Hiker Water Microfilter
(Model #8013629 or 8014531)
Hiker Replacement Cartridge
(Model #8013630 or #8014644)
(6)
When You Travel Abroad, Camp or
Backpack…
…you run a risk of illness ranging from the inconvenience and discomfort of diarrhea to
moreserious illnesses caused by protozoan cysts (i.e., Giardia, Cryptosporidium), viruses
and bacteria.
The microorganisms that cause these diseases are often found in the food and water you
consume. Lakes, streams and the local water supply may be contaminated.
To minimize the risk of contracting these illnesses, we suggest that you consult with your
physician, state health department or travelers’ clinic 4-6 weeks before you depart.
And while you are traveling…
• Make sure that prepared food is thoroughly cooked.
• Select non-cooked foods (fruits, nuts, etc.) that have intact shells or skins,
and clean your hands before peeling the food.
• Wash your hands with soap and water thoroughly and often, especially
before you eat. Filter all drinking water with your Katadyn Hiker Water Microfilter.
The Katadyn Hiker Microfilter is an essential piece of outdoor equipment. We hope it makes
your outdoor experience more enjoyable. For questions or suggestions, please contact us at
1-800-755-6701.
(5)
Long-Term Storage (After Your Trip Is Over)
Disinfect your microfilter before storage to prevent microbiological growth within the pump.
1) Fill a liter container with tap water and add 2 tablets of Micropur Forte (if not
available use 2 tablespoons of ordinary household bleach).
2) Place prefilter into solution.
3) Pump entire amount of solution through unit (into sink or container).
4) Remove prefilter from the solution and continue pumping another 5 to 10 strokes to
remove remaining water from the pump body and hoses.
5) Remove cartridge and allow to dry.
6) Wrap hoses around body and store in carry bag.
Note: When removing unit from long-term storage, flush the system with one liter of water
to remove any stale tasting water.
Cartridge Capacity
Cartridge capacity depends on water quality. The Katadyn Hiker was tested at 750 liters
and found effective for removal of bacteria (Klebsiella terrigena) and protozoan cysts
(Giardia and Cryptosporidium). For maximum performance, cartridge should be replaced
after 750 liters or when the unit becomes hard to pump.
Cartridge Installation
Replacement cartridges are available from the dealer where you purchased your Katadyn
Hiker.
1) Remove output hose from cartridge output barb. Grasp the top of the Hiker cartridge
and turn counter clockwise. If cartridge removal is not possible by hand, the handle
shaft will function as a cartridge removal tool: Remove the handle collar and handle.
Locate one of the deep grooves on either side of the handle shaft. Lay the handle across
the filter top and insert two of the “fins” on top of the filter into one of the groves of the
handle shaft. Hold the handle shaft in place firmly with the palm of your hand. Using
the handle shaft for leverage, apply even pressure and gradually turn the cartridge
counter clockwise. Use caution so that handle shaft does not slip and cause damage.
Discard used cartridge in trash receptacle.
2) Rinse inside of Hiker housing by swishing with clear water (non-filtered water is ok).
Discard water. Wipe inside of housing and housing threads with soft cloth to remove
sediment.
3) Remove new cartridge from packaging.
4) Insert new cartridge into housing and tighten clockwise. Note - Apply silicone lubricant
to cartridge o-ring before re-assembly to ease cartridge removal in the future.
5) Re-attach output hose to cartridge output barb. (Figure 1-1)
6) Flush cartridge by pumping and discarding the first liter.
Limited Warranty
Your Katadyn Hiker Microfilter is warranted for one (1) year from the date of purchase
against defects in materials and workmanship. Should your Katadyn Hiker prove defective
within one year from the date of purchase, return it to the Katadyn retailer from whom it
was purchased. If you do not receive a satisfactory resolution, contact Katadyn Consumer
Relations at 1-800-755-6701 for service assistance. Katadyn, at its discretion, will replace
or repair the damaged item. Please retain your purchase receipt as proof of date purchased.
This warranty gives you specific legal rights and you may have other legal rights which vary
from state to state.
Contact North America:
Katadyn North America Inc.
6325 Sandburg Road
Minneapolis, MN 55427 / USA
1-800-755-6701
[email protected] / www.katadyn.com
Contact International:
Katadyn Products Inc.
Birkenweg 4
8304 Wallisellen / Switzerland
[email protected] / www.katadyn.ch
Print No. 8013798/4
Product Registration
Please take a moment to register your new Katadyn product by completing the short product
registration form online at www.katadyn.com/productregistration. The information you
provide will enable us to better serve you with products developed to meet your needs and
interests. Register your Katadyn product online and you will be automatically entered into a
drawing to win a free Katadyn product.
071374-Katadyn-8013798 25-04-2007 18:42 Pagina 1
(1)
Thank you for choosing a Katadyn portable water microfiltration system.
The Katadyn Hiker Microfilter meets industry standards for reduction of
bacteria (99.9999% Klebsiella terrigena) and protozoan cysts (99.9%
Giardia and Cryptosporidium). Its compact and lightweight design is easy
to use and essential equipment for camping, backpacking and trekking.
(2)
Key Components
Prefilter
