HID pivCLASS R10-H User manual

INSTALLATION GUIDE
hidglobal.com An ASSA ABLOY Group brand
GOVERNMENT SOLUTIONS for Physical Access
R10-H, RP10-H, R40-H, RP40-H, RK40-H,
RPK40-H, RKCL40-P, RPKCL40-P, RKCLB40-P
pivCLASS® Reader
Parts
1 - Reader and base plate assembly
1 - Installation guide
2 - Terminal connector - terminal readers only
RKCL40, RPKCL40 & RKCLB40
4 - M3.5 mm x 12 mm Phillips machine screw
4 - #6-32 x .375” Phillips self-tapping machine screw
4 - #6 x 1.5” Phillips sheet metal screw
3 - #6-32 x .4375” Spanner security screw, anti-tamper (black)
3 - #6-32 x .4375 Phillips security screw (black)
1 - Mounting gasket
Recommended
• Cable, 6 conductor, 22 or 24 AWG [65 mm or 51 mm] Twisted Pair, Over-All Shield (Belden 3108A or equivalent) - RS-485-FDX +
power
• Cable, 4 conductor, 22 or 24 AWG [65 mm or 51 mm] Twisted Pair, Over-All Shield and UL approved (Belden 3107A, or equivalent) -
RS-485-HDX + power
• Cable, 6 to 9 conductor, 22 or 24 AWG [65 mm or 51 mm] Over-All Shield, (Alpha 1296C or equivalent) - Wiegand + power
• DC power supply
• Metal or plastic double-gang junction box - RPKCL40 / RPKCL40 / RKCLB40
• Metal or plastic single-gang junction box - R10 / RP10 / R40 / RP40 / RK40 / RPK40
• Reader spacer when using metal junction boxes - see pivCLASS How to Order Guide
• Security tool (for spanner security screw, anti-tamper) HID 04-0001-03
Specifications
pivCLASS Protocol
PRODUCT BASE PART
NUMBER
INPUT VOLTAGE
(VDC)
CURRENT OPERATING
TEMPERATURE CABLE LENGTH UL REF
NUMBER
Standby
AVG1
Maximum
AVG2PEAK3
R10-H 900NHR
12VDC
60mA 100mA
200mA
-30° to 150° F
(-35° to 65° C) RS-485 = 500 ft - 22 AWG
(152 m)
300 ft - 24 AWG
(91 m)
R10Ex1x2x3
RP10-H 900PHR 75mA RP10Ex1x2x3
R40-H 920NHR 65mA 110mA R40Ex1x2x3
RP40-H 920PHR 85mA RP40Ex1x2x3
RK40-H 921NHR 85mA 125mA 220mA RK40Ex1x2x3
RPK40-H 921PHR 95mA RPK40Ex1x2x3
RKCL40-P 923NPR 150mA 185mA 250mA -4° to 122° F
(-20° to 50° C)
RKCL40Ex1x2x3
RPKCL40-P 923PPR RPKCL40Ex1x2x3
RKCLB40-P 924NPR 165mA 215mA 275mA 14° to 122° F
(-10° to 50° C) RKCLB40Ex1x2x3
R10, RP10, R40, RK40, RP40 & RPK40
2 - M3.5 mm x 12 mm Phillips machine screw
3 - #6-32 x .375” Phillips self-tapping machine screw
2 - #6 x 1.5” Phillips sheet metal screw
1 - #6-32 x .375” Spanner security screw, anti-tamper
1 - Mounting gasket (optional, recommended for outdoor
installation)
1 StandbyAVG-RMScurrentdrawwithoutacardintheRFeld.
2MaximumAVG-RMScurrentdrawduringcontinuousPIVcardreads.NotevaluatedbyUL.
3 Peak-highestinstantaneouscurrentdrawduringRFcommunication.
UL Reference Number Deciphering
x1Reader Colors: K = Black
x2 Wiring: N = Pigtail, T = Terminal
x3 Communications: N = No Module, R = RS-485
PLT-01134 A.8

