DIGITALPRESSUREGAUGE
INSTRUCTION MANUALVer.7.1
PG-200
1
Nishi-ShinjukuPrimeSquare.,7-5-25
Nishi-ShinjukuShinjuku-kuTokyo160-0023,Japan
https://www.nidec-copal-electronics.com
Formoredetailedinformationpleaseaskforthe
nearestdistributororthefollowingsalescenter.
YouaregreatlyappreciatedforpurchasingCopal'sModel
PG−200 digital Pressure Gauge. You should read this
instructionmanualthoroughlytooperatethePG−200in
optimumstate.
CAUTION Thiscautionmarkdescribeswhenthereisapossibilitythatusermaysufferfromdamageorphysical
damagemayoccuriftheproductisusedimproperly.
CAUTION
⑴Theproduct,whichisaprecisioninstrument,mustbetakenspecialcarenottobedamagedbyimpactnorbybeingdroppedwhenitistrasportedandinstorage.
⑵Theproductmustbeavoidedinstoragewhereisdusty,drippingandvibrated.
⑴Mountingtheattachmentforpaneltype
 Iffightenigtheattachmenttothepressureport,thetighteningtorqueshouldbearound1N・m.
⑵Pipingforstand-alonetype
 Forpiping,usethehexagonalportionofthepressureportfordriving.
⑶Mediatobeused
 ThePressureGaugeshouldbeusedforfluidsthatcannotcorrodethediaphragmofSUS316L,pressureportofSUS316andO-ringoffluororubber.
⑷Excessivepressure
 The pressure to be measured is within the specified range. Measurement of a higher pressure than the maximum allowable one may cause performance
degradationordestruction.
⑸Internalbattery
①ReplacebatterywithToshibaBatteryCo.,Ltd./ERVM3.6V/lithiumbatteryonly.Useofanotherbatterymaypresentariskoffireorexplosion.Ifyouneed
replacebattery,pleaseplaceanorderwithus.
②When“LOBAT”signisdisplayed,thebatteryshouldbereplaced.
③Thebatteryusedinthisdevicemaypresentriskoffireofchemicalburnifmistreated.Donotrecharge,disassemble,heatabove100℃(212°F),orincinerate.
④Disposeofusedbatterypromptly.Keepawayfromchildren.Donotdisassembleanddonotdisposeofinfire.
⑹Maintenance
 IfthePressureGaugegetsdirty,wipeitoffwithhardlysqueezedclothcontaininganeutraldetergent.Donotuseanythinnerandbenzine.
⑺Protectionagainstnoises
①NoiseshavingmixedintheswitchoutputorpowerlinemaycausethePressureGaugetochangethepressureindication,malfunctionorbebroken.
 TakesomemeasuretoputthePressureGaugeawayfrompowerlineoruseshieldedwire.ItiseffectivetogroundthePressureGauge.
②Ifthe switchoutputhasaninductionloadsuch asrelayorsolenoidconnectedtoit, itshouldhaveasurgeabsorbercircuit putinit.Therelaycontacts
shouldhaveacontactpreventivecircuitputinittopreventnoisesfrombeinggenerated.
⑻Prohibitionofshort-circuitingtheswitchterminals
 Donotshort-circuittheswitchoutputterminaltoanypowerterminal.Theinternalcircuitmaybebroken.
§
1. HandlingNote
§
2. TRANSPORTATION&STORAGE
2
⑴Model
⑵Measurement………………Gaugepressure.(102AP/102AH:absolute)
⑶Indication…………………3-1/2digits,000〜1999Max,digitalLCDdisplay.
⑷Indication…………………Around3times/sec.
⑸Accuracy …………………±0.5%F.S.±2digit(at25℃±5℃)
⑹Temperaturecharacteristics
 atzeropoint;±0.05%F.S./℃±2digit(102G/102GP/102VP/102VH/103G/103GP/103GMP)
       ±0.1%F.S./℃ ±2digit(101G/101GP/102AP/102AH)
 inSPAN  ;±0.05%Reading/℃ ±2digit
⑺Switchingfeatures
 Numberofsetpoints ……Two,HIandLO,activatidatupperlimit.
 Setrangedivisions………000〜1000,HIandLO.
 Settingmethod……………WithtrimmereachforHIandLO.Setvalueindicationcanbemadetotimewithsettingswitch.
 Operatingaccuracy ………Within±3divisionsfromindicationvalue.
 Difference…………………Within4divisions,fixed.
 Outputsystem……………NPNopencollectorof30Vdcand40mAatmax.
 Operatingindication ……“H”inHImodeor“L”inLOmodeatONoutput.
⑻Operatingtemperature……0〜50℃
        humidity…35〜85%RH,nosweatingallowed.
⑼Storagetemperature ……−20〜70℃,withlowerhumiditythan65%RH.
⑽Netweight…………………Netweight,paneltype:Around130g.
            stand-alonetype:Around330g.
⑾Pressureport

