Thank you for purchasing the ServeRAID-MR10is Serial
Attached SCSI (SAS)/Serial ATA (SATA) Controller. The
ServeRAID-MR10is SAS/SATA Controller is a 1078-based
PCI Express RAID adapter.
Please take a few minutes to read this Quick Install Guide
before you install the controller. If you need more information
about any topic covered in this guide, refer to the other
documents on your ServeRAID-MR Support CD.
The ServeRAID-MR10is SAS/SATA Controller comes with
the ServeRAID-MR10is intelligent Battery Backup Unit
(iBBU) already connected directly to the board. You have the
option to connect the iBBU to the controller remotely.
Note:Refer to the remote iBBU flyer for information on
when to mount the iBBU remotely.
For more information about the battery, refer to the
ServeRAID-MR10is SAS/SATA Controller User’s Guide on
the ServeRAID-MR Support CD.
Note:The part number for this product is 44E8695. The
ServeRAID-MR10is SAS/SATA Controller is
identified by the part number stamped on the
device.
ServeRAID-MR10is SAS/SATA
CONTROLLER INSTALLATION
Perform the following steps to install the ServeRAID-MR10is
SAS/SATA Controller.
Step 1 Unpack the Controller
Unpack the controller in a static-free
environment. Remove the controller from the
antistatic bag and inspect it for damage.
If the controller appears to be damaged, or if the
ServeRAID-MR Support CD is missing, contact
your place of purchase.
The CD contains utility programs, device drivers
for various operating systems, and the following
documentation:
•ServeRAID-MR10is SAS/SATA Controller
User’s Guide
•ServeRAID-MR Software User’s Guide
•ServeRAID-MR10is Intelligent Battery Backup
Unit User’s Guide
•ServeRAID-MR Device Driver Installation
User’s Guide
Step 2 Prepare the Computer
Review all safety information provided with the
computer. Unplug the power cords from the
power supplies, disconnect the computer from
the network, and remove the computer cover.
Refer to the documentation provided with the
computer for instructions.
Step 3 Review the Connectors
Figure 1 shows the location of the connectors on
the controller.
Attention: Back up your data before you change your
system configuration. Otherwise, you might lose
data.
Important: When you handle static-sensitive devices, take
precautions to avoid damage from static
electricity.
Attention: Before you install the controller, make sure that
the computer is disconnected from the power and
from any networks.
ServeRAID-MR10is VAULT SAS/
SATA Controller
Quick Install Guide
2 of 3
Figure 1 ServeRAID-MR10is SAS/SATA
Controller Card Layout
Table 1 describes the connectors on the
controller.
Step 4 Install the Controller in the Computer
Insert the controller in a PCI Express slot on the
motherboard, as shown in Figure 2.
Press down gently but firmly to seat the card
correctly in the slot. Secure the controller to the
computer chassis with the bracket screw.
Note:Refer to your computer documentation for
information about the PCI Express slot.
Figure 2 Installing the ServeRAID-MR10is SAS/
SATA Controller
Step 5 Configure and Install the SAS Devices, SATA
II Devices or Both in the Host Computer Case
Configure the SAS devices, SATA II devices, or
both, and install them in the host computer.
Note:The ServeRAID-MR10is controller supports
SATA II protocols but not SATA I protocols. All
references to SATA in this document are to SATA
II.
Step 6 Connect the Controller to the SAS Devices,
SATA II Devices, or Both
Table 1 Connectors
Connector Type Description
J1 Board-to-board con-
nector for battery
backup unit daugh-
ter card
20-pin connector.
Provides an interface to the
daughter card that contains the
battery backup unit.
J2 Universal Asynchro-
nous Receiver/
Transmitter
debugging
4-pin connector.
Reserved for IBM use.
J3 Individual Activity
LED header for
eight SAS ports
16-pin connector.
Provides an LED interface individ-
ually to eight SAS ports. The LED
indicates activity on individual
drives.
J4 Individual Fault LED
header for eight
SAS ports
16-pin connector.
Provides an LED interface individ-
ually to eight SAS ports. The LED
indicates errors on individual
drives.
J5 Debug connector 2-pin connector.
Reserved for IBM use.
J6 Board Default
Debug
2-pin connector.
Reserved for IBM use.
J7 Cache Write Pend-
ing LED
2-pin connector.
The connector for the enclosure
LED. It provides a signal that indi-
cates when the on-board cache
contains data and a write from the
cache to the hard drives is pend-
ing. Optional.
J8 x8 SAS Ports 0–3 The x8 Mini SAS 4i ports connect
the cables from the controller to
SAS physical drives or SATA II
physical drives to a SAS
expander.
J9 x8 SAS Ports 4–7 The x8 Mini SAS 4i ports connect
