SiXGB Installation Instructions
The SiXGB is a wireless glassbreak detector intended for use with Honeywell Home controls that support SiX™ Series
devices.
Mounting Guidelines
The SiXGB can be mounted on the
wall or on the ceiling:
•within 7.6 m (25 feet) of the
protected glass
•within clear view of the protected
glass
•at least 2 m (6.5 feet) from the floor
•at least 1 m (3.3 feet) from forced
air ducts
•at least 1 m (3.3 feet) from sirens or
bells greater than 5 cm (2 inches) in
diameter
•between the protected glass and
any heavy window coverings
•when heavy window coverings are
present, the detector can be
mounted on the window frame
•Avoid mounting the detector on the
same wall as the protected glass,
on free-standing posts or pillars, or
in rooms with noisy equipment (air
compressors, bells, power tools,
etc.), if this equipment is operated
when the detector is armed.
To remove the mounting bracket:
Turn the top of the detector 15 degrees counter-
clockwise and separate the mounting bracket.
NOTE: Before mounting the device permanently,
conduct Go/No Go tests (see controller’s
instructions) to verify adequate signal strength and
adjust the device location and orientation as
necessary.
The rear tamper plate MUST be mounted to a stud,
solid wood, or with a robust wall anchor.
2
Enroll
Set the controller in Programming Mode and
when prompted:
1. Remove the battery tab to activate the device
and begin the enrollment process.
2. The Green [G1]1LED flashes during
enrollment (up to about 20 seconds*) The
device sends its unique MAC ID (Serial
Number) and Services information to the
controller.
*NOTE: Enrollment time varies depending on the
signal strength between the device and the
controller.
3. The Green [G1] LED is ON for 3 seconds.
If the sensor is not successfully enrolled during
the enrollment period, the LED turns off and the
device powers down. Activate the tamper, power
down and up again, or use the FG-701
Glassbreak Simulator to restart the enrollment
process.
1Refer to the SiXGB LEDs section.
NOTE: Once enrolled in a system, the detector
cannot be used with another controller until it is
removed from the current controller. See the
Controller’s instructions for details.
Program the SiXGB
Consult the Controller’s instructions for programming
the device in the system.
Adjust the detector sensitivity setting in the controller
programming mode. Refer to the table on the right for
sensitivity options.
Sensitivity Setting Approximate Range
High* 4.6-7.6m / 15-25 ft.
Medium 3-4.6m / 10-15 ft.
Low 1.5-3m / 5-10 ft.
Lowest 0-1.5m / 0-5 ft.
*Factory default. Change the sensitivity setting at
the Controller.
3
SiXGB LEDs
The detector has three LEDs which are visible when
the unit is mounted.
Green 1 [G1] LED indicates device enrollment and
tamper status.
The Red [R] and Green 2 [G2] LEDs provide
information on detector status during Test Mode. The
Green 2LED indicates events and the Red LED
indicates Alarms.
LED Indications Table
G1
Red
G2
Status
1
10 minute Test Mode
Event detected during Test Mode
Alarm detected during Test Mode
2
2
Low Battery detected during Test Mode
Device not enrolled; Enrollment activated
Device enrolled and tamper detected
NOTE: Before using the Test Mode, the detector must first be enrolled in the controller.
1If the SiXGB Test Mode is activated by the FG701, the [G2] LED will flicker, then be off for 3 seconds, then flash once per second.
2
This feature is used for field diagnosis. To save power, the LEDs are not visible during Normal Mode.
Test the SiXGB
The detector should be tested after installation and at least once a
year.
Test Mode can be activated remotely from the Controller (see
Controller’s manual), or on-site with an FG-701 Glassbreak
Simulator, only when the system is disarmed.
Follow directions in the FG-701 Glassbreak Simulator Operating
Instructions to activate and test the SiXGB detector.
Battery Replacement
1. Twist the front cover counterclockwise 15 degrees
and separate it from the mounting bracket.
2. Remove the old battery.
3. Wait 10 seconds.
4. Insert a new battery. Replacement batteries:
Panasonic CR123A Resideo 466
Duracell D123 Duracell D123A
5. Carefully realign the front cover as shown;
reattach and twist the front cover 15 degrees
clockwise to lock it in place.
BATTERY CAUTION: Risk of fire, explosion and burns.
Do not recharge, disassemble, heat above 100° C (212° F) or
incinerate. Dispose of used batteries properly. Keep away from
children.
Specifications
Range:
0’- 25’/ 0 – 7.6m; Selectable
Battery
