Xperience platform
All of Nexmosphere’s controllers are built on the same platform principles. If this is your rst time using a Nexmosphere
controller, we recommend to rst read https://nexmosphere.com/technology/xperience-platform/ to learn the basics about
our platform and its terminology.
XN-135
The XN-135 is an Xperience controller with 2 X-talk interfaces:
1. X-talk interface 001
2. X-talk interface 002
USB. 5V Power input and API interface (micro-USB connector)
LED. White status LED
Hardware setup
1. Connect one or more Elements to any of the 2 X-talk interfaces.
2. Connect the micro-USB cable to a 3rd party device (e.g. Digital Signage Player or PC).
3. Wait until the white status LED stops blinking. This lasts about 5 seconds.
Software setup for testing (Terminal)
Typically, the XN-135 controller is connected to a 3rd party device, such as a Digital Signage Player, on which CMS software is installed which has built-in
functionality for sending and receiving Serial Events. However, if you want to do a rst test on a PC or Mac, follow the instructions below:
1. Download a terminal program. For example Termite or Hercules.
2. Open the Terminal program and go to settings. Choose the COM port on which the XN-135 controller enumerated*.
In most cases this is the highest available number in the COM port drop-down setting.
3. Set the COM port settings to the following values
Baudrate 115200 Flow Control None
Parity None EOL CR+LF
Data Bits 8 Protocol ASCII
Stop Bits 1
4. Set the COM port to “Open”. The controller is now ready for use.
5. When sending consecutive API serial commands to the XN-135 controller, place a 50mS delay between each command.
*In case the XN-135 controller is not recognized as a COM port by the 3rd party device, a driver (Prolic PL2303) can be downloaded here.
Functionality
The XN-135 runs our API which provides serial output when a specic sensor Element is triggered (for example a pick-up,
or -motion sensor or touch button) and provides control over output Elements (for example controlling LED strips) via serial
input commands. These API serial commands are typically used to create interactive Xperiences for Digital Signage.
The complete API Manual and additional helpful documents can be found on https://nexmosphere.com/support-
documentation. To get you started, we’ve included some starter examples of our Elements and the corresponding API serial
commands on the following pages.
3rd party devices and software
This Quick Start Guide oers a generic explanation of the setup and operation of the XN-135 Xperience controller. It does
not cover information on how to integrate the Controllers, Elements and their API triggers in specic 3rd party devices or
software. We have manuals available with step-by-step instructions on how to integrate Nexmosphere products with the
products of our hardware, -and software partners. You’ll nd these on the support and partner pages of our website.
Nexmosphere
High Tech Campus 10 (Mμ building)
5656 AE Eindhoven • The Netherlands
T +31 40 240 7070
Esupport@nexmosphere.com
QUICK START GUIDE

© 2020 Nexmosphere. All rights reserved. v1.0 / 04-20
All content contained herein is subject to change without prior notice.
1
XN
XN
001 002 003
003
004
008 007 006 005
001 002
1 2
USB
LED
© 2020 Nexmosphere. All rights reserved. v1.0 / 04-20
All content contained herein is subject to change without prior notice.
Nexmosphere
High Tech Campus 10 (Mμ building)
5656 AE Eindhoven • The Netherlands
T +31 40 240 7070
Esupport@nexmosphere.com
2


When an XY-Presence sensor connected to X-talk
interface 001 detects a person in distance zone 4, the
following API serial command is sent from the XN-135 to
the 3rd party device: X001A[4]
When an XY-Presence sensor connected to X-talk
interface 001 does not detect a person, the following API
serial command is sent from the XN-135 to the 3rd party
device: X001A[1]

When tag 2 is picked up from an antenna connected to
X-talk interface 001 the following API serial commands are
sent from the XN-135 to the 3rd party device:
XR[PU002]
X001A[1]
When tag 1 is placed on an antenna connected to X-talk
interface 001, the following API serial commands are sent
from the XN-135 to the 3rd party device:
XR[PB001]
X001A[0]

