FEATURES
• Multiplemountingoptions–surfacemount(withthreadednippleorkeyholes),orrecessedmount
• Quick-snapnippleallowsforinstallationintostandardDoubleDKnockoutonLuminairewithoutrequiringalocknut
• 20ft.x60ft.aislepatternat40ftmountingheight
• 360°eld-of-viewfor20ft.to40ft.HighBaymountingheights
• 360°eld-of-viewfor8ft.to25ft.LowBaymountingheights
• Interchangeable360°HighBay,LowBayandaislelensincluded
• AdjustableTimeDelaydoesnotrequirepowertoset
• LEDindicatorlightblinkswhensensordetectsmotion
• AdjustablerotatinglensforoptimizingsensordetectionpointswithintheFOVforthespecicroom
• Falsedetectioncircuitryreducesnuisancetrippingforenergysavings
• Duringapoweroutage,return-to-last-statedesign,assureslightsONforsafetywhenoccupiedandlightsOFFforenergy
savingswhenunoccupied
• H.I.S.-LevitonHighInrushStabilityusesarobustmechanicallatchingrelayandzerocrossingforlonglife
• Instantstartuppowersluminaireunder3secondstospeeduptestingonxtureassemblyline
• 42"pre-strippedcolorcodedwireleads
• Optionalpeelandstickmaskkit
DESCRIPTION
Leviton'ssurfacemounthighbayopccupancysensor,OSFHS-IxW,isspecicallydesignedforhighmountedareassuchas
warehouses,manufacturingandotherhighceilingapplications.Ithastheexibilitytobesurfacemounteddirectlytothefrontof
axtureorrecessmountedinternaltothexture.Itisaself-containedsensorandrelaythatdetectsmotionusingthepassive
infrared(PIR)tosensesources(suchasapersonenteringaroom)withinitseld-of-view(monitoredspace)andautomatically
switcheslightsON.ThecontrolledlightswillremainONuntilnomotionisdetectedandthescheduledtime-delayhasexpired.
Thesensorissuppliedwiththreeinterchangeablelensringsthatallowstheusertoselectbetweena360degreeHighBay/Low
Baypatternoranaislepattern.
Cat.No.OSFHS-IxWisULlisted,cULlistedandconformstoCaliforniaTitle24requirements.TheSensor'sHighBaylensand
aislelensisdesignedfor20ft.to40ft.mountingheightsforasymmetricalpatternwhichwillprovidecoverageof50'to60'
diameter(refer to Figure 4 and 5).TheLowBaylensisdesignedfor8ft.to20ft.mountingheightsforasymmetricalpattern
whichwillprovidecoverageof30'to50'diameter(refer to Figure 6).TheSensorissensitivetotheheatemittedbythehuman
body.InordertoinitiallytriggertheSensor,thesourceofheatmustmovefromonezoneofdetectiontoanother.
Notethatoccupancysensorsrespondtorapidchangesintemperature,socareshouldbetakennottomountthedevicenear
aclimatecontrolsource(i.e.radiators,airexchanges,andairconditioners).Hotorcolddraftswilllooklikebodymotiontothe
deviceandwilltriggeritiftheunitismountedtooclose.It is recommended to mount the Occupancy Sensor at least 6 ft.
away from the heating or cooling ventilation source.
INSTALLATION INSTRUCTIONS
WARNING:TOBEINSTALLEDAND/ORUSEDINACCORDANCEWITHAPPROPRIATEELECTRICALCODESAND
REGULATIONS.
WARNING:IFYOUARENOTSUREABOUTANYPARTOFTHESEINSTRUCTIONS,CONSULTANELECTRICIAN.
WARNING:CONTROLLINGALOADINEXCESSOFTHESPECIFIEDRATINGSWILLDAMAGETHEUNITANDPOSE
RISKOFFIRE,ELECTRICSHOCK,PERSONALINJURYORDEATH.CHECKYOURLOADRATINGSTODETERMINETHE
UNIT’SSUITABILITYFORYOURAPPLICATION.
OTHER CAUTIONS AND NOTES:
1. DISCONNECTPOWERWHENSERVICINGLUMINAIREORCHANGINGBULBS.
2.USETHISDEVICEWITHCOPPER OR COPPER CLAD WIRE ONLY.
