Ness D16 User manual

16 Zone Control Panel and Dialler
NESS D16
REVISION 2, JULY 2001
OWNER’S MANUAL
Technical Manuals Online! - http://www.tech-man.com

HEAD OFFICE:
Ness Security Products Pty Ltd
ACN 069 984 372
4 / 167 Prospect Hwy
Seven Hills NSW 2147 Australia
Ph +61 2 8825 9222
Fax +61 2 9674 2520
SYDNEY
02 8825 9222
MELBOURNE
03 9878 1022
BRISBANE
07 3343 7744
ADELAIDE (Aquavia Controls)
08 8277 7255
PERTH
08 0328 2511
NEW ZEALAND (NFS NZ)
+64 9 573 0401
“Australia’s largest
designer and
manufacturer of
high quality security
products”
WWW.NESS.COM.AU
Ness Security Products Pty Ltd
Quality
Endorsed
Company
ISO9001
LIC.No. QEC2074
NSW Head Office only
REVISION 2, JULY 2001
D16 USER MANUAL
Document Part Number: 890-247
For product: 100-687 D16 Control Panel
© 2001 Ness Security Products Pty Ltd ACN 069 984 372
D16installer4 pmo200701
Specifications may change without notice.
Technical Manuals Online! - http://www.tech-man.com

CONTENTS
Features ...................................................................... 4
Introduction................................................................. 5
Keypad ........................................................................ 6
Visual Indicators ......................................................... 7
OPERATION ................................................................ 8
Arming ..................................................................... 9
Disarming .............................................................. 10
Resetting Alarms ................................................... 10
Monitor Mode ........................................................ 11
Panic ...................................................................... 12
Duress .................................................................... 12
Excluding Zones ................................................... 13
Alarm Memory ....................................................... 14
PROGRAMMING ....................................................... 15
Programming Options Table ................................ 15
User Code programming ..................................... 16
Entry/Exit Timer programming ............................. 17
Telephone Number programming ....................... 17
Wireless Accessories ............................................ 18
Monitoring, described .......................................... 19
Remote Operation by Telephone ......................... 20
Troubleshooting .................................................... 22
Installation Record ................................................ 23
Technical Manuals Online! - http://www.tech-man.com

NESS D16 CONTROL PANEL - USER MANUAL
4
• 8 or 16 Fully programmable zones
• Any combination of 8 or 16 hardwire or
radio zones
• Full radio supervision
• Contact ID Dialler Format
• Ultra-Modern and Impact resistant
Housing
• Ness Audible Dialler Format
• "Follow Me" Audible Dialler Option
• Separate 24 HourTamper input
• Single or DoubleTrigger Zones
• Remote LCD Keypads (Max 3)
• Fully programmable via the system
Keypad - Eliminates the need for
expensive programmers or Proms.
• InbuiltVibration Sensor Analyser
• All programming data is permanently
stored in a non-volatile EEprom
memory
• True Dynamic BatteryTest every time
the Panel is Armed / Disarmed and
every hour
• Area Partitionable (2 Areas).Any Zone
can be programmed to any area, as
well as common areas
• Comes complete with an AC plug pack
and supports a 12V 7Ah battery to
maintain system security under all
power supply conditions
• Monitor Mode (Home Mode)
• Outputs are separately fused with
Automatic Reset Fuses
• Day Mode and Door Chime feature.
• Zone inputs can be split with two end-
of-line resistors so that two detection
devices (ie reed switches) can both be
monitored to provide maximum
security
• 30 Event Memory
• Supports 16 Radio Devices (Radio
PIRs, Radio Reeds etc)
• Supports 14 Radio Keys
• All inputs and outputs are heavily
protected against lightning and high
voltage supply transients.An earth
terminal is provided for extra protec-
tion
• 15 User Codes
• ‘Arm only’codes can be programmed
• Programmable Inputs to activate
selectable Outputs
• Designed utilising the latest SMD
Technology
• Forced Arming Feature
• Simple to Program and Use.
NESS D16 FEATURES
Technical Manuals Online! - http://www.tech-man.com

