manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. jablotron
  6. •
  7. Security Sensor
  8. •
  9. jablotron JA-152M User manual

jablotron JA-152M User manual

JABLOTRON ALARMS a.s.
Pod Skalkou 4567/33 46601 Jablonec n. Nisou
Czech Republic www.jablotron.com
||
|
The JA-152M Wireless hidden magnetic detector
The JA-152M Wireless hidden magnetic detector 1 / 2 MKC55101
The JA-152M is a wireless component of the JABLOTRON 100
system. It is used to detect the opening of doors and windows and
is designed for hidden installation (between a frame and a wing).
The detector has a status reaction that can be switched to a pulse
reaction if necessary. The detector takes one position in the system and
it should be installed by a trained technician with a valid certificate
issued by an authorized distributor. This product is compatible with
the JA-103K, JA-107K and subsequent control panels.
Installation
The detector should be placed into the gap between the frame (non-
moving part) and the wing (moving part) of a door or window. There are
various door/window frames, therefore it is wise to verify before
installation that the detector fits the given door/window type. In the case
of a wooden frame with too narrow a profile it is usually possible to mill
out a groove for detector insertion.
The detector electronics should be installed onto the non-moving part
and the magnet onto the moving part. The detector reacts to the
removal of its magnet. If the supplied magnet does not exactly match
the door/window construction you can ask the window/door supplier for
a magnet of a suitable type. Alternatively, you can adjust the magnet’s
position using a suitable back-plate.
Figure: 1 – magnet; 2 – tear-removal mechanism for removal detection (on the back side
of the detector); 3 – cover tamper sensor; 4 – batteries (2x CR 2032);
5 – hidden LED indicators (under the logo); 6 – adjustment line; 7 – fixing holes
1. Find a suitable place for the detector’s location so that the magnet
is aligned with the adjustment line (6) when the door/window
is closed. After opening the door/window, the magnet’s distance
from the detector should increase by at least 2 cm.
Basic installation conditions:
a) Avoid installing the detector in the area of the metal fitting
mechanism (there shouldn’t be any metal close to the detector
due to interference to radio communication),
b) We do not recommend installing the detector onto the bottom
part of the door/window frame due to possible water
condensation,
c) There are two 2mm and one 3mm back-plates designed
to compensate for possible unevenness on the frame (e.g.
frame grooves); the detector must always lie with its whole
surface on the mounting surface.
2. Screw the magnet onto the moving part of the door/window
according to the following picture.
3. Unscrew the battery cover and screw the detector on with four
screws so that the magnet is aligned with the adjustment line (6)
when the door/window is closed. Be careful not to use too much
force while tightening the screws, otherwise the tear-removal
mechanism (2) could be damaged.
4. Try out if the detector or the magnet makes no obstruction when
closing the door/window.
5. Follow the instructions stated in the control panel installation
manual. Basic procedure:
a) Open the F-Link software, select an unused position
in the Devices tab and click on the Enroll button to enter
the Enrollment mode.
b) Insert both batteries (4) into the detector. Mind the correct
polarity (for both batteries the positive terminal points
upwards). After the second battery is inserted into the detector
the enrollment signal is transmitted and the detector
is enrolled into the selected position. The enrollment
is confirmed by the yellow LED (5) turning off.
c) Close and screw the detector cover on.
Note:
The detector can also be enrolled into the system by entering its
production code in the F-Link software. You can find the production
code on the sticker placed on the back side of the detector.
All numbers under the bar code shall be entered (1400-00-0000-0001).
−If you want to remove the device from the system, erase it from its
position in the F-Link software.
Detector communication with the system
The detector is equipped with bi-directional asynchronous
communication with the JA-11xR radio module which enables changing
the internal settings with ease (just as it is with BUS detectors) while
taking into account battery life time in normal operational mode.
When the detector is enrolled to the control panel it works in the so-
called accelerated 90-second mode until the Service mode
is terminated (up to 24h). The detector performs a check every 90s
to monitor whether the control panel remains in the Service mode,
whether it should apply new settings or should the LED light indicate
opening of the door/window.
In the normal operational mode, the detector communicates
periodically with the control panel 1x every 20 minutes. Therefore,
it may take the detector up to 20 minutes to realize the control panel
was switched to the Service mode or to save changes made
in the internal settings. This period of time can be shorten by triggering
the detector which will switch it to the accelerated 90-second mode
immediately (increasing the magnet’s distance from the detector
by at least 2 cm, opening it = triggering the tamper contact).
Important:
It is not necessary to wait for 90s (or 20 minutes) for the detector
to confirm a request to save the changes made in the internal settings.
The control panel remembers such changes and transfers them
to the detector the next time a periodical communication session
occurs.
Setting the detector properties
Impulse behaviour: (*OFF) If set ON, the detector generates
an activation, but does not detect the status/position
of the door/window. If set to OFF, standard status behaviour is enabled,
meaning the system knows about the status of the door/window
the whole time a door/window is open and the detector remains active.
Disabled rear tamper sensor:(*OFF) The parameter enables/disables
the rear tamper sensors which monitor detector removal from the surface.
Detector testing
When in Service mode, the LED indicators (5) in the detector indicate
every activation when opening/closing. Individual activations
of the detector can also be monitored in the Diagnostics tab
in the F-Link software.
The LED indicators, including the yellow fault indicator, are disabled
in normal operating mode.
Battery replacement
The system automatically reports a low battery status. Remember
to switch the system to Service mode before changing the batteries
(otherwise a tamper alarm will be triggered). Use only high-quality
lithium batteries, type CR2032. Always replace both batteries
at the same time.
CR2032
3V
+
CR2032
3V
4
191
7
24
0-10
2xCR2032
1
3
2457
6
The JA-152M Wireless hidden magnetic detector
The JA-152M Wireless hidden magnetic detector 2 / 2 MKC55101
Technical specifications
Power 2x lithium batteriey, type CR2032 (3.0 V / 0.2 Ah)
Please note: batteries are not included
Typical battery lifetime approx. 2 years
Low battery voltage < 2.4 V
Current consumption 4 μA
Maximum current consumption 40 mA
Communication band 868.1 MHz, JABLOTRON protocol
RF range approx. 300 m (open area)
Dimensions 191 x 24 x 7 mm
Weight (without batteries) 32 g
Classification Grade 2 / II. indoor general
(According to EN 50131-1)
Operational environment extended indoor general
Operational temperature range -20 °C to +60 °C
Average operational humidity 75 % RH, non-condensing
Certification body Trezor Test s.r.o. (no. 3025)
Also complies with EN 50131-1 ed. 2+A1+A2, EN 50131-2-6,
EN 50131-5-3+A1, EN 50131-6 ed. 2+A1, ETSI EN 300 220-1-2,
EN 50130-4 ed. 2+A1, EN 55032, EN 62368-1, EN 50581
Can be operated according to ERC REC 70-30
JABLOTRON ALARMS a.s. hereby declares that the JA-152M
is in compliance with the relevant European Union
harmonisation legislation: Directives No: 2014/53/EU, 2014/35/EU,
2014/30/EU, 2011/65/EU, when used as intended.
The original
of the conformity assessment can be found at www.jablotron.com
– the Downloads section.
Note: Although this product does
not contain any harmful
materials we suggest you return the product to the dealer
or directly to the producer after use.

