DIGITALPRESSUREGAUGE
INSTRUCTION MANUALVer.7.1
PG-200
1
Nishi-ShinjukuPrimeSquare.,7-5-25
Nishi-ShinjukuShinjuku-kuTokyo160-0023,Japan
https://www.nidec-copal-electronics.com
Formoredetailedinformationpleaseaskforthe
nearestdistributororthefollowingsalescenter.
YouaregreatlyappreciatedforpurchasingCopal'sModel
PG−200 digital Pressure Gauge. You should read this
instructionmanualthoroughlytooperatethePG−200in
optimumstate.
CAUTION Thiscautionmarkdescribeswhenthereisapossibilitythatusermaysufferfromdamageorphysical
damagemayoccuriftheproductisusedimproperly.
CAUTION
⑴Theproduct,whichisaprecisioninstrument,mustbetakenspecialcarenottobedamagedbyimpactnorbybeingdroppedwhenitistrasportedandinstorage.
⑵Theproductmustbeavoidedinstoragewhereisdusty,drippingandvibrated.
⑴Mountingtheattachmentforpaneltype
 Iffightenigtheattachmenttothepressureport,thetighteningtorqueshouldbearound1N・m.
⑵Pipingforstand-alonetype
 Forpiping,usethehexagonalportionofthepressureportfordriving.
⑶Mediatobeused
 ThePressureGaugeshouldbeusedforfluidsthatcannotcorrodethediaphragmofSUS316L,pressureportofSUS316andO-ringoffluororubber.
⑷Excessivepressure
 The pressure to be measured is within the specified range. Measurement of a higher pressure than the maximum allowable one may cause performance
degradationordestruction.
⑸Internalbattery
①ReplacebatterywithToshibaBatteryCo.,Ltd./ERVM3.6V/lithiumbatteryonly.Useofanotherbatterymaypresentariskoffireorexplosion.Ifyouneed
replacebattery,pleaseplaceanorderwithus.
②When“LOBAT”signisdisplayed,thebatteryshouldbereplaced.
③Thebatteryusedinthisdevicemaypresentriskoffireofchemicalburnifmistreated.Donotrecharge,disassemble,heatabove100℃(212°F),orincinerate.
④Disposeofusedbatterypromptly.Keepawayfromchildren.Donotdisassembleanddonotdisposeofinfire.
⑹Maintenance
 IfthePressureGaugegetsdirty,wipeitoffwithhardlysqueezedclothcontaininganeutraldetergent.Donotuseanythinnerandbenzine.
⑺Protectionagainstnoises
①NoiseshavingmixedintheswitchoutputorpowerlinemaycausethePressureGaugetochangethepressureindication,malfunctionorbebroken.
 TakesomemeasuretoputthePressureGaugeawayfrompowerlineoruseshieldedwire.ItiseffectivetogroundthePressureGauge.
②Ifthe switchoutputhasaninductionloadsuch asrelayorsolenoidconnectedtoit, itshouldhaveasurgeabsorbercircuit putinit.Therelaycontacts
shouldhaveacontactpreventivecircuitputinittopreventnoisesfrombeinggenerated.
⑻Prohibitionofshort-circuitingtheswitchterminals
 Donotshort-circuittheswitchoutputterminaltoanypowerterminal.Theinternalcircuitmaybebroken.
§
1. HandlingNote
§
2. TRANSPORTATION&STORAGE
2
⑴Model
⑵Measurement………………Gaugepressure.(102AP/102AH:absolute)
⑶Indication…………………3-1/2digits,000〜1999Max,digitalLCDdisplay.
⑷Indication…………………Around3times/sec.
⑸Accuracy …………………±0.5%F.S.±2digit(at25℃±5℃)
⑹Temperaturecharacteristics
 atzeropoint;±0.05%F.S./℃±2digit(102G/102GP/102VP/102VH/103G/103GP/103GMP)
       ±0.1%F.S./℃ ±2digit(101G/101GP/102AP/102AH)
 inSPAN  ;±0.05%Reading/℃ ±2digit
⑺Switchingfeatures
 Numberofsetpoints ……Two,HIandLO,activatidatupperlimit.
 Setrangedivisions………000〜1000,HIandLO.
 Settingmethod……………WithtrimmereachforHIandLO.Setvalueindicationcanbemadetotimewithsettingswitch.
 Operatingaccuracy ………Within±3divisionsfromindicationvalue.
 Difference…………………Within4divisions,fixed.
 Outputsystem……………NPNopencollectorof30Vdcand40mAatmax.
 Operatingindication ……“H”inHImodeor“L”inLOmodeatONoutput.
⑻Operatingtemperature……0〜50℃
        humidity…35〜85%RH,nosweatingallowed.
⑼Storagetemperature ……−20〜70℃,withlowerhumiditythan65%RH.
⑽Netweight…………………Netweight,paneltype:Around130g.
            stand-alonetype:Around330g.
⑾Pressureport