NESS D16 CONTROL PANEL - USER MANUAL 5
INTRODUCTION
The Ness D16 micro computer based 16 zone
control panel is the heart of your security system
to which all your detection devices connect.
Each Zone of the panel can be connected to one
or more detection devices to protect separate
rooms of your premises.
Detection devices may be connected to the D16
control system directly by cabling or with optional
wireless (Radio) devices.
Detection devices called Passive Infra-Red
Detectors (or P.I.R’s for short) can detect the
movement of an intruder by sensing their body
heat. P.I.R’s are used to cover various critical areas
of your premises where an intruder may enter or
trespass.Another detection device used is called a
Reed Switch. Reed Switches are attached to
windows and doors to detect if a window or door
has been opened. A Reed Switch consists of a
magnet which is normally attached to the moving
part of a window or door and the Reed switch
which mounts to the door or window frame.
The panel is “Armed” when it is set to detect an
intruder. At other times it is “Disarmed”.
Normally a zone is considered Sealed. Activation
of a detection device will cause the zone to be
Unsealed and may cause an alarm.
Detectors such as fire detectors and panic buttons
must be able to generate an alarm at all times
regardless of the panel setting. A zone with this
assignment is called a 24 hour zone.
Some detection devices may be required to
generate an alarm or warning only when the panel
is Disarmed. A zone with this assignment is called
a Day zone.
Before leaving the premises you must Arm the
panel to enable it to detect intruders and generate
an alarm. After arming, the panel will ignore
detectors during the Exit Delay Time to enable you
to depart without triggering an alarm.
Arming the system may be done through the
keypad or with the use of optional Radio Keys for
Arming by remote control from outside the
premises.
When you enter the premises the panel will ignore
selected zones for the Entry Delay Time and will
not alarm unless you don’t Disarm the panel during
this allowed time.
Disarming the system may be done by keypad or
with the use of optional Radio Keys.
Monitor mode allows selected zones to be Armed
while leaving others Disarmed if you wish to
protect a number of zones while you are at home.
If you wish to split your alarm system into two areas
with access limited to each area by code numbers
then Area operation is used. Radio Keys can also
Arm and Disarm Areas.
The control panel housing and the covers over
external sirens are protected by tamper switches
to detect someone attempting to disable the
security system. Activation of these switches will
cause an instant tamper alarm.
If a detector becomes faulty, you can Exclude the
associated zone so that it is totally ignored and
cannot generate an alarm. Including the zone will
enable it to generate an alarm again.
The control panel is fitted with a rechargeable
stand-by battery to ensure your security system
continues to operate if the mains power is
interrupted.This control panel automatically tests
the battery every hour and whenever you Arm/
Disarm the panel. (Dynamic Battery test).
Whenever an alarm occurs,it may be silenced with
a User Code or by optional Radio Keys, otherwise
it will reset at the end of Alarm Reset Time.
All alarms are stored in memory and may be
viewed at any time by entering Memory Mode.
Technical Manuals Online! - http://www.tech-man.com

NESS D16 CONTROL PANEL - USER MANUAL
6
KEYPAD
The Ness LCD keypad provides important
visual and audible indication of the system
status and is the main interface for
controlling the many powerful features of
the D16 system.
Information is displayed on a large LCD icon
display which is backlit for easy night
viewing.
DISPLAY TEST
To display all the keypad icons press and hold
the button for at least 2 seconds. All the
icons will be on whilst the button is held
down.
Display Test can be activated at any time
either in operating mode or any program
mode.
2
5
8
0
1
4
7
P
3
6
9
E
ARM
MONITOR
EXCLUDE
MEMORY
MEMORY
ALARM
13
EXCLUDE
12
MAINS
2
4
BATTERYMONITOR
Not Ready
11
1
93
10
2
ARMED
1
READY
ARM2
LINEPROGRAM
65 14 7
15 16
8
TAMPER
TM
RADIO
EACH KEY PRESS
1 beep
VALID ENTRY
3 beeps
ERROR BEEP
1 long beep
MAINS POWER IS OFF
BATTERY IS LOWor
10 beeps
10
BACKLIT LCD
ICON DISPLAY
PANIC BUTTONS
“Not Ready” light
The “Not Ready” light is on when the panel is
not ready to Arm.
i.e, a zone is unsealed, there may still be
movement in the premises or a door or
window left open
ARM BUTTON
MONITOR BUTTON
EXCLUDE BUTTON
MEMORY BUTTON
KEYPAD BEEPER
PROGRAM BUTTON ENTER BUTTON
NESS LCD KEYPAD (100-667)
Technical Manuals Online! - http://www.tech-man.com