Other jablotron Security Sensor manuals

jablotron JA-85P User manual

jablotron

jablotron JA-85P User manual

jablotron JA-122PW User manual

jablotron

jablotron JA-122PW User manual

jablotron JA-80PB User manual

jablotron

jablotron JA-80PB User manual

jablotron LARGO JS-20 User manual

jablotron

jablotron LARGO JS-20 User manual

jablotron JA-111TH User manual

jablotron

jablotron JA-111TH User manual

jablotron JA-120PC User manual

jablotron

jablotron JA-120PC User manual

jablotron JA-120PC User manual

jablotron

jablotron JA-120PC User manual

jablotron Ei208W User manual

jablotron

jablotron Ei208W User manual

jablotron JA-80S User manual

jablotron

jablotron JA-80S User manual

jablotron JA-115P User manual

jablotron

jablotron JA-115P User manual

jablotron JA-152P User manual

jablotron

jablotron JA-152P User manual

jablotron JA-84P User manual

jablotron

jablotron JA-84P User manual

jablotron OS-300 User manual

jablotron

jablotron OS-300 User manual

jablotron JA-180S User manual

jablotron

jablotron JA-180S User manual

jablotron JA-120PW User manual

jablotron

jablotron JA-120PW User manual

jablotron JA-159P User manual

jablotron

jablotron JA-159P User manual

jablotron JA-151TH User manual

jablotron

jablotron JA-151TH User manual

jablotron JA-120PC User manual

jablotron

jablotron JA-120PC User manual

jablotron JA-155P User manual

jablotron

jablotron JA-155P User manual

jablotron JA-151P-WG User manual

jablotron

jablotron JA-151P-WG User manual

jablotron JA-83P User manual

jablotron

jablotron JA-83P User manual

jablotron JA-152SHM User manual

jablotron

jablotron JA-152SHM User manual

jablotron JA-169P User manual

jablotron

jablotron JA-169P User manual

jablotron JA-83M User manual

jablotron

jablotron JA-83M User manual

Popular Security Sensor manuals by other brands

Kutai electronics V-DOG2 user manual

Kutai electronics

Kutai electronics V-DOG2 user manual

Nortek Security & Control 2GIG-DW20R-345 installation instructions

Nortek Security & Control

Nortek Security & Control 2GIG-DW20R-345 installation instructions

PUFF Alert-C manual

PUFF

PUFF Alert-C manual

Guardian 04664 instruction manual

Guardian

Guardian 04664 instruction manual

Diablo Controls, Inc. DSP-55 user manual

Diablo Controls, Inc.

Diablo Controls, Inc. DSP-55 user manual

Zennio EyeZen TP user manual

Zennio

Zennio EyeZen TP user manual

Schmidt SS 20.415 LED Instructions for use

Schmidt

Schmidt SS 20.415 LED Instructions for use

Bircher Reglomat Merkur 2 Series operating instructions

Bircher Reglomat

Bircher Reglomat Merkur 2 Series operating instructions

Eaton EF-CBD130 Installation and operation manual

Eaton

Eaton EF-CBD130 Installation and operation manual

Tractel HT33 manual

Tractel

Tractel HT33 manual

Ortech DHOS Installation instruction

Ortech

Ortech DHOS Installation instruction

Alarmtech MC 746-E instruction manual

Alarmtech

Alarmtech MC 746-E instruction manual

Graco Fluid Defender 25V475 instructions

Graco

Graco Fluid Defender 25V475 instructions

Gems Sensors Warrick 2820 Series Installation and Operation Bulletin

Gems Sensors

Gems Sensors Warrick 2820 Series Installation and Operation Bulletin

Edimax AI-2002W user manual

Edimax

Edimax AI-2002W user manual

BEA CRYSTAL user guide

BEA

BEA CRYSTAL user guide

Emos E00387 manual

Emos

Emos E00387 manual

FTS DTS-12 user manual

FTS

FTS DTS-12 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.