……………Pressureport,paneltype:M50.8pitch.
            stand-alonetype:R1/4(PT1/4).
⑿Attachments………………Halfunionfor6-mmODtube.
            Valuejointfor6-mmOD,4-mmIDtube,paneltype.
⒀Options(seeTable2)……
a.Internalbattery
Type…Lithiumbattery,ER6VM.
Serviceabletime…Oneyear(9000hours),continuouslyoperable.
        HasabatterychangeindicatorBATT.
b.Externalpowersource
Inputvoltage…5〜10or10〜24Vdc(seeTable2).
Currentconsumption…Lessthan20mA.
c.Analogvoltageoutput
Outputvoltage…0〜1V,notisolated.
Accuracy…±5%F.S.,whichisaddedtomainaccuracy.
Loadresistance…Higherthan1kohm.
Seriesname Series(Table1)
Type(Table2)
PG−200−    −
§
3. Specification
*Measurementcanbemadeupto“−760mmHg”for102VHandupto“760mmHg”for102AH
(Accuracynotguaranteedbeyondtheratedpressure.).
101G
101GP
102G
102GP
102VP
102VH
102AP
102AH
103G
103GP
103GMP
mmH2O
kPa
kgf/cm2
kPa
kPa
mmHg
kPaabs
mmHgabs
kgf/cm2
kPa
MPa
1
0.01
0.001
0.1
0.1
1
0.1
1
0.01
1
0.001
5000
50
5
500
500
3678
500
3678
20
2000
2.0
5000
20
2
200
200
1471
200
1471
15
1500
1.5
0〜1000
0〜10.00
0〜1.000
0〜100.0
0〜−100.0
0〜−735
0〜100.0
0〜735
0〜10.00
0〜1000
0〜1.000
*
*
*See§5TerminalWiring
PRESSURERANGE
MAX
PRESSURE
Break-down
Pressure
RESOLUTION
UNITSERIES
Table1
*
Panel
Stand
−P
−1−P
−3−P
−S
−1−S
−3−S
HI、LO
HI、LO
HI
HI、LO
HI、LO
HI、LO
−
−
Voltage
−
−
Voltage
Internallithiumbattery
External5〜24Vdc
Sameasabove
Internallithiumbattery
External5〜24Vdc
Sameasabove
Table2
TYPE POWERSOURCE
SWITCH
OUTPUT
OPTIONAL
OUTPUT
*
3
Switchoutputofnpnopencollectortypewith30Vdcand40mAatmaximum.
§
6. OutputType
[Stand-alonetype]
[Paneltype] [Stand-alonetype]
  ProceedonthePCboadinsidethemainbody.
The external power models have
powervoltageof10-24Vdcsetat
default.TooperateyourPressure
Gauge with 5-10 Vdc, change the
internalterminalblockwiring.
Select one of the terminal blocks for connection depending on the power
voltage.Donotapplyanyvoltageexceedingthevoltage range.Foroutput
wiring,usethinnerwirethanAWG26.
Theeachcommonofexternalpowerterminalandvoltageoutputterminal
areconnectedtotheinternalcircuit.
[Paneltype]
⑴Mountingontopanel
 Cutaholeoutasshowninthepanelcutdrawingabove.Forciblyputthe
mainbodyintothecuthole.Thehookwillfixthemainbodytothepanel.
⑵Removingoutofpanel
 Drawthemainbodyoutofthepanelwhilenippingthehookbetweenyour
thumbandmiddlefingers.
§
4. ExterminalDimensions tolerance(±0.5mm)
§
5. TerminalWiring
−
72
40
69.5 +0.5
0
68.5 +0.5
0
Unitofdisplay
Pressureport
M5,depth5
Panelcut
Panelthickness
(1〜2.5mm)
Panelmontnghook
13
72
72
40
13.5
R1/4
(PT1/4)
M5(P=0.8)depth6
Unitofdisplay
11.5
7222
13.5
28.5
Terminalblockof6pins
Atdefault
Black Red
Battery
(−P)
Exterminalpower
(−3−P)
1
SwitchoutputHI
Voltageoutput
SwitchoutputLO
SwitchoutputHI
Powersource
23456
Exterminalpower
(−1−P)
SwitchoutputHI SwitchoutputLO
Powersource
・COM.
・SW.OUTHI
