DIGITALPRESSUREGAUGE
INSTRUCTION MANUALVer.7.1
PG-200
1
Nishi-ShinjukuPrimeSquare.,7-5-25
Nishi-ShinjukuShinjuku-kuTokyo160-0023,Japan
https://www.nidec-copal-electronics.com
Formoredetailedinformationpleaseaskforthe
nearestdistributororthefollowingsalescenter.
YouaregreatlyappreciatedforpurchasingCopal'sModel
PG−200 digital Pressure Gauge. You should read this
instructionmanualthoroughlytooperatethePG−200in
optimumstate.
CAUTION Thiscautionmarkdescribeswhenthereisapossibilitythatusermaysufferfromdamageorphysical
damagemayoccuriftheproductisusedimproperly.
CAUTION
⑴Theproduct,whichisaprecisioninstrument,mustbetakenspecialcarenottobedamagedbyimpactnorbybeingdroppedwhenitistrasportedandinstorage.
⑵Theproductmustbeavoidedinstoragewhereisdusty,drippingandvibrated.
⑴Mountingtheattachmentforpaneltype
Iffightenigtheattachmenttothepressureport,thetighteningtorqueshouldbearound1N・m.
⑵Pipingforstand-alonetype
Forpiping,usethehexagonalportionofthepressureportfordriving.
⑶Mediatobeused
ThePressureGaugeshouldbeusedforfluidsthatcannotcorrodethediaphragmofSUS316L,pressureportofSUS316andO-ringoffluororubber.
⑷Excessivepressure
The pressure to be measured is within the specified range. Measurement of a higher pressure than the maximum allowable one may cause performance
degradationordestruction.
⑸Internalbattery
①ReplacebatterywithToshibaBatteryCo.,Ltd./ERVM3.6V/lithiumbatteryonly.Useofanotherbatterymaypresentariskoffireorexplosion.Ifyouneed
replacebattery,pleaseplaceanorderwithus.
②When“LOBAT”signisdisplayed,thebatteryshouldbereplaced.
③Thebatteryusedinthisdevicemaypresentriskoffireofchemicalburnifmistreated.Donotrecharge,disassemble,heatabove100℃(212°F),orincinerate.
④Disposeofusedbatterypromptly.Keepawayfromchildren.Donotdisassembleanddonotdisposeofinfire.
⑹Maintenance
IfthePressureGaugegetsdirty,wipeitoffwithhardlysqueezedclothcontaininganeutraldetergent.Donotuseanythinnerandbenzine.
⑺Protectionagainstnoises
①NoiseshavingmixedintheswitchoutputorpowerlinemaycausethePressureGaugetochangethepressureindication,malfunctionorbebroken.
TakesomemeasuretoputthePressureGaugeawayfrompowerlineoruseshieldedwire.ItiseffectivetogroundthePressureGauge.
②Ifthe switchoutputhasaninductionloadsuch asrelayorsolenoidconnectedtoit, itshouldhaveasurgeabsorbercircuit putinit.Therelaycontacts
shouldhaveacontactpreventivecircuitputinittopreventnoisesfrombeinggenerated.
⑻Prohibitionofshort-circuitingtheswitchterminals
Donotshort-circuittheswitchoutputterminaltoanypowerterminal.Theinternalcircuitmaybebroken.
§
1. HandlingNote
§
2. TRANSPORTATION&STORAGE