Content
Chapter 1 Function Overview ....................................................................................1
1.1 Function ............................................................................................................1
1.2 Parameter ......................................................................................................... 1
Chapter 2 Product Introduction ................................................................................ 2
2.1 Product appearance ........................................................................................ 2
2.2 Interface description ....................................................................................... 3
Chapter 3 Installation .................................................................................................4
3.1 Installation Height ............................................................................................4
3.2 Installation Steps ............................................................................................. 5
Chapter 4 Settings ........................................................................................................ 6
4.1 Paring of Mini Outdoor Station and Indoor Monitor .....................................6
4.2 Card Management ............................................................................................7
4.3 Key Synchronization ....................................................................................... 8
4.4 Unlock Time Setting ........................................................................................ 9
4.5 Interaction with Disarming ..............................................................................9
4.6 Door Status Alarm ........................................................................................... 9
4.7 Door Status Warning Tone ............................................................................10
Chapter 5 User Instruction ...................................................................................... 11
5.1 Calling Resident .............................................................................................11
5.2 Call Guard Unit ...............................................................................................11
5.3 Unlock ............................................................................................................. 11

1
Chapter 1 Function Overview
The product is the mini outdoor station of the H Series Digital System VDP. By
using standard CAT5 cables, it makes visual intercom call to indoor monitor and guard
station possible. Besides, it supports IC access control.
1.1 Function
Support IC card
Support calling to indoor monitor and guard unit
Adjustable unlock time
Door status detection
Support normal open/close unlock output
Support online update.
1.2 Parameter
Working Parameter
Working Voltage:DC 24V/PoE 48V
Static Current:≤ 60mA 24V/45mA 48VPoE
Working Current:≤ 130mA DC24V/60mA
48VPOE
Working Temperature:-20℃~+55℃
Storage Temperature:-40℃~70℃
Dimension(W/H/D):168×86×33.5mm
Camera
Type:CMOS
Pixel:2 MP
View Angle:Diagonal 78°
Relative Illumination:48%
Focus Length:2.2mm
Fill-in Light Type: white

2
Chapter 2 Product Introduction
2.1 Product appearance

3
2.2 Interface description
Interface Description①
RJ45 interface: connecting standard 48V POE switch (1236 communication, 4578
power supply)
Interface Description②
+24V GND: independent power supply interface;
NO, COM, NC: normal open/close interface;
GS, GND: door status detection interface;
SW: door unlocking interface.
①
②
+24V GND NO COM NC GS GND SW

4
Chapter 3 Installation
3.1 Installation Height
Suggested Installation Height: camera is 1.6m above the ground

5
3.2 Installation Steps
Step 1: Drilling holes in the wall of installation size (149.5×64.5mm).
Fixing the screw plug on the wall (installation size recommended to refer the center of slot hole),
fix the outdoor station on the wall, and fix it with self-tapping screws (as shown in Figure 2)
Picture 1 Picture 2
Step 2:Writing something on business card and fasten it to the name tag. Connecting wires
according to the wiring diagram (as shown in Picture 3)
Step 3:Install the aluminum alloy panel on the outdoor station, using the screw to secure
according to the position shown(as shown in Picture 4)
Picture 3
Picture 4

6
Chapter 4 Settings
4.1 Paring of Mini Outdoor Station and Indoor Monitor
Within 3 minutes after powering the mini outdoor station, long press the keypad until 3
times short beeps, then short press the keypad with a long beep to enter setting.
Press in indoor monitor project setting (code: 801801), then choose mini
outdoor station 1 or mini outdoor station 2 for setting, which brings to the mini outdoor
station setting page. Follow the instruction and choose device on the right then press
icon , afterwards the mini outdoor station and indoor monitor are paired
successfully.
Configuration interface of mini outdoor station
Note: when connection done, the icon of mini outdoor station will be
highlighted in indoor monitor relevant page.

7
4.2 Card Management
Press in indoor monitor Mini Outdoor Station setting, input the password to
access to setting, choose card management to entering card management interface.
Card Management Interface
Choose the mini outdoor station needs to be set, details of functions of icon below:
Delete all registered card;
Delete a single card;
Register card
Return
After choosing icon , put the IC card to the card reading area of mini outdoor
station. After a short beep, the card will be registered. Return to the indoor monitor page,
you will see the registered card number.
Interface of card reading notice

8
Interface of registered card (with card number)
4.3 Key Synchronization
In the case of multiple extension of indoor monitors in one apartment, if only one indoor
monitor has been paired with the mini outdoor station, then that’s the only indoor
monitor which unlocks the door and owns the admins rights, in which case, only this
indoor monitor shows a highlighted mini outdoor station icon in relevant page while
other indoor monitors not.
If you need to copy this admin. rights and unlock permission to other indoor monitors in
the same apartment, then key synchronization is needed
Operation: enter the mini outdoor station management page of the monitor with admin
rights, choosing key synchronization. Process is shown as below:
Key sync succeeded

9
4.4 Unlock Time Setting
Enter interface of mini outdoor station management to set unlock time, range: 1~30
seconds.
4.5 Interaction with Disarming
Choose disarming interaction function of mini outdoor station. When indoor monitor is
armed successfully, the indoor monitor will disarm automatically if the access card
opened the door successfully.
4.6 Door Status Alarm
When the door is detected opened over 120 seconds by mini outdoor station, the guard
station/unit will receive an alarm alert with information of the apartment. Interface on
guard station page is shown as below:
Alarm interface of door opened too long

10
4.7 Door Status Warning Tone
When door status warning tone is chosen, Check the door status alarm tone. If the time
of opening the door is longer than 120 seconds, the alarm will sound automatically.
Prompt the occupant to close the door.
When door status warning tone is not chosen. If the single-outdoor station detects the
door opening for more than 120 seconds, the alarm tone will not automatically sound,
but the alarm information will be uploaded.

11
Chapter 5 User Instruction
5.1 Calling Resident
By short press the call button of outdoor station, visitor starts to call the indoor monitor,
whose ringtone will echo back. If the button is short pressed again during the call, then
the waiting time will be recounted (each call waits for 30 seconds); if the call button is
long pressed during the call, the call will be diverted to the guard unit/management
center; if there’s no answer in 30 seconds, the call will be ended.
5.2 Call Guard Unit
By long press the call button of outdoor station for over 2 seconds, visitor starts to call
the guard unit/management center, whose ringtone will echo back.
If the button is long pressed again during the call, then the call will be switched to the
apartment indoor monitor, then the waiting time will be recounted (each call waits for 30
seconds); if there’s no answer in 30 seconds, the call will be ended.
5.3 Unlock
1. Access IC card unlock
Swipe the IC card registered to the card reading area in mini outdoor station to open the
door.
2. Indoor monitor unlock
Door can be opened by indoor monitor when it’s communicating with outdoor station or
under surveillance mode.
3. External push button unlock
As there’re interface for integration of external push buttons, when this is connected, a
normal push button can be used to unlock the door.

Other manuals for H Series
10
This manual suits for next models
1
Table of contents
Other GVS Intercom System manuals
Popular Intercom System manuals by other brands

Trilogy
Trilogy Orator installation guide

TMEZON
TMEZON MZ-VDP-HD739W Operation instructions

Panasonic
Panasonic VL-SV74 operating instructions

Arlec
Arlec DC687 Installation and operating instructions

Comelit
Comelit HFX-700B Technical manual

PS Engineering
PS Engineering PMA7000B Series Pilot's guide and operation manual