manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Kaba Mas
  6. •
  7. Lock
  8. •
  9. Kaba Mas LA GARD SMARTLINC Operation instructions

Kaba Mas LA GARD SMARTLINC Operation instructions

Other Kaba Mas Lock manuals

Kaba Mas X-10 User manual

Kaba Mas

Kaba Mas X-10 User manual

Kaba Mas AUDITCON 2 Series User manual

Kaba Mas

Kaba Mas AUDITCON 2 Series User manual

Kaba Mas LCLX User manual

Kaba Mas

Kaba Mas LCLX User manual

Kaba Mas X-09 User manual

Kaba Mas

Kaba Mas X-09 User manual

Kaba Mas 252 User manual

Kaba Mas

Kaba Mas 252 User manual

Kaba Mas DKX Series User manual

Kaba Mas

Kaba Mas DKX Series User manual

Kaba Mas Low Profile 52 series User manual

Kaba Mas

Kaba Mas Low Profile 52 series User manual

Kaba Mas Unicon CL20 User manual

Kaba Mas

Kaba Mas Unicon CL20 User manual

Kaba Mas LA GARD COMBOGARDPRO 39E Manual

Kaba Mas

Kaba Mas LA GARD COMBOGARDPRO 39E Manual

Kaba Mas AUDITCON 100 series User manual

Kaba Mas

Kaba Mas AUDITCON 100 series User manual

Kaba Mas Unicon CL Series User manual

Kaba Mas

Kaba Mas Unicon CL Series User manual

Kaba Mas X-09 User manual

Kaba Mas

Kaba Mas X-09 User manual

Kaba Mas LA Gard Combogard 33E Owner's manual

Kaba Mas

Kaba Mas LA Gard Combogard 33E Owner's manual

Kaba Mas AUDITCON 2 Series User manual

Kaba Mas

Kaba Mas AUDITCON 2 Series User manual

Kaba Mas Auditcon 52R User manual

Kaba Mas

Kaba Mas Auditcon 52R User manual

Kaba Mas Unicon CL Series User manual

Kaba Mas

Kaba Mas Unicon CL Series User manual

Kaba Mas LA GARD BASIC 3802 User manual

Kaba Mas

Kaba Mas LA GARD BASIC 3802 User manual

Kaba Mas Cencon 4 User manual

Kaba Mas

Kaba Mas Cencon 4 User manual

Kaba Mas Auditcon 252V User manual

Kaba Mas

Kaba Mas Auditcon 252V User manual

Kaba Mas X-10 User manual

Kaba Mas

Kaba Mas X-10 User manual

Kaba Mas AUDITCON 2 Series User manual

Kaba Mas

Kaba Mas AUDITCON 2 Series User manual

Kaba Mas UNICON User manual

Kaba Mas

Kaba Mas UNICON User manual

Kaba Mas CDX-10 Manual

Kaba Mas

Kaba Mas CDX-10 Manual

Kaba Mas Cencon MDB 30N User manual

Kaba Mas

Kaba Mas Cencon MDB 30N User manual

Popular Lock manuals by other brands

Magic 105 manual

Magic

Magic 105 manual

Gantner GAT NET.Lock 7020 System Installation, configuration & operation

Gantner

Gantner GAT NET.Lock 7020 System Installation, configuration & operation

Dorma Studio Classic Installation instruction

Dorma

Dorma Studio Classic Installation instruction

Securam ECSL-601 quick start guide

Securam

Securam ECSL-601 quick start guide

Sudhaus 3003 operating manual

Sudhaus

Sudhaus 3003 operating manual

Safety 1st 48517 user guide

Safety 1st

Safety 1st 48517 user guide

Pado FDS-10 user manual

Pado

Pado FDS-10 user manual

Esco systeQ Series installation instructions

Esco

Esco systeQ Series installation instructions

COMPX National D8951 instruction sheet

COMPX

COMPX National D8951 instruction sheet

secureo Key Box instruction manual

secureo

secureo Key Box instruction manual

Stock Loks C8713 instruction sheet

Stock Loks

Stock Loks C8713 instruction sheet

COMPX 1T-058 Information

COMPX

COMPX 1T-058 Information

Auslock T11 user manual

Auslock

Auslock T11 user manual

Stealth SAFES ShadowVault Instructions & Troubleshooting

Stealth SAFES

Stealth SAFES ShadowVault Instructions & Troubleshooting

Knox KeySecure 5 Admin & user guide

Knox

Knox KeySecure 5 Admin & user guide