The modular prefilter (Figure 1-2) is effective in still and running water. It
consists of two components: a strainer and a weight.
Note: Apply a small amount of silicone lubricant to the strainer barb to ease
assembly.
The prefilter is important because it prevents large particles (larger than
130 microns) from entering the water system. See Field Performance Tips for
helpful hints.
EasyFill™ Bottle Adaptor
The EasyFill Bottle Adaptor (Figure 2-1) conveniently attaches directly to
different sized watercontainers.
Hydration Bladder Compatible
Your Katadyn Hiker includes a connector (1) that allows the output hose to
attach to the quick connect fitting built-in to many hydration bladders such as
Nalgene, Jansport, etc. This convenient feature allows easy filling of hydration
bladders. See illustration (Figure 2-2) for installation.
(3)
Product Set-up
The Hiker requires minimal set up. For best results, try out the Hiker before first field use to
familiarize yourself with its operation.
1) Connect Hoses
Remove the plastic caps from the input and output barbs; retain for storage. Connect
input hose (hose with prefilter) to input barb at base of pump housing. Connect output
hose tooutput barb on top of cartridge. Connect the EasyFill Bottle Adaptor to the end
of theoutput hose. (Figures 1-1, 1-2, 2-1) For use with hydration bladder, connect
hydrationconnector to the end of the output hose. (Figure 2-2)
2) Flush System
Important: Before first use, flush system by pumping approximately 1 liter of water
through the unit to remove harmless carbon dust. Slightly discolored water is normal
when flushing. See following section on Normal Operation on how to filter water.
Normal Operation
1) Place input hose in untreated water source. Adjust the float to keep prefilter off the
bottom and away from sediment.
2) Insert the EasyFill Bottle Adaptor into a clean water container or connect hydration
connector to bladder*. (Figure 2-1, 2-2)
3) Make sure the hoses are not kinked. Begin pumping the handle in a slow, steady
manner. Approximately 48 strokes per minute equals 1 liter of water.
4) After filling water container with filtered water, remove bottle adaptor/hydration
connector from container/bladder and prefilter from water source. Continue pumping
to remove remaining water from pump body.
5) Store unit in the carry bag. To prevent the possibility of cross contamination, remove
the output hose and EasyFill Bottle Adaptor and store separately in the re-sealable
bag inside the carry bag.
*Note: Before each use, flush and discard a small amount (5 – 10 strokes) of water to
remove stale taste.
(4)
Field Performance Tips
The Katadyn Hiker is designed to remove bacteria and protozoan cysts
such as Giardia and Cryptosporidium. To extend cartridge life, always
use the best water source available. Keep the intake prefilter clean and off the
bottom. In heavy
sediment conditions, wrap a coffee filter or bandanna around the intake prefilter. Where
possible, place untreated water in container and wait for sediment to settle out until water
appears clear - then filter from water above the sediment.
Maintain your Katadyn water system to keep it operating smoothly.
1) If handle is hard to push:
Lubricate pump handle o-ring. Silicone lubricant is provided with your new
unit. Remove handle collar and handle. (Figure 1-1) Clean excess build-up from
black rubbero-ring on bottom of handle. Place a small amount of silicone lubricant all
the way around the o-ring. Re-assemble.
Clogged cartridge. A clogged cartridge requires replacement. As a temporary
solution in the field, remove the cartridge and swish it around in water. See Cartridge
Installation for cartridge removal. Take care that untreated water does not contact
the cartridge output barb. If flow is not restored, replace cartridge.
2) If unit pumps easily, but no water flow:
Make sure prefilter is submerged.
Make sure that hoses are not blocked or pinched.
Clean check valve. Occasionally, sediment may enter pump body and prevent
check valve from operating properly. This may cause lack of water draw. The check
valve caneasily be cleaned to restore maximum water output. Remove the cartridge.
Fill the pump housing half way with water, swirl around and discard water. Fill the
housing half way with water again and reinstall cartridge. Pump slowly to get water
started and resume normal pump rate when flow has begun.
3) Prefilter: Rinse the prefilter in water to remove any particles that may be caught in
the strainer. For a more thorough cleaning, remove the prefilter from the input hose
and clean with water and a soft brush. Reassemble. Apply a small amount of silicone
lubricant to the strainer barb to ease assembly. (Figure 1-2)
For use without the weight. The prefilter is functional with or without the weight
(we recommend using with the weight). To use without the weight, remove the strainer
barb from the input hose. Re-assemble without the weight.
4) Storage: Your Katadyn water system comes with a carry bag for storage. To prevent
the possibility of cross contamination, remove the output hose and EasyFill Bottle
Adaptor and store separately in a re-sealable bag inside the carry bag.
(Figure 1-1)
Output Hose
Bottle
Adaptor
(Figure 2-1)
Output Barb
Cartridge
Housing
Check Valve
(inside housing)
Handle Collar
Input Barb (with
built-in pressure
relief valve)
Pump Handle
O-Ring
Handle
(Figure 1-2)
Weight
Strainer
Input Hose
C P C
(1)
(Figure 2-2)
Strainer
Barb
071374-Katadyn-8013798 25-04-2007 18:42 Pagina 2

