Apr. 2020
02
Edition
Hold A B
C
1. Push down the lock ring to unlocked.
2. Turn the adjustable handle Clockwise or
Anti-clockwise (Right or left) to set the desired torque.
3. Pull upper the lock ring to set finished.
Unlock
Lock
Set
For example : ITEM NO. PPR-210N
To set torque to 135 Nm. Firstly push down and hold the lock ring and turn the
handle clockwise until the upper edge to 130 Nm (see A) and the reading “5” on
the long tube must align with the center link of scale perpendicularly so as to
acquire 130+5=135 Nm. (see B)
Metric SAE
# Matt finish # Shinny finish
H
A
W
L
ØD
N-m
PPR-5N
PPR-30N
PPR-110N
PPR-210N
PPR-350N
PPR-450N
PPR-800N
PPR-1500N
PPR-1500NS
PPR-2000N
0.05 Nm
0.2 Nm
0.5 Nm
1 Nm
1 Nm
2.5 Nm
5 Nm
10 Nm
10 Nm
10 Nm
1-5 Nm
6-30 Nm
20-110 Nm
40-210 Nm
70-350 Nm
75-450 Nm
100-800 Nm
300-1500 Nm
300-1500 Nm
400-2000 Nm
1/4”
1/4”
3/8”
1/2”
1/2”
3/4”
3/4”
3/4”
1”
1”
ØDLHW
0.28
0.30
0.86
1.20
1.40
3.14
6.60
11.6
11.6
13.0
KG
A
PPR-50i
PPR-200i
PPR-100F
PPR-150F
PPR-250F
PPR-300F
PPR-600F
PPR-1000F
PPR-1000FS
PPR-1500F
0.5 in.lb
1 in.lb
0.5 ft.lb
1 ft.lb
1 ft.lb
2.5 ft.lb
2.5 ft.lb
5 ft.lb
5 ft.lb
5 ft.lb
10-50 in.lb
40-200 in.lb
10-100 ft.lb
30-150 ft.lb
30-250 ft.lb
50-300 ft.lb
100-600 ft.lb
200-1000 ft.lb
200-1000 ft.lb
300-1500 ft.lb
1/4”
1/4”
3/8”
1/2”
1/2”
3/4”
3/4”
3/4”
1”
1”
ØDLHW
0.28
0.30
0.86
1.20
1.40
3.14
6.60
11.6
11.6
13.0
KG
A
1 Years
5000 Times
ITEM NO. Range ITEM NO. Range
Unit : mm
Accuracy : C.W.± 4% / C.C.W.± 6%
38.0
38.0
43.0
43.0
43.0
43.0
43.0
43.0
43.0
43.0
200
225
425
480
538
800
985
1763
1763
2300
29.0
29.0
37.0
46.3
46.3
70.0
70.0
68.6
68.6
76.0
24.0
24.0
29.0
43.0
43.0
69.0
69.0
67.4
67.4
68.0
38.0
38.0
43.0
43.0
43.0
43.0
43.0
43.0
43.0
43.0
200
225
425
480
538
800
985
1763
1763
2300
29.0
29.0
37.0
46.3
46.3
70.0
70.0
68.6
68.6
76.0
24.0
24.0
29.0
43.0
43.0
69.0
69.0
67.4
67.4
68.0
1 2 3
200
160
190
150
110
210
170
130
180
140
100
N-M
200
160
120
190
150
110
210
170
130
80
70
90
60
200
160
190
210
170
TORQUE CONVERSION FACTORS
HOW TO SET TORQUE VALUE
MAINTENCE AND STORAGE
SPECIFICATION
1. Please return torque value to just below lowest reading when not in use. Do not turn below lowest reading. (see C)
2. If this tool has not been used for a period of time, it shall be preloaded several times at its maximum torque setting. This will allow
internal lubricant to recoat.
3.
Clean this tool by wiping with a clean cloth after operation and storage in a dry environment.
Do not dip any type of liquid in this tool. This may damage the internal of this tool.
4. This tool should be recalibrated a period of 12 months, or 5,000 cycles, whichever occurs first.
To contact with local vendor, an authorized repair center for supporting.
Units to be
converted
1 mN.m
1 cN.m
1 N.m
1 ozf.in
1 lbf.in
1 lbf.ft
1 gf.cm
1 kgf.cm(kp.cm)
1 kgf.m(kp.m)
1
10
1000
7.062
113
1356
0.098
98.07
9807
0.1
1
100
0.706
11.3
135.6
0.01
9.807
980.7
0.001
0.01
1
0.007
0.113
1.356
0.0001
0.098
9.807
0.142
1.416
141.6
1
16
192
0.014
13.89
1389
0.009
0.088
8.851
0.0625
1
12
0.0009
0.868
86.8
0.0007
0.007
0.738
0.005
0.083
1
0.00007
0.072
7.233
10.2
102
10197
72
1152.1
13826
1
1000
100000
0.01
0.102
10.2
0.072
1.152
13.83
0.001
1
100
0.0001
0.001
0.102
0.0007
0.0115
0.138
0.00001
0.01
1
=mN.m =cN.m =N.m =ozf.in =lbf.in =lbf.ft =gf.cm =kgf.cm
(kp.cm)
=kgf.m
(kp.m)
Corresponding unit
Conversion-formula :
Units to be converted × Factor = Corresponding unit
Example : Convert 5 lbf.ft into cN.m
Solution : 5 × 135.6 = 678 cN.m
www.matatakitoyo.com Made in Taiwan
MATATAKITOYO TOOL CO., LTD.
No. 63, Ln. 493, Sec. 3, Zhongshan Rd., Tanzi Dist.,
Taichung City 42754, Taiwan
TEL : 886-4-2533 5893
Manufacturer