・COM.
・SW.OUTLO
・5〜10V
・COM.
・10〜24V
・COM.
・Outputvoltage
Externalpowermodels
}
+
−
−
−
−
+
+
+−+−
+−+−+−
+−+−+−
Powersource(+)
Power(−)source
Transistorprotectivediode
BC
E−
+
Exampleofrelay
connection
5〜10V 10〜24V
−
COM.
4
⑴MakewiringbyfollowingSection5,“TerminalWiring.”
⑵TurnthePOWERswitchon.Fortheexternalpowertype,supplytoitthepowerindicatedonthenameplate.
⑶Checktoinsurethatthepressureindicationiszerowithnopressureapplied.Thezeroindicationmaybechangedslightlywithpostureofthemainbody.Ifthe
indicationisover5counts,makezeroadjustmentwiththeZEROadjustingtrimmer.
⑷MakeHIandLOsettingswiththeSETswitchandHIandLOsettingtrimmers(seeSection7,step5).
⑸ApplyapressuretothePressureGauge.Thenitwillindicatethemeasuredvalue.
⑹Iftheswitchoutputison,thePressureGaugewillshow“L”or“H”.
CopalElectronicswarrantstheproductfortheperiodofoneyearafterthedateofthecustomerʼsreceipt.Wewillrepairthetroubledproductscausedbyour
improperdesigningand/orproductioncontrolatourcost.Ourwarrantyislimitedtotheproductsonly,notonanotherdamagethatiscausedbytheproduct
malfunction.
Thefollowingdamage/replacementarerepaired/takenatthecustomerʼscharge;
 ⑴Failureordamagecausedbyunsuitableorwrongusage,modificationorrepairbythecustomer.
 ⑵FailureordamagecausedbydisasteroranActofGod.
 ⑶Replacementofattachments(HalfUnionandBarbJoint).
§
8. Howtouse
§
9. WARRANTY
⑴Frontpanelcontrols
⑵Descriptionofthefeatures
1.
2.
3.
4.
5.
6.
7.
8.
9.
Pressureindicator
Polarityindicator
Pressureport
POWERswitch
SETswitch
HIsettingtrimmer
LOsettingtrimmer
SPANadjustingtrimmer
ZEROadjustingtrimmer
Showsapressurevalueenteredtothepressureport.Alsoshowsasetvaluegivenwiththesetswitch.
Showsthenegative(−)uponnegativepressure.
Hasapressureapplied.
TurnsonoroffthepowertothePressureGauge.
SelectsamodetocheckaHIorLOsetvalue.IfyoupresstheSETswitchonce,theindicationwillbeautomaticallychangedinthe
sequenceshownbelow.TochecktheLOsetvalue,waitforaround20secondsafterpressingtheSETswitch.
Ifsettingendsortointerruptsettinginthecourse,presstheSETswitchagain.Thenthepressurewillbeindicated.
UsedtoadjustpressuretotheHIsetvaluethatisindicatedwiththeSETswitch.
UsedtoadjustpressuretotheLOsetvaluethatisindicatedaftertheHIsettingtimehaselapsed.
Usedtoadjustthesensitivitysothatthepressurecanindicatethefullscalewiththeratedpressureappliedtothepressureport.
Asthetrimmeriscalibrated,itissealedup.
Usedtoadjustthesensortozero.Thepressureindicationshouldbeadjustedto“000”withnopressureapplied.
§
7. FrontPanelControlsandFeatures
Frontcontrols
Pressureindicator
Batterychange
indicator
Polarityindicator
Switchingindicator
Decimalpoint
SETswitch LOsetting
trimmer
HIsetting
trimmer
POWERswitch SPANadjusting
trimmer
ZEROadjusting
trimmer
Indicationmode
Settingmode
Around20sec Around20sec
NO
YES
SET
Pressure
indicaton HIsetting LOsetting

