manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. hager
  6. •
  7. Switch
  8. •
  9. hager HIB4 M Series User manual

hager HIB4 M Series User manual

This manual suits for next models

4

Other hager Switch manuals

hager EE110 User manual

hager

hager EE110 User manual

hager HXA031H User manual

hager

hager HXA031H User manual

hager HIC4 T Series User manual

hager

hager HIC4 T Series User manual

hager WBMSLL User manual

hager

hager WBMSLL User manual

hager EEN003 User manual

hager

hager EEN003 User manual

hager TS 204B User manual

hager

hager TS 204B User manual

hager HIC4 G Series User manual

hager

hager HIC4 G Series User manual

hager SP 802 User manual

hager

hager SP 802 User manual

hager EE 200 User manual

hager

hager EE 200 User manual

hager EMN005 User manual

hager

hager EMN005 User manual

hager HIM302 User manual

hager

hager HIM302 User manual

hager EE701 User manual

hager

hager EE701 User manual

hager EG 103 Installation instructions

hager

hager EG 103 Installation instructions

hager EE701 User manual

hager

hager EE701 User manual

hager EE171 User manual

hager

hager EE171 User manual

hager TS 223 Installation instructions

hager

hager TS 223 Installation instructions

hager SP 801 User manual

hager

hager SP 801 User manual

hager HZI815 User manual

hager

hager HZI815 User manual

hager HIC4 G Series User manual

hager

hager HIC4 G Series User manual

hager TS 244 Operator's manual

hager

hager TS 244 Operator's manual

hager 16AX User manual

hager

hager 16AX User manual

hager HIC4 E Series User manual

hager

hager HIC4 E Series User manual

hager TX 025 User manual

hager

hager TX 025 User manual

hager WXT30 Series User manual

hager

hager WXT30 Series User manual

Popular Switch manuals by other brands

SMC Networks SMC6224M Technical specifications

SMC Networks

SMC Networks SMC6224M Technical specifications

Aeotec ZWA003-S operating manual

Aeotec

Aeotec ZWA003-S operating manual

TRENDnet TK-209i Quick installation guide

TRENDnet

TRENDnet TK-209i Quick installation guide

Planet FGSW-2022VHP user manual

Planet

Planet FGSW-2022VHP user manual

Avocent AutoView 2000  AV2000BC AV2000BC Installer/user guide

Avocent

Avocent AutoView 2000 AV2000BC AV2000BC Installer/user guide

Moxa Technologies PT-7728 Series user manual

Moxa Technologies

Moxa Technologies PT-7728 Series user manual

Intos Electronic inLine 35392I operating instructions

Intos Electronic

Intos Electronic inLine 35392I operating instructions

Cisco Catalyst 3560-X-24T Technical specifications

Cisco

Cisco Catalyst 3560-X-24T Technical specifications

Asante IntraCore IC3648 Specifications

Asante

Asante IntraCore IC3648 Specifications

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Siemens

Siemens SIRIUS 3SE7310-1AE Series Original operating instructions

Edge-Core DCS520 quick start guide

Edge-Core

Edge-Core DCS520 quick start guide

RGBLE S00203 user manual

RGBLE

RGBLE S00203 user manual

Thrustmaster FLIGHT SIMULATOR X quick guide

Thrustmaster

Thrustmaster FLIGHT SIMULATOR X quick guide

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Southwire

Southwire SURGE GUARD 41390 RVC troubleshooting guide

Buhler Nivotemp NT 61 Brief instructions

Buhler

Buhler Nivotemp NT 61 Brief instructions

Kramer VS-41HDCP user manual

Kramer

Kramer VS-41HDCP user manual

Techly IDATA AU-270 user manual

Techly

Techly IDATA AU-270 user manual

Belkin F1U109 user manual

Belkin

Belkin F1U109 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

6LE007719Aa
HIB4xxM
zMotorised changeover switch
125A to 630A
Installation and commissioning
Cabinet /
Back Plate
Installation
Step 1
Connecting the
power section
Step 2
COMMAND /
CONTROL terminal
connections
Step 3
Power SUPPLY
terminal
connections
Step 4
Check
Step 5
Emergency
Manual
Operation
Step 6B
Control by
an external
order (AUTO)
Step 6A
Padlocking
Step 6C
Clip for
storage
of the
emergency
handle
IS 551584A / Printing size: A3/ Recto-verso/ Black/ 90g/m²/ Final size A4
551584A
Notes
6LE007719Aa1
Hager Electro S.A.S., Boulevard d'Europe, B.P. 3, 67215 OBERNAI CEDEX, France - www.hager.com OCOM 140890Hager 07.21 6LE007719Aa4
Preliminary operations
Check the following upon delivery and after removal of
the packaging:
• Packaging and contents are in good condition.
• The product reference corresponds to the order.
• Contents should include:
- 1 x motorised changeover switch
- 1 x emergency handle and xing clip
- 1 x quick start instruction sheet
Accessories
• Bridging bars and connection kits
• Terminal shrouds
• Terminal shield
This quick start is intended for personnel trained in the
installation and commissioning of this product. For further
details refer to the product instruction manual available
on the hager website.
• This product must always be installed and
commissioned by qualied and approved personnel.
• Maintenance and servicing operations should be
performed by trained and authorised personnel.
• Do not handle any control or power cables connected
to the product when voltage may be, or may become
present on the product, directly through the mains or
indirectly through external circuits.
• Always use an appropriate voltage detection device to
conrm the absence of voltage.
• Ensure that no metal objects are allowed to fall in the
cabinet (risk of electrical arcing).
