Hameg HM800 User manual

Blank Module
HM800
Manual
English

Subject to change without notice
2
General information regarding the CE marking
General information regarding the
CE marking
HAMEG instruments fulfill the regulations of the
EMC directive. The conformity test made by HA-
MEG is based on the actual generic and product
standards. In cases where different limit values
are applicable, HAMEG applies the strictest
standard. For emission the limits for residential,
commercial and light industry are applied. Re-
garding the immunity (susceptibility) the limits
for industrial environment have been used.
The measuring and data lines of the instrument
have much influence on emission and immunity
and therefore on meeting the acceptance limits.
For different applications the lines and/or cables
used may be different. For measurement opera-
tion the following hints and conditions regarding
emission and immunity should be observed:
1. Data cables
For the connection between instruments resp.
their interfaces and external devices, (computer,
printer etc.) sufficiently screened cables must
be used.
Maximum cable length of data lines must not ex-
ceed 3 m. The manual may specify shorter lengths.
If several interface connectors are provided only
one of them may be used at any time.
Basically interconnections must have a double
screening. For IEEE-bus purposes the double
screened cable HZ72 from HAMEG is suitable.
2. Signal cables
Basically test leads for signal interconnection
between test point and instrument should be
as short as possible. Without instruction in the
manual for a shorter length, signal lines must be
less than 3 meters long.
Signal lines must be screened (coaxial cable - RG58/
U). A proper ground connection is required. In com-
bination with signal generators double screened
cables (RG223/U, RG214/U) must be used.
3. Influence on measuring instruments.
In the presence of strong high frequency electric
or magnetic fields, even with careful setup of the
measuring equipment an influence can not be
excluded.
The HAMEG Instruments GmbH herewith
declares conformity of the product
Product name: Blank Module
Type: HM800
with: HM8001-2
Options: –
with applicable regulations
EMC Directive 89/336/EEC amended by
91/263/EWG, 92/31/EEC
Low-Voltage Equipment Directive 73/23/EEC
amended by 93/68/EEC
Harmonized standards applied
Safety
EN 61010-1:2001 / (IEC 61010-1:2001)
Overvoltage category: II
Degree of pollution: 2
Electromagnetic compatibility
EN 61326-1/A1
Radiation: table 4; Class B
Immunity: table A1
EN 61000-3-2/A14
Harmonic current emissions: Class D
EN 61000-3-3
Voltage fluctuations and flicker
Date: 22.07.2004
Signature
Manuel Roth
Manager
Manufacturer HAMEG Instruments GmbH
Industriestraße 6
D-63533 Mainhausen
DECLARATION OF
CONFORMITY

Subject to change without notice 3
Content
Declaration of conformity 2
General information regarding the
CE marking 2
Blank Module HM800 4
Important hints 5
Safety 5
Operating conditions 5
Warranty and Repair 5
Maintenance 6
Operation of the blank module 6
Interface board for HM800 7
HM8001-2 Interface Specification 8
This will not cause damage or put the instrument
out of operation. Small deviations of the measu-
ring value (reading) exceeding the instrument‘s
specifications may result from such conditions
in some cases.
HAMEG Instruments GmbH

Subject to change without notice
4
HM800
Module for customized instrument construction
Guide rails for mounting circuit boards at 4 different levels
Plastic front panel for easy processing
Power is supplied by the mainframe HM8001-2
Available supply voltages, load capability
see datasheet of HM800
Open blank module
Mainframe HM8001-2
required for operation
Blank Module
HM800
HM800

Subject to change without notice 5
Important hints
Important hints
The operator is requested to read the following
instructions and those of the mainframe HM8001-
2 carefully, to avoid any operating errors and
mistakes and in order to become acquaint with
the module.
After unpacking the blank module, check for any
mechanical damage or loose parts inside. Should
there be any transportation damage, inform the
supplier immediately and do not put the module
into operation. This plug-in module is primarily
intended for use in conjunction with the mainfra-
me HM8001-2. When incorporating it into other
systems, the module should only be operated with
the specified supply voltages.
Safety
This instrument has been designed and tested in
accordance with IEC Publication 1010-1, Safety
requirements for electrical equipment for measu-
rement, control, and laboratory use. It corres-
ponds as well to the CENELEC regulations EN
61010-1. All case and chassis parts are connected
to the safety earth conductor. Corresponding to
Safety Class 1 regulations (three-conductor AC
power cable). Without an isolating transformer,
the instrument's power cable must be plugged
into an approved three-contact electrical outlet,
which meets International Electrotechnical Com-
mission (IEC) safety standards.
Warning!
Any interruption of the protective conductor
inside or outside the instrument or discon-
nection of the protective earth terminal is
likely to render the instrument dangerous.
Intentional interruption is prohibited.
The istrument must be disconnected and secured
against unintentional operation if there is any sug-
gestion that safe operation is not possible.
This may occur:
– if the instrument shows visible damage,
– if the instrument has loose parts.
– if the instrument does not function,
– after long storage under unfavourable circ-
umstances (e.g. outdoors or in moist environ-
ments),
– after excessive transportation stress (e.g. in
poor packaging).
When removing or replacing the metal case, the
instrument must be completely disconnected
from the mains supply. If any measurement or
calibration procedures are necessary on the
opened-up instrument, these must only be carried
out by qualified personnel acquainted with the
danger involved.
Symbols marked on equipment
ATTENTION refer to manual.
DANGER! High voltage.
Protective ground (earth) terminal.
Operating conditions
The ambient temperature range during operation
should be between +5°C and +40 °C and should
not exceed –20 °C or +70 °C during transport or
storage. The operational position is optional, how-
ever, the ventilation holes on the HM8001-2 and on
the plug-in modules must not be obstructed.
Warranty and Repair
HAMEG instruments are subjected to a strict qua-
lity control. Prior to leaving the factory, each ins-
trument is burnt-in for 10 hours. By intermittent
operation during this period almost all defects are
detected. Following the burn-in, each instrument
is tested for function and quality, the specifications
are checked in all operating modes; the test gear
is calibrated to national standards.
The warranty standards applicable are those of
the country in which the instrument was sold.
Reclamations should be directed to the dealer.
Only valid in EU countries
In order to speed reclamations customers in EU
countries may also contact HAMEG directly. Also,
after the warranty expired, the HAMEG service will
be at your disposal for any repairs.