Other manuals for 8013629

1

This manual suits for next models

7

Other Katadyn Water Filtration System manuals

Katadyn MyBottle User manual

Katadyn

Katadyn MyBottle User manual

Katadyn Exstream User manual

Katadyn

Katadyn Exstream User manual

Katadyn HFD-PS40 User manual

Katadyn

Katadyn HFD-PS40 User manual

Katadyn Combi Plus Water Microfilter User manual

Katadyn

Katadyn Combi Plus Water Microfilter User manual

Katadyn 1120070 User manual

Katadyn

Katadyn 1120070 User manual

Katadyn VARIO Assembly instructions

Katadyn

Katadyn VARIO Assembly instructions

Katadyn Rapidyn Operator's manual

Katadyn

Katadyn Rapidyn Operator's manual

Katadyn 8014931 User manual

Katadyn

Katadyn 8014931 User manual

Katadyn Survivor 06 User manual

Katadyn

Katadyn Survivor 06 User manual

Katadyn MyBottle User manual

Katadyn

Katadyn MyBottle User manual

Katadyn Exstream Personal Water Purification System User manual

Katadyn

Katadyn Exstream Personal Water Purification System User manual

Katadyn Camp User manual

Katadyn

Katadyn Camp User manual

Katadyn Rapidyn Operator's manual

Katadyn

Katadyn Rapidyn Operator's manual

Katadyn Steripen Classic 3 User manual

Katadyn

Katadyn Steripen Classic 3 User manual

Katadyn Gravity Camp 6L 8019297 User manual

Katadyn

Katadyn Gravity Camp 6L 8019297 User manual

Katadyn 8013631 User manual

Katadyn

Katadyn 8013631 User manual

Katadyn Combi 8013620 User manual

Katadyn

Katadyn Combi 8013620 User manual

Katadyn Base Camp Water Microfilter User manual

Katadyn

Katadyn Base Camp Water Microfilter User manual

Katadyn 8018280 Hiker Pro User manual

Katadyn

Katadyn 8018280 Hiker Pro User manual

Katadyn 8014932 User manual

Katadyn

Katadyn 8014932 User manual

Katadyn PowerSurvivor 40E User manual

Katadyn

Katadyn PowerSurvivor 40E User manual

Katadyn Steripen UltraLight User manual

Katadyn

Katadyn Steripen UltraLight User manual

Katadyn Survivor 35 User manual

Katadyn

Katadyn Survivor 35 User manual

Katadyn 2040000 User manual

Katadyn

Katadyn 2040000 User manual

Popular Water Filtration System manuals by other brands

Linear Technology LT6604 Series quick start guide

Linear Technology

Linear Technology LT6604 Series quick start guide

EGT EGT-200 user manual

EGT

EGT EGT-200 user manual

AquaCo SYS-ROCOMP manual

AquaCo

AquaCo SYS-ROCOMP manual

AWS 50-AWS manual

AWS

AWS 50-AWS manual

ENEKA Greasly-A Installation, operation and maintenance manual

ENEKA

ENEKA Greasly-A Installation, operation and maintenance manual

Aquapure AP1610SS quick start guide

Aquapure

Aquapure AP1610SS quick start guide

Excalibur Water Systems SMART PURIFIER BP-500G manual

Excalibur Water Systems

Excalibur Water Systems SMART PURIFIER BP-500G manual

Atlas Filtri DOSAPROP quick start guide

Atlas Filtri

Atlas Filtri DOSAPROP quick start guide

AquaCare ADN400-a instruction manual

AquaCare

AquaCare ADN400-a instruction manual

Culligan IC-1000 Installation and operating instructions

Culligan

Culligan IC-1000 Installation and operating instructions

Trion AIR BOSS owner's manual

Trion

Trion AIR BOSS owner's manual

3M Aqua-Pure AP717 Installation and operating instructions

3M

3M Aqua-Pure AP717 Installation and operating instructions

Schaffner ECOsine active FN3420-030-3 Series Operating and installation instructions

Schaffner

Schaffner ECOsine active FN3420-030-3 Series Operating and installation instructions

BIOLAN GREYWATER FILTER 125 Instructions for installation, use and maintenance

BIOLAN

BIOLAN GREYWATER FILTER 125 Instructions for installation, use and maintenance

Levoit LV110WP-3X user manual

Levoit

Levoit LV110WP-3X user manual

Hilti DD-REC 1 operating instructions

Hilti

Hilti DD-REC 1 operating instructions

norweco BIO-DYNAMIC LF 1000 Installation and operation manual

norweco

norweco BIO-DYNAMIC LF 1000 Installation and operation manual

TEFAL WV207C30 manual

TEFAL

TEFAL WV207C30 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.