NESS D16 CONTROL PANEL - USER MANUAL 7
VISUAL INDICATORS
ZONES 1-16 Zone Sealed Zone Unsealed Zone Alarm
ARMED Disarmed System Armed (AREA 1)
ARM2 Disarmed System Armed (AREA 2)
MONITOR Disarmed Monitor Mode
MAINS Normal Mains Power Fail
BATTERY Normal Backup Battery is Low
MEMORY Normal Memory Mode selected Alarms in memory
EXCLUDE Normal Exclude Mode selected Zones Excluded
TAMPER Normal Tamper unsealed Tamper Alarm
PROGRAM Normal Client Program Mode
LINE Normal Dialler is transmitting
READY System is ready to Arm
RADIO Normal
NOT READY Ready to Arm Not ready to Arm
• Zone unsealed or
• Power Fault or
• System Armed or
• Phone line fault
In Memory Mode indicates that a
Radio Key or other radio device has a
low battery
Indicates that a Radio Key or
other radio device has a low
battery
LIGHT OFF ON FLASHING
Phone line fault or Failure To
Communicate
KEYPAD LIGHTS OPERATION NESS LCD KEYPAD (100-667)
light
Technical Manuals Online! - http://www.tech-man.com

NESS D16 CONTROL PANEL - USER MANUAL
8
OPERATION
This section describes the operation of a
typical control panel installation. Keep in
mind that your installation may vary
depending on the selected options and
equipment. The operating instructions
which follow will endeavour to cover the
most common options.
Consult your installation company if you
require further information.
All control panel operations are controlled
by the D16 keypad except if an optional key
switch or radio control equipment is
installed.
OPERATING RULES
Generally, the panel will be Disarmed. Armed
or Monitor modes provide different levels of
security for your premises when you are
home or away. Three other temporary
modes; Program,Memory and Exclude,allow
you to perform various operations.The panel
will automatically exit from these temporary
modes if you do not press any buttons on
the keypad in a 4 minute period.
If you make a mistake while entering any
codes,press the enter button and start again.
When you are required to enter your access
code, you are given five opportunities to
enter it correctly. After the fifth invalid
attempt the alarm is activated (requiring the
correct code to silence the alarm). This
prevents anyone trying to guess your code
by entering random numbers.
AREA OPERATION
Area Partitioning allows the 16 zones to be
split into two partitions; Area1 and Area2.
The panel then effectively operates as two
separate systems sharing only the siren
outputs and dialler.
USER CODE ASSIGNMENT
A User Code assigned to an Area can Arm and
Disarm only that Area. User Codes assigned
to both Areas will operate both Areas
simultaneously.
COMMON AREA ZONES
Zones assigned to both Areas are Armed only
when Area1 and Area2 are both Armed.This
allows the Common Area zone/s to be shared
by both Areas.
For example, Office A and Office B operate
as separate areas but the entrance foyer used
by both offices is assigned to both areas
meaning it will automatically Arm when both
Areas have Armed. The Common Area then
automatically disarms when either Area1 or
Area2 Disarms.
OPERATION
Arming and Disarming is carried out as
normal from a single keypad or separate
keypads installed in both areas or by Radio
Key.
Area operation only applies to zones when
they are in the Armed state.This means that
Day, 24hr and Monitor zones are
independent of the area operations.
Note: Area partitioning is in addition to
Monitor Mode. Any zone may be allocated
to any area.
Technical Manuals Online! - http://www.tech-man.com

