3.2 Mounting the diaphragm
1NOTICE
▶Install a new diaphragm whenever the
central nut is loosened.
Observe the information on the pack-
aging (risk of contamination).
1. Replace the enclosed O-ring if damaged
(e.g. mechanical or chemical stress,
brittleness).
2. Remove the protection cap from the dia-
phragm pin.
3. Take care not to scratch the diaphragm
face when doing so.
2
1. Replace the O-ring using an appropriate
tool.
2. Screw in the new diaphragm by turning
it clockwise, tightening until hand-tight.
3. Move the operator to the open position
by turning the handwheel anticlockwise.
3
1. Press the operator onto the valve body.
NOTICE
▶Pay attention to the position of the fix-
ing grooves in the body and the fixing
lugs on the operator. These must fit to-
gether exactly.
2. Position the central nut by hand and
tighten it clockwise until hand-tight.
Diaphragm replacement – manual valve