GLP Fusion Stick FS20 User manual

Fusion Stick FS20
Quick Start and Safety Manual
Software version 1.0.1.7

GLP® Fusion Stick FS20 Quick Start and Safety Manual – Revision A
This manual covers fixture software version 1.0.1.7
© 2018-2019 German Light Products GmbH. All rights reserved.
The marks ‘GLP’ and ‘German Light Products’ are trademarks registered as the property of German
Light Products GmbH in Germany, in the United States of America and in other countries.
The information contained in this document is subject to change without notice. German Light
Products GmbH and all affiliated companies disclaim liability for any injury, damage, direct or
indirect loss, consequential or economic loss or any other loss occasioned by the use of, inability to
use or reliance on the information contained in this document.
Manufacturer head office:
German Light Products GmbH (GLP), Industriestrasse 2, 76307 Karlsbad, Germany
Tel (Germany): +49 7248 92719 - 0
Service & Support EMEA:
GLP, Industriestrasse 2, 76307 Karlsbad, Germany
Tel. (Germany): +49 7248 9271955
www.glp.de
Service & Support USA:
GLP USA, 1145 Arroyo St., Ste. A, 91340 San Fernando, California
Tel (USA): +1 818 767 8899
www.germanlightproducts.com

Table of Contents
1. Safety.................................................................................................4
Key to symbols..............................................................................4
General safety information.........................................................4
Electrical safety............................................................................5
Fire safety and protection from burns........................................6
Eye safety......................................................................................7
Strobe safety.................................................................................7
Installation safety and protection from personal injury ...........8
2. Avoiding damage to the fixture .....................................................9
General precautions ...................................................................9
Avoiding damage from light sources and heat.......................9
IP rating .......................................................................................10
Avoiding damage from water and humidity..........................10
Avoiding damage from dust and airborne particles.............11
Transportation and storage ......................................................11
3. FS20 overview..................................................................................12
4. Features ...........................................................................................13
Fixture control.............................................................................13
5. Installation........................................................................................14
Permitted mounting options.....................................................14
Securing fixtures with a safety cable .......................................14
Mounting brackets.....................................................................15
Using FS20 Locking Pins..............................................................16
Standing horizontally on a surface...........................................16
Installing on a surface at any angle ........................................17
Installing on a rigging truss or similar structure ........................17
Side-to-side attachment ...........................................................19
Vertical suspension from a rigging structure...........................19
Suspending multiple fixtures vertically .....................................20
Vertical installation standing on a surface..............................21
6. AC mains power.............................................................................23
Included items............................................................................23
Connecting to power................................................................23
Installing power connectors......................................................23
Connecting multiple fixtures to power in a chain..................24
7. Connecting to DMX data..............................................................25
8. Starting and stopping operation...................................................26
9. Service .............................................................................................27
Cleaning .....................................................................................27
Installing a glare shield ..............................................................27
Installing a diffuser......................................................................28
GLP Service and Support ..........................................................28
10. Technical specifications..............................................................29
11. Dimensions ....................................................................................31

www.glp.de
4 Fusion Stick FS20 Quick Start and Safety Manual Rev. A
1. Safety
Key to symbols
The following symbols are used in this Guide:
General safety information
Read this manual carefully before installing, using or servicing the Fusion Stick FS20
lighting fixture.
If you have any doubts or questions about how to use the fixture safely, contact your
GLP® supplier for assistance. Your GLP supplier will be happy to help.
The user documentation for GLP Fusion Stick FS20 lighting fixtures consists of:
• The FS20 Quick Start and Safety Manual, supplied with FS20 fixtures and available for
download from www.glp.de. The Quick Start and Safety Manual contains important
safety information and installation instructions that the installer and user must read.
• The FS20 User Manual, available for download from www.glp.de. The User Manual
explains features and control of FS20 fixtures.
• The FS20 DMX Channel Index, available for download from www.glp.de. The
Channel Index is a separate guide to the DMX control channel layout and DMX
commands available.
All documents are available for download from www.glp.de.
The Fusion Stick FS20 is intended for use by experienced professionals with the
knowledge and skills to set up, operate, and maintain high-powered, remotely
controlled lighting equipment safely and efficiently. These operations require expertise
that may not be provided in this Manual or in the User Manual.
• Respect all warnings and directions given in the fixture’s user documentation and
on the fixture. Read the user documentation and familiarize yourself with the safety
precautions it contains before installing or using the fixture. GLP and affiliated
Warning! Safety hazard.
Risk of severe injury or
death.
Warning! Hazardous voltage.
Risk of lethal or severe
electric shock.
Warning! See user
manual for important
safety information.
Warning! Fire hazard.
Warning! Risk of eye
injury.

