2. Improper use
The pump must not be used for purposes other than the transfer of liquids.
Do not use the pump with explosive liquids or with low vapour pressure.
The pump cannot be used to generate isostatic or counter pressures.
The pump cannot be used to mix liquids generating an exothermal reaction.
The pump must be installed horizontally on a firm base.
The pump must be installed on a suitable hydraulic plant with inlet and outlet connections to proper suction and discharge
pipes.
The plant must be able to shut off the liquid flow independently from the pump.
Handling of aggressive liquids requires specific technical knowledge.
3. General notes
ZMA pumps are designed and built for the transfer of liquid chemical products having a specific weight, viscosity, temperature
and stability of state appropriate for use with centrifugal pumps in a fixed installation, from a tank at a lower level to a tank or a
pipe to a higher level.The characteristics of the liquid (pressure, temperature, chemical reactivity, specific weight, viscosity, vapour
tension) and the ambient atmosphere must be compatible with the characteristics of the pump and are defined upon ordering.
Impeller and static casings, in contact with the liquid, are constructed from thermoplastic materials; other parts in high chemical-
resistant materials.
The max. pump’s performances (capacity, head, rpm) are defined on the identification plate.
The value of the suction lift is defined upon ordering.
"ZMA" pumps are self-priming, centrifugal, horizontal, single stage, close coupled to a non-synchronous electric motor, with
side-inlet and upward-outlet for connection to the hydraulic system. They are foot-mounted for floor fixing.
At start-up the pipes must be empty and the pump body full of liquid.
The priming time depends on the suction lift and on the suction circuit (total length and diameter).
"ZMA" pumps cannot run dry.
The liquid being pumped may contain a maximum 1% of solid non-abrasive particles not greater than 0,1 mm in size.
The presence of fibrous, adhesive or abrasive bodies is not allowed.
Clockwise rotation seen from the motor side.
Make sure that the chemical and physical characteristics of the liquid have been carefully evaluated for pump suitability.
The specific weight which can be pumped at a temperature of 25°C (both of the liquid and the ambient) depends upon the dia-
meter of the impeller (shown on the identification plate) and the installed motor power (shown on the motor identification plate)
ans has to be defined upon ordering.
The level of kinematic viscosity must not exceed 10 cSt so as not to significantly modify the pump's performance (capacity, head,
suction lift, priming time).
The liquid temperature is a primary factor of suction lift and has to be defined upon ordering; at 60 °C the pump is not usable
as self-priming pump.