……………Pressureport,paneltype:M50.8pitch.
            stand-alonetype:R1/4(PT1/4).
⑿Attachments………………Halfunionfor6-mmODtube.
            Valuejointfor6-mmOD,4-mmIDtube,paneltype.
⒀Options(seeTable2)……
a.Internalbattery
Type…Lithiumbattery,ER6VM.
Serviceabletime…Oneyear(9000hours),continuouslyoperable.
        HasabatterychangeindicatorBATT.
b.Externalpowersource
Inputvoltage…5〜10or10〜24Vdc(seeTable2).
Currentconsumption…Lessthan20mA.
c.Analogvoltageoutput
Outputvoltage…0〜1V,notisolated.
Accuracy…±5%F.S.,whichisaddedtomainaccuracy.
Loadresistance…Higherthan1kohm.
Seriesname Series(Table1)
Type(Table2)
PG−200−    −
§
3. Specification
*Measurementcanbemadeupto“−760mmHg”for102VHandupto“760mmHg”for102AH
(Accuracynotguaranteedbeyondtheratedpressure.).
101G
101GP
102G
102GP
102VP
102VH
102AP
102AH
103G
103GP
103GMP
mmH2O
kPa
kgf/cm2
kPa
kPa
mmHg
kPaabs
mmHgabs
kgf/cm2
kPa
MPa
1
0.01
0.001
0.1
0.1
1
0.1
1
0.01
1
0.001
5000
50
5
500
500
3678
500
3678
20
2000
2.0
5000
20
2
200
200
1471
200
1471
15
1500
1.5
0〜1000
0〜10.00
0〜1.000
0〜100.0
0〜−100.0
0〜−735
0〜100.0
0〜735
0〜10.00
0〜1000
0〜1.000
*
*
*See§5TerminalWiring
PRESSURERANGE
MAX
PRESSURE
Break-down
Pressure
RESOLUTION
UNITSERIES
Table1
*
Panel
Stand
−P
−1−P
−3−P
−S
−1−S
−3−S
HI、LO
HI、LO
HI
HI、LO
HI、LO
HI、LO
−
−
Voltage
−
−
Voltage
Internallithiumbattery
External5〜24Vdc
Sameasabove
Internallithiumbattery
External5〜24Vdc
Sameasabove
Table2
TYPE POWERSOURCE
SWITCH
OUTPUT
OPTIONAL
OUTPUT
*
3
Switchoutputofnpnopencollectortypewith30Vdcand40mAatmaximum.
§
6. OutputType
[Stand-alonetype]
[Paneltype] [Stand-alonetype]
  ProceedonthePCboadinsidethemainbody.
The external power models have
powervoltageof10-24Vdcsetat
default.TooperateyourPressure
Gauge with 5-10 Vdc, change the
internalterminalblockwiring.
Select one of the terminal blocks for connection depending on the power
voltage.Donotapplyanyvoltageexceedingthevoltage range.Foroutput
wiring,usethinnerwirethanAWG26.
Theeachcommonofexternalpowerterminalandvoltageoutputterminal
areconnectedtotheinternalcircuit.
[Paneltype]
⑴Mountingontopanel
 Cutaholeoutasshowninthepanelcutdrawingabove.Forciblyputthe
mainbodyintothecuthole.Thehookwillfixthemainbodytothepanel.
⑵Removingoutofpanel
 Drawthemainbodyoutofthepanelwhilenippingthehookbetweenyour
thumbandmiddlefingers.
§
4. ExterminalDimensions tolerance(±0.5mm)
§
5. TerminalWiring
−
72
40
69.5 +0.5
0
68.5 +0.5
0
Unitofdisplay
Pressureport
M5,depth5
Panelcut
Panelthickness
(1〜2.5mm)
Panelmontnghook
13
72
72
40
13.5
R1/4
(PT1/4)
M5(P=0.8)depth6
Unitofdisplay
11.5
7222
13.5
28.5
Terminalblockof6pins
Atdefault
Black Red
Battery
(−P)
Exterminalpower
(−3−P)
1
SwitchoutputHI
Voltageoutput
SwitchoutputLO
SwitchoutputHI
Powersource
23456
Exterminalpower
(−1−P)
SwitchoutputHI SwitchoutputLO
Powersource
・COM.
・SW.OUTHI