Risk of electrocution, burns or injury to
persons and/or damage to equipment.
Risk of damaging the device: In case the
product is dropped or damaged in any way
it is recommended to replace the complete
product.
• For 125 - 160A (Uimp = 8 kV). Terminations must
respect a minimum of 8 mm clearance from live parts
to parts intended to be earthed and between poles.
• For 200 - 630A (Uimp = 12 kV). Terminations must
respect a minimum of 14 mm clearance from live parts
to parts intended to be earthed and between poles.
Failure to observe good enginering practises as well as
to follow these safety instructions may expose the user
and others to serious injury or death.
12
3013022
312313 314315 316317 63A64A 24 14 04 13
CONTROL OUTPUTS
3. CONTROL/COMMAND terminals
Ensure that the product is in Manual Mode.
M
16,2
16,2
8,6
8,6
X T
FC
U
CA
12,5
7,5
21
W
Fix. 187,5
229,5
a
a
b
b
1. Installation
Use cables with 1,5 to 2,5mm2 section.
Screw M3 - Tightening torque: min.: 0.5Nm - max.: 0.6Nm
Clic !
4. Power supply terminal
Remove the Top cover to access and connect the terminal - Replace the cover before putting in service.
2. Power terminal connections
Use terminal lugs, rigid or exible busbars.
6B. Manual operation
Operate the product by placing the handle in the
desired position.
6A. Automatic operation
Door cut-out for front panel
Orientation
Recommended OK OK NO
50.5
20
138
101
6C. Padlocking mode
(Standard: in position O)
Foreseen for max. 3 padlocks Ø 4-8mm
AUT
1
2
4
3
90°
90°
I II
0
AUT
Ensure that the emergency handle is not inserted
in the product and turn the mode selector to the
AUT position.
LED Green = “Power”: ON
LED Manuel/Default : OFF
order I
order II
position I
order 0
position 0
position II
Impulse ≥ 60 ms
Impulse
maintened
Contactor logicImpulse logic
To enable control, close contact 312 with 317.
To force the product to 0 position/OFF bridge the contact 313 with 317.
For contactor logic bridge contact 316 with 317.
To operate: close the contact corresponding to the desired position.
1
2
3
Dimensions in mm
125A 160A 200A 250A 315A 400A 500A 630A
Minimum Cu cable section at Ith (mm2) 35 50 95 120 185 2 x 95 2 x 120
Minimum Cu busbar section at Ith (mm2) - 2 x 32 x 5 2 x 40 x 5
Maximum Cu cable section (mm2) 50 95 120 150 240 2 x 185 2 x 300
Maximum Cu busbar width (mm) 25 32 50
Type of screw M8 M10 M12
Recommended tightening torque (N.m) 8,3 20 40
Maximum tightening torque (N.m) 13 26 45
125A 160A 200A 250A 315A 400A 500A 630A
4P
F317 378 437
M150 210 270
T36 50 65
C244 321
U20 25 35 32 45
W911 13
CA 10 15 20
X22 33 37,5
5. Check
In manual mode,
check the wiring.
If OK power up
the product.
LED Green = “Power”: ON
LED Red =
“Manuel/Defaut” : ON
6LE007719Aa36LE007719Aa2
Ensure that the product is installed
on a at rigid surface.
1
M8 Type Z M8
2
3
500A, 630A125A to 400A
Mounting
Removing covers
Max.
0.51 in.
13 mm.
6LE007719Aa
HIB4xxM
zMotorised changeover switch
125A to 630A
Installation and commissioning
Cabinet /
Back Plate
Installation
Step 1
Connecting the
power section
Step 2
COMMAND /
CONTROL terminal
connections
Step 3
Power SUPPLY
terminal
connections
Step 4
Check
Step 5
Emergency
Manual
Operation
Step 6B
Control by
an external
order (AUTO)
Step 6A
Padlocking
Step 6C
Clip for
storage
of the
emergency
handle
IS 551584A / Printing size: A3/ Recto-verso/ Black/ 90g/m²/ Final size A4
551584A
Notes
6LE007719Aa1
Hager Electro S.A.S., Boulevard d'Europe, B.P. 3, 67215 OBERNAI CEDEX, France - www.hager.com OCOM 140890Hager 07.21 6LE007719Aa4
Preliminary operations
Check the following upon delivery and after removal of
the packaging:
• Packaging and contents are in good condition.
• The product reference corresponds to the order.
• Contents should include:
- 1 x motorised changeover switch
- 1 x emergency handle and xing clip
- 1 x quick start instruction sheet
Accessories
• Bridging bars and connection kits
• Terminal shrouds
• Terminal shield
This quick start is intended for personnel trained in the
installation and commissioning of this product. For further
details refer to the product instruction manual available
on the hager website.
• This product must always be installed and
commissioned by qualied and approved personnel.
• Maintenance and servicing operations should be
performed by trained and authorised personnel.
• Do not handle any control or power cables connected
to the product when voltage may be, or may become
present on the product, directly through the mains or
indirectly through external circuits.
• Always use an appropriate voltage detection device to
conrm the absence of voltage.
• Ensure that no metal objects are allowed to fall in the
cabinet (risk of electrical arcing).
Risk of electrocution, burns or injury to
persons and/or damage to equipment.
Risk of damaging the device: In case the
product is dropped or damaged in any way
it is recommended to replace the complete
product.
• For 125 - 160A (Uimp = 8 kV). Terminations must
respect a minimum of 8 mm clearance from live parts
to parts intended to be earthed and between poles.
• For 200 - 630A (Uimp = 12 kV). Terminations must
respect a minimum of 14 mm clearance from live parts
to parts intended to be earthed and between poles.
Failure to observe good enginering practises as well as
to follow these safety instructions may expose the user
and others to serious injury or death.