: 1 x 3V, Lithium; Panasonic CR123A, Duracell DL 123, Duracell DL 123A, Honeywell 466
Tamper
: Cover and Wall
RF Frequency
: 2.4GHz
Operating Temperature
: 0° to 50° C / 32° to 122° F (Agency compliance 0° to 49° C
/ 32° to 120° F)
Relative Humidity
: 95% max. (Agency compliance – 93% max.), non-condensing
Dimensions: 96 mm Diameter x 29mm Thick / 3.78” Diameter x 1.14” Thick
Approval Listings
FCC / IC
cETLus Listed
Conforms to UL 639
Certified to ULC-S306
Other Standards:
RoHS
Protected Glass Types Chart
NOTE: The SiXGB is NOT recommended for protection of glass areas smaller than 27.6 cm x 27.6 cm (10-7/8 inches x 10-7/8 inches).
Glass Type*
Nominal Thickness
Minimum
Maximum
Plate3a
2mm (3/32 in.)
10mm (3/8 in.)
Tempered
3mm (1/8 in.)
10mm (3/8 in.)
Laminated1
4mm (5/32 in.)
14mm (9/16 in.)
Wired
6mm (1/4 in.)
6mm (1/4 in.)
Coated2
3mm (1/8 in.)
6mm (1/4 in.)
Sealed Insulating
3b
3mm (1/8 in.) [13mm (1/2 in.) overall]
6mm (1/4 in.) [19mm (3/4 in.) overall]
* Minimum size for all types is 28cm (11 in.) square; glass must be framed in the wall or mounted in a barrier at least 0.9m (36 in.) wide.
1 Protected only if both plates in the unit are broken
2 Coated glass with security films up to 0.35mm (14 mils) thick (including films for solar protection) may be used. Evaluated with the these products: 3M®SCOTCHSHIELD®
SH14CLARL – 0.35mm (14 mils), 4 ply film; Film Technologies International, Inc.’s GLASS-GARD GGLL 1200 has been evaluated with this product by Underwriters
Laboratories, Inc.
3 In compliance with Underwriters Laboratories of Canada’s Standard for Intrusion Detection Units (CAN/ULC-S306-M89):
a. Plate glass 2.5mm (3/32 in.) to 10mm (3/8-in.) can be used.
b. Seal Insulating glass 4mm (5/32 in.) [15mm (19/32 in.) overall] to 6mm (1/4 in.) [(19mm) 3/4 in. overall] can be used. Sensitivity should be set to High when protection
range is greater than 3.8m (12.5 ft).
FEDERAL COMMUNICATIONS COMMISSION (FCC) & INDUSTRY CANADA (IC) STATEMENTS
The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's
authority to operate the equipment.
CLASS B DIGITAL DEVICE STATEMENT
This equipment has been tested and found to comply with the limits for a Class B digital device, as defined by FCC Rules Part 15.105. The Class B Digital Device statement can be viewed at:
https://customer.resideo.com/en-US/support/residential/codes-and-standards/FCC15105/Pages/default.aspx
FCC / IC STATEMENT
This device complies with Part 15 of the FCC Rules, and Industry Canada’s license-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
Cet appareil est conforme à la partie 15 des règles de la FCC et exempt de licence RSS d’Industrie Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer
d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une réception indésirable.
Responsible Party / Issuer of Supplier’s Declaration of Conformity: Ademco Inc., a subsidiary of Resideo Technologies, Inc., 2 Corporate Center Drive., Melville, NY 11747, Ph: 516-577-2000
RF EXPOSURE
Warning – The antenna(s) used for this device must be installed to provide a separation distance of at least 7.8 inches (20 cm) from all persons and must not be co-located or operating in
conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures.
Mise en Garde
Exposition aux Frequences Radio: L'antenne (s) utilisée pour cet émetteur doit être installée à une distance de séparation d'au moins
7,8 pouces (20 cm) de toutes les personnes.
The product should not be disposed of with other household waste. Check for the nearest authorized collection centers or authorized
recyclers. The correct disposal of end-of-life equipment will help prevent potential negative consequences for the environment and
human health.
Any attempt to reverse-engineer this device by decoding proprietary protocols, de-compiling firmware, or any similar actions is strictly
prohibited.
Support and Warranty
REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED, FOR DETAILS REGARDING LIMITATIONS OF THE ENTIRE
ALARM SYSTEM.
For the latest documentation and online support information, please go to:
www.resideo.com
For the latest warranty information, please go to:
https://www.security.honeywellhome.com/warranty
For patent information, see www.resideo.com
The Honeywell Home Trademark is used under license from
Honeywell International Inc.
All other trademarks are the properties of their respective owners.
All rights reserved.
This product is manufactured by Resideo and its affiliates.
Ê800-21340BÄŠ
800-21340B 11/15 Rev B
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
© 2020 Resideo Technologies, Inc.
www.resideo.com