Kwikset 48334/01 Quick installation guide

Kwikset

Kwikset 48334/01 Quick installation guide

Metra Electronics Door Access Terminal Combo Technical manual

Metra Electronics

Metra Electronics Door Access Terminal Combo Technical manual

Kilitronik miniK10m operating manual

Kilitronik

Kilitronik miniK10m operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

SMARTLINC
Multiple Lock System
user operating instructions
CHANGING YOUR CODE
ALWAYS PERFORM THIS OPERATION WITH
THE DOOR OPEN
If you have access to multiple locks, you must
repeat this procedure on each lock you have
access to.
1. Press any key to power up SMARTLINC.
 • Displaywillshoweither“ENTERCOMBO”
  or“SELECTLOCK”whentwoormorelocks
  areinstalled.
2.Selectlockiftwoormorelocksareinstalled.
3.Enter“zero”sixtimes
4.Enterexistingsix(6)digitcodeonetime(and
 inserteKeyII,ifset-up).
5.EnterNEWsix(6)digitcodetwotimes(and
 inserteKeyII,ifset-up,after2ndentry).
 • IfavalidcodeisenteredtheLCDwilldisplay
  “USERUPDATED”
6.Ifamistakeismadewaitthirty(30)seconds
 andrepeatsteps1-4.
 • OldCodewillremainvalidifamistakeismade.
 • Incaseofamistake,LCDwilldisplay“ERROR!”
7.Testlockoperationseveraltimesbeforeclosingthedoor.
CHANGING YOUR BATTERY
1.Removeblackplasticbatterycompartmentcover(located
 atthebottomofthekeypad)bygentlypullingdownwardon
 itshandle.
2.Allowthebatteryanditsattachedleadstodropdownand
 outofthebatterycompartment.Ifitdoesnotdrop,gently
 pullonthebatteryuntilitdoes.
3.Removetheconnectorbyunsnappingitfromthetwo
 terminalsonthetopofthebattery.
Never Pull on the Battery Leads
4.Connectanew9-VoltAlkalinebatterytothebatteryclip.
5.Pushthebatteryandtheleadscompletelyupintothe
 batterycompartment.
6.Installthebatterycoverbyplacingone
 sideofthecoverinpositionandthen
 pressingtheothersideintopositionwith
 yournger.
WARNING: The port for the eKEYII is a data
port only. Connecting power to this port will
damage the system.
NOTE:Thissystemcomesequippedwithan
AuxiliaryPowerBox(APB).Ifprimarypoweris
lost,theAPBwillmaintainpowertotheaudit
clockfor90hours.THE UNIT WILL NOT
FUNCTION UNTIL PRIMARY HAS BEEN
RE-ESTABLISHED, i.e. batteries have been
replaced or A/C power has been connected.
AVAILABLE FEATURES
USER CODE
• OpenLock
• ChangeCode
• SetImmediateTimeLock,ifenabled
• TimeDelayExtension,ifenabled
• TemporaryTimeLock,ifenabled
MULTIPLE LOCKS
• UptoFive
TIME DELAY
• Programmableoneachlock
  - DelayPeriod:1-99minutes
  - OpenPeriod:1-19minutes
• TwoTimeDelaysCanRunAtOnce
DUAL CODE
• TwoCodesrequiredtoopen
eKEYII MODE
• Programmableoneachlock;requirescodeandkeyforentry
• AvailabletoManagerandUsersonly,ifenabled
WRONG TRY PENALTY
• Four(4)consecutiveinvalidcodesinitiatesveminutedelayperiod
LOW BATTERY WARNING
• Repeatedaudioandvisualsignal(LCDreadoutandrepeated
 beeping)duringopeningindicatesbatterylow
AUDIO AND VISUAL SIGNAL
• Doublesignal(LCDreadoutandunitbeeps)indicatesentryisvalid
 oraccepted
• Triplesignalindicatesinvalidornotaccepted
TIME LOCK
Ifenabled,seeManagerInstructionsforoperation.
©copyright2006 (P/N)12-245v3•9/08 Kaba Mas LLC
page1of2
OptionaleKeyII
P/N40169
SELECT LOCK
XX
ENTER COMBO
X-X-X-X-X-X
OLD CODE
X-X-X-X-X-X
NEW CODE
X-X-X-X-X-X
CONFIRM NEW
X-X-X-X-X-X
USER
UPDATED
ERROR!
Please note: If using the SMARTLINC with the eKEYII feature, remove the key after each insertion to begin the next step. If the eKEYII is
left in the key port, the SMARTLINC will not respond to any key stroke.
©copyright2006 (P/N)12-245v3•9/08 Kaba Mas LLC