Subject to change without notice
6
Important hints
Return material authorization (RMA):
Prior to returning an instrument to HAMEG ask
for a RMA number either by internet (http://www.
hameg.com) or fax. If you do not have an original
shipping carton, you may obtain one by calling the
HAMEG service dept (+49-6182-800-500) or by
sending an email to service@hameg.com.
Maintenance
The most important characteristics of the instru-
ments should be periodically checked according to
the instructions provided in the sections “Opera-
tional check and alignment procedure“. To obtain
the normal operating temperature, the mainframe
with inserted module should be turned on at least
60 minutes before starting the test. The specified
alignment procedure should be strictly observed.
When removing the case detach mains/line cord
and any other connected cables from case of the
mainframe HM8001-2. Remove both screws on
rear panel and, holding case firmly in place, pull
chassis forward out of case. When later replacing
the case, care should be taken to ensure that
it properly fits under the edges of the front and
rear frames. After removal of the two screws at
the rear of the module, both chassis covers can
be lifted. When reclosing the module, care should
be taken that the guides engage correctly with the
front chassis.
Operation of the blank module
Provided that all hints given in the operating
instructions of the mainframe HM8001-2 were
followed especially for the selection of the cor-
rect mains voltage start of operation consists
practically of inserting the module into the right
or left opening of the mainframe. The following
pre-cautions should be observed:
Before exchanging the module, the mainframe
must be switched off. A small circle (o) is now
revealed on the red power button in the front
centre of the mainframe.
If the BNC sockets at the rear panel of the
HM8001-2 unit were in use before, the BNC cables
should be disconnected from the basic unit for
safety reasons. Slide in the new module until the
end position is reached.
Before being locked in place, the cabinet of the
instrument is not connected to the protective earth
terminal (banana plug above the mainframe mul-
tipoint connector). In this case, no test signal must
be applied to the input terminals of the module.
Generally, the HM8001-2 set must be turned on
and in full operating condition, before applying any
test signal. If a failure of the measuring equipment
is detected, no further measurements should
be performed. Before switching off the unit or
exchanging a module, the instrument must be
disconnected from the test circuit.

Subject to change without notice 7
Interface board for HM800
Interface board for HM800
The interface board HM800 permits the setting of 3 voltages. One of these voltages is fixed to +5V. The
others can be programmed from 5.2V to +20.0V due to the two resistors. *)
The Resistor R402 sets VAvoltage. Resistor R401 sets VBvoltage. The relation between the value of the
resistors and the output voltage is defined by the following formula:
18.8
R401(2) = –––––––––––
V
A(B) – 5.2
Without any resitance, the output voltage amounts 5.2V. The following table shows the resistance values
for some common voltages.
VA (3-4 of CN401) R401
VB (5-6 of CN401) R402
5.2V No resistor
10 V 3.92 k
Ω
12 V 2.80 k
Ω
15 V 1.92 k
Ω
18 V 1.5 k
Ω
20V 1.3 k
Ω
All of the 3 voltages are isolated from each other. One of these voltages can use capacitors between
outputs and ground for EMC (C401 to C406, 100nF X7R 100V). C407 and C408 are used for stability of the
regulation (1nF ceramic capacitors).
Two straps must be soldered as shown in the figure on the next page.
*) For detailed information regarding the connection of the resistors, please refer also to figure''HM8001-2
Interface specification'' on page 8.