・COM.
・SW.OUTLO
・5〜10V
・COM.
・10〜24V
・COM.
・Outputvoltage
Externalpowermodels
}
+
−
−
−
−
+
+
+−+−
+−+−+−
+−+−+−
Powersource(+)
Power(−)source
Transistorprotectivediode
BC
E−
+
Exampleofrelay
connection
5〜10V 10〜24V
−
COM.
4
⑴MakewiringbyfollowingSection5,“TerminalWiring.”
⑵TurnthePOWERswitchon.Fortheexternalpowertype,supplytoitthepowerindicatedonthenameplate.
⑶Checktoinsurethatthepressureindicationiszerowithnopressureapplied.Thezeroindicationmaybechangedslightlywithpostureofthemainbody.Ifthe
indicationisover5counts,makezeroadjustmentwiththeZEROadjustingtrimmer.
⑷MakeHIandLOsettingswiththeSETswitchandHIandLOsettingtrimmers(seeSection7,step5).
⑸ApplyapressuretothePressureGauge.Thenitwillindicatethemeasuredvalue.
⑹Iftheswitchoutputison,thePressureGaugewillshow“L”or“H”.
CopalElectronicswarrantstheproductfortheperiodofoneyearafterthedateofthecustomerʼsreceipt.Wewillrepairthetroubledproductscausedbyour
improperdesigningand/orproductioncontrolatourcost.Ourwarrantyislimitedtotheproductsonly,notonanotherdamagethatiscausedbytheproduct
malfunction.
Thefollowingdamage/replacementarerepaired/takenatthecustomerʼscharge;
 ⑴Failureordamagecausedbyunsuitableorwrongusage,modificationorrepairbythecustomer.
 ⑵FailureordamagecausedbydisasteroranActofGod.
 ⑶Replacementofattachments(HalfUnionandBarbJoint).
§
8. Howtouse
§
9. WARRANTY
⑴Frontpanelcontrols
⑵Descriptionofthefeatures
1.
2.
3.
4.
5.
6.
7.
8.
9.
Pressureindicator
Polarityindicator
Pressureport
POWERswitch
SETswitch
HIsettingtrimmer
LOsettingtrimmer
SPANadjustingtrimmer
ZEROadjustingtrimmer
Showsapressurevalueenteredtothepressureport.Alsoshowsasetvaluegivenwiththesetswitch.
Showsthenegative(−)uponnegativepressure.
Hasapressureapplied.
TurnsonoroffthepowertothePressureGauge.
SelectsamodetocheckaHIorLOsetvalue.IfyoupresstheSETswitchonce,theindicationwillbeautomaticallychangedinthe
sequenceshownbelow.TochecktheLOsetvalue,waitforaround20secondsafterpressingtheSETswitch.
Ifsettingendsortointerruptsettinginthecourse,presstheSETswitchagain.Thenthepressurewillbeindicated.
UsedtoadjustpressuretotheHIsetvaluethatisindicatedwiththeSETswitch.
UsedtoadjustpressuretotheLOsetvaluethatisindicatedaftertheHIsettingtimehaselapsed.
Usedtoadjustthesensitivitysothatthepressurecanindicatethefullscalewiththeratedpressureappliedtothepressureport.
Asthetrimmeriscalibrated,itissealedup.
Usedtoadjustthesensortozero.Thepressureindicationshouldbeadjustedto“000”withnopressureapplied.
§
7. FrontPanelControlsandFeatures
Frontcontrols
Pressureindicator
Batterychange
indicator
Polarityindicator
Switchingindicator
Decimalpoint
SETswitch LOsetting
trimmer
HIsetting
trimmer
POWERswitch SPANadjusting
trimmer
ZEROadjusting
trimmer
Indicationmode
Settingmode
Around20sec Around20sec
NO
YES
SET
Pressure
indicaton HIsetting LOsetting