German Light Products®
Fusion Stick FS20 Quick Start and Safety Manual Rev. A 5
companies will take no responsibility for damage or injury resulting from disregard for
the information in the user documentation.
• Check the GLP website at www.glp.de and make sure that you have the latest
version of this manual. Check the fixture software version indicated on page 2 of this
manual and then use the fixture’s control panel to check the version installed in the
fixture. If the versions are not the same, this manual may still cover the fixture,
because software updates do not always affect the way you use the fixture.
However, it is possible that this manual does not match the fixture perfectly.
Software release notes can help clarify this question. You can consult software
release notes and download the correct version of this manual on the GLP website if
necessary.
• Make all user documentation – this Quick Start and Safety Manual as well as the
User Manual – available to all installers and operators. Save both documents for
future reference.
• If you have any questions about the safe operation of the fixture, please contact an
authorized GLP distributor (see list of distributors at www.glp.de).
• Use the fixture only as directed in this manual. Observe all markings in this manual
and on the fixture.
• Refer all repairs and any service operation not described in this manual to a
technician authorized by GLP.
• The light source in this fixture must not be changed by the end user.
• Read and follow the user documentation for all additional equipment.
Electrical safety
• Do not allow the fixture to become immersed. Do not expose the fixture to high-
pressure water projections.
• Keep any unused connectors on the fixture sealed with their protective caps at all
times, both when the fixture is in use and when not in use.
• Use only a source of AC mains power that complies with local building and
electrical codes and has both overload and ground fault (earth fault) protection.
• Ensure that the fixture is electrically connected to ground (earth).
• Disconnect the fixture from AC mains power before carrying out any installation or
maintenance work and when the fixture is not in use.
• Disconnect the fixture from power immediately if any seal, cover, cable, connector
or other component is damaged, defective, deformed or showing signs of
overheating. Do not reapply power until the fixture has been repaired and made
safe by a technician authorized by GLP.
• Check that all power distribution equipment, cables and connectors are in perfect
condition, rated for the electrical requirements of all connected devices, suitable
for their application and suitable for the installation environment.

