Guardall Apollo 15 User manual

2m
1m
2m 3m 8m 15m
1m
2m
0
20m
Corridor-Plan View
2.3m
2m 3m 8m 15m 20m
Corridor-Side View
0
1m
1m 5m 10m
Curtain-Plan View
0
1m
Curtain-Side View
2.3m
1.2m 5m 10m
0
6m
8m
4m
4m
8m
0
2m 3m 5m 9m 12m
Volumetric-Plan View
Volumetric-Side View
2.3m
02m 3m 5m 9m 12m
Volumetric - Isometric View from above
Installation
Instructions
Part No. 320531-0A
Apollo
15
Mounting
- The recommended mounting
height is 2.3 metres. This can
be raised or lowered if
required and the lens adjusted
to give optimum detection.
- Consider the area to be
protected and select the
appropriate lens type.
Volumetric lens supplied.
Although Apollo is designed to
tolerate a wide range of
environments, the normal
professional installation
guidelines should be
followed.
- Avoid the main false alarm
sources.
*Sunlight shining directly onto
the detector.
*Strong air draughts onto the
detector.
- Mount the detector on a stable
surface which is not subject to
vibration.
- Large objects placed in front of
the detector will cause
significant changes in
coverage.
Lens Declination Positions
A - Horizontal Main Beams
(normally used for pet alley with
fill in beams masked)
B - Normal Position
C - Full declination, detection
range about 50% at
recommended mounting height
Checking Detector Operation
- Switch on power and ensure
that the voltage at terminals 1
and 2 is between 8.5 and
16.5 V dc. A flashing LED will
showif the voltage is too low.
Walk Testing
- With the LED link fitted (as
supplied), walk test the area
checking that the LED lights
whenyou are in range,
indicating correct operation.
- Vertical adjustment
(approximately +2˚, -12˚ )
of the coverage pattern is
possible by loosening the lens
clamping screws and moving
the lens up or down until the
correct coverage is obtained.
- In corner mount installations,
horizontal adjustment
(approximately +/-5˚ ) of the
coverage pattern can be
achieved by moving the base
sideways before tightening the
wall screws.
- Normal operation of 15 m
range, at a mounting height of
2.3 m, should have the lens
set to B.
LED Enable Link/Jumper
- This link (when fitted) enables
the walk test LED.
- If the walk test LED is not
required during normal
operation then remove and
park the LED enable link on
one pin.
- If the control panel provides an
LED control line, then this may
be connected to the detectors
LED Test Line for remote
operation.
- The LED can only be control
led remotely if the
LED link is removed and
parked on one pin.
Pulse Count Link
- The detector has been factory
set to pulse count. This is
recommended only for
volumetric applications and not
for curtain or corridor
applications. Pulse count can
be disabled by fitting LK1.
When pulse count is selected,
the LED will flash on every
threshold crossing.
Final Installation Check
- Fit the front cover.
- Walk test the area checking
that alarms are indicated at the
control panel.
- If tamper is wired check
operation of tamper.
NOTE: Guardall recommend that
the detector is regularly walk
tested back to the control panel
and that installers advise their
customers to do this.
Alarm Memory (Apollo Elite
Only)
- Alarm memory means that
should an alarm occur when
the system is Set, then the
LED will not illuminate but the
alarm will be memorised by
the detector. When the
system is subsequently Unset,
the LED will light constantly on
the detector that had alarmed.
Reset occurs the next time the
system is Set.
For correct operation, the
Control Input must be wired
as follows:
Control Line Mode
High Set
Low or Open Circuit Unset
Note: If alarm memory is not
required, then the Control Line
need not be wired. If the LED
Test Line is activated the
detector can be walk tested
normally, without losing its
alarm memory.
20m
15m
20m 10m
10m
15m
All Guardall products are warranted against
defects in workmanship or materials (details
on request). In the interests of improving
quality and design, Guardall reserve the
right to amend specifications without giving
prior notice. Faulty product should be
returned to your supplier.
Guardall Limited,
Lochend Industrial Estate,
Newbridge, Edinburgh
EH28 8PL,
Scotland
Description
Diagram 1
1. Front Cover
2. Front Cover Screw (loosen only - do not remove)
3. Terminal Block (see Diagram 2 for details)
4. Pulse Count Link - LK1
5. LED Enable Link - LK2
6. Tamper Spring
7. LED Display
8. Lens
9. Lens Clamping Screws (2 off - loosen only - do not
remove)
10. Lens Declination Indicator
11. Sneak Lens
12. Cable Knockout Positions
13. Cable Channel
14. Spare Terminal Connection (optional)
15. Cable tie Anchor Point
16. Off-the-Wall Tamper Mounting Points
17. Module Retaining Clip
18. Pet Alley Mask
Diagram 2
12345678
-+
NC
ALARM NC
TAMPER CONT-
ROL
TEST
12V
Apollo Elite only
Diagram 1
Rotate Pet
Alley Mask
and place this
way to mask
all fill-in
beams for
pets, etc.
Place this
way into the
module for
normal
operation (as
supplied)
Specification
Power
Voltage : 8.5 - 16.5 V d c
Current : 8.5 mA maximum at 12 V dc
Maximum Ripple : 2 V peak to peak at 12 V dc
Alarm Output : Normally closed, voltage free relay
contacts. Rated at 24 V, 50 mA dc with
10 Ωseries protection resistor
Alarm Period : Approximately 3 seconds
Tamper Output : Normally closed, voltage free switch
contacts. Rated at 24 V, 50 mA dc
Temperature Range : -10˚C to +55˚C (14˚F to 130˚F)
Coverage Adjustment : +2˚to -12˚vertically, +/-5˚horizontally
when corner mounted
Walk Test LED : Internal link to enable
Pulse Count : Internal link to enable
Remote LED Enable : Remote control of unit LED via LED
Test Line
Control Line
:
Available on Apollo Elite only. Normally
0 V or open circuit, detector supply to
activate. Must have common ground
with detector
Packed Weight : 100 g approximately
Dimensions (HxWxD) : 96 x 63 x 43 mm
Accessories :
W72704 AP12/3
Volumetric Lens
W72705 AP20/3 Corridor Lens
W72706 AP10/3 Curtain Lens
W72321 LPB2 (Low Profile Bracket - providing
+/- 45˚ horizontal/vertical adjustment)
W72977 CMB1 (Ceiling Mount Bracket - providing+/- 45˚
horizontal/vertical adjustment)
▼
A Corner Mounting Screw Holes
B Wall Mounting Screw Holes
C LPB2 / CMB1 Mounting Screw Holes