3.DONOTATTEMPTTODISASSEMBLEORREPAIR.CLEANOUTERSURFACEWITHADAMPCLOTHONLY.
TO INSTALL:
NOTE:TheOSFHS-IxWissuppliedwiththreelenstrimrings.The360degreeHighBaylens(whitecolortrimring)isinstalledat
thefactorywiththeaislelens(blackcolortrimring)andthe360degreeLowBaylens(bluecolortrimring)inthecarton.Change
thelensforuseinaisleorLowBayapplications.Seebelowforchanginglenstrimring.TheOSFHS-IxWcanbemountedto
thesurfaceofaxtureusingthe1/2"threadednippleorusingthekeyholeslotsonthebackofthesensor.Itcanalsoberecess
mountedinternaltothextureusingtheslotsonthesideofthesensor.Referencefigures 1, 2 and 3fordimensionsand
mountingspecications.
SENSOR INSTALLATION:
1.WARNING:TOAVOIDFIRE,SHOCK,ORDEATH:TURN OFF POWERATCIRCUITBREAKERORFUSEANDTEST
THATTHEPOWERISOFFBEFOREWIRING.
2. Thesensorcomeswiththreelensrings.NOTE:Anoptionalpeelandstickmaskingkitisincluded.Thiscircularadhesivelabel
(withremovablewedges)isappliedtotheOUTSIDEofthesensorlens.Useanynumberofwedgestoaltereld-of-viewfor
yourdesiredapplication.
3.Tochangelens,turntrimringsothatthetwoindenteddotslineupandpulloutbythengertabs(refer to Figure 7).
4.Toinserttheblackaislelens,lineuptheindenteddotsandindentedtabsonundersideoflensandinsertintokeyopenings
andturnclockwise(refer to Figure 8).
5.Linethengertabswiththedirectionoftheaisle.Thelenswillsnapintoindentationbumpstoindicatethelensdirectionisat
either90degreeor0degreeorientation.
DI-000-OSFHS-05A
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not
forthebenetofanyoneelsethatthisproductatthetimeofits
salebyLevitonisfreeofdefectsinmaterialsandworkmanship
under normal and proper use for ve years from the purchase
date.Leviton’sonlyobligationistocorrectsuchdefectsbyrepair
orreplacement,atits option, ifwithinsuchveyearperiodthe
product is returned prepaid, with proof of purchase date, and
a description of the problem to Leviton Manufacturing Co.,
Inc., Att: Quality Assurance Department, 201 North Service
Road, Melville, N.Y. 11747. This warranty excludes and there
is disclaimed liability for labor for removal of this product or
reinstallation. This warranty is void if this product is installed
improperlyorinanimproperenvironment,overloaded,misused,
opened,abused,oralteredinanymanner,orisnotusedunder
normaloperatingconditionsornotinaccordancewithanylabels
orinstructions.There are no other or implied warranties of any
kind, including merchantability and fitness for a particular
purpose,butifanyimpliedwarrantyisrequiredbytheapplicable
jurisdiction,thedurationofanysuchimpliedwarranty,including
merchantabilityandtnessforaparticularpurpose,islimitedto
veyears.Leviton is not liable for incidental, indirect, special,
or consequential damages, including without limitation,
damage to, or loss of use of, any equipment, lost sales or
profits or delay or failure to perform this warranty obligation.
Theremediesprovidedhereinaretheexclusiveremediesunder
this warranty, whether based on contract, tort or otherwise.
For Technical Assistance Call:
1-800-824-3005 (U.S.A. Only)
www.leviton.com
DI-000-OSFHS-05A
Triple Mount
High Bay Occupancy Sensor
Cat.No.OSFHS-IxW(Sensor)
Ratings:
800VA-6.67A@120VAC,1/4HP,50-60Hz
1200VA-4.33A@277VAC,50-60Hz
1500VA-4.32A@347VAC,50-60Hz
32oFto160oF
Compatiblewithelectronicandmagneticballasts,
electronicandmagneticlow-voltageballasts
INSTALLATION INSTRUCTIONS
Surface Mount Installation:
a.Removethelock-nutfromthethreadednippleandinsertthewiresandthethreadednippleintoahalfinchholeofthe
luminairebody.
b.Slidethelock-nutoverthewiresandthreadclockwiseontothethreadednippletosecurermlyinplace,makingsure
thelensisorientedtowardstheareatobemonitored(refer to Figure 1).
Keyhole Mount Installation:
a.Removethethreadednipplefromthebackofthesensorbyturningcounterclockwise.
b.UsingthespecicationsinFigure 2asaguide,placethesensorandkeyholeslotsoverthescrews(use#8-32pan
headscrews)andturnclockwisetolockintoplace,makingsurethelensisorientedtowardstheareatomemonitored.
Recessed Mount Installation:
a.UsingthespecicationsinFigure 3asaguide,cutaholeperdimensionsspeciedintotheluminaire.
b.Slidethesensorintotheholeuntiltheclipsonthesideofthesensorsnapintoplace,securingthesensor.
6.ConnectwiresperWiring Diagramasfollows:BLACKleadtoLINE(Hot);REDleadtoLOAD;WHITEleadtoLINE(Neutral).
Twiststrandsofeachleadtightlyand,withcircuitconductors,pushrmlyintotheappropriatewireconnector.Screw
connectoronclockwisemakingsurethatnobarewireshowsbelowtheconnector.
7.Restorepoweratcircuitbreakerorfuse.
NOTE:Allowapproximately1minuteforcharge-up.IfthelightsturnONandtheLEDblinkswhenahandiswavedinfrontofthe
lens,thentheSensorwasinstalledproperly.Iftheoperationisdifferent,refertotheTroubleshootingSection.
TheSensorisfactorypresettoworkwithoutanyadjustments.Ifyoudesiretochangethefactorysettings,refertotheSETTINGS
section.
SETTINGS
NOTE:Settingsshouldbedeterminedduringtheinstallationperiod.Removethelensto
accesstheTimeDelayandSensitivitydials.
Time-Delay:ThisadjustmentcontrolstheamountoftimethelightsstayONafterthelast
detectedmotion.Youmayselectsettingsvaryingfrom30secondsto30minutesandany
timeinbetween,nopowerrequired.
Sensitivity:Turndialclockwisetoincreasedetectiontosmallmovements.Turndial
counter-clockwisetodecreasedetectiontosmallmovement.
NOTE:AfterpoweristurnedON,allowoneminutefortheunittowarmupbeforeitwillperformthesettings.
TROUBLESHOOTING
• Lights will not turn ON
- Site or application interference: VerifyLEDisashingandcheckformanualoverrideswitchesorobstaclesblocking
PIRandFOV.
- Circuit breaker or fuse is OFF:TurnthebreakerON.Ensurethelightsbeingcontrolledareinworkingorder
(i.e.,workingbulbs,ballasts,etc.)
- Sensor is wired incorrectly or may be defective:Conrmthatthesensor’swiringisdonecorrectlyandinspect
visuallyforproblems.
- Lens is dirty or obstructed:Inspectthelensvisuallyandcleanifnecessary,orremovetheobstruction.
• Lights will not turn OFF
- Site or application interference: checkformovingxture,movingparts/items/deviceswithintheFOV.
- Sensor is wired incorrectly or may be defective:Conrmthatthesensor’swiringisdonecorrectlyandinspect
visuallyforproblems.
- Sensor may be mounted too closely to an air conditioning or heating vent:Movethesensororclosethevent.
- The line voltage has dropped:Performthenecessaryteststoensurethelinevoltagehasnotdroppedbeneath100V.