www.glp.de
6 Fusion Stick FS20 Quick Start and Safety Manual Rev. A
• Use only Neutrik PowerCON TRUE1 cable connectors for AC mains power input at
the fixture’s Mains IN connector and for relaying AC mains power from one fixture’s
Mains OUT (Thru) connector to another fixture’s Mains IN connector.
• Use minimum 14 AWG or 1.5 mm2power input and relay cables that are minimum
16 A-rated and temperature-rated to suit the application. In the USA and Canada
the cables must be UL-listed, type SJT or equivalent. In the EU the cables must be
type H05VV-F or equivalent.
• Do not connect devices to power in a chain if the total maximum current draw of all
the devices in the chain when added together will exceed the current rating of any
cable or connector used at any point in the chain. The supplied power input cable
is rated as follows:
- US power cable: 16 A, 14 AWG, UL-listed, E304117, SJT, 4.9 ft.
- EU power cable: 16 A, 1.5 mm², H07RN-F, 1.5 m.
Do not connect more than four (4) Fusion Stick FS20 fixtures to power in a chain at
100-120 V, 60 Hz.
Do not connect more than eight (8) Fusion Stick FS20 fixtures to power in a chain at
200-240 V, 50 Hz.
• The voltage and frequency at the Mains OUT socket are the same as the voltage
and frequency applied to the Mains IN socket. Only connect devices to the Mains
Out socket that accept this voltage and frequency.
• Fusion Stick FS20 fixtures do not have a user-replaceable fuse. If you suspect that a
fuse has blown, disconnect the fixture from power and send it to a technician
authorized by GLP for repair.
Fire safety and protection from burns
• Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C / 104° F.
• The surface of the fixture’s casing can reach up to 80° C / 176° F during operation.
Avoid contact by persons and materials. Do not install the fixture in a location where
there is a risk of accidental contact. Allow the fixture to cool for at least 20 minutes
before handling
• Keep the fixture well away from flammable materials.
• Keep all combustible materials (e.g. fabric, wood, paper) at least 0.2 m / 8 in. away
from the fixture.
• Ensure that there is free and unobstructed airflow around the fixture.
• Do not illuminate surfaces within 0.2 m / 8 in. of the fixture. The light output from the
fixture is powerful enough to cause burns or fire in illuminated objects at very close
range.
• Do not place any optical components other than Fusion Stick FS20 accessories from
GLP onto the front of the fixture.

German Light Products®
Fusion Stick FS20 Quick Start and Safety Manual Rev. A 7
• Do not stick filters, masks or other materials onto the fixture. Do not block the light
output in any way. The front surface becomes hot during operation and can melt or
ignite objects that are in contact with the surface. Ensure that the front surface Is
clean and unobstructed at all times in order to prevent a fire hazard and damage
to the fixture.
• The fixture’s optical components can focus the sun’s rays, creating a risk of fire and
damage. Do not expose the front of the fixture to sunlight or any other intense light
source, even from an angle.
Eye safety
• The FS20 is classified as a Risk Group 3 lighting fixture according to EN 62471. Possibly
hazardous radiation emitted. Do not stare into the light output from the fixture. May
be harmful to the eyes.
• Do not look at the fixture’s light output with optical instruments or any device that
may concentrate the light output.
• Make sure that persons near to or working on the fixture are not looking directly into
the light output when the fixture lights up suddenly. This can happen when power is
applied, when the fixture receives a DMX signal, or when certain control menu items
are selected.
• The warning below is printed on the fixture. If the warning becomes impossible to
read, replace it with a label reproduced from this illustration:
• Provide well-lit conditions to reduce the pupil diameter of anyone working on or
near the fixture.
Strobe safety
• Flashing light, particularly at 5 - 30 Hz, may cause seizures in persons with
photosensitive epilepsy. Do not use strobe effects for extended periods.
• Comply with local regulations on the use of strobe lighting and notify the public in
advance with highly visible warning signs when strobe effects are used.