This manual suits for next models

1

Other Honeywell Home Security Sensor manuals

Honeywell Home PROSiXPANIC User manual

Honeywell Home

Honeywell Home PROSiXPANIC User manual

Honeywell Home PROSiX Series Assembly instructions

Honeywell Home

Honeywell Home PROSiX Series Assembly instructions

Honeywell Home PROSiXFLOOD Assembly instructions

Honeywell Home

Honeywell Home PROSiXFLOOD Assembly instructions

Honeywell Home C7089R1013 User manual

Honeywell Home

Honeywell Home C7089R1013 User manual

Honeywell Home HS3PIR2X User manual

Honeywell Home

Honeywell Home HS3PIR2X User manual

Honeywell Home PROSiXCOMBO Assembly instructions

Honeywell Home

Honeywell Home PROSiXCOMBO Assembly instructions

Honeywell Home VISTA-GSM4G Assembly instructions

Honeywell Home

Honeywell Home VISTA-GSM4G Assembly instructions

Honeywell Home DO8EZS User manual

Honeywell Home

Honeywell Home DO8EZS User manual

Honeywell Home PROSiXMINI Assembly instructions

Honeywell Home

Honeywell Home PROSiXMINI Assembly instructions

Honeywell Home PROSiXCT User manual

Honeywell Home

Honeywell Home PROSiXCT User manual

Honeywell Home PROSiXCOCN Assembly instructions

Honeywell Home

Honeywell Home PROSiXCOCN Assembly instructions

Honeywell Home Resideo PROSIXPIR User manual

Honeywell Home

Honeywell Home Resideo PROSIXPIR User manual

Honeywell Home 5821 User manual

Honeywell Home

Honeywell Home 5821 User manual

Honeywell Home 5800PIR-RES Assembly instructions

Honeywell Home

Honeywell Home 5800PIR-RES Assembly instructions

Honeywell Home SIXCOMBO-CN User manual

Honeywell Home

Honeywell Home SIXCOMBO-CN User manual

Honeywell Home PROSiXSMOKEV User manual

Honeywell Home

Honeywell Home PROSiXSMOKEV User manual

Honeywell Home PROSiXCOMBOC User manual

Honeywell Home

Honeywell Home PROSiXCOMBOC User manual

Honeywell Home FlexGuard 5853 Operating instructions

Honeywell Home

Honeywell Home FlexGuard 5853 Operating instructions

Honeywell Home HS3PIR1X User manual

Honeywell Home

Honeywell Home HS3PIR1X User manual

Honeywell Home CHW3610W User manual

Honeywell Home

Honeywell Home CHW3610W User manual

Honeywell Home 5819S Assembly instructions

Honeywell Home

Honeywell Home 5819S Assembly instructions

Popular Security Sensor manuals by other brands

Texecom Capture A20 manual

Texecom

Texecom Capture A20 manual

Thytronic SME2-IS manual

Thytronic

Thytronic SME2-IS manual

Latchways R20 Usage Guide

Latchways

Latchways R20 Usage Guide

Theben 2080026 manual

Theben

Theben 2080026 manual

STEINEL IR Quattro SLIM Series manual

STEINEL

STEINEL IR Quattro SLIM Series manual

Depot BST-HVD21 Operator's manual

Depot

Depot BST-HVD21 Operator's manual

CMITECH EF-45N user manual

CMITECH

CMITECH EF-45N user manual

Genesis LGWP-15HC Installation handbook

Genesis

Genesis LGWP-15HC Installation handbook

Sensit HXG-2d instruction manual

Sensit

Sensit HXG-2d instruction manual

Zennio Presentia C v2 manual

Zennio

Zennio Presentia C v2 manual

Delta JA-150M user manual

Delta

Delta JA-150M user manual

InPOWER DCS30 Series owner's manual

InPOWER

InPOWER DCS30 Series owner's manual

Inficon Sentrac Strix Edition operating instructions

Inficon

Inficon Sentrac Strix Edition operating instructions

Petzl RIG manual

Petzl

Petzl RIG manual

LI-COR LI-210R instruction manual

LI-COR

LI-COR LI-210R instruction manual

PCB Piezotronics W109C12/038CY010AC Installation and operating manual

PCB Piezotronics

PCB Piezotronics W109C12/038CY010AC Installation and operating manual

Ferport NoTouch 2 Operating and installation instructions

Ferport

Ferport NoTouch 2 Operating and installation instructions

TrafFix SLED manual

TrafFix

TrafFix SLED manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.