When button 1 of a (touch) button interface connected
to X-talk interface 002 is pressed, the following API serial
commands are sent from the XN-135 to the 3rd party
device: X002A[3]
When button 4 of a (touch) button interface connected
to X-talk interface 002 is pressed, the following API serial
commands are sent from the XN-135 to the 3rd party
device: X002A[17]
XN-135
(Xperience controller)
XY-146
(presence sensor)
USB-A to Micro-USB cable
(connect to 3rd party device)
XN
XN-135
(Xperience controller)
USB-A to Micro-USB cable
(connect to 3rd party device)
XR
XR-C10
(RFID antenna)
XR-C10
RFID Tags
(number 1-3)
XR-DR1
(RFID antenna driver
XN
XN-135
(Xperience controller)
USB-A to Micro-USB cable
(connect to 3rd party device)
XT-B4N
(4x buon interface)
XT-4F
(Touch buons)
Push buons
(with LED, 4x)
XT-B4
1 2 3 4
XN
© 2020 Nexmosphere. All rights reserved. v1.0 / 04-20
All content contained herein is subject to change without prior notice.
Nexmosphere
High Tech Campus 10 (Mμ building)
5656 AE Eindhoven • The Netherlands
T +31 40 240 7070
Esupport@nexmosphere.com
3


To set all button LEDs of a (touch) button interface
connected to X-talk interface 002 to “on”, send the
following API commands from the 3rd party device to the
XN-135 controller:

To initiate an X-Wave LED pattern on an X-Wave connected
to X-talk interface 002, send one of the following API
example commands from the 3rd party device to the XN-
135 controller:

The XN-135 Xperience controller has 2 X-talk interfaces to which any combination of Elements can be connected. For
example, two of the examples in this Quick Start Guide can be combined on a single XN-135. The API commands and
operation will remain the same. When connecting multiple Elements that require a high amount of current (LEDs or push
buttons with LED ring), calculate the total required current of the Elements and check if this is within the specication of
the controller and its power supply source.
To set all button LEDs of a (touch) button interface
connected to X-talk interface 002 to “o”, send the
following API commands from the 3rd party device to the
XN-135 controller:
40% brightness, color 0 (white), 0.5 second ramp time
Blue pulsing pattern (99% to 20%), 1.8 second ramp time
White wave pattern moving to the left
X002A[255]
X002B[240005]
X002B[399C1801020C180018]
X002B[499018001200009]
X002A[0]
XN-135
(Xperience controller)
USB-A to Micro-USB cable
(connect to 3rd party device)
XT-B4N
(4x buon interface)
XT-4F
(Touch buons)
Push buons
(with LED, 4x)
XT-B4
1 2 3 4
XN
XN-135
(Xperience controller)
USB-A to Micro-USB cable
(connect to 3rd party device)
XW-L96
(X-Wave LED)
XW-L9
XN
XN-135
(Xperience controller)
USB-A to Micro-USB cable
(connect to 3rd party device)
XW-L96
(X-Wave LED)
XW-L9
XN