NESS D16 CONTROL PANEL - USER MANUAL 9
ARMING YOUR ALARM SYSTEM
The control panel must be Armed prior to
vacating the premises in order to detect
intruders. Ensure that the panel is not in
Program, Memory or Exclude modes.
Note:If the panel is already in alarm, you must first
silence the alarm before you can Arm.
If something is wrong when Arming the
control panel, the normal 3 beeps will be
replaced by other warnings.
10
10 beeps means Mains Power is
turned off or the Backup Battery is low.
One long beep indicates an invalid
entry or an alarm is outstanding and needs
to be reset by entering your User Code first.
1. The NOT READY light must be off
2. Press
[User Code]
...or
(If Arming Shortcut has been enabled by your installer)
...or by RADIO KEY, press the ON button
3. The ARMED light will turn on
• Leave the premises within the Exit Delay Time
• At the end of Exit Delay Time, 3 beeps will sound
ARMING
SIREN WARNING:
At the end of the exit time, all zones should
be Sealed. If any are Unsealed,the siren will
sound for 2 seconds as a warning to indicate
that those zones have been automatically
excluded. For maximum security, you should
return, Disarm, check the premises and then
Arm again. Continual warnings could mean
that a detector is faulty and may have to be
manually excluded.
If the auto-exclude option is disabled, the
siren will sound for the duration of reset time
if a zone is Unsealed at the end of exit time.
Technical Manuals Online! - http://www.tech-man.com

NESS D16 CONTROL PANEL - USER MANUAL
10
When you enter the protected premises
through a delay zone, the keypad responds
with regular beeps* as a reminder to Disarm.
You then have your programmed entry delay
time to Disarm the panel by entering one of
your user codes. If the panel is not Disarmed
by the end of the entry delay time, an alarm
will occur.
By using the optional radio keys you may
Disarm your system from within your
premises or from outside your entrance door.
1. Enter the protected premises via a delay zone
2. Press
[User Code]
...or by RADIO KEY, press the OFF button
3. The ARMED light will turn off
DISARMING
There is also the option to‘Chirp’ the outside
siren three times and to flash the strobe light
for two seconds as an indication that you
have Disarmed your system.
If you make a mistake in entering your code,
then you must press enter and start again.
Five incorrect entries will cause an alarm.
* If Entry Beeps are programmed on.
DISARMING YOUR ALARM SYSTEM
Your panel can be reset and the alarm
silenced by the same key sequence as
Disarming the panel.
If you arrive at your premises and find the
strobe light flashing (if installed), reset the
panel as above. To check the cause of the
alarm, you can view the alarms in memory
by entering Memory Mode.
1. Press
[User Code]
...or by RADIO KEY, press the OFF button
RESETTING AN ALARM
Technical Manuals Online! - http://www.tech-man.com

NESS D16 CONTROL PANEL - USER MANUAL 11
MONITOR MODE
Monitor mode allows you to Arm selected
zones while others are ignored. Typically,
perimeter zones (doors and windows) can be
monitored while you are at home.
Your installer must program which zones will
be active in Monitor mode.
The panel must be fully Disarmed before
Arming in Monitor Mode.
2. Press
[User Code]
...or
(If Monitor Shortcut has been enabled by your installer)
...or by RADIO KEY, press the OFF button twice
(If Radio Key Monitor Arming has been enabled by your installer)
3. The MONITOR light will turn on
• Only the zones which have been programmed by your
installer to be Monitor Zones will be Armed.
MONITOR MODE
If an alarm occurs while in Monitor mode,
entering
[User Code]
will silence the
alarm. This will also Disarm the panel, so
remember to enter monitor again if needed.
By using the optional Radio Keys you can
enter Monitor Mode by pressing the OFF
button twice within 4 seconds.(Your installer
must enable Radio Key Monitor Arming for
this to work).
Technical Manuals Online! - http://www.tech-man.com

