
select Done.
Setting Parameters
You can change a variety of settings in the camera.
You do this in the Settings dialog box.
1. Push the navigation pad to display the menu
system.
2. Use the navigation pad to go to Settings.
3. Push the navigation pad.
4. Select the setting you want to change. By selecting
some settings, additional dialog boxes are
displayed.
5. Use the navigation pad to navigate in menus or
change values.
6. Push to go back.
Measurement parameters
For accurate measurements, you must set the object
parameters. The camera can use these object
parameters.
• Emissivity
• Reflected temperature
• Distance
• Relative humidity
• Atmospheric temperature
• Window compensation

Other manuals for E series

8

Other FLIR Thermal Camera manuals

FLIR SR-Series User manual

FLIR

FLIR SR-Series User manual

FLIR TCX series User manual

FLIR

FLIR TCX series User manual

FLIR T4 Series User manual

FLIR

FLIR T4 Series User manual

FLIR G300 A User manual

FLIR

FLIR G300 A User manual

FLIR GF309 User manual

FLIR

FLIR GF309 User manual

FLIR E-EST Series User manual

FLIR

FLIR E-EST Series User manual

FLIR FLIR H Series User manual

FLIR

FLIR FLIR H Series User manual

FLIR E series User manual

FLIR

FLIR E series User manual

FLIR TG267 User manual

FLIR

FLIR TG267 User manual

FLIR C5 Series User manual

FLIR

FLIR C5 Series User manual

FLIR K1 User manual

FLIR

FLIR K1 User manual

FLIR T420 User manual

FLIR

FLIR T420 User manual

FLIR T10 series User manual

FLIR

FLIR T10 series User manual

FLIR BCAM User manual

FLIR

FLIR BCAM User manual

FLIR T840 User manual

FLIR

FLIR T840 User manual

FLIR A6 Series User manual

FLIR

FLIR A6 Series User manual

FLIR Scout User manual

FLIR

FLIR Scout User manual

FLIR Voyager II User manual

FLIR

FLIR Voyager II User manual

FLIR FUR GF7x Series User manual

FLIR

FLIR FUR GF7x Series User manual

FLIR EST Series User manual

FLIR

FLIR EST Series User manual

FLIR K65 User manual

FLIR

FLIR K65 User manual

FLIR FB-Series O Manual

FLIR

FLIR FB-Series O Manual

FLIR K33 User manual

FLIR

FLIR K33 User manual

FLIR K1 User manual

FLIR

FLIR K1 User manual

Popular Thermal Camera manuals by other brands

ATN Thermal-Eye X-50 Specifications

ATN

ATN Thermal-Eye X-50 Specifications

PCE Health and Fitness PCE-TC 33N user manual

PCE Health and Fitness

PCE Health and Fitness PCE-TC 33N user manual

Fotric 226B user manual

Fotric

Fotric 226B user manual

Panasonic TC0938450-015CE operating instructions

Panasonic

Panasonic TC0938450-015CE operating instructions

Planck VISION SYSTEMS ThermaCheck TC160 user manual

Planck VISION SYSTEMS

Planck VISION SYSTEMS ThermaCheck TC160 user manual

Maxwell 25990 manual

Maxwell

Maxwell 25990 manual

Dräger UCF FireVista Instructions for use

Dräger

Dräger UCF FireVista Instructions for use

Raymarine T303 Installation and operation instructoins

Raymarine

Raymarine T303 Installation and operation instructoins

AGM Global Vision RATTLER TC35-640 user manual

AGM Global Vision

AGM Global Vision RATTLER TC35-640 user manual

INFRARED CAMERAS FMX HT-640 P Series user manual

INFRARED CAMERAS

INFRARED CAMERAS FMX HT-640 P Series user manual

Intercoax IXIT-1612DP user manual

Intercoax

Intercoax IXIT-1612DP user manual

Turtle Tough TT Series user manual

Turtle Tough

Turtle Tough TT Series user manual

Hikmicro THUNDER 2.0 Series user manual

Hikmicro

Hikmicro THUNDER 2.0 Series user manual

IriSys IR16 series user manual

IriSys

IriSys IR16 series user manual

AGM Global Vision RATTLER TC19-256 user manual

AGM Global Vision

AGM Global Vision RATTLER TC19-256 user manual

Intellisystem ThermalTronix TT-L-BFTC Series user manual

Intellisystem

Intellisystem ThermalTronix TT-L-BFTC Series user manual

Sonel KT-320 quick guide

Sonel

Sonel KT-320 quick guide

Chauvin Arnoux C.A 1954 DiaCAm2 user manual

Chauvin Arnoux

Chauvin Arnoux C.A 1954 DiaCAm2 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.