INSTALLATION GUIDE
hidglobal.com An ASSA ABLOY Group brand
© 2012 - 2018 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID GLOBAL, HID, the HID Brick logo, the Chain Design, and PIVCLASS are trademarks or registered
trademarks of HID Global, ASSA ABLOY AB, or its aliate(s) in the U.S. and other countries and may not be used without permission. All other trademarks, service marks, and
product or service names are trademarks or registered trademarks of their respective owners.
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output
are fictitious. Specifications are subject to change without notice.
pivCLASS R10-H, RP10-H, R40-H, RP40-H, RK40-H, RPK40-H, RKCL40-P,
RPKCL40-P, RKCLB40-P
Wiegand and OSDP Protocol
Installation
1 Mounting
Attach Backplate and Mounting Gasket to Junction Box.
Contactless Models Contact Models
1 CommunicationprotocolsotherthanWiegand
orClock&Datarequireanadditionalhardware
modulewhichincreasescurrentby30mA.
PRODUCT BASE PART
NUMBER
INPUT VOLTAGE
(VDC)
CURRENT1
OPERATING
TEMPERATURE CABLE LENGTH5UL REF
NUMBER
Standby
AVG2
Maximum
AVG3PEAK4
R10-H 900N
5-16VDC
12VDC for RS-485
60mA
100mA
200mA
-30° to 150° F
(-35° to 65° C)
Communication Lines
Wiegand = 500 ft - 22 AWG
(152 m)
300 ft - 24 AWG
(91 m)
RS-485 = Max. bus length
4000 ft - 24 AWG
(1,219 m)
Max length between nodes:
1,640 ft - 24 AWG (500m)
R10Ex1x2x3
RP10-H 900P 75mA RP10Ex1x2x3
R40-H 920N 65mA
110mA
R40Ex1x2x3
RP40-H 920P 85mA RP40Ex1x2x3
RK40-H 921N 85mA
125mA 220mA
RK40Ex1x2x3
RPK40-H 921P 95mA RPK40Ex1x2x3
RKCL40-P 923N
12VDC 150mA 185mA 250mA -4° to 122° F
(-20° to 50° C)
RKCL40Ex1x2x3
RPKCL40-P 923P RPKCL40Ex1x2x3
UL Reference Number Deciphering
x1 ReaderColors: K=Black
x2 Wiring: N=Pigtail
T=Terminal
x3 Communications: N=NoModule,
R=RS-485(OSDP)
2 StandbyAVG-RMScurrentdrawwithoutacardintheRFeld.
3 MaximumAVG-RMScurrentdrawduringcontinuousPIVcardreads.
NotevaluatedbyUL.
4 Peak-highestinstantaneouscurrentdrawduringRFcommunication.
5 WiegandCableLengths:100ft(30.5m)22AWG@5-6.4VDC
500ft(152m)22AWG@6.5-16VDC
Junction box not included.
Mounting holes for US single-
gang electrical boxes.
Install gasket for RK40 and
RPK40 models.
Mounting holes for US
double-gang electrical
boxes.
Reverse Configuration Rotating the backplate
180° allows for placing the Contact reader on left
and the Keypad reader on right.
See Section B Reconfigure Reader Assembly for
instructions, before proceeding to Section 2.

INSTALLATION GUIDE
hidglobal.com An ASSA ABLOY Group brand
© 2012 - 2018 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID GLOBAL, HID, the HID Brick logo, the Chain Design, and PIVCLASS are trademarks or registered
trademarks of HID Global, ASSA ABLOY AB, or its aliate(s) in the U.S. and other countries and may not be used without permission. All other trademarks, service marks, and
product or service names are trademarks or registered trademarks of their respective owners.
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output
are fictitious. Specifications are subject to change without notice.
pivCLASS R10-H, RP10-H, R40-H, RP40-H, RK40-H, RPK40-H, RKCL40-P,
RPKCL40-P, RKCLB40-P
2 Wiring
Pigtail Terminal Description Pigtail Terminal Description
Yellow P1-1 Beeper Input Red / Green P2-7 *GPIO1/OSDP (RS485-FDX/HDX-A)
Orange P1-2 LED Input (GRN) Ta n P2-6 *GPIO2/OSDP (RS485-FDX/HDX-B)
Black P1-3 Ground (RTN) Violet P2-5 **Open Collector Output / Tamper
Red P1-4 +VDC White P2-4 ***Wiegand Data 1 / Clock
Drain P1-5 Unused Green P2-3 ***Wiegand Data 0 / Data
Brown P1-6 LED Input (RED) Pink P2-2 *GPIO3 (RS485-FDX-Z)
Blue P1-7 Hold Input Gray P2-1 *GPIO4 (RS485-FDX-Y)
*RS-485applicableforpivCLASSreaders.
**TamperOutput-Whenactivated,outputsynchronizestoground(default).
***Dependentuponreaderconguration.SeetheHTOGforWiegandandClock-in-Datacongurations.
ATTENTION
Observeprecautionsforhandling
ELECTROSTATICSENSITIVEDEVICES
P1
P2
Beeper
GRN LED
GND
+VDC
DRAIN
RED
HOLD
GPIO1
GP102
OC/TMPR
DATA1/CLK
DATA2/DATA
GPIO3
GPIO4
Beeper
GRN LED
GND
+VDC
DRAIN
RED
HOLD
GPIO1
GP102
OC/TMPR
DATA1/CLK
DATA2/DATA
GPIO3
GPIO4
18 in
(0.46 m)
BEEP (YEL)
GRN LED (ORN)
GND (BLK)
+VDC (RED)
DRAIN (BARE)
RED LED (BRN)
HOLD (BLU)
GPIO1(RED/GRN)
GPIO2 (TAN)
OC/TMPR (VIO)
DATA1 (WHT)
DATA2 (GRN)
GPIO3 (PINK)
GPIO4 (GRAY)
Terminal ReaderPigtail Reader
(Terminalblockandmodule
positionvaries)
(Modulepositionvaries)
Notes:
1.PreviousiCLASSreadershadreversedRS-485wiring
(P2-7&P2-6-A&B).WhenupgradingtoapivCLASS
reader,ensureproperconnectionsasdenedbelow.
2.Wiringthereaderincorrectlymaypermanentlydamage
thereader.
3.Forcablelengthsgreaterthan200ft.(61m)orEMF
interference,install120Ω+/-2Ωresistoracross
RS-485terminationends.
4.ItispossibletoreuseexistingWiegandwiringfor
OSDP,however,usingsimplestrandedcable(typicalof
Wiegandaccesscontrolreaders)usuallydoesnotmeet
RS-485twistedpairrecommendations.

