Kohler Co. 7 1082081-X2-A
10.Tightenpanelwithushvalvewith4pcsoflongscrews.
a.Putoncleanglovesduringinstallationtoavoidsurface
damage.
b.Donotfacethesidewithlettersinwardsorinstallin
areverseway.
USER’S GUIDE
NOTICE: Therst10minuteswithpoweristhestandbytimeforadjustingsensingdistance.Personsorsubjects
shouldavoidstandingbeforethesensor.Thesensorwillnotushduringthistime.
Eco-friendly ush mode:Whentheurinalisnotusedforalongterm,itissettoushwithlargevolume
ofwaterautomaticallyevery24hours.
Set Working Status: Theproductcomesourfactorywith:
1.Theworkingstatusissetasdual-ush.Ifyouwanttocanceltherstushingfunction,placemanualush
stickadjacenttorightsideofsensingwindowformorethan1secondduringthe10-minutestandbyperiod
(humanpresenceinsensingrangewouldcausetheindicatortoashfast).Thesensorwouldgeneratea
ushingcycletoindicatethesetupofthesensorhasbeenadjustedtoafter-useushing.Iftheactionisnot
completedduringthis10minute,oryouneedtorestoretheworkingstatustodual-ush,plugoffthepower
cordandreconnectthepowersupplyuntiltheindicatorstopsashingandrepeattheaboveprocedures.
2.Thedictiontimeissetas2stoavoidimproperfunctioninnarrowtoilets,thedetectiontimeisautomaticallyset
from2sto5s.
Working Status:Beforepoweringthesystemon,cleartheunwantedobjectsinfrontofthesensorwindow
lestshorteningthesensingdistance.
Sensing Distance: Duringtherst10minutes,whenpoweredon,thesystemisinthephaseofautomatic
regulation,andnooperationisrequired.
Deodorizing Flushing: Theurinalwilltakeaushautomaticallywhenit’sused3or4timesin2minutes.
Adjusting Screw
Hex Wrench
Flushing Volume:Ifyouneedtoregulatetheushing
volume,youcantakeoffthecoverandturntheadjusting
screwinthecenterofthestopvalvetoaproperplace.
Manual Flushing: Approachthesuppliedspecial
magneticstick(flushingcontrolstick)tothemiddlepart
ofthesensorlens.Thesystemisnowatmanualstatusand
theindicatorwillflashevery1seconds.Approachthe
flushingcontrolsticktothewindow,it’llstarttoflush;
approachagain,stoppingflushing.Thisstatuswilllast
for8minutesuntilitturnstothenormalworkingstatus.
(Theushing,ifany,willbeterminatedwhenthisstatusends).
NOTICE:Thelongestusingtimeis30secondsonce.Ifthe
flushingcontrolstickkeepsneartothesensingwindow,
themanualstatuswillbeterminatedautomaticallyand
reassumethenormalworkingstatus.