NESS D16 CONTROL PANEL - USER MANUAL
12
For personal protection,the keypad contains
a PANIC feature which can be used to
instantly trigger the alarm.
The PANIC function may have been
programmed to be either:
AUDIBLE - activates siren or buzzers
or SILENT - If your system is monitored by
a Central Station, sends a PANIC report by
dialler. (If PANIC reports have been enabled by
your installer).
EMERGENCY FUNCTIONS
PANIC cannot be used while the panel is in
Program, Memory or Exclude mode.
Note: Your installer may have installed a
separate PANIC button. To activate the panic
alarm simply press that button.
A DURESS alarm can be triggered to alert the
Central Station that you are being forced to
Disarm the panel against your will.
To Disarm and send a DURESS alarm, prefix
your User Code with one of the digits 5, 6, 8
or 9 when Disarming.
1. Disarm by pressing [5,6,8 or 9]
[User Code]
DURESS
DURESS alarms are only used if your system
is monitored by a Central Station.
DURESS IS NORMALLY NOT ENABLED. TO
ENABLE THE DURESS FUNCTION, CONSULT
YOUR INSTALLER
1. Press
[User Code]
...or together
(If Double Key Panic has been enabled by your installer)
...or
(If Panic Shortcut has been enabled by your installer)
...or by RADIO KEY, press and hold the PANIC
button for 4 seconds
PANIC
Technical Manuals Online! - http://www.tech-man.com

NESS D16 CONTROL PANEL - USER MANUAL 13
EXCLUDING ZONES
If a detector becomes faulty and cannot be
Sealed when arming the panel, then its zone
may be Excluded so that it does not generate
alarms.
When zones have been Excluded, the
EXCLUDE light flashes continuously while
the panel is Disarmed and also when Armed.
Zones can only be Excluded when the panel
is Disarmed.
1. Press
[User Code]
...or
(If Exclude Shortcut has been enabled by your installer)
2. (The EXCLUDE light will turn on)
3. Enter the zone number of the zone/s to be Excluded.
[ZONE NUMBER] [ZONE NUMBER] (Up to 16 zones)
The zone light of each Excluded zone will turn on
4. Press to exit Exclude Mode
5. (The EXCLUDE light will flash continuously)
EXCLUDING ZONES
Zone Exclude IS not permanent. Excluded
zones are automatically INCLUDED next time
the panel is Disarmed.
Zones can be manually included by the same
method as Excluding. Simply use the
[ZONE NUMBER] sequence to turn OFF the
zone lights to be Included.
Technical Manuals Online! - http://www.tech-man.com

NESS D16 CONTROL PANEL - USER MANUAL
14
ALARM MEMORY
1. Press
[User Code]
...or
(If View Memory Shortcut has been enabled by your installer)
2. Press (The next most recent event will be displayed)
Press (The next most recent event will be displayed)
Press .....and so on (Up to 30 events)
3. Press to exit Memory Mode
4. (The MEMORY light will stop flashing)
VIEW ALARM MEMORY
The D16 Control Panel stores a
comprehensive Alarm Memory. The D16 will
remember Arming, Disarming, Low Battery,
Mains Fail and Alarms.
The memory is constantly upgraded and the
last 30 events are always available for
viewing.
This Memory display can only be selected
while the panel is in the Disarmed state.
TO CLEAR THE MEMORY LIGHT
The MEMORY light flashes continuously
when an alarm has occurred as a reminder
to view the alarm memory.
The MEMORY light stops flashing after the
memory is viewed as shown above.
The MEMORY light is automatically
cleared next time the panel is Armed.
MEMORY MODE - EVENTS INDICATED BY KEYPAD LIGHTS:
LIGHT ALARM EVENT
Zone lights 1-16 Zone alarm
ARM Panel Armed
(no lights) Panel Disarmed
TAMPER Tamper alarm (Siren cover, panel etc)
EXCLUDE Panic alarm
BATTERY Low Battery
MAINS Mains power failure
RADIO, BATTERY, ZONE Radio Device battery low
RADIO, BATTERY, ARM Radio Key battery low
Technical Manuals Online! - http://www.tech-man.com

