Chapter 4 User Instruction
4.1 Call Guard Station
By long/short press the call button of outdoor station , visitor starts to call the guard unit
whose ringtone will echo back. If there’s no answer in 30 seconds, the call will be
ended.
4.2 Unlock
1) Access IC card unlock
Swipe the registered IC card to the card reading area on outdoor station to open the
door.
2) Unlock during monitoring
When outdoor station is being monitored by indoor station or guard station, the door can
be opened by pressing the unlock key on indoor station or guard station .
3) External push button unlock
As there are interface for integration of external push buttons, when this is connected, a
normal push button can be used to unlock the door.
4.3 Unlock Time Setting
Default unlock time is 5S, unlock time can be set through ‘GVS Config Tool’. Unlock
time range:1~30 seconds.
4.4 Card Management
The maximum supported quantity of management card is 10,000 pcs. Card registration,
card deletion, card data emptying and card property checking can be managed by PC
software or guard station. Besides, single card or card in-batches can be registered or
exported by PC software.
4.5 Door Status Alarm
When the door is detected opened over 120 seconds by outdoor station, outdoor station
and guard station will ring out the alarm alert with the information of door unlock timeout.
Interface on guard unit page is shown as below :
Note: outdoor station will enter registering mode while PC software is registering
card in-batches. In this case, there will be no response either swiping card or
pressing any call button, and guard unit or indoor monitor will prompt message of
busy.