Memmert ICO Series User manual

ICO
HCP
ASSEMBLY INSTRUCTIONS
FOR STACKING
ICO150 AND ICO240
HCP150 AND HCP240

Manufacturer and customer service
Memmert GmbH + Co. KG
Willi-Memmert-Straße 90–96
D-91186 Büchenbach
Germany
Phone: +49 (0)9122 925-0
Fax: +49 (0)9122 14585
Email: [email protected]
Internet: www.memmert.com
Customer service:
Service hotline: +49 (0)9171 9792 911
Service fax: +49 (0)9171 9792 979
E-Mail: [email protected]
For service enquiries, please always specify the appliance number on the type plate.
Shipping address for repairs:
Memmert GmbH + Co. KG
Customer service
Willi-Memmert-Str. 90–96
DE-91186 Büchenbach
Germany
Please contact our customer service department before sending appliances for repair or
before returning equipment, or the shipment may be refused.
© 2019 MEMMERT GmbH + Co. KG
D39166 | Stand 09/2019
Subject to change without notice

3
About this manual
D39166 | date 09/2019
About this manual
Purpose and target audience
This manual provides instructions on stacking two identical ICO (ICOmed) CO2incubators
or two identical HCP humidity chambers. It is intended for use by trained personnel of
the operating company.
If you have been assigned with the installation of the appliance, you should read this
manual carefully before starting work. Familiarise yourself with the safety regulations.
Only perform work that is described in this manual. If there is something you do not
understand, or certain information is missing, ask your manager or contact the manufac-
turer. Do not do anything without authorisation.

4
General information
D39166 | date 09/2019
1. General information
Two ICO (ICOmed) incubators or two HCP humidity chambers of the same size can be
stacked on top of each other.
For secure stacking, stacking corners must be inserted in all four corners on the under-
side of the upper appliance. The upper appliance is fastened to the lower appliance using
the weight of the appliance itself.
1.1 Tilt protection
Due to the increased risk of overturning, size 150 and 240 appliances are also secured
using a connecting plate and two adjustable wall brackets on the rear panel.
1.2 Stacking process
►Size 150 appliances can be manually stacked by four people.
►Due to their height and weight, size 240 appliances must be stacked using an electric
manual pallet jack. For mounting purposes, the lower appliance must stand on a sub-
frame.
1.3 Stacking element
Due to their weight, size 240 appliances must be mounted using elevated stacking cor-
ners, which facilitate stacking using an electric manual pallet jack.
1.4 Mobile sub-frame (optional)
The “mobile sub-frame” option enables the stacked appliances to be moved slightly for
servicing purposes.
1.5 Installation requirements
Ensure that the floor of the installation site is pressure-resistant, stable and level and that
it is capable of reliably bearing the weight of two loaded appliances, as well as that there
is sufficient headroom. The wall structure should have a sufficiently static load-bearing
capability for mounting the wall bracket.
1.6 Required tools and materials
►Drill
►Torx screwdriver size 15
►Drill for wall plugs
►Allen key size 2.5
►Wall plugs or similar for fastening the appliance to the wall (not included in the scope
of delivery)
►Electric manual pallet jack (for size 240 appliances)

5
Safety regulations
D39166 | date 09/2019
2. Safety regulations
WARNING
Because of the heavy weight of the appliance, you could injure
yourself if you try to lift it. At least two people are needed to carry
size 50 appliances, and four people are required for size 105 and 150
appliances. Appliances larger than that may not be carried, but must
be transported using a manual pallet jack or forklift truck.
50 105 150 240
WARNING
The stacked appliances could fall over and cause serious injury if
they are not secured against falling over. The appliances should nev-
er be installed as a free-standing unit, but should always be fixed to
a wall.
CAUTION
You may get your hands or feet squashed when transporting
and installing the appliance. Wear protective gloves and safe-
ty boots. Only grasp the appliance at the sides of the base:
9