NESS D16 CONTROL PANEL - USER MANUAL 15
PROGRAMMING
Various system options, as listed below, can be
programmed by the user. These options can only
be accessed from Program Mode.
User Codes may need to be re-programmed if a
person has forgotten their code,to give a new user
access to the system or to give someone temporary
access.
User Codes 2-15 can be set as Arm Only Codes.
These codes can Arm but cannot Disarm the panel.
(Useful for assigning to cleaners, tradesmen etc.)
You may need to change the Entry and Exit timers
if you find the delays are too long or short.
If Audible Monitoring is programmed by your
installer,the ‘Follow Me’Telephone Number is the
telephone number the dialler will call in the event
of an alarm.
If your Ness D16 panel is monitored by a Central
Station, the Follow Me number is ignored.
For all other programming changes, talk to your
installer.
The panel will automatically exit Program Mode
is no buttons are pressed within a 4 minute
period.
To enter Program Mode:
[MASTER CODE]
To exit Program Mode: then
OPTION OPTION No PROGRAMMEDRANGE
FACTORY
DEFAULT
User Code 1 (Master Code) P11E 123 3 to 6 digits
3 to 6 digits
3 to 6 digits
3 to 6 digits
3 to 6 digits
3 to 6 digits
3 to 6 digits
3 to 6 digits
3 to 6 digits
3 to 6 digits
3 to 6 digits
3 to 6 digits
3 to 6 digits
3 to 6 digits
3 to 6 digits
1 to 99 sec
10 to 990 sec
1 to 99 sec
Up to 15 digits
User Code 2 P12E
User Code 3 P13E
User Code 4 P14E
User Code 5 P15E
User Code 6 P16E
User Code 7 P17E
User Code 8 P18E
User Code 9 P19E
User Code 10 P20E
User Code 11 P21E
User Code 12 P22E
User Code 13 P23E
User Code 14 P24E
User Code 15 P25E
Entry Delay 1
Entry Delay 2
Exit Delay
Follow Me Telephone No.
P26E
P27E
P28E
P00E
20 seconds
60 seconds
60 seconds
NOTE:The Entry Delay 2 timer programs in 10 second intervals.Example:if a value of 6 is programmed,
the time is 60 seconds.
Technical Manuals Online! - http://www.tech-man.com

NESS D16 CONTROL PANEL - USER MANUAL
16
1. Press
[MASTER CODE]
(Enters Program Mode.The PROGRAM light will turn on).
2. Press (The existing code will be displayed by the keypad lights)
(Enter the Option Number of the User Code to be programmed. See Options Table).
3. Press
(Enter the new User Code twice).
4. Press then
(To exit Program Mode.The PROGRAM light will turn off).
PROGRAMMING USER CODES
EXAMPLE 1: To program User Code 1 (The Master Code).
11
Enter the new code Enter new the code again
PROGRAMMING
EXAMPLE 2: To program User Code 2 as an ARM ONLY code.
12
Enter the new code Enter new the code again
ARM
PROGRAM button
3 beeps
Selects a program
option (address)
The current value
is displayed
The keypad lights or
icons will display the
current value
Enter new
data
3 beeps
ENTER button
ENTER button
2 or 3 Digit Option
(00 to 119)
Enter new value
using keys 0 - 9
KEY
SEQUENCE
IN
PROGRAM
MODE
To enter Program Mode:
[MASTER CODE]
To Exit Program Mode: then
Technical Manuals Online! - http://www.tech-man.com