INSTALLATION GUIDE
hidglobal.com An ASSA ABLOY Group brand
© 2012 - 2018 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID GLOBAL, HID, the HID Brick logo, the Chain Design, and PIVCLASS are trademarks or registered
trademarks of HID Global, ASSA ABLOY AB, or its aliate(s) in the U.S. and other countries and may not be used without permission. All other trademarks, service marks, and
product or service names are trademarks or registered trademarks of their respective owners.
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output
are fictitious. Specifications are subject to change without notice.
pivCLASS R10-H, RP10-H, R40-H, RP40-H, RK40-H, RPK40-H, RKCL40-P,
RPKCL40-P, RKCLB40-P
3 Attach to Backplate
Contactless Models
Contact Models
Default: Slide Reader Assembly
towards the right to lock.
Attach Reader InstallSecurityScrew
Reversed Configuration: Slide Reader
Assembly to the left to lock.

INSTALLATION GUIDE
hidglobal.com An ASSA ABLOY Group brand
© 2012 - 2018 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID GLOBAL, HID, the HID Brick logo, the Chain Design, and PIVCLASS are trademarks or registered
trademarks of HID Global, ASSA ABLOY AB, or its aliate(s) in the U.S. and other countries and may not be used without permission. All other trademarks, service marks, and
product or service names are trademarks or registered trademarks of their respective owners.
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output
are fictitious. Specifications are subject to change without notice.
pivCLASS R10-H, RP10-H, R40-H, RP40-H, RK40-H, RPK40-H, RKCL40-P,
RPKCL40-P, RKCLB40-P
4 Power & Testing
Contactless Models
Contact Models
Turn on power Test card
Note:
Withakeypadreaderoperatingas26bitemulation,uponpowerupyouhave5secondstoentertheFacilityCodefollowedby#.
Ifunsuccessful,thereaderLEDdisplayssolidRed.Power-cyclethereaderandretryenteringtheFacilityCode.
TheFacilityCodeneedstobemanuallyenteredas3digits(forexample,iftheFacilityCodeis10,enter0-1-0-#).
SEreadersonlyuseFacilityCodesbetween1-255.ThereisnodefaultFacilityCode.
OncetheFacilityCodehasbeenentered,theLEDwilldisplayVioletandthentoanalRed.Thenpower-cyclethereader.
Whenusingakeypad,ifthereare2shortbeepsafterenteringyourPIN,thereaderdoesnothaveaFacilityCodeconguredyet.
Inthisevent,anAdministratorwillneedtopower-cyclethereaderandentertheFacilityCodebeforethereaderwillacceptyourPIN.

INSTALLATION GUIDE
hidglobal.com An ASSA ABLOY Group brand
© 2012 - 2018 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID GLOBAL, HID, the HID Brick logo, the Chain Design, and PIVCLASS are trademarks or registered
trademarks of HID Global, ASSA ABLOY AB, or its aliate(s) in the U.S. and other countries and may not be used without permission. All other trademarks, service marks, and
product or service names are trademarks or registered trademarks of their respective owners.
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output
are fictitious. Specifications are subject to change without notice.
pivCLASS R10-H, RP10-H, R40-H, RP40-H, RK40-H, RPK40-H, RKCL40-P,
RPKCL40-P, RKCLB40-P
A Biometric Reader
Proper Usage
Ensure a good quality Contact:
• Do not press too hard
• Do not move during image acquisition
• Leave your finger on the sensor at least 2 seconds
• Do not slide or roll your finger across the sensor
Cleaning
For optimum performance, it is recommended that the user clean the bio-reader periodically.
The use of a dry cloth is recommended to clean the acquisition surface.
Caution: Acidic liquids, alcohol or abrasive materials are prohibited.
In order not to scratch the surface, remove all dust and residue with gentle movements.
Acquisition Surface

