Hored IS108GPS-4F User manual

User Manual
IS108GPS-4F
12-port Gigabit managed PoE switch

1
Installation ManualIntroduction
<User Manual> mainly introduces the hardware features,
installation methods, and precautions during the installation of
IS108GPS-4F.
This manual includes the following sections:
Chapter 1: Product introduction. Briefly describe the basic functions
and features of the switch, detailed hardware and software
specificationsand appearance information.
Chapter 2: Hardware Connections. Guide the connection of switch
with other devicesand precautions.
Chapter 3: Product Installation. Guide the hardware installation
method and precautions.
Chapter 4: Product Packaging and Use Recommendations.

2
Chapter 1 Product Introduction
1.1 Product introduction
The IS108GPS-4F is a Gigabit-managed industrial PoE switch
that provides 8 Gigabit PoE ports and 4 Gigabit SFP ports. Each PoE
port can provide up to 46W for IEEE802.3af /at compatible
powered devices (PDs). It is especially suitable for applications
where AC power is not easily available or high wiring costs. With
EMC industrial grade 4 protection; corrugated high-strength
aluminum profile housing, IP40 grade, low power design, seismic
rail mounting, -40°C-75° C operating temperature, it can work in
harsh environments; IS108GPS-4F also supports Apollo cloud
one-stop management platform for status checking and
management monitoring,to make it become a reliable solution for
Intelligent transportation, video surveillance and other harsh
industrial environments.

3
1.2 Features
Full Gigabit Ethernet port
8 full Gigabit RJ45 PoE network port, and 4 Gigabit SFP ports,
breaking the traditional 100M limitation, data transmission will not
stuck
Broadcom high performance industrial grade chip for more
stable performance
Broadcom high-performance industrial-grade chips that
dramatically increase network data processing rates
Powerful working environment
EMC industrial grade 4 protection; corrugated high-strength
aluminum profile housing, IP40 grade, low power design, seismic
rail mounting, -40 ° C-75 ° C operating temperature, can work in
harsh environments
Support Apollo cloud platform one-stop management
Support cloud platform to visualize management of switches and

4
attached power devices, making operation and maintenance
management easier
1.3 Software and hardware specifications
Hardware specification
Chip
Broadcom high performance chip
Flash
16MB
RAM
64MB DDR
Port
8 10/100/1000M RJ45 port
4 1000M SFP port
PoE Power
supply
810/100/1000Mbps RJ45 port support
802.3af/atPoE power supply
The maximum power supply of the whole
machine is240W
The maximum power per port is 46W
Indicator
12Link/Act indicator
8POEindicator
ALMAlarm indicator
P1、P2Power Indicator 1SYSindicator
Performance
Forward mode: store and forward
Backplane bandwidth: 24Gbps
Packet forwarding rate: 17.8Mpps
Support 8K MAC address table depth

5
Standard
protocol
IEEE 802.3: Ethernet Media Access Control (MAC)
Protocol
IEEE 802.3i: 10BASE-T Ethernet
IEEE 802.3u: 100BASE-TX Fast Ethernet
IEEE 802.3ab: 1000BASE-T Gigabit Ethernet
IEEE 802.3z: 1000BASE-X Gigabit Ethernet
(optical fiber)
IEEE 802.3ad: Standard method for performing
link aggregation
IEEE 802.3x: Flow Control
IEEE 802.1p: LAN Layer 2 Qos/Cos protocol for
traffic prioritization (multicast filtering)
IEEE 802.1q: VLAN Bridge Operation
IEEE 802.1d: STP spanning tree
IEEE 802.1s: MSTP Spanning Tree
IEEE 802.1w: RSTP Spanning Tree
IEEE 802.3af
IEEE 802.3at
Industry
Standard
EMI:FCC CFR47 Part 15, EN55022/CISPR22, Class
A
EMS:
IEC61000-4-2 (ESD): ±8kV (contact), ±15kV (air)
IEC61000-4-3 (RS): 10V/m (80MHz-2GHz)
IEC61000-4-4 (EFT): Power Port: ±4kV; Data Port:

6
±2kV
IEC61000-4-5 (Surge): Power Port: ±2kV/DM,
±4kV/CM; Data Port: ±6kV
IEC61000-4-6 (CS): 3V (10kHz-150kHz); 10V
(150kHz-80MHz)
IEC60068-2-6 (Vibration)
IEC60068-2-27 (Shock)
IEC60068-2-32 (Free Fall)
Operation
environment
Working temperature: -40 ~ 75 ° C
Storage temperature: -40 to 75 ° C
Relative humidity: 5% to 95% (no condensation)
Certification
CE, FCC, RoHS
Mean time
between
failures(MTBF)
100,000 hrs
Warranty
3 years
Lightning
protection
Network port: ±6KV power port: ±4KV
ESD
Contact: ±8KV Air: ±15KV
Physical
specification
Input:48-56VDC
Housing: IP40 grade protection, corrugated high
strength metal housing
Installation: DIN rail mounting
Size: 163mm × 46.5mm × 110mm, weight: 1kg

7
Software specification
Global
control
button
AI PoE
AI Loop Protect
AI VLAN
AI Extend
Hardware
watchdog
Support
Traffic
Statistics
Support
Port energy
saving
Support
DHCP
Support DHCP Snooping
VLAN
Support 4KVLANs
Support 802.1Q VLAN、MAC VLAN ,IP VLAN
Voice VLAN
MACaddress
Follow the IEEE 802.1d standard
Support MAC address automatic learning and
aging
Support static, dynamic, filtering address table
Safety
features
Password protection
Support restrict user access based on port
number, IP address, and MAC address
Support HTTPS、SSL V3、TLS V1、SSH V1/V2

8
SupportIP-MAC-PORT ternary binding
Support ARP protection, IP source protection,
DoS protection
Support DHCP Snooping and DHCP attack
protection
Support 802.1X authentication, AAA
Support port security, port isolation
Support CPU protection
POE
management
Support PoE power limit
Support viewing of PoE chip status
Support to set PoE port priority
Support to set PoE power supply time period
QoS
Support 8 port queues
Support port priority, 802.1P priority, DSCP
priority
Supports SP, WRR, and RR priority scheduling
algorithms
Supports automatic identification,
managementand retrieval of information about
attached devices
Spanning tree
Supports STP (IEEE 802.1d), RSTP (IEEE 802.1w)
and MSTP (IEEE 802.1s) protocols
Support loop protection, root bridge
protection, TC protection, BPDU protection,

9
BPDU filtering
Multicast
Suppor IGMP v1/v2 Snooping
Support fast leave mechanism
Support multicast VLAN
Supports multicast filtering, packet statistics,
and unknown multicast discards.
Storm
suppression
Support multicast suppression
Support broadcast suppression
Support unknown unicast suppression
Link
aggregation
Support static aggregation
Support dynamic aggregation
Support IP, MAC, hybrid load balancing mode
Supports up to 32 aggregation groups
IPv6
SupportIPv6 Ping、IPv6 Tracert、IPv6 Telnet
SupportIPv6 SSH 、IPv6 SSL
Management
and
maintenance
Support WEB network management (HTTP,
HTTPS, SSL V3)
Support CLI (Telnet, SSH V1/V2, local serial port)
SupportSNMP V1/V2/V3,
SupportLLDP、RMON
Support ARP protection, IP source protection,
DoS protection
Support SNMP protocol

10
1.4 Appearance
Support Apollo cloud platform one-stop
management and maintenance
Support CPU monitoring, memory monitoring
Support system log, grading warning
Support Ping, Tracert detection, cable detection

11
Indicator
Status
Description
P1、P2
On
Thecorrespondingpower supply
working normally.
Off
The correspondingpower supply is
not connected or working
abnormal.
SYS
Blinking
System is running normally
Off / always
bright
System operation is abnormal /
start unsuccessful
ALM
On
Alarm start up
Off
Alarm not triggered
Link/ACT
F1-F4
Blinking
SFP port is working normal
Off
SFP port is working abnormally /
port is not connected
Chapter 2. Hardware Connection
2.1 Connect to RJ45 port
Use the network cable to connect the switch to the RJ45 port
of network device. Normally, the switch's downlink port has POE
power supply enabled by default. It can support POE power supply
to AP, bridge, network camera and other PDs which comply with