NESS D16 CONTROL PANEL - USER MANUAL 17
PROGRAMMING
1. Press
[MASTER CODE]
(Enters Program Mode.The PROGRAM light will turn on).
2. Press (The existing Telephone No. will be displayed by the keypad lights)
3. Press (The new Telephone No. will be displayed)
(Enter the new Telephone Number).
4. Press then
(To exit Program Mode.The PROGRAM light will turn off).
PROGRAMMING FOLLOW ME TELEPHONE NUMBER
EXAMPLE 5:
To program the Follow Me Telephone Number
00
Enter the new Telephone Number
(Up to 15 digits long)
EXAMPLE 6:
To delete the Follow Me Telephone Number
1. Press
[MASTER CODE]
(Enters Program Mode.The PROGRAM light will turn on).
2. Press (The existing time will be displayed by the keypad lights)
(Enter the Option Number of the Timer to be programmed. See Options Table).
3. Press
(Enter the new time, from 1-99 seconds).
4. Press then
(To exit Program Mode.The PROGRAM light will turn off).
PROGRAMMING ENTRY/EXIT TIMERS
EXAMPLE 4: To program EXIT DELAY.EXAMPLE 3: To program ENTRY DELAY 1.
Technical Manuals Online! - http://www.tech-man.com

NESS D16 CONTROL PANEL - USER MANUAL
18
WIRELESS PRODUCTS
RADIO ACCESSORIES
Ask your installer about the range Ness radio
devices. for the optional extra convenience of
wireless remote control and wireless detection.
Operating your Ness security system can be as
convenient as opening your car door. The Ness
Radio Key™ provides the benefits of separate ON,
OFF and PANIC buttons in a slim, waterproof
remote control.
* Ness radio products require a Ness Radio
Interface (100-200) to be fitted to the control panel.
NESS RADIO KEY 3 BUTTON
Fully waterproof,ultra slim 3 button
Radio Key for remote control of the
D16 control panel.
With separate buttons for ON (Arm),
OFF (Disarm) and PANIC functions.
Part No.
100-664
OFF
ON
PANIC
NESS RADIO PIR
Ness Radio PIR (Passive Infrared)
motion detector for wireless
motion detection.
Can be used in combination with
Ness hardwired detectors in areas
where it is not possible to install
wires.
Part No.
100-663
NESS RADIO REED SWITCH
Ness Radio Reed Switch for wireless
door and window protection.
Part No.
100-662
NESS RADIO KEY PENDANT
Fully waterproof pendant style
transmitter can be used as a
portable wireless Panic button.
Supplied with a neckchain as well
as wristwatch straps. Ideal for use as a medical
alarm for the elderly or infirm. (Central Station
Monitoring is especially recommended when used
for medical alarm purposes).
Part No.
100-665
NESS RADIO SMOKE
DETECTOR
Radio Smoke Detector using
Ionisation smoke detection
technology. With on board
sounder. A single battery
powers the smoke detector
and the transmitter.
Part No.
100-203
NESS RADIO KEYPAD
A unique fully portable radio
keypad. The Ness Radio
Keypad provides totally
wireless Arming/Disarming of
the Ness D8, D16 & D24
control panels.
Also operates Monitor mode and Panic when used
with the Ness D16, D24 panels.
The Ness radio Keypad is suitable for use as a
portable keypad or for adding an extra keypad in
areas where it is not possible to install wires.
Part No.
100-001
Valid Low Battery
Technical Manuals Online! - http://www.tech-man.com