• Lights turn OFF and ON too quickly
- Sensor may be mounted too closely to an air conditioning or heating vent:Movethesensortoanotherlocation
orclosethevent.
- Time delay set improperly:AdjusttheTIMEDELAY.
• Lights shut OFF while occupied (False OFF)
- IncreaseTIMEDELAY.
• Lamps are being replaced too often
- 10minutesisoptimalforlamplifeandenergysavings.IncreaseTIMEDELAYtogreaterthan10minutes.
Wiring Diagram Hot (Black)
Neutral (White)
Load
Red
White
White
Sensor
Black
Black
Line
120-277-347 VAC,
50/60 Hz
S
E
N
S
I
T
I
V
I
T
Y
T
I
M
E
30
SEC
10
20
30
MIN
Top View
21 cm
85.3 cm
Steel/18AWG
92.5 cm
1.2 cm
9.1m
(30 ft)
9.1m
(30 ft)
6.1m
(20 ft)
6.1m
(20 ft)
3.0m
(10 ft)
3.0m
(10 ft)
0
High Bay
360o
Top View
Surface Mount Keyhole Mount Recessed Mount
Side View
9.1m
(30 ft)
9.1m
(30 ft)
9.1m
(30 ft)
12.2m
(40 ft)6.1m
(20 ft)
6.1m
(20 ft)
6.1m
(20 ft)
3.0m
(10 ft)
3.0m
(10 ft)
0
0
Dots
Line up dots Pull up on tab to remove 360° lens
(High Bay or Low Bay)
Tab
Insert aisle lens
with dots lined up
Turn clockwise to set aisle direction
1
2
63.5 cm
(±0.1 cm)
#8-32 pan head screws
2.8 cm (±0.2 cm)
Figure 1 Figure 2 Figure 3
Figure 4 Figure 6Figure 5
Low Bay
360o
9.1m
(30 ft)
9.1m
(30 ft)
6.1m
(20 ft)
6.1m
(20 ft)
3.0m
(10 ft)
3.0m
(10 ft)
0
Top View Side View
9.1m
(30 ft)
9.1m
(30 ft)
6.1m
(20 ft)
7.6m
(25 ft)
6.1m
(20 ft)
6.1m
(20 ft)
2.4m
(8 ft)
3.0m
(10 ft)
3.0m
(10 ft)
0
0
Figure 7 Figure 8
9.1m
(30 ft)
9.1m
(30 ft)
6.1m
(20 ft)
6.1m
(20 ft)
3m
(10 ft)
3m
(10 ft)
0
Aisle
Top View Side View
9.1m
(30 ft)
9.1m
(30 ft)
9.1m
(30 ft)
12.2m
(40 ft)6.1m
(20 ft)
6.1m
(20 ft)
6.1m
(20 ft)
3m
(10 ft)
3m
(10 ft)
0
0
S
H
E
L
V
E
S
S
H
E
L
V
E
S
DI-000-OSFHS-05A
©2012LevitonMfg.Co.,Inc.
ARTWORK PRINT SPECIFICATIONS
FOLD SCHEME / BINDERY DIAGRAM
PART NUMBER REV DESCRIPTION
Line Screen:
Angle:
Resolution:
Offset Flexo
Other
Body Material:
Bindery
Thickness:
Trim
Perfect Bind
Die cut Saddle Stitch
Drill
Fold
The information in this document is the exclusive PROPRIETARY property of LEVITON MANUFACTURING COMPANY, INC. It is disclosed
with the understanding that acceptance or review by the recipient constitues an undertaking by the recipient. (1) to hold this information in strict
confidence, and (2) not to disclose, duplicate, copy, modify or use the information for any purpose other than that for which disclosed.
PlantApprovals:
PN-ARN: Pilot Rev:ECO Number:
Artwork Release Date:
Artwork Print Specification Sheet Rev A08.eps
PMCQA
Artist:
Notes:
Other
Cust Other
S & A
Mktg Eng
FOR LEVITON USE ONLY
SPECIFICATIONS :
PROCESS :
MANUAL INTERIORS / BINDERY / FOLD SCHEME :
COMMENTS :
For manuals - designates cover specifications
Dimensions:
Material:
Thickness:
Finish:
:
Spot
CMYK
1:
4:
3:
2:
Color(s): over
1:
4:
3:
2:
Fonts:
Spot
CMYK
1:
4:
3:
2:
Color(s): over
1:
4:
3:
2:
Fonts:
Fold Line
Die Cut Punch/Drill Hole
Glue
Kiss Cut Cellophane
Fold Line
Perforate
Die Cut
Die Line Key:
DI-000-OSFHS-05A
8.5" x 14"
20 lb. Black Helvetica
1 1
Instruction sheet
D. Hunt 1/24/12
LE0121-3767
90/48 J. Smith B. Carberry
Vendor
D. Flinchbaugh
8.5"
14"
Part No.
FINAL
4.25"
2.8"
Part No.