www.glp.de
8 Fusion Stick FS20 Quick Start and Safety Manual Rev. A
• If a seizure occurs, stop using strobe effects. Seek professional medical help. Note
the time that the seizure starts and finishes. Call emergency medical help urgently if
the seizure lasts more than five minutes, if it is the person’s first seizure, or if the person
is injured. While waiting for help to arrive, protect the affected person from injuring
themselves on hard or sharp objects. If necessary, move the person to a safe place.
Lay them on their side with their head supported to prevent it from hitting the floor.
Loosen any tight clothing around their neck. Do not use force to hold the person or
restrict their movements. Do not put anything in their mouth, including your fingers.
Installation safety and protection from personal injury
• Installation must be performed by qualified personnel only and carried out in
accordance with all locally applicable regulations such as DIN VDE 0711-217.
• The fixture is not portable when installed.
• Ensure that the supporting structure and installation hardware used can hold at least
ten times the weight of the load that they support.
• Fasten the fixture to a structure or surface only as directed in this manual and only
with hardware that is specifically designed and rated for its purpose. Do not use a
safety cable as the primary means of support. Check that installation hardware is in
perfect condition. Fasteners must be steel grade 8.8 strength or better. Rigging
clamps must be half-coupler type that completely encircle the rigging truss chord.
• If the fixture is installed in a location where it may cause injury or damage if it falls,
install as directed in this manual a safety cable or similar secondary attachment that
will hold the fixture if a primary attachment fails. The secondary attachment must be
approved by an official body such as TÜV as a safety attachment for the weight
that it secures, it must comply with EN 60598-2-17 Section 17.6.6, and it must be able
to support a static suspended load that is ten times the weight that it secures.
• If the fixture is installed in a location where it may be exposed to forces such as wind
pressure, vibration or movement, make sure that the installation can withstand these
forces. Monitor weather forecasts constantly. Take down the installation
immediately if there is any risk of weather conditions that could destabilize the
installation.
• Check that all covers and items of rigging hardware are secure before using the
fixture. Do not operate the fixture with missing or damaged covers, shields or any
optical component.
• Restrict access below the work area and work from a stable platform whenever
installing, servicing or moving the fixture.
• If the fixture becomes damaged, stop using it immediately and disconnect it from
power. Do not attempt to use a fixture that is obviously damaged.
• Do not modify the fixture in any way not described in its user documentation.
• Install genuine GLP parts only.

German Light Products®
Fusion Stick FS20 Quick Start and Safety Manual Rev. A 9
2. Avoiding damage to the fixture
Important! Follow the directions in this section carefully, or the fixture may suffer
damage that is not covered by the product warranty.
General precautions
Do not drop the fixture or expose it to mechanical stress.
Protect the onboard OLED display and control panel from shocks, or they may suffer
damage that is not covered by the product warranty.
Do not expose the fixture to heat (from other lighting fixtures for example).
Clean optical components only as directed. Oils, solvents, and other chemicals
commonly used for cleaning can damage the lens coatings and surfaces.
Use only original spare parts. Do not make any structural modifications to the fixture or
you will void the product warranty.
Avoiding damage from light sources and heat
Do not point the front of the fixture towards the sun or other strong light sources. Strong
light can cause internal damage to the fixture, melting components or starting an
internal fire within seconds.
Figure 1. Avoiding damage from light sources
Damage can occur whether the fixture is powered on or off. See Figure 1. Damage
can also occur if the light hits the front of the fixture at an angle: the fixture does not
need to be pointing directly at the sun or other light source.
To avoid problems from strong light sources:
• Do not expose the front of the fixture to sunlight or any other strong light source.
• In outdoor applications during daylight, make sure that the front face of the fixture is
shielded or points away from the sun, even when not in use.
• Do not aim other high-powered beam lights directly at the fixture.
Do not operate the fixture in ambient temperatures above 40° C / 104° F. Allow free
airflow around the fixture.

www.glp.de
10 Fusion Stick FS20 Quick Start and Safety Manual Rev. A
IP rating
FS20 fixtures are IP65-rated:
• IP stands for Ingress (entry into the fixture) Protection.
• The first figure 6in the rating means that fixtures are protected against the entry of
dust and airborne particles.
• The second figure 5 in the rating means that fixtures are protected against the entry
of rain and water projections from all angles. Fixtures are not protected against
immersion in water and they are not protected against high-pressure water jets.
Avoiding damage from water and humidity
• Do not install FS20 fixtures in a location where water can pool around the fixture or
allow FS20 fixtures to become submerged in any other way. Do not aim low- or high-
pressure water jets at fixtures.
• Keep all unused connectors on the fixture sealed with their protective caps, both
when the fixture is being used and when it is not in use.
• In outdoor and high-humidity environments, use IP65-rated power and data
connectors and cable (an IP65 rating means that the item is protected against the
entry of water from rain, projections and low-pressure jets as well as the entry of
dust). When assembling connectors and installing them on cable, follow the
manufacturer’s instructions (see www.neutrik.com) and ensure that an IP65 rating is
maintained for the complete assembly. Use only the following cable connectors:
- IP65-rated 5-pin XLR connectors for data IN and OUT (THRU)
- Neutrik powerCON TRUE1 NAC3FX-W for Power IN
- Neutrik powerCON TRUE1 NAC3MX-W for Power OUT (THRU).
• Apply a dielectric grease (available from electrical suppliers) to connector terminals
and caps to prevent corrosion and/or electrical short circuits.
• Make sure that cables open into dry areas or sealed junction boxes. Moisture can
be drawn along cables by capillary action or pressure variations resulting from
thermal expansion.
• See drawing on right.
Arrange cables so that they
arrive at connectors from
below. Make sure that it is
impossible for water to flow
down cables and
accumulate at connectors.
If necessary, provide extra
cable slack and create ‘drip loops’ before connectors.
• Create loose cable bends only. Do not subject connections to bending forces or
allow connections to bear the weight of long lengths of cable.

