3-1
3-2
Display range 0~20 000 RPM:,
Display unit 100 RPM:
Display unit 0.1 HOUR:
●Tachometer
○Max. RPM record
○Display internal
Display range: 0~20 000 RPM:,
Display unit 1 RPM:
Display range 99 999 (HOUR), resets:,
automatically after 99 999 (HOUR),
automatically after 9999.9 (HOUR)
Display unit 1 HOUR:
○Total hour meter
○Warning
○RPM input pulse Setting range 0.5 1~6:,
<0.5 second
5 000~20 000 RPMSetting range:, ,
●Thermometer
○Thermometer
Display unit:°C & °F for alternative
Display range 0~250 °C (32~482 °F):
Display unit 0.1 °C (°F):
Setting unit:100 RPM
○Hour meter A / B Display range: 9999.9 (HOUR), resets:
Thermometer
Display range 0~250 °C(32~482 °F)
Display range 0.1 °C (°F)
● :
● :
Tachometer
Display range 20,000 RPM
Display range 100 RPM
● :
● :
●Select button
●Adjust button
Function, setting instruction
Basic function instruction
MAX RPM / Temperature record
The meter will record the top RPM
and temperature automatically.
●
3-3
●Hold pressing the Adjust button for 3
seconds to reset the hour meter A.
Function switch instruction
●In RPM screen, Press the Select button
once to switch function from to
.
RPM
total hour meter
●In screen, Press the Select
button once to switch function from
to .
total hour
total
hour hour meter A
●In screen, Press the Select
button once to switch function from
to .
hour meter A
hour
meter A hour meter B
●Hold the Adjust button for 3
seconds to change the temperature unit
●In thermometer screen, Press the Select
button once to switch function from
current temperature to MAX temperature
recorded.
●In RPM screen, Hold the
Select button for 3 seconds to switch
function from RPM to thermometer.
●Hold the Adjust button for 3
seconds to reset the MAX temperature
recorded.
● 。In RPM screen
●In MAX temperature recorded screen,
Hold pressing the Select button for 3
seconds to go back to the RPM screen.
●
the RPM screen.
Select button one time to go back to
Max. RPM record screen, Press the
●In RPM screen.
●Hold pressing the Adjust button for 3
seconds to reset the hour meter B.
●Hold pressing the Adjust button for 3
seconds to reset the MAX.
●In screen, Press the
Select button once to switch function
from to MAX.
hour meter B
hour meter B
Setting range 60~250 °C (140~482 °F):
Setting unit 0.1 °C (°F):
-10~+60 °C
JIS D 0203 S2
Display range 0~250 °C (32~482 °F):
Setting range 1-5 (Darkest)~5-5 (Brightest):
CR 2032
○Thermometer alarm
●Backlight brightness
●Effective voltage
Meter weight●
●Meter size
●Meter standard
●Effective temperature range
○MAX temperature record
Setting unit Each level represents 20%:
Design and specification are subject to change without notice.
NOTE
90 X 33.5 X 15 mm
± 330g
●Press the Select button one time to enter
the shift light setting.
●
●
EX. You want to change the current setting
value from 1 to 2.
Press the Adjust button to enter the
corresponding value for the RPM signal
number per ignition. (Check the
reference table below)
4
4-1
●
●
Press the Select button to go back to
the RPM pulse setting.
EX. The pulse setting is
changed from 1 to 2 (4C-4P).
4-2
Function setting instruction
●In main screen, hold the Select
+ Adjust button for 3 seconds to enter the
setting screen.
RPM pulse setting
●Press the button one time to
enter the RPM pulse setting.
Select
Default:P-1
註
NOTE
註
NOTE
註
NOTE
Now the d is flashingefault
The piston type can be set is 0.5,1,
2,3,4,5,6.
Some 4 stroke engine with single cylinder also
generate 1 ignition signal per revolution of the
engine. In this case the setting should be set as
same as 2 stroke engine with single cylinder
type of bike.
CAUTION!
Value is how many ignition signals the
engine will generate per revolution (360 )
o
The corresponding RPM signal
number per ignition.
2C-1P 4C-2P
4C-4P2C-2P
0.5
2
4C-6P2C-3P3
4C-8P2C-4P4
4C-10P
5
4C-12P2C-6P6
1
4C-1P
The corresponding
stroke and pistons number.
The setting
value
1 RPM signal 1 ignition.per
2 RPM signal 1 ignition.per
1 RPM signal 2 ignition.per
1 RPM signal 3 ignition.per
1 RPM signal 4 ignition.per
1 RPM signal 5 ignition.per
1 RPM signal 6 ignition.per
●
●
EX: You want the shift light to illuminate
at 8000 RPM change the shift
light setting value to 8500 directly.
Press the Select button to move to the
digit you want to set.
Setting
Setting
range 5,000~20,000 RPM
unit 100 RPM
:
:
Default:8,000RPM
註
NOTE
註
NOTE
Now the d is flashingefault
●Press the Adjust button to choose the
setting number.
●
●
Press the Select button to choose the
Shift light setting.
EX: Now the shift light setting is
changed from 8,000RPM to 8,500
RPM.
●Press the Adjust button to enter the shift
light setting.
The shift light setting
Setting 6
range:
0 ~ 250 °C
(140~482 °F)
Default:90 °C
註
NOTE
註
NOTE
Now the d is flashingefault
●Press the Adjust button to enter the
t setting.
emperature alarm
4-3
●Press the button one time to
enter the t
Select
emperature alarm
setting.
●
●
EX: You want to set the temperature
alarm at 95 °C.
Press the Select button to move to
the digit you want to set.
●Press the Adjust button to choose the
setting number.
●
●
Press the Select button to go back to
the temperature alarm screen.
EX: The temperature alarm setting is
changed from 90°C to 95 °C.
Temperature alarm setting
90 mm 15 mm
33.5 mm
wh054ba00a(P3-2)
●Select button function instruction
●Select button for 3 seconds function instruction