Safety instructions
This product should be installed preferably by aqualified electrician.
Incorrect installation and use can entail risk of electric shock or fire.Before carrying out the installation,
read the instructions and take account of the product’s specific mounting location.Donot open up the
device.
All Legrand products must be exclusively opened and repaired by personnel trained and approved by
LEGRAND. Any unauthorised opening or repair completely cancels all liabilities and the rights to
replacement and guarantees.Only use genuine accessories.
Figure 2
B "Second Fix" Steps:
NOTE: Make sure that the Power Supply is not connected to the Distribution Module.
-Install the Four Source, Eight Zone Distribution Module in an enclosure using the included plate's tabs
and push pins.
-Terminate all Category 5ecables with RJ-45 plugs using the T568A wiring standard.
-Connect the Single Source Input and Triple Source Input AUDIO OUT jacks via aCategory 5ejumper,
to wall jacks with RJ-45 inserts.These jacks in turn should be wired to the SOURCE IN jacks of the
Four Source, Eight Zone Distribution Module (see Figure 2).
-Connect the Category 5 cables coming from the room locations containing the Keypad Volume
Controls to the Zone Output jacks on the Four Source, Eight Zone Distribution Module (see Figure 2).
-If applicable, expand the system by connecting one or more Single Source, Four Zone Distribution
Modules to the Zone Out jacks on the Four Source, Eight Zone Distribution Module.
-Plug one or two 24 Volt power supply cables into the Power jacks on the Distribution Module
(depending on Zone usage).
-Verify system functionality.
Optional components and Cat 5e wiring to control four audio devices