Other Guardall Security System manuals

Guardall QX User manual

Guardall

Guardall QX User manual

Guardall RX16i User manual

Guardall

Guardall RX16i User manual

Guardall Windsor 500 Owner's manual

Guardall

Guardall Windsor 500 Owner's manual

Guardall Windsor 500 User manual

Guardall

Guardall Windsor 500 User manual

Guardall Windsor 500 Quick start guide

Guardall

Guardall Windsor 500 Quick start guide

Guardall PX18 User manual

Guardall

Guardall PX18 User manual

Guardall px User manual

Guardall

Guardall px User manual

Guardall V12 Pet Friendly User manual

Guardall

Guardall V12 Pet Friendly User manual

Popular Security System manuals by other brands

Roiscok iDo218 manual

Roiscok

Roiscok iDo218 manual

Honeywell Domonial user manual

Honeywell

Honeywell Domonial user manual

DSC PC55O instruction manual

DSC

DSC PC55O instruction manual

HTC Connected Home User's Quick Install Guide

HTC

HTC Connected Home User's Quick Install Guide

Sony SRG-300SE Technical manual

Sony

Sony SRG-300SE Technical manual

First Alert SC9120B user manual

First Alert

First Alert SC9120B user manual

Telefire ADR-3000 System introduction

Telefire

Telefire ADR-3000 System introduction

ADE Accenta G3 Engineering information

ADE

ADE Accenta G3 Engineering information

Sensonic BITE ALARM Operation manual

Sensonic

Sensonic BITE ALARM Operation manual

Besantek BST-MG08 Manual instruction

Besantek

Besantek BST-MG08 Manual instruction

Cumberland PNEG-1640 Installation and operation manual

Cumberland

Cumberland PNEG-1640 Installation and operation manual

ADEMCO Security System VISTA-15 user guide

ADEMCO

ADEMCO Security System VISTA-15 user guide

ATS GM26313-KP1 installation instructions

ATS

ATS GM26313-KP1 installation instructions

ALC SecuFirst ALM314S quick start guide

ALC

ALC SecuFirst ALM314S quick start guide

Mircom Fire-Link NMC-100 Series Installation and operation manual

Mircom

Mircom Fire-Link NMC-100 Series Installation and operation manual

Kingeye ki-g18 user manual

Kingeye

Kingeye ki-g18 user manual

Blonder tongue NXG SYSTEM KIT quick guide

Blonder tongue

Blonder tongue NXG SYSTEM KIT quick guide

Patrol Hawk G11 user manual

Patrol Hawk

Patrol Hawk G11 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.