Other Nidec Measuring Instrument manuals

Nidec MT-100 Installation manual

Nidec

Nidec MT-100 Installation manual

Nidec TNP Series User manual

Nidec

Nidec TNP Series User manual

Nidec PG-35 User manual

Nidec

Nidec PG-35 User manual

Nidec FG-3000R Series User manual

Nidec

Nidec FG-3000R Series User manual

Nidec DT-200LR-S12 User manual

Nidec

Nidec DT-200LR-S12 User manual

Nidec DT-361 User manual

Nidec

Nidec DT-361 User manual

Nidec FGE-HXY Installation manual

Nidec

Nidec FGE-HXY Installation manual

Nidec FG-7000TA User manual

Nidec

Nidec FG-7000TA User manual

Nidec FG-3000R-S User manual

Nidec

Nidec FG-3000R-S User manual

Nidec TNP Series User manual

Nidec

Nidec TNP Series User manual

Nidec Shimpo DT-5TS User manual

Nidec

Nidec Shimpo DT-5TS User manual

Nidec DT-501X User manual

Nidec

Nidec DT-501X User manual

Nidec TNX Series User manual

Nidec

Nidec TNX Series User manual

Nidec DT-361 User manual

Nidec

Nidec DT-361 User manual

Nidec FG -3000 Series User manual

Nidec

Nidec FG -3000 Series User manual

Nidec TNP-0.5 User manual

Nidec

Nidec TNP-0.5 User manual

Nidec ST-1000 Installation manual

Nidec

Nidec ST-1000 Installation manual

Nidec ST-1100 User manual

Nidec

Nidec ST-1100 User manual

Nidec FG-7000T User manual

Nidec

Nidec FG-7000T User manual

Nidec ST-1100 User manual

Nidec

Nidec ST-1100 User manual

Nidec FGV-HXY User manual

Nidec

Nidec FGV-HXY User manual

Nidec ST-1100 User manual

Nidec

Nidec ST-1100 User manual

Nidec PG-100N Series User manual

Nidec

Nidec PG-100N Series User manual

Nidec SHIMPO DT-5TXR User manual

Nidec

Nidec SHIMPO DT-5TXR User manual

Popular Measuring Instrument manuals by other brands

Anritsu MT8852B Operation manual

Anritsu

Anritsu MT8852B Operation manual

Burkert 8640 quick start

Burkert

Burkert 8640 quick start

Bosch Professional GLM 50-25 G Original instructions

Bosch

Bosch Professional GLM 50-25 G Original instructions

Salutron HardyTest D400 user manual

Salutron

Salutron HardyTest D400 user manual

GW Instek GSP-730 user manual

GW Instek

GW Instek GSP-730 user manual

Sony TC-377 Service manual

Sony

Sony TC-377 Service manual

Shodex C18U 2B Operation manual

Shodex

Shodex C18U 2B Operation manual

Sper scientific 850020 instruction manual

Sper scientific

Sper scientific 850020 instruction manual

Badger Meter Dynasonics DXN Series Firmware update manual

Badger Meter

Badger Meter Dynasonics DXN Series Firmware update manual

Johnson Controls NAE-S installation guide

Johnson Controls

Johnson Controls NAE-S installation guide

GeoSIG GMS-scai Faq

GeoSIG

GeoSIG GMS-scai Faq

GARANT 363000 user guide

GARANT

GARANT 363000 user guide

Morris 57088 user manual

Morris

Morris 57088 user manual

Viavi 3550 Getting started manual

Viavi

Viavi 3550 Getting started manual

Hanna Instruments HI97716 instruction manual

Hanna Instruments

Hanna Instruments HI97716 instruction manual

NVision 30100VA owner's manual

NVision

NVision 30100VA owner's manual

Agilent Technologies FieldFox N9912A Service note

Agilent Technologies

Agilent Technologies FieldFox N9912A Service note

GASTRON GIR-3000 instruction manual

GASTRON

GASTRON GIR-3000 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.