AARON
TECHNICAL INFORMATION, MARCH 2010
Thank you for purchasing this HiB product. Please read through these instructions carefully and
refer back to them during installation to ensure that your product is fitted safely and that it retains
its high quality finish. Please retain this leaflet for future reference.
This instruction leaflet applies to the following products:
AARON ART NO: 73105900
IMPORTANT INSTALLATION INFORMATION
THIS IS A CLASS I PRODUCT AND MUST BE CONNECTED TO EARTH
INPUT: 220-240V ac 5A IP RATING: IP44
HAZARDOUS VOlTAGES INSIDE - DO NOT OPEN SEALED UNITS
All installations must comply with guidelines which are based on a zonal concept. The colour
coded diagram below illustrates this concept and must be followed to ensure the safe installation
of bathroom lighting. These regulations apply to domestic installations only. Installations must be
made in accordance with the current lEE wiring regulations and relevant building regulations. HiB
recommends that all electrical bathroom products should only be fitted by a suitably qualified,
Part P registered electrician.
BOcm
seem
60cm
60cm
.....
E
E
o
E
~
'"
;?
,..
i
c
,-,
li
:
2'(
Ii·'
li1
l21
6Ocm.,~
E
121
.jl
...
'"
cv
ZONE
1
lONE
2
OUTSIDE
ZONES
Refers 10the area above the bath
or shower up to a height of 2.25
metres and requires a minimum
rating of
IPX4 (splash-proof
Covers an area 0.6 metres
vtide
immediately next to, and all round
zone 1.Wash basins should
also be treated as zone 2. The
minimum rating here is IPX4.
Has no special requirements,
unless water jets are likely 10 be
used for deaning purposes.
FIXING INSTRUCTIONS
1. Position the mirror in a suitable location, ensuring that the domestic electrical mains supply is
within reach of the electrical entry point of the product.
2. Carefully mark the position of the product using a soft pencil.
3. Remove the mirror, and mark the positions of the two mounting points.
mounting point back view
mounting point
\ mounting screw
J
I