German Light Products®
Fusion Stick FS20 Quick Start and Safety Manual Rev. A 11
Avoiding damage from dust and airborne particles
• Carry out regular visual inspections of the fixture to make sure that there is no
accumulation of dirt, especially on the front of the fixture.
• If cleaning is necessary, follow the instructions in ‘Service’ on page 27.
Transportation and storage
• If fixtures have been fastened together with locking pins, remove the pins and
separate the fixtures before transport. Do not transport fixtures that are fastened
together, or shocks during transport will expose fixtures to leverage forces and may
cause damage that is not covered by the product warranty.
• Transport the fixture in its original packaging to protect it from damage caused by
shocks during transportation.
• Store the fixture in a dry location when not in use.

www.glp.de
12 Fusion Stick FS20 Quick Start and Safety Manual Rev. A
3. FS20 overview
Figure 2. FS20 overview
A – End bracket / side-to-side fastening points
B – AC mains power IN (Neutrik powerCON TRUE1)
C – DMX IN (5-pin XLR)
D – Mounting bracket with quarter-turn fasteners
E – Control panel with OLED display
F – DMX OUT/THRU (5-pin XLR)
G – AC mains power OUT/THRU (Neutrik powerCON TRUE1)
H – Pressure equalization valve
I – Mounting point for optional WDMX antenna
DFA
EG
C
B
D
A
IH

German Light Products®
Fusion Stick FS20 Quick Start and Safety Manual Rev. A 13
4. Features
The Fusion Stick FS20 from GLP can be used indoors in permanent and temporary
installations. Its rugged construction and IP65 rating mean that it can also be used
outdoors in temporary installations if precautions are taken to prevent immersion in
water and damage from direct sunlight. Fixtures can be fastened to a level surface or
suspended from a suitable structure as directed in this manual.
Power and data can be daisy-chained and fixtures interlocked for ease of installation.
The FS20 is not suitable for household use, for use in any location where unattended
children have access to it, or for use in locations that may become submerged in
water.
Fixture control
This Quick Start and Installation Manual gives a very basic overview of control options
and functions. See the FS20 User Manual available for download from www.glp.de for
full details of control, pixel layout, etc.