Other Nexmosphere Controllers manuals

Nexmosphere SM-125 User manual

Nexmosphere

Nexmosphere SM-125 User manual

Nexmosphere XPERIENCE XC-860 User manual

Nexmosphere

Nexmosphere XPERIENCE XC-860 User manual

Nexmosphere XM-350 User manual

Nexmosphere

Nexmosphere XM-350 User manual

Nexmosphere XY-240 User manual

Nexmosphere

Nexmosphere XY-240 User manual

Nexmosphere XM-350 User manual

Nexmosphere

Nexmosphere XM-350 User manual

Nexmosphere XN-115 User manual

Nexmosphere

Nexmosphere XN-115 User manual

Nexmosphere XN-165 XPERIENCE User manual

Nexmosphere

Nexmosphere XN-165 XPERIENCE User manual

Nexmosphere XN-180 User manual

Nexmosphere

Nexmosphere XN-180 User manual

Nexmosphere XPERIENCE XC-748 User manual

Nexmosphere

Nexmosphere XPERIENCE XC-748 User manual

Nexmosphere XPERIENCE XC-948 User manual

Nexmosphere

Nexmosphere XPERIENCE XC-948 User manual

Nexmosphere XM-350 User manual

Nexmosphere

Nexmosphere XM-350 User manual

Nexmosphere XC-720 User manual

Nexmosphere

Nexmosphere XC-720 User manual

Nexmosphere XN-135M3 User manual

Nexmosphere

Nexmosphere XN-135M3 User manual

Nexmosphere XPERIENCE XM-350 User manual

Nexmosphere

Nexmosphere XPERIENCE XM-350 User manual

Nexmosphere XC-841 User manual

Nexmosphere

Nexmosphere XC-841 User manual

Nexmosphere XN-185 User manual

Nexmosphere

Nexmosphere XN-185 User manual

Nexmosphere XM-350 User manual

Nexmosphere

Nexmosphere XM-350 User manual

Nexmosphere XPERIENCE XC-938 User manual

Nexmosphere

Nexmosphere XPERIENCE XC-938 User manual

Nexmosphere XC-741 User manual

Nexmosphere

Nexmosphere XC-741 User manual

Nexmosphere XPERIENCE XN-135M8L User manual

Nexmosphere

Nexmosphere XPERIENCE XN-135M8L User manual

Nexmosphere XPERIENCE XC-941 User manual

Nexmosphere

Nexmosphere XPERIENCE XC-941 User manual

Nexmosphere XC-847 User manual

Nexmosphere

Nexmosphere XC-847 User manual

Nexmosphere XM-350 User manual

Nexmosphere

Nexmosphere XM-350 User manual

Nexmosphere XC-760 User manual

Nexmosphere

Nexmosphere XC-760 User manual

Popular Controllers manuals by other brands

WELBA WTS-300 Installation and operating instructions

WELBA

WELBA WTS-300 Installation and operating instructions

Sealey SA4FR/38 instructions

Sealey

Sealey SA4FR/38 instructions

MidNite Solar Classic 150 owner's manual

MidNite Solar

MidNite Solar Classic 150 owner's manual

BEIER-Electronic SV3-1-8Z instruction manual

BEIER-Electronic

BEIER-Electronic SV3-1-8Z instruction manual

Freescale Semiconductor TRK-MPC5604B quick start guide

Freescale Semiconductor

Freescale Semiconductor TRK-MPC5604B quick start guide

IAI XSEL-R First step guide

IAI

IAI XSEL-R First step guide

Morningstar TriStar Professional TS-60M Installation, operation and maintenance manual

Morningstar

Morningstar TriStar Professional TS-60M Installation, operation and maintenance manual

Magicar M4200 installation guide

Magicar

Magicar M4200 installation guide

Siemens DESIGO PX Series manual

Siemens

Siemens DESIGO PX Series manual

Banner DXM1200-X2 instruction manual

Banner

Banner DXM1200-X2 instruction manual

Smartgen HGM6100N Series user manual

Smartgen

Smartgen HGM6100N Series user manual

Thermal Solutions Boiler Control TSBC instruction manual

Thermal Solutions

Thermal Solutions Boiler Control TSBC instruction manual

Ewellix CASM-32 Installation, operation and maintenance manual

Ewellix

Ewellix CASM-32 Installation, operation and maintenance manual

Bticino F470/1 Instructions for use

Bticino

Bticino F470/1 Instructions for use

Kobelt 6527 Owner's Operation, Installation & Maintenance Manual

Kobelt

Kobelt 6527 Owner's Operation, Installation & Maintenance Manual

SAJ VM1000 user manual

SAJ

SAJ VM1000 user manual

LK Armatur 150  SmartSol instruction manual

LK Armatur

LK Armatur 150 SmartSol instruction manual

GRAF & MEYER EVA 16 2.0 Start-up

GRAF & MEYER

GRAF & MEYER EVA 16 2.0 Start-up

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.