6
ICO/ICOmed/HCP stacking
D39166 | date 09/2019
3. ICO/ICOmed/HCP stacking
3.1 Preparations for mounting using a sub-frame
3.1.1 Remove the pre-assembled appliance feet.
►If the lower appliance is mounted on a sub-frame, the pre-assembled
adjustable feet must be removed.
1. Lift the lower appliance onto the
electric manual pallet jack.
2. Lift the appliance.
3. Remove the pre-assembled
appliance feet from the lower
appliance.
3.1.2 Adjust the sub-frame.
►The sub-frame must stand firm on the floor in a level position. Ensure
that the ground underneath it is suitable. (see page 4)
1. When you reach the installation site, pull out the adjustable feet on the sub-
frame.
NOTICE
NOTICE

7
ICO/ICOmed/HCP stacking
D39166 | date 09/2019
3.2 Stacking process
3.2.1 Stacking process for size 150 appliances using a sub-frame
1. Lift the lower appliance onto the sub-frame.
►The appliance feet must engage with the plastic leg plugs on the sub-frame.
2. Lift the upper appliance.
3. Push in the four stacking corners on the upper appliance .
4. Slowly release the appliance.
►The stacking corners must align with the top of the lower appliance.
5. Check that the appliance is supported on all corners.

8
ICO/ICOmed/HCP stacking
D39166 | date 09/2019
3.2.2 Stacking process for size 240 appliances using a sub-frame
1. Lift the lower appliance onto the sub-frame.
►The appliance feet must engage with the plastic leg plugs on the sub-frame.
2. Lift the upper appliance using an electric manual pallet jack.
3. Push in the elevated stacking corners on the upper appliance.

9
ICO/ICOmed/HCP stacking
D39166 | date 09/2019
4. Slowly and carefully move it over the lower appliance ⒶⒷ.
NOTICE
►The stacking corners must align with the top of the lower appliance.
5. Slowly release the appliance Ⓒ.
6. Check that the appliance is supported on all corners.
7. Slowly slide the manual pallet jack away Ⓓ.
C
D
A
B

10
ICO/ICOmed/HCP stacking
D39166 | date 09/2019
3.3 Fitting the connecting plate
1. Loosen the screwed-in M3x6 Torx screws on the appliance’s reverse panel.
2. Mount the connecting plate using M3x6 Torx screws (TX15).

11
ICO/ICOmed/HCP stacking
D39166 | date 09/2019
3.4 Fitting wall brackets
NOTICE
The adjustable wall brackets from the stacking set must be used for size 150 and 240
appliances.
1. Remove one M3x6 Torx screw from each of the appliances on the left or right side of
the frame.
2. Fit the wall brackets to the rear frame.
3. Drill holes, insert dowels and screw the tilt protection brackets into a suitable wall.
►Since the conditions (wall structure) at the installation site are unknown, no dowels
or similar materials for wall mounting are included in the scope of delivery.
The installation is now completed.
The distance from the wall can be adjusted by unscrewing the Allen screws and pulling
the bracket out.

12
Moving stacked appliances
D39166 | date 09/2019
4. Moving stacked appliances
WARNING
The stacked appliances could fall over and cause serious injury if
they are moved. After being fitted to the wall, appliances may only
be moved slightly for servicing purposes.
To do so, proceed as follows:
1. Open the locking pin on the sub-frame.
2. Pull the anti-tilt bracket out until the locking pin engages.
3. Remove the wall brackets from the wall.
4. Carefully pull the appliances away from the wall. Carry out the servicing and then
carefully push the appliances back towards the wall.
5. Insert the anti-tilt bracket again.
6. Attach the appliance to the wall again.
2
1




15/06/2012
HPP/IPPplus English
D24029
Memmert GmbH + Co. KG
Postfach 1720 | D-91107 Schwabach
Tel. +49 9122 925-0 | Fax +49 9122 14585
E-Mail: [email protected]
facebook.com/memmert.family
Die Experten-Plattform: www.atmosafe.net
D39166 | Version 09/2019
English
ICO/ICOmed/HCP assembly instructions
This manual suits for next models
5
Table of contents
Other Memmert Climate Chamber manuals

Memmert
Memmert ICP User manual

Memmert
Memmert hpp 1400 User manual

Memmert
Memmert WTB 6 User manual

Memmert
Memmert HPPeco User manual

Memmert
Memmert ICO User manual

Memmert
Memmert ICO User manual

Memmert
Memmert ICP User manual

Memmert
Memmert ICO User manual

Memmert
Memmert HPPeco User manual

Memmert
Memmert HPPlife Operating instructions