NESS D16 CONTROL PANEL - USER MANUAL 19
AUDIBLE MONITORING
CENTRAL STATION MONITORING
The D16 control panel has an on-board digital
dialler which can send detailed alarm messages to
a Central Monitoring Station.
The digital messages can include information
about the zone or zones which caused the alarm,
tamper alarms,low battery or mains failure reports,
and it can also (by user number) identify the users
who Arm and Disarm the system.
Central Station Monitoring is highly recommended
and is the most effective method of monitoring
your D16 alarm system. For further information
about 24 hour monitoring,contact your installer or
Ness Security Products.
AUDIBLE MONITORING
The D16 can also be programmed to send audible
messages to any telephone or mobile phone.
When programmed for audible monitoring, the
D16 calls a pre-programmed number (or numbers)
and sounds a series of beeps over the phone.These
beeps can identify the zone or zones which caused
the alarm and well as several other alarm types.
* The programming of Primary and Secondary
phone numbers is an Installer Programming
option.
** The Follow Me Telephone Number replaces
the Primary AND Secondary telephone
numbers.
FOLLOW ME TELEPHONE NUMBER
Alarms are normally reported using the Primary
and Secondary telephone numbers.* When
Audible Monitoring is enabled, the Follow Me
Telephone Number is available** and can be
programmed in User Program mode.
See page 17 for information on programming the
Follow Me Telephone Number.
AUDIBLE MONITORING SEQUENCE
When triggered by an alarm, the D16 will dial the
programmed telephone number/s and output the
audible message for 45 seconds or until it is
acknowledged.
ACKNOWLEDGING THE ALARM
The person receiving the call can then
acknowledge the alarm by pressing the key on
their telephone. Press the key for at least 2
seconds during pauses in the audible message.
If the alarm is not acknowledged,the keypad’s LINE
light will flash continuously until the panel is next
Armed.
MONITORED PREMISES
CENTRAL STATION MONITORING
TELEPHONE LINE MONITORING STATION
MONITORED PREMISES
AUDIBLE MONITORING
TELEPHONE LINE MOBILE TELEPHONE
FIXED TELEPHONE
Technical Manuals Online! - http://www.tech-man.com

NESS D16 CONTROL PANEL - USER MANUAL
20
OPERATING THE D16 BY TELEPHONE
The D16 will allow a user to call in to the
panel, using a standard DTMF telephone,
and remotely Arm or Disarm all areas and
also turn on or off Aux 1 and Aux 2.
To ensure security of operation a user can
only carry out remote operations after
entering a valid user code.
REMOTE CONTROL FUNCTIONS NEED:
•A telephone with DTMF tones.
•A Valid User code programmed in the
D16.
•The Telephone number that the D16 is
connected to.
SEQUENCE OF OPERATION.
1. Phone the D16 telephone number and
listen for the required number of rings
(ring ring...ring ring) and then hang up.
2. Wait 10 seconds and then call the
number again within 50 seconds.
3. The D16 will answer the second call
immediately, sound a beep for 2 seconds
then, after a pause, it will sound a lower
frequency tone. The D16 is now ready to
receive telephone commands.
4. Press the button on the telephone.
This tells the D16 that telephone
commands will follow. The D16 will
respond with either 3 beeps if all OK
(One long beep means try again).
5. Now enter a valid User Code (that is
normally used for Arming or Disarming
the D16) followed by the button.
The D16 will respond with 3 beeps if it
REMOTE OPERATION
recognises the code or 1 long beep to
signal the code was invalid and to try
again.
6. Enter the required command.
See: Summary Of Telephone Commands.
7. Press to finish. This tells the D16
to hang up. Also hang up your
telephone.
AUDIBLE FEEDBACK
3 BEEPS:
• The User Code is valid
• Successful Arming or Disarming
• An Auxiliary output has been turned ON.
1 LONG BEEP:
• D16 is already Armed
• Invalid code.Try again.
1 SHORT BEEP:
• An Auxiliary output has been turned OFF.
NOTES
• If the D16 does not receive commands for
periods longer than 10 seconds it will
assume that the call is finished and it will
hang up.
• If an alarm occurs which requires the D16
to dial out while attempting remote
control, the D16 will treat the alarm as a
priority, give a constant tone as a warning
and then hang up.
• When all remote control commands are
finished press to force the D16 to
hang up.
Technical Manuals Online! - http://www.tech-man.com
Other manuals for D16
4
Table of contents
Other Ness Control Panel manuals
Popular Control Panel manuals by other brands

TIS
TIS Venera Switch Installation and programming manual

Ampac
Ampac LoopSense EN54.2 user manual

Cobalt Digital Inc
Cobalt Digital Inc OGCP-9000 product manual

Altimium
Altimium CP8N user manual

SJE Rhombus
SJE Rhombus Installer Friendly Series Installation Instructions and Operation/Troubleshooting Manual

AUDAC
AUDAC DW5066 User manual & installation guide