www.glp.de
14 Fusion Stick FS20 Quick Start and Safety Manual Rev. A
5. Installation
Warning! Read ‘Safety’ starting on page 4 for important safety information
that you must understand before you install or operate the fixture. Install
FS20 fixtures only as described in this chapter, or you may create an
installation that is unsafe.
Install the fixture at least 0.2 m / 8 in. away from combustible materials
(wood, textiles, paper, etc.), 0.2 m / 8 in. away from any surface that will be
illuminated, and a safe distance away from any flammable materials
(volatile spirits, etc.).
It is the installer’s responsibility to provide a stable, secure supporting
structure that is suitable for the environment and application and that
meets all applicable codes and legal requirements. Note the requirement
to secure lighting fixtures with safety cables in temporary installations.
Permitted mounting options
An FS20 fixture may be installed in one of the following ways:
Standing horizontally on a horizontal surface using two FS20 Tilt Brackets as a floor
stand.
Standing vertically on a horizontal surface using an FS20 End Adapter Set and an
FS20 Base Plate.
Fastened to a surface at any angle by means of two FS20 Tilt Brackets.
Fastened to a rigging truss or similar structure at any angle by means of two rigging
clamps and two FS20 Clamp Brackets (optional accessories).
Suspended vertically from a rigging truss or similar structure by means of an FS20
End Adapter Set, an FS20 Vertical Suspension Bracket and a rigging clamp
(optional accessories).
Securing fixtures with a safety cable
In temporary installations, if a fixture can cause injury or damage if it falls you must
secure it with a secondary attachment such as a safety cable that will hold it if the
primary means of attachment fails. The safety cable must be approved for the weight
that it secures. In multiple installations, each fixture must have its own safety cable.
Figure 3. Safety cable attachment points

German Light Products®
Fusion Stick FS20 Quick Start and Safety Manual Rev. A 15
To secure an FS20 fixture with a safety cable:
Loop a safety cable around a secure anchoring point such as a truss chord or fixed
structure so that it will catch the fixture if a rigging clamp fails. Take up as much
slack as possible in the safety cable (by looping it more than once around the truss
chord, for example).
See Figure 3. Fasten the safety cable to one of the attachment eyelets (arrowed) in
the brackets on the back of the fixture. Check that the fixture is now secured.
Mounting brackets
A pair of tilt brackets for fastening the fixture to a surface at any angle or placing the
fixture on a horizontal surface is supplied with the FS20. Clamp brackets for fastening
rigging clamps to the fixture are available as optional accessories.
Figure 4. Bracket options
To mount either a pair of Clamp Brackets or a pair of Tilt Brackets on the back of a
fixture:
See Figure 4. Push the quarter-turn fasteners on the brackets into the fastener
mounting holes on the back of the fixture.
Turn both quarter-turn fastener handles on each bracket a full 90° clockwise to lock
the brackets to the fixture.
Clamp
Brackets
Tilt
Brackets

www.glp.de
16 Fusion Stick FS20 Quick Start and Safety Manual Rev. A
Using FS20 Locking Pins
The FS20 system includes Locking Pins that can be pushed into channels in the ends of
fixtures and in installation hardware and then locked into place.
To install a Locking Pin:
See Figure 5. Push button Aand keep it pressed in while you insert the pin into the
channels.
When the pin is fully inserted, release button A. This will lock the retaining ball B in
the ‘out’ position and prevent the pin from sliding or being pulled out of the
channels.
Standing horizontally on a surface
To place an FS20 fixture standing horizontally on a stable, horizontal surface:
Install two FS20 Tilt Brackets on
the fixture as described in
‘Mounting brackets’ on page 15.
Loosen the handwheels on the
brackets, adjust the brackets to
a suitable angle as shown in
Figure 6 and tighten the
handwheels.
Place the fixture on the surface.
Make sure that it is safe and
secure, and that it will not
present a danger of tripping or
falling.
For instructions on installing an FS20
fixture standing vertically on a horizontal surface, see ‘Vertical installation standing on
a surface’ on page 21.
Figure 6. FS20 standing horizontally
AB
Figure 5. Locking Pin