the cables from the controller to
SAS physical drives or SATA II
physical drives to a SAS
expander.
J10 IPMI-style SMBus
(System Manage-
ment)/I2C header
3-pin shielded header.
Provides enclosure management
support.
Table 1 Connectors
Connector Type Description
IBM P/N: 46C8103 Version 1.0
First Edition (July 2008)
© Copyright International Business Machines Corporation 2008.
All rights reserved.
®
US Government Users Restricted Rights – Use, duplication or disclosure restricted
by GSA ADP Schedule Contract with IBM Corp.
LSI, the LSI logo design, and MyStorage are trademarks or registered trademarks
of LSI Corporation. All other brand and product names may be trademarks of their
respective companies.
Connect the cables between the controller and
the supported SAS devices or SATA II devices.
Refer to the device documentation to view
connector locations.
Note:Refer to the ServeRAID-MR10is SAS/SATA
Controller User’s Guide for information about the
cables and the connectors.
Step 7 Turn on the Power to the Computer
Replace the computer cover, and reconnect the
power cords. Turn on the power to the computer.
During boot, a MegaRAID BIOS message similar
to the following is displayed:
LSI MEGARAID BIOS VERSION xxxx [date]
Copyright(c) 2007, LSI Corporation
HA-1 (Bus x Dev y) MegaRAID 8708E
PCI-Express RAID Controller
Standard FW xxxx DRAM=xxx MB(SDRAM)
The firmware takes several seconds to initialize.
During this time the controller scans the bus(es).
Step 8 Run the WebBIOS Configuration Utility
Run the WebBIOS Configuration Utility to
configure the physical arrays and the logical
drives. When the message Press <Ctrl><H> for
WebBIOS displays on the screen, immediately
press CTRL+H to run the utility.
Note:Refer to the ServeRAID-MR Software User’s
Guide on the ServeRAID-MR Support CD for
detailed steps on configuring the physical arrays
and the logical drives.
Step 9 Install the Operating System Driver
The controller can operate under various
operating systems. To operate under these
operating systems, you must install software
drivers.
The ServeRAID-MR Support CD includes drivers
for the supported operating systems. You can
view the supported operating systems and
download the latest drivers for the controller at
http://www.ibm.com/systems/support/.
Refer to the ServeRAID-MR Device Driver
Installation User’s Guide on the CD for details on
installing the driver. Be sure to use the latest
Service Packs provided by the operating system
manufacturer and review the readme file that
accompanies the driver.
SUPPORTED RAID LEVELS
The ServeRAID-MR10is SAS/SATA Controller supports disk
arrays using the following RAID levels:
•RAID 0 (Data striping): Data is striped across all disks
in the array, enabling fast data throughput. There is no
data redundancy. All data is lost if any disk fails.
•RAID 1 (Disk mirroring): Data is written simultaneously
to two disks, providing complete data redundancy if one
disk fails. The maximum array capacity is equal to the
available size of the smaller of the two hard drives.
•RAID 5 (Disk striping with distributed parity): Data is
striped across all disks in the array. Part of the capacity
of each disk stores parity information that reconstructs
data if a disk fails. Provides good data throughput for
applications with high read request rates.
•RAID 6 (Disk striping with distributed parity across
two disks): Data is striped across all disks in the array
and two parity disks are used to provide protection
against the failure of up to two physical disks. In each row
of data blocks, two sets of parity data are stored.
•RAID 10 (RAID 1 and RAID 0 in spanned arrays): Uses
mirrored pairs of disks to provide complete data
redundancy. Provides high data throughput rates.
•RAID 50 (RAID 5 and RAID 0 in spanned arrays): Uses
both parity and disk striping across multiple disks to
provide complete data redundancy. Provides high data
throughput rates.
•RAID 60 (RAID 6 and RAID 0 in spanned arrays): RAID
60 uses both distributed parity across two parity disks and
disk striping across multiple disks to provide complete
data redundancy. RAID 60 provides high fault tolerance.
TECHNICAL SUPPORT
Refer to the Warranty and Support Information document for
information about the technical support available for this
product.
Attention: The battery in the iBBU must charge for at least
six hours under normal operating conditions. To
protect your data, the firmware changes the Write
Policy to write-through until the battery unit is
sufficiently charged. When the battery unit is
charged, the controller firmware changes the
Write Policy to write-back to take advantage of
the performance benefits of data caching.

