JS-20 LARGO,P.I.R. detector MGD51208
JS-20 „LARGO“ P.I.R. detector
This P.I.R. motion detector is
used to protect interiors. It detects
any movement of objects with a
temperature close to that of the
human body.
The signal from the sensor is
electronically analyzed. This ensures
that the detector provides excellent
sensitivity and at the same time false
alarms are basically eliminated. The
detection analysis rate can be
adjusted to increase its immunity if
the JS-20 is installed in a
problematic location.
The standard lens in the detector
can be replaced with an optional
corridor or pet immune lens. Extra
terminals (GBS) can be used to
facilitate wiring of the detector.
The JS-20 distinguishes itself
with excellent RF immunity.
It can be mounted on a flat wall
or in a corner.
Installation
This detector is designed for
indoor applications. It can be mounted on a flat wall or in a corner. Do not
place the detector close to any heating/cooling vents or near any other object
that often change temperature. The detector must have an unobstructed view
of the protected area.
1. Open the cover of the detector (press in the plastic tab on the bottom
part of the detector’s housing with a screwdriver).
2. Remove the PCB by pressing the flexible tab inside the housing.
3. Punch through the pre-formed holes for cables and screws.
4. Attach the housing to the wall (2.5 meters above the floor).
5. Return the PCB into the rear housing and connect the cable wires to
the terminals.
6. Attach the cover.
Note: Avoiding touching or scratching the PIR sensor!
Terminals
+12V, GND power supply
PIR, PIR PIR alarm output (normally closed)
TMP, TMP TAMPER output (normally closed)
GBS, GBS auxiliary terminals – useful when wiring (see examples)
Jumpers
LED the LED indicator can be disabled by opening this jumper
DETECTION by opening this jumper you can set a higher rate of analysis
and increase the immunity of the detector. This setting is
suitable for problematic locations with sudden temperatures
changes or electromagnetic interference. Reaction of the
detector will be slightly slower in this setting.
Detector testing
•After switching on the power, wait for 1 minute. During this period the
detector initializes and stabilizes its parameters (LED will be on if not
disabled).
•Each detected movement will be indicated by the detector’s LED (if not
disabled)
•Confirm that the detector covers the protected area as you expected.
Lenses
Standard lens that is supplied with the JS-20 Largo detector covers an
area of 120 degrees / 12 meters.
For special applications other lenses can be used. Optional lenses for long
corridors and areas with small animals are supplied separately.
The Pet lens is marked JS-7910. This lens prevents animals smaller then
40 cm to be detected by the detector. The working range of this lens is
reduced to 7 meters. It is recommended to test this lens carefully with the
animal when installing the system, in order to prevent false alarms.
The Corridor lens is marked JS-7904. The working range of this lens is
25 meters long and only 3 meters wide. It is recommended to test the
detector’s sensitivity carefully when installing it into a corridor.
The curtain lens is marked JS-7902. By using this lens the PIR detector's
working range is restricted to a "curtain". After using this lens, it is for
example possible to secure part of a room etc. During the installation it is
necessary to test the working range very carefully.
Lens characteristic diagrams can be seen in documents supplied with
the lens or on the Jablotron website www.jablotron.com .
Note: Although this product does not contain any harmful materials we
suggest you to return the product to the dealer or directly to the producer
after usage.
Specification
Power supply: 12 V DC ± 25%
Power consumption (LED off): max. 10 mA
Maximum consumption (LED on): max. 35 mA
Terminals size: max. 1 mm2
Mounting height: 2.5 m above floor
Detection range: 120° / 12 m (standard lens)
Initialization: aprox. 1 minute
Alarm output: normally closed, max. 60V / 50 mA,
internal resistance max.30 Ohm
Tamper output: normally closed, max. 60 V / 50 mA,
internal resistance max.16 Ohm
Environment - class II. – general indoor, (EN 50131-1)
Operating temperatures -10 to +40 °C
Security level grade 2, EN 50131-1, EN 50131-2-2
EMC EN 50130-4, EN 55022
JABLOTRON ALARMS a.s. hereby declares that the JS-20 is in a
compliance with the relevant Union harmonisation legislation:
Directives No: 2014/30/EU, 2011/65/EU. The original of the
conformity assessment can be found at www.jablotron.com -
Section Downloads.
Note: Although this product does not contain any harmful materials
we suggest you return the product to the dealer or directly to the
manufacturer after use.
JS-20 LARGO,P.I.R. detector MGD51208
Examples of wiring the JS-20 Largo detector using end-of-line resistors and double end-of-line resistors
(Auxiliary GBS terminals are used to facilitate the wiring)
Example of wiring of several JS-20 Largo detectors into the double EOL loop
(Auxiliary GBS terminals are used to facilitate wiring)
Example of wiring of several JS-20 Largo detectors into the EOL loop
(Auxiliary GBS terminals are used to facilitate the wiring)