page2of2
OPENING THE LOCK(WITHOUTTIMEDELAY)
1. Press any key to power up SMARTLINC.
 • Displaywillshoweither“ENTERCOMBO”or“SELECTLOCK”whentwoormorelocksareinstalled.
2.Selectlockiftwoormorelocksareinstalled.
3.Enteravalid6(six)digitcode(andinserttheeKeyII,ifset-up)
 • IfavalidcodeisenteredtheLCDwilldisplay“OPEN”
4.OpentheDoorwithin3seconds.
 • Beforepower-off,LCDwilldisplaycurrentdateandtime.
• InvalidcodewillpromptLCDtodisplay“NOTVALIDUSER”
• Displaywillpower-offafter30secondsofnon-operation.
OPENING THE LOCK (WITHTIMEDELAY)
1. Press any key to power up SMARTLINC.
 • Displaywillshoweither“ENTERCOMBO”or“SELECTLOCK”whentwoormore,locksareinstalled.
2.Selectlockiftwoormorelocksareinstalled.
3.Enteravalid6(six)digitcode(andinserteKeyII,ifsetup)
 • IfTimeDelayhasbeensettheLCDwillshow“TIMEDELAY”andthecountingtime.
 • Countingisupdatedeverysecond,ifdisplayed.
 • Press“0”toabortTimeDelay DELAYABORTED!
 • AfterTimeDelayhaselapsed,thedisplaywillshow“mm:ss”(openwindowcountingtime).Unitwillbeepevery
  ve(5)secondsduringcountdown.
4.Enteravalidcode(andinserteKeyII,ifsetup)toopen.
 • IfavalidcodeisenteredtheLCDwilldisplay“OPEN”
5.Openthedoorwithin3seconds.
 • InvalidcodewillpromptLCDtodisplay“NOTVALIDUSER”
• Displaywillpower-offafter30secondsofnon-operation.
• IfusingtheTimeDelayOverride(USER#9),enterUSERcodeforUSER#9andinserteKeyII.
NOTE: To open a 2nd lock while one is in Time Delay, press the “P” key and select that lock number, then follow opening procedure
above. During Time Delay only the “P” and the zero key are active.
OPENING THE LOCK(WITHDUALCODEANDTIMEDELAY)
1. Press any key to power up SMARTLINC.
 • Displaywillshoweither“ENTERCOMBO”or“SELECTLOCK”whentwoormorelocksareinstalled.
2.Selectlockiftwoormorelocksareinstalled.
3.Enteravalid6(six)digitcode(andinserteKeyII,ifsetup)
 • IfTimeDelayhasbeensettheLCDwillshow“TIMEDELAY”andthecountingtime.
 • Countingisupdatedeverysecond,ifdisplayed.
 • Press“0”toabortTimeDelay DELAYABORTED!
• AfterTimeDelayhaselapsed,thedisplaywillshow“mm:ss”(openwindowcountingtime).
4.Enteravalid6(six)digitcode(andinserteKeyII,ifsetup)
5.Entera2ndvalid6(six)digitcode(andinserteKeyII,ifsetup)
 • IfavalidcodeisenteredtheLCDwilldisplay“OPEN”
 • IftheOverrideUser(#9)isinstalledwithDualCode,User#9mustentertheircode(andinserteKeyII,
  ifsetup)rst.
6.Openthedoorwithin3seconds.
• InvalidcodewillpromptLCDtodisplay“NOTVALIDUSER”
• Displaywillpower-offafter30secondsofnon-operation.
NOTE: To open a 2nd lock while one is in Time Delay, press the “P” key and select that lock number then follow opening
procedure above.
OPENING THE LOCK (WITHDUALCODE-NOTIMEDELAY)
1. Press any key to power up SMARTLINC.
 • Displaywillshoweither“ENTERCOMBO”or“SELECTLOCK”whentwoormorelocksareinstalled.
2.Selectlockiftwoormorelocksareinstalled.
3.Enteravalid6(six)digitcode(andinserteKeyII,ifsetup)
4.Entera2ndvalid6(six)digitcode(andinserteKeyII,ifsetup)
 • IfavalidcodeisenteredtheLCDwilldisplay“OPEN”
5.Openthedoorwithin3seconds.
 • Beforepower-off,LCDwilldisplaycurrentdateandtime.
• InvalidcodewillpromptLCDtodisplay“NOTVALIDUSER”.
• Displaywillpower-offafter30secondsofnon-operation.
SELECT LOCK
XX
SELECT LOCK
XX
SELECT LOCK
XX
SELECT LOCK
XX
ENTER COMBO
X-X-X-X-X-X
ENTER COMBO
X-X-X-X-X-X
ENTER COMBO
X-X-X-X-X-X
ENTER COMBO
X-X-X-X-X-X
OPEN!
TIME DELAY
14:31
TIME DELAY
14:31
2nd CODE
X-X-X-X-X-X
NOT VALID
USER!
03:51
X-X-X-X-X-X
03:51
X-X-X-X-X-X
2nd CODE
X-X-X-X-X-X
OPEN!
OPEN!
OPEN!
NOT VALID
USER!