Other Leviton Accessories manuals

Leviton ODC10-MDW User manual

Leviton

Leviton ODC10-MDW User manual

Leviton OSFHS-lxW User manual

Leviton

Leviton OSFHS-lxW User manual

Leviton OSFHD-AW Series Operation manual

Leviton

Leviton OSFHD-AW Series Operation manual

Leviton LDC Series User manual

Leviton

Leviton LDC Series User manual

Leviton Decora IPS06 User manual

Leviton

Leviton Decora IPS06 User manual

Leviton OSSMT-MDx User manual

Leviton

Leviton OSSMT-MDx User manual

Leviton Decora ODSIO-ID Series User manual

Leviton

Leviton Decora ODSIO-ID Series User manual

Leviton OSC10-M0W User manual

Leviton

Leviton OSC10-M0W User manual

Leviton Provolt ODC04-IDW User manual

Leviton

Leviton Provolt ODC04-IDW User manual

Leviton ACENTI User manual

Leviton

Leviton ACENTI User manual

Leviton IPP15-1L User manual

Leviton

Leviton IPP15-1L User manual

Leviton IPP0R User manual

Leviton

Leviton IPP0R User manual

Leviton Decora ODS15-ID Operation manual

Leviton

Leviton Decora ODS15-ID Operation manual

Leviton Lev-Lok MT162-SCE User manual

Leviton

Leviton Lev-Lok MT162-SCE User manual

Leviton ODS15-I1I User manual

Leviton

Leviton ODS15-I1I User manual

Leviton OSC04-R Series User manual

Leviton

Leviton OSC04-R Series User manual

Leviton Decora ODS10-IDx User manual

Leviton

Leviton Decora ODS10-IDx User manual

Leviton T6525-I User manual

Leviton

Leviton T6525-I User manual

Leviton CR15 User manual

Leviton

Leviton CR15 User manual

Leviton OSC04-I User manual

Leviton

Leviton OSC04-I User manual

Leviton Decora ODS15-IDx User manual

Leviton

Leviton Decora ODS15-IDx User manual

Leviton 279-S00 User manual

Leviton

Leviton 279-S00 User manual

Leviton Lumina LURPC-00W User manual

Leviton

Leviton Lumina LURPC-00W User manual

Leviton Lev-Lok M56AA User manual

Leviton

Leviton Lev-Lok M56AA User manual

Popular Accessories manuals by other brands

Philips CRP352 brochure

Philips

Philips CRP352 brochure

Sevylor Puddle Jumper owner's manual

Sevylor

Sevylor Puddle Jumper owner's manual

Burster 86-2208 Operation manual

Burster

Burster 86-2208 Operation manual

NCR 7705 Kit instructions

NCR

NCR 7705 Kit instructions

Invacare Aquatec Disk user manual

Invacare

Invacare Aquatec Disk user manual

Hydas 4671 instruction manual

Hydas

Hydas 4671 instruction manual

MK Sensors K4015 Installation and commissioning instructions

MK Sensors

MK Sensors K4015 Installation and commissioning instructions

PERMASTEEL PS-206-SS Use & care guide

PERMASTEEL

PERMASTEEL PS-206-SS Use & care guide

Honeywell RCW101N Specifications

Honeywell

Honeywell RCW101N Specifications

DANA P-333 parts list

DANA

DANA P-333 parts list

Huawei BTS3902E WCDMA installation guide

Huawei

Huawei BTS3902E WCDMA installation guide

Hytronik HMW31 Installation and instruction manual

Hytronik

Hytronik HMW31 Installation and instruction manual

Philips WelcomeBell 300 AddPush user manual

Philips

Philips WelcomeBell 300 AddPush user manual

Proceq Zehntner ZG8000 quick reference

Proceq

Proceq Zehntner ZG8000 quick reference

STEINEL PROFESSIONAL IS 3360 MX Highbay manual

STEINEL PROFESSIONAL

STEINEL PROFESSIONAL IS 3360 MX Highbay manual

DigiDesign Mbox 2 Getting started

DigiDesign

DigiDesign Mbox 2 Getting started

Clatronic KB 3714 instruction manual

Clatronic

Clatronic KB 3714 instruction manual

Fastus CD22 Series instruction manual

Fastus

Fastus CD22 Series instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.