Subject to change without notice
8
HM8001-2 Interface Specification
CH 2
CH 1
U 3aU 4 U 3 U 2a U 1U2
9 / 31 Adj.
1
2
3 / 25
5 / 27
6 / 28
7 / 29 +
8 / 30 –
10 / 32
11 / 33
12 / 34
13 / 35
14 / 36 +
15 / 37 –
16 / 38 Adj
17 / 39
18 / 40
19 / 41
20 / 42
21 / 43
22 / 44
5V 4 / 26
BNC (optional)
230 V / 115 V
8V 1 A
5V 1 A
5 ... 20 V / 0.5 A
7 VAC
18 VAC
7 VAC
18 VAC
8 VAC 0,4 A
HM8001-2 Interface Specification
*) RX: for resistance value
refer to table 1
5 ... 20 V / 0.5 A
RX*)
RX*)
*) RX: for the resistance values
please refer to tables on
page 7 and 9

Subject to change without notice 9
HM8001-2 Interface Specification
Connector-Pin Description Voltage at
Bottom Top I min Imax.
BNC
1231
st BNC- resp. 4th BNC-connector (Only PIN1; PIN 23 NC)
2242
nd BNC- resp. 3rd BNC-connector (Only PIN2; PIN 24 NC)
3 25 GND-connection of BNC-connector 1 + 2 (floating)
U1
4 26 +5 V regulated. Reference PIN 5 + 27; 1Amax [Σ(5V, 8V)] 5.0V
5 27 GND (5 V + 8 V) (floating) 0.0V
6 28 +8 V not regulated. Reference PIN 5 + 27; 1 Amax [Σ(5V, 8V)] 14.6V
U2
729
+5...20V regulated. Reference PIN 8 + 30;
PIN 11 + 13 need to be connected. 0.5Amax 16.9V 16.9V *)
8 30 GND +5…20 V (Potential 2)
9 31 Control input; RCi =18.8/(Ua -5.2 V) (RCi = R between PIN 8 + 9) 1.62kΩ *)
U2a
10 32 Between Pin 10 + 11; 18 VAC 0.8 Amax (Potential 2) 20.7V 19.2V
11 33 Between Pin 11 + 12; 7 VAC 0.8 Amax (Potential 2) 7.0V 6.6V
12 34 Between Pin 10 + 12 25VAC 0.8Amax (Potential 2) 27.7V
13 35 Supply of U2 (U2a not used) (connect PIN 11 + 13)
U3
14 36 +5...20V regulated. Reference PIN 15 + 37.
PIN 18 + 20 need to be connected. 0.5Amax 16.6V 16.6V *)
15 37 GND +5…20 V (Potential 3)
16 38 Control input; RCi =18.8/(Ua -5.2 V) (Rs = R between PIN 15 + 16) 1.62 kΩ *)
U3a
17 39 Between Pin 17 + 18; 18 VAC 0.8 Amax (Potential 3) 20.6 V 19.3V
18 40 Between Pin 18 + 19; 7 VAC 0.8 Amax (Potential 3) 7.0V 6.6V
19 41 Between Pin 17 + 19; 25 VAC 0.8 Amax (Potential 3) 27.6 V
20 42 Supply of U3 (U3a not used) (connect PIN 18 + 20)
U4 21 43 8VAC 0.4Amax (floating) 9.3V 8.8V
22 44 8VAC 0.4Amax
HM8001-2 Interface Specification
*) The voltages shown in line 7 and 14 are calculated based on the resistance values choosen in line 9
and 16.
The provided values are taken from a series instrument and are for reference only. The values may
deviate up to 5%.

Subject to change without notice
10
Notes

Subject to change without notice 11
Notes

Subject to change without notice HAMEG Instruments GmbH
44-0800-00E0 (1) 08042009 Industriestraße 6
© HAMEG Instruments GmbH D-63533 Mainhausen
A Rohde & Schwarz Company Tel +49 (0) 61 82 800-0
DQS-Certification: DIN EN ISO 9001:2000 Fax +49 (0) 61 82 800-100
authorized dealer
Oscilloscopes
Spectrum Analyzer
Power Supplies
Modular System
Series 8000
Programmable Instruments
Series 8100
www.hameg.com
*44-0800-00E0*
44-0800-00E0
Table of contents
Other Hameg Power Supply manuals

Hameg
Hameg HM7044 User manual

Hameg
Hameg HM7044 User manual

Hameg
Hameg HMP4030 User manual

Hameg
Hameg HM7042-5 User manual

Hameg
Hameg HM 7042-4 User manual

Hameg
Hameg HM8143 User manual

Hameg
Hameg HMP2030 User manual

Hameg
Hameg HM7044 User manual

Hameg
Hameg HM7042-5 User manual

Hameg
Hameg HM7042-5 User manual

Hameg
Hameg HM7042-3 User manual

Hameg
Hameg HM8143 User manual

Hameg
Hameg HM8040-3 User manual

Hameg
Hameg HMP Series User manual

Hameg
Hameg HM8143G User manual

Hameg
Hameg HM7042-3 User manual

Hameg
Hameg HM7044 User manual

Hameg
Hameg HM7042-5 User manual

Hameg
Hameg HM8040-3 User manual

Hameg
Hameg HM8142 User manual