MAY 2020
01
Edition
H
A
w
L
ØD
N-m
3/8”
3/8”
1/2”
1/2”
3/4”
3/4”
3/4”
1”
36.4
36.4
46.7
46.7
72.0
72.0
72.0
29.8
29.8
39.9
40.0
56.2
56.2
56.1
67.7
35.0
35.0
40.0
47.0
47.0
47.0
47.0
0.5 Nm
0.5 Nm
1 Nm
2.5 Nm
2.5 Nm
2.5 Nm
7 Nm
10-80 Nm
20-110 Nm
40-210 Nm
70-350 Nm
100-500 Nm
140-700 Nm
140-980 Nm
0.74
0.96
1.70
2.54
3.66
5.94
6.46
DTP-80N
DTP-110N
DTP-210N
DTP-350N
DTP-500N
DTP-700N
DTP-980N
W H ØD KG
A
3/8”
3/8”
1/2”
1/2”
3/4”
3/4”
3/4”
1”
36.4
36.4
46.7
46.7
72.0
72.2
72.0
29.8
29.8
39.9
40.0
56.2
56.2
56.1
67.7
35.0
35.0
40.0
47.0
47.0
47.0
47.0
0.5 ft.lb
0.5 ft.lb
1 ft.lb
2.5 ft.lb
2.5 ft.lb
2.5 ft.lb
5 ft.lb
10-60 ft.lb
15-80 ft.lb
30-150 ft.lb
50-250 ft.lb
50-300 ft.lb
100-600 ft.lb
100-700 ft.lb
0.74
0.96
1.70
2.54
3.66
5.94
6.46
DTP-60F
DTP-80F
DTP-150F
DTP-250F
DTP-300F
DTP-600F
DTP-700F
380
380
535
650
860
1090
1230
L
380
380
535
650
860
1090
1230
LW H ØD KG
A
Unit : mmAccuracy : C.W. ±4% / C.C.W ±6%
Metric SAE
ITEM NO. Range ITEM NO. Range
BHOW TO SET TORQUE VALUE
MAINTENCE AND STORAGE
SPECIFICATION
TORQUE CONVERSION FACTORS
1. Push down the lock ring to unlocked.
2. Turn the adjustable handle Clockwise or
Anti-clockwise (Right or left) to set the desired torque.
3. Pull upper the lock ring to set finished.
0
28
210
170
130
90
50
190
150
110
70
200
160
120
80
40
180
140
100
60
0
28
210
170
130
90
50
190
150
110
70
200
160
120
80
40
180
140
100
60
1 2 3
0
28
210
170
130
190
150
110
200
160
120
180
140
0
28
210
170
130
90
50
190
150
110
70
200
160
120
80
40
180
140
100
60
N-M
170
190
150
200
160
180
190
160
180
A B
C
Lock
Unlock
Set
1. Please return torque value to just below lowest reading when not in use. Do not turn below lowest reading. (see C)
2. If this tool has not been used for a period of time, it shall be preloaded several times at its maximum torque setting. This will allow
internal lubricant to recoat.
3.
Clean this tool by wiping with a clean cloth after operation and storage in a dry environment.
Do not dip any type of liquid in this tool. This may damage the internal of this tool.
4. This tool should be recalibrated a period of 12 months, or 5,000 cycles, whichever occurs first.
To contact with local vendor, an authorized repair center for supporting. 1 Years
5000 Times
For example : ITEM NO. DTP-210N
To set torque to 135 Nm. Firstly push down and hold the lock ring and turn the
handle clockwise until the upper edge to 130 Nm (see A) and the reading “5” on
the long tube must align with the center link of scale perpendicularly so as to
acquire 130+5=135 Nm. (see B)
Units to be
converted
1 mN.m
1 cN.m
1 N.m
1 ozf.in
1 lbf.in
1 lbf.ft
1 gf.cm
1 kgf.cm(kp.cm)
1 kgf.m(kp.m)
1
10
1000
7.062
113
1356
0.098
98.07
9807
0.1
1
100
0.706
11.3
135.6
0.01
9.807
980.7
0.001
0.01
1
0.007
0.113
1.356
0.0001
0.098
9.807
0.142
1.416
141.6
1
16
192
0.014
13.89
1389
0.009
0.088
8.851
0.0625
1
12
0.0009
0.868
86.8
0.0007
0.007
0.738
0.005
0.083
1
0.00007
0.072
7.233
10.2
102
10197
72
1152.1
13826
1
1000
100000
0.01
0.102
10.2
0.072
1.152
13.83
0.001
1
100
0.0001
0.001
0.102
0.0007
0.0115
0.138
0.00001
0.01
1
=mN.m =cN.m =N.m =ozf.in =lbf.in =lbf.ft =gf.cm =kgf.cm
(kp.cm)
=kgf.m
(kp.m)
Corresponding unit
Conversion-formula :
Units to be converted × Factor = Corresponding unit
Example : Convert 5 lbf.ft into cN.m
Solution : 5 × 135.6 = 678 cN.m
www.matatakitoyo.com Made in Taiwan
MATATAKITOYO TOOL CO., LTD.
No. 63, Ln. 493, Sec. 3, Zhongshan Rd., Tanzi Dist.,
Taichung City 42754, Taiwan
TEL : 886-4-2533 5893
Manufacturer