i
SM7110A961-03
Contents
Introduction................................................ 1
Verifying Package Contents ..................... 2
Measurement Procedure........................... 5
Safety Information..................................... 6
Operating Precautions.............................. 9
1 Overview 17
1.1 Product Overview and
Features .......................................... 17
1.2 Names and Functions of Parts ..... 18
1.3 ScreenCongurationand
Operation ........................................ 23
Measurement screens ................................23
Settings screens .........................................23
1.4 Displayed Contents of
Measurement Screen ..................... 24
1.5 Basic Key Operation ...................... 26
Displaying measurement screen ................26
Displaying the various menu settings
screens .......................................................26
Selecting settings items ..............................27
Methods for changing numerical values .....28
2 Preparing for
Measurement 29
2.1 Connecting Power Cord to
instrument....................................... 29
2.2 Connecting Measurement Leads
to Instrument .................................. 30
2.3 Connecting Electrode .................... 30
2.4 Connecting Humidity Sensor........ 31
2.5 Grounding Instrument ................... 31
2.6 If Measured Object Is to Be
Charged Before Measurement
(Pre-charge) .................................... 33
2.7 For Safe Measurement................... 34
2.8 Outputting Measurement
Current Value Converted to
Analog Signal ................................. 35
2.9 TurningOn/OInstrument ............ 36
2.10 Inspection Before Use ................... 37
3 Basic Measurement 39
3.1 Setting Measured Value Display
Mode................................................ 39
Changing display notation ..........................40
Changing displayed digits...........................40
3.2 Setting Applied Measurement
Voltage ............................................ 41
3.3 Setting Measurement Speed ......... 43
3.4 Changing Current Range............... 44
3.5 Connecting Measurement Leads
or Electrode to Object to Be
Measured ........................................ 45
3.6 Starting/Stopping
Measurement .................................. 46
3.7 ConrmingMeasurement
Results ............................................ 46
Detecting a measurement abnormality .......46
Temperature measurement indication ........46
3.8 Basic Measurement Examples...... 47
4 Applied Measurement 49
4.1 Starting Measurement After
Measured Value Becomes
Stable (Delay Function) ................. 49
4.2 Reducing Variation in Measured
Values (Average Function) ............ 50
4.3 Automatic Inspection (Sequence
Program Function) ......................... 52
4.4 Setting Voltage Value for
Resistance Calculation.................. 56
4.5 Changing Measurement Starting
Conditions (Trigger Function)....... 58
Setting the trigger mode .............................58
Inputting an external trigger ........................59
4.6 Maintaining Measurement
Accuracy
(Self-Calibration Function) ............ 60
4.7 Setting Interlock Function............. 62
How to deactivate the interlock...................63
4.8 Setting Pre-charge ......................... 64
4.9 Limiting Current Flowing
Through Measured Object
(Current Limiter)............................. 65
4.10 Contact Check (Various Setting) .. 67
4.11 Canceling Capacitance of
Measurement Fixture (Fixture
Capacitance Open Correction
Function)......................................... 70
4.12 Contact Check (Executing
Contact Check, Setting
Reference Value) ............................ 71
4.13 Setting Resistivity Calculation
(Resistivity Measurement
Function)......................................... 73
4.14 Further Accelerating
Measurement (Function of
Updating Drawing During
Measurement)................................. 76
4
3
2
1