German Light Products®
Fusion Stick FS20 Quick Start and Safety Manual Rev. A 17
Installing on a surface at any angle
To install an FS20 fixture on a surface at any angle:
Check that the surface is secure and can safely hold the weight of the fixture plus
all hardware and cables.
Install two FS20 Tilt
Brackets on the fixture as
described in ‘Mounting
brackets’ on page 15.
See Figure 7. If the
surface is vertical or at
any angle from the
horizontal, install the Tilt
Brackets with the
handwheels (arrowed)
at the top.
Loosen the handwheels on the brackets, adjust the brackets to a suitable angle
and tighten the handwheels.
Hold the fixture in position on the surface and mark the positions of holes for
fasteners on the surface. You will need at least two fasteners per Tilt Bracket. Drill
holes if necessary.
Fasten the Tilt Brackets to the surface by passing at least two suitable fasteners such
as grade 8.8 steel bolts or screws through the holes in each bracket and fastening
them to the surface. Fasteners must be suitable for their purpose and the installation
environment.
In a temporary installation, secure the fixture with a safety cable as described in
‘Securing fixtures with a safety cable’ on page 14 if there is any risk that the fixture
will cause injury or damage if it falls.
Installing on a rigging truss or similar structure
You can suspend an FS20 fixture from a rigging truss or pipe using either the fixture’s Tilt
Brackets or the Clamp Brackets that are available from GLP as optional accessories for
the FS20.
If you are going to install the fixture hanging vertically downwards from a horizontal
rigging truss or pipe, you can fasten it to the truss using G-clamps. If you are going to
install the fixture in any other orientation, you must use half-coupler clamps that
completely surround the truss chord or pipe.
Installing on a truss using Tilt Brackets
To install the FS20 on a rigging truss or pipe using rigging clamps and the Tilt Brackets
supplied with the fixture:
Check that the truss or pipe is secure and can safely hold the weight of fixtures,
hardware and cables.
Fasten two Tilt Brackets to the back of the fixture as described in ‘Mounting
brackets’ on page 15.
Figure 7. Installing on a surface

www.glp.de
18 Fusion Stick FS20 Quick Start and Safety Manual Rev. A
Fasten two rigging clamps that are approved for the weight of the fixture to the Tilt
Brackets using two M12 bolts, grade 8.8 steel or better, that pass through the holes
arrowed in Figure 8.
Hold the fixture up to the truss chord, pass the rigging clamps around the truss
chord, then tighten the clamps to install the fixture securely on the truss.
In temporary installations, secure each fixture with a safety cable as described in
‘Securing fixtures with a safety cable’ on page 14 if there is any risk that the fixture
will cause injury or damage if it falls.
Installing on a truss using Clamp Brackets
To install the FS20 on a rigging truss or pipe using rigging clamps and optional Clamp
Brackets:
Check that the truss or pipe is secure and can safely hold the weight of fixtures,
hardware and cables.
See Figure 9. Bolt two rigging clamps A(G-clamps shown) that are approved for
the weight of the fixture to two Clamp Brackets B.
Fasten the Clamp Brackets Bto the mounting plates on the back of the fixture as
shown in Figure 9, inserting the quarter-turn fasteners and then turning the quarter-
turn fastener handles Ca full 90°clockwise to lock them.
Hold the fixture up to the truss chord, pass the rigging clamps around the truss
chord, then tighten the clamps to install the fixture securely on the truss.
Figure 9. Clamp Brackets and rigging clamps
A
B
C
A
CC
B
C
Figure 8. Holes for bolting rigging clamps to Tilt Brackets

German Light Products®
Fusion Stick FS20 Quick Start and Safety Manual Rev. A 19
In temporary installations, secure each fixture with a safety cable as described in
‘Securing fixtures with a safety cable’ on page 14 if there is any risk that the fixture
will cause injury or damage if it falls.
Side-to-side attachment
See Figure 10. Channels Aat both ends of
FS20 fixtures accept FS20 locking pins B.This
feature lets you align fixtures to each other
quickly and accurately to form an
unbroken line of pixels.
Warning! Do not use the locking
channels and pins to support the
weight of fixtures unless the
fixtures are hanging vertically one above
the other. If fixtures are not hanging
vertically, each individual fixture must be
supported by fastening it securely to a
surface or structure as directed in this
chapter, and the locking pins may be used
for alignment purposes only.
Vertical suspension from a rigging structure
You can install the FS20 hanging vertically downwards from a rigging structure if you
use the FS20 Vertical Suspension Set optional accessory.
To install the FS20 Vertical Suspension Set on
a fixture:
See Figure 11. Place the End Plate Bon
the end of the fixture so that the locking
pin channels in the end plate and the
fixture mesh with each other.
Push the two locking pins Ainto the
channels in the End Plate and the fixture
so that the End Plate and fixture are
locked together. Press the button on
each pin so that you can push the pin
fully into its channel.
When the pin is fully engaged, release
the button and check that the pin is now
locked in place.
Obtain a truss rigging clamp and omega
bracket with quarter-turn fasteners that
are approved for the weight that they
will support. Check that they are in perfect condition.
A
B
Figure 10. End channels and locking
pins
Figure 11. Vertical Suspension
Adapter Set
A
B