12
IEEE802.3af and IEEE802.3at standards.
2.2 Connect to the SFP port
The SFP port of the IS108GPS-4F supports only Gigabit fiber
modules. It is recommended to use standard SFP module products.
The process of installing a fiber module on a switch is as follows:
1. Grasp the fiber module from the side and insert it smoothly
along the SFP port slot of the switch until the fiber module is in
close contact with the switch;
2. Confirm the Rx and Tx ports of the fiber module when

13
connecting. Insert one end of the fiber into the Rx and Tx ports to
ensure that the Tx and Rx ends of the interface are correctly
connected, and the other end of the fiber is connected to another
device.
3. After power-on, check the status of the corresponding
indicator. If the indicator is on, the link is up. If not, please check the
line and confirm that the peer device is enabled.
Attention:
It is not allowed to excessively bend the fiber, and its
radius of curvature should be no less than 10cm;
Ensure the cleanliness of the fiber end face;
Please do not look directly into the fiber optic connector with your
eyes, as this may cause eye damage.

14
2.3 Check before power-on
Check that the power supply of the power outlet meets the switch
specifications.
Check that the power supply, switch, and rack are properly
grounded.
Check whether the switch is connected to other network devices.
2.4 Device initialization
The switch will automatically initialize after the power is turned on
and the power switch is turned on.
The indicator light will appear as follows:
After the power is turned on, the power indicator remains steady,
the SYS light enters the blinking state, and the system runs
normally.
The indicator of each port indicates the connection status of each
port, indicating that the switch has started to work normally.

15
Chapter 3 Product Installation
Before installation, confirm the operating environment of the
equipment: power supply voltage, installation space, installation
method, etc. Please carefully confirm the following installation
requirements:
- Check for cables and connectors required for
installation
- Check whether the cable is in place (not more than
100m) according to reasonable configuration requirements.
- The product does not provide mounting
components, the user must prepare the components of the
selected installation type: screws, nuts and tools to ensure reliable
installation
Power requirements:12-56V DC(12-48V nonsupport
PoE,support date exchange only)
Environmental requirements:
Working temperature: -40 ~ 75 ° C

16
Storage temperature: -40 to 75 ° C
Relative humidity: 5% to 95% (no condensation)
Power input
5pin 5.08mm terminal
Input range:12-56VDC
P1&P2 dual redundant power supply,
Support reverse connection protection
Ground protection
Connect to ground
Rail mounting

17
Chapter 4, Packing list and userecommendations
4. 1 Product packaging
Item
Quantity
Description
Switch
1 set
\
Phoenix terminal
1*5,1*2
each per
one unit
Connect to power and alarm switch
Warranty card
1 piece
For after-sales maintenance
User Manual
1 copy
Used to guide users to install
switches
4.2 Recommendations
1. For safety reasons, non-professionals should not open the
product casing;
2. Pay attention to the danger of strong electricity and safe
protection when the product is powered on;

18
3. Do not use the switch in a humid environment to prevent
water from entering the fuselage through the casing, resulting in
damage to the machine;
4. In the state of power-on of the product, please do not plug
and unplug the cable if non special case;
5. Please do not place heavy objects on the switch to avoid
accidents;
6. It is recommended to use the switch indoors. It is
recommended to add a waterproof box when using it outdoors.
Note: The pictures in the manual are for reference only,
whichever is subject to the actual product.
Table of contents
Other Hored Switch manuals

Hored
Hored AI106 User manual

Hored
Hored S5700-24G-24F-4TF User manual

Hored
Hored AI2010GX User manual

Hored
Hored IS104GS-2F User manual

Hored
Hored PS3016GS User manual

Hored
Hored AI106G-Apollo User manual

Hored
Hored PS3024GS User manual

Hored
Hored S5700-24G-4F-4TF User manual

Hored
Hored S5700-12G-12F User manual

Hored
Hored PS2024G User manual

Hored
Hored PS3016 User manual

Hored
Hored DF5700-24GP-4TF User manual

Hored
Hored S5700-24F-8G-4TF User manual

Hored
Hored PS2010G User manual

Hored
Hored AI606 User manual

Hored
Hored PS3024S User manual

Hored
Hored IS108S-4F User manual

Hored
Hored PS3016S User manual

Hored
Hored AI1010G-Apollo User manual

Hored
Hored IS104GPS-2F User manual