INSTALLATION GUIDE
hidglobal.com An ASSA ABLOY Group brand
© 2012 - 2018 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID GLOBAL, HID, the HID Brick logo, the Chain Design, and PIVCLASS are trademarks or registered
trademarks of HID Global, ASSA ABLOY AB, or its aliate(s) in the U.S. and other countries and may not be used without permission. All other trademarks, service marks, and
product or service names are trademarks or registered trademarks of their respective owners.
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output
are fictitious. Specifications are subject to change without notice.
pivCLASS R10-H, RP10-H, R40-H, RP40-H, RK40-H, RPK40-H, RKCL40-P,
RPKCL40-P, RKCLB40-P
BReconfigure Reader Assembly
The following steps reconfigure the reader assembly to position
the Contact reader component on the left side of the assembly.
1. Disassemble the reader.
• Remove the Keypad reader from the backplate
• Carefully unplug the ribbon cable from the module in the
back of the Keypad reader. Caution: Do not pull on the ribbon
cable as this may damage the connection to the connector.
• Remove the Contact reader from the backplate
• Gently pull the ribbon cable through the backplate
2. Reassemble with the Contact reader on the left side of the assembly.
• Rotate the backplate so that the large cutout for the power cable is on the left
• Gently route the ribbon cable back through the backplate slots, as shown below
• Plug the ribbon cable back into the module (back of Keypad reader) and ensure module is fully
seated into the reader
• Attach the Contact reader to the backplate (this must be installed first, as the Keypad Reader will fit
slightly over the Contact reader)
• Attach the Keypad reader to the backplate (power cable must be threaded through the large
square cutout on the backplate)
• Return to Section 2
Contact reader Keypad reader
Backplate
Ribbon cable
Keypad reader
Contact reader
Backplate
Ribbon cable
Contact reader Keypad reader

hidglobal.com An ASSA ABLOY Group brand
INSTALLATION GUIDE pivCLASS R10-H, RP10-H, R40-H, RP40-H, RK40-H, RPK40-H, RKCL40-P,
RPKCL40-P, RKCLB40-P
CCredential Presentation Best Practices
To ensure a successful read of a PIV card:
1. Hold card between the thumb and index finger.
2. Present the card so that the index finger creates a spacing between the card and the reader face.
Do not place the card flat on the reader.
3. Place the card parallel to the reader form factor. Do not angle to the right or left
4. Place the card parallel to the reader face. Do not angle the card up or down from the reader
face.
UL
Connect only to a Listed Access Control / Burglary power-limited power supply. These readers are intended to be used with listed (UL294) control
equipment.
All models are suitable for outdoor use.
Evaluated for use over Wiegand and RS-485 communications.
Evaluated for use with the M2000 pivCLASS Authentication Module as well as Standard Wiegand and OSDP panels.
FCC CertiFiCation
CAUTION: Any changes or modifications to this device not explicitly approved by manufacturer could void your authority to operate this
equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
HID Global
Americas & Corporate
611 Center Ridge Drive
Austin, TX 78758
USA
Support: 866 607 7339
Fax: 949 732 2120
Asia Pacific
19/F 625 King's Road
North Point, Island East
Hong Kong
Support: 852 3160 9833
Fax: 852 3160 4809
Europe, Middle East & Africa
Phoenix Road
Haverhill, Suolk CB9 7AE
England
Support: 44 (0) 1440 711 822
Fax: 44 (0) 1440 714 840
For additional oces around the world, see www.hidglobal.com corporate oces.
HID Global Customer Support: www.hidglobal.com/customer-service
Equipment
8T29
ACC Control Reader
General Signaling
Equipment
This manual suits for next models
8
Table of contents
Other HID Card Reader manuals

HID
HID Signo 20 User manual

HID
HID iCLASS SE Express R10 User manual

HID
HID MaxiProx 5375A Operating and maintenance instructions

HID
HID iCLASS RK40 User manual

HID
HID OMNIKEY 5121 User manual

HID
HID ProxPro II Reader User manual

HID
HID EdgeReader User manual

HID
HID OMNIKEY 5121 User manual

HID
HID iCLASS R10 User manual

HID
HID ProxPoint Manual

HID
HID MiniProx 5365 User manual

HID
HID Signo 20 User manual

HID
HID MaxiProx DFM Reader - 5375 User manual

HID
HID iCLASS RK40 User manual

HID
HID ProxPro II 5455 User manual

HID
HID iCLASS R90 Manual

HID
HID Miniprox User manual

HID
HID iCLASS RK40 User manual

HID
HID iCLASS SE Biometric Reader User manual

HID
HID iCLASS SE R10F User manual