Other jablotron Security Sensor manuals

jablotron JA-155P User manual

jablotron

jablotron JA-155P User manual

jablotron JA-60V User manual

jablotron

jablotron JA-60V User manual

jablotron JA-152SHM User manual

jablotron

jablotron JA-152SHM User manual

jablotron JA-120PW User manual

jablotron

jablotron JA-120PW User manual

jablotron JA-158P User manual

jablotron

jablotron JA-158P User manual

jablotron JA-111ST User manual

jablotron

jablotron JA-111ST User manual

jablotron JA-150P User manual

jablotron

jablotron JA-150P User manual

jablotron JA-84P User manual

jablotron

jablotron JA-84P User manual

jablotron JA-157P User manual

jablotron

jablotron JA-157P User manual

jablotron JS-20 User manual

jablotron

jablotron JS-20 User manual

jablotron JA-120PC User manual

jablotron

jablotron JA-120PC User manual

jablotron JA-158P User manual

jablotron

jablotron JA-158P User manual

jablotron JA-169P User manual

jablotron

jablotron JA-169P User manual

jablotron JA-83M User manual

jablotron

jablotron JA-83M User manual

jablotron CA-550 User manual

jablotron

jablotron CA-550 User manual

jablotron JA-160PC User manual

jablotron

jablotron JA-160PC User manual

jablotron JA-80S User manual

jablotron

jablotron JA-80S User manual

jablotron JA-159P User manual

jablotron

jablotron JA-159P User manual

jablotron JA-120PC User manual

jablotron

jablotron JA-120PC User manual

jablotron JA-60P User manual

jablotron

jablotron JA-60P User manual

jablotron JA-81M User manual

jablotron

jablotron JA-81M User manual

jablotron JA-180PB User manual

jablotron

jablotron JA-180PB User manual

jablotron JA-158P User manual

jablotron

jablotron JA-158P User manual

jablotron JA-188P User manual

jablotron

jablotron JA-188P User manual

Popular Security Sensor manuals by other brands

Trader SCORPION SCSPSENSORBK instructions

Trader

Trader SCORPION SCSPSENSORBK instructions

Visonic DISCOVERY PIR MCW - INSTALLER GUIDE installation instructions

Visonic

Visonic DISCOVERY PIR MCW - INSTALLER GUIDE installation instructions

BEINAT SGM595 manual

BEINAT

BEINAT SGM595 manual

DoorKing 9411 Single Channel with Aux Relay Information manual

DoorKing

DoorKing 9411 Single Channel with Aux Relay Information manual

Green Brook Orion Range OD101 manual

Green Brook

Green Brook Orion Range OD101 manual

WABCO TAILGUARD manual

WABCO

WABCO TAILGUARD manual

Paradox NV5 installation instructions

Paradox

Paradox NV5 installation instructions

SmartSafe iSmartE VP01 user manual

SmartSafe

SmartSafe iSmartE VP01 user manual

Mastech MS5905RTB manual

Mastech

Mastech MS5905RTB manual

Bosch Blue Line D1-P quick start guide

Bosch

Bosch Blue Line D1-P quick start guide

GTE ADICOS M-BUSMASTER S operating manual

GTE

GTE ADICOS M-BUSMASTER S operating manual

LightPro 227A user manual

LightPro

LightPro 227A user manual

Honeywell FS19X Series Installation guide and operating manual

Honeywell

Honeywell FS19X Series Installation guide and operating manual

PoliceCam PC-2620 CO user manual

PoliceCam

PoliceCam PC-2620 CO user manual

H2Scan HY-ALERTA 500 operating manual

H2Scan

H2Scan HY-ALERTA 500 operating manual

Hytronik Dual Sense HIM16 manual

Hytronik

Hytronik Dual Sense HIM16 manual

DITECH LS quick start guide

DITECH

DITECH LS quick start guide

Megger VF5 user guide

Megger

Megger VF5 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.