www.glp.de
20 Fusion Stick FS20 Quick Start and Safety Manual Rev. A
Bolt the rigging clamp securely to the omega clamp and fasten the omega clamp
to the KNV End Plate A using the clamp’s quarter-turn fasteners. Turn both fasteners
a full 90° to lock them.
As soon as you suspend the fixture from a truss using the rigging clamp, install a
safety cable as described in ‘Securing fixtures with a safety cable’ on page 14 if
there is any risk that the fixture will cause injury or damage if it falls.
Suspending multiple fixtures vertically
Warning! You can use locking pins and channels in fixtures to support weight
only when fixtures are fastened together in a vertical chain – do not use
them to support the weight of a fixture at any other angle than hanging
vertically downwards.
Warning! Do not fasten more than six (6) fixtures to each other in one
suspended vertical chain.
You can suspend up to a maximum of six (6) FS20 fixtures in total in an interconnected
vertical chain to give an unbroken line of pixels. To create a hanging vertical chain:
Suspend the first fixture as described in ‘Vertical suspension from a rigging structure’
on page 19. Check that the installation will be safe and that the rigging clamp and
safety cable are approved for the total weight of all the fixtures in the chain.
See Figure 12. Have two FS20 Locking Pins Aready.
Lift the second fixture up to the first so
that the locking channels Bin the fixtures
mesh with each other.
Push the two locking pins Ainto the
channels Bin both fixtures. Press the
button on each locking pin so that you
can push the pin fully into its channel.
When the pin is fully engaged, release
the button and check that the button is in
the fully out position so that the pin is
locked in place. Check that the pins now
lock the two fixtures together.
If required by locally applicable
regulations, secure the second fixture by
using a safety cable to fasten the safety cable attachment eyelets in the brackets
on the back of the first and second fixtures to each other so that the safety cable
will catch the second fixture if it falls. In some regions (where DGUV-215-313 is
applicable, for example) the use of two independent locking pins means that use
of a safety cable is not required.
Continue fastening fixtures to each other as described above to form a vertical
chain. Do not create a chain that contains more than six (6) fixtures in total.
B
A
Figure 12. Locking pins used for
creating a vertical chain
Table of contents
Other GLP Dj Equipment manuals

GLP
GLP GT-1 User manual

GLP
GLP Junior Scan 3 User manual

GLP
GLP YPOC 575 COLOR User manual

GLP
GLP YPOC 250 Color User manual

GLP
GLP YPOC 575 User manual

GLP
GLP Fusion Par FP7 User manual

GLP
GLP Impression X5 IP Bar 1000 User manual

GLP
GLP KNV Series User manual

GLP
GLP Fusion EXO Beam 10 User manual

GLP
GLP IMPRESSION X4L User manual

GLP
GLP impression FRIO BAR User manual

GLP
GLP ION.SPOT User manual

GLP
GLP impression x4 bar Quick start guide

GLP
GLP YPOC CMY 700 User manual

GLP
GLP inmpression E 350 User manual

GLP
GLP JDC Line 500 User manual

GLP
GLP Impression XL User manual

GLP
GLP Impression E350 User manual

GLP
GLP impression s350 User manual

GLP
GLP Impression Series User manual