Other manuals for ServeRAID-MR10is

1

Other IBM Controllers manuals

IBM 2074 Setup guide

IBM

IBM 2074 Setup guide

IBM ServeRAID M1215 SAS User manual

IBM

IBM ServeRAID M1215 SAS User manual

IBM ServeRAID-MR10is User manual

IBM

IBM ServeRAID-MR10is User manual

IBM 3708 Technical manual

IBM

IBM 3708 Technical manual

IBM FlashSystem 900 User manual

IBM

IBM FlashSystem 900 User manual

IBM ServeRAID M5025 User manual

IBM

IBM ServeRAID M5025 User manual

IBM 3720 User manual

IBM

IBM 3720 User manual

IBM 950 User manual

IBM

IBM 950 User manual

IBM 3746 User manual

IBM

IBM 3746 User manual

IBM ServeRAID-4 Ultra160 Series Service manual

IBM

IBM ServeRAID-4 Ultra160 Series Service manual

IBM 3174 User manual

IBM

IBM 3174 User manual

IBM CPC700 User manual

IBM

IBM CPC700 User manual

IBM ServeRAID Service manual

IBM

IBM ServeRAID Service manual

IBM ServeRAID M5210 User manual

IBM

IBM ServeRAID M5210 User manual

IBM 3708 Service manual

IBM

IBM 3708 Service manual

IBM Netfinity ServeRAID-4H Ultra160 Service manual

IBM

IBM Netfinity ServeRAID-4H Ultra160 Service manual

IBM BladeCenter T Series User manual

IBM

IBM BladeCenter T Series User manual

IBM TotalStorage User manual

IBM

IBM TotalStorage User manual

IBM ServeRAID-8 Series Instructions for use

IBM

IBM ServeRAID-8 Series Instructions for use

IBM ServeRAID M5016 User manual

IBM

IBM ServeRAID M5016 User manual

IBM ServeRAID M5025 User manual

IBM

IBM ServeRAID M5025 User manual

IBM 8248-L4T User manual

IBM

IBM 8248-L4T User manual

IBM ThinkPad 130 Reference manual

IBM

IBM ThinkPad 130 Reference manual

IBM 3745 21A User manual

IBM

IBM 3745 21A User manual

Popular Controllers manuals by other brands

SOMFY animeo KNX 1860286 installation guide

SOMFY

SOMFY animeo KNX 1860286 installation guide

Beckhoff EP4174-0002 Documentation

Beckhoff

Beckhoff EP4174-0002 Documentation

Sit 710 MINISIT user manual

Sit

Sit 710 MINISIT user manual

Bardac 3600XRi manual

Bardac

Bardac 3600XRi manual

Griven AL1419 instruction manual

Griven

Griven AL1419 instruction manual

Netro SPRITE quick start guide

Netro

Netro SPRITE quick start guide

MegaTec NetAgent Mini user manual

MegaTec

MegaTec NetAgent Mini user manual

Emerson Copeland Site Supervisor Controller Quick setup guide

Emerson

Emerson Copeland Site Supervisor Controller Quick setup guide

Kampmann 30515 Assembly and installation instructions

Kampmann

Kampmann 30515 Assembly and installation instructions

Jobsite V-10-50 Installation & user guide

Jobsite

Jobsite V-10-50 Installation & user guide

Norac UC4+ installation manual

Norac

Norac UC4+ installation manual

EDFM FX LOOPER user manual

EDFM

EDFM FX LOOPER user manual

Alltrax DCX user manual

Alltrax

Alltrax DCX user manual

ABB 07CR41 operating manual

ABB

ABB 07CR41 operating manual

Watlow DIN-A-MITE C user manual

Watlow

Watlow DIN-A-MITE C user manual

Danfoss ECL Comfort 310 installation guide

Danfoss

Danfoss ECL Comfort 310 installation guide

C-LOGIC 502-PC instruction manual

C-LOGIC

C-LOGIC 502-PC instruction manual

Moxa Technologies ioThinx 4510 Series user manual

Moxa Technologies

Moxa Technologies ioThinx 4510 Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.