Other Nidec Measuring Instrument manuals

Nidec ST-1100 User manual

Nidec

Nidec ST-1100 User manual

Nidec SHIMPO DT-5TXR User manual

Nidec

Nidec SHIMPO DT-5TXR User manual

Nidec DT-361 User manual

Nidec

Nidec DT-361 User manual

Nidec FG -3000 Series User manual

Nidec

Nidec FG -3000 Series User manual

Nidec FG-3000R-S User manual

Nidec

Nidec FG-3000R-S User manual

Nidec DT-105A Installation manual

Nidec

Nidec DT-105A Installation manual

Nidec TNP Series User manual

Nidec

Nidec TNP Series User manual

Nidec TNX Series User manual

Nidec

Nidec TNX Series User manual

Nidec DT-205LR User manual

Nidec

Nidec DT-205LR User manual

Nidec Shimpo FG-L1 User manual

Nidec

Nidec Shimpo FG-L1 User manual

Nidec PT-120 User manual

Nidec

Nidec PT-120 User manual

Nidec DT-501X User manual

Nidec

Nidec DT-501X User manual

Nidec PG-100B Series User manual

Nidec

Nidec PG-100B Series User manual

Nidec Kato Engineering KRM2000 User manual

Nidec

Nidec Kato Engineering KRM2000 User manual

Nidec FG-3000R Series User manual

Nidec

Nidec FG-3000R Series User manual

Nidec ST-1100 User manual

Nidec

Nidec ST-1100 User manual

Nidec TNP-0.5 User manual

Nidec

Nidec TNP-0.5 User manual

Nidec PG-35H Series User manual

Nidec

Nidec PG-35H Series User manual

Nidec Shimpo MT-200 User manual

Nidec

Nidec Shimpo MT-200 User manual

Nidec MFD-02 User manual

Nidec

Nidec MFD-02 User manual

Nidec MF-2 User manual

Nidec

Nidec MF-2 User manual

Nidec ST-1000 Installation manual

Nidec

Nidec ST-1000 Installation manual

Nidec PG-100 User manual

Nidec

Nidec PG-100 User manual

Nidec MT-100 Installation manual

Nidec

Nidec MT-100 Installation manual

Popular Measuring Instrument manuals by other brands

Grandway OFI-3 user guide

Grandway

Grandway OFI-3 user guide

Hanna Instruments HI 4015 instruction manual

Hanna Instruments

Hanna Instruments HI 4015 instruction manual

Emerson FB1200 use instructions

Emerson

Emerson FB1200 use instructions

Endress+Hauser Proline Promag 51 operating instructions

Endress+Hauser

Endress+Hauser Proline Promag 51 operating instructions

GW Instek GRF-1300 user manual

GW Instek

GW Instek GRF-1300 user manual

biochrom HB Ultrospec 7500 user manual

biochrom

biochrom HB Ultrospec 7500 user manual

COMED 44 447 80 instruction manual

COMED

COMED 44 447 80 instruction manual

Advanced Fiber Solutions AF-DR-515 user guide

Advanced Fiber Solutions

Advanced Fiber Solutions AF-DR-515 user guide

Trotec LD6000 PTS Original instructions

Trotec

Trotec LD6000 PTS Original instructions

Delmhorst Instrument Co BD-2100 owner's manual

Delmhorst Instrument Co

Delmhorst Instrument Co BD-2100 owner's manual

Endress+Hauser Liquiphant M FTL51C user manual

Endress+Hauser

Endress+Hauser Liquiphant M FTL51C user manual

RND 365-00002 user manual

RND

RND 365-00002 user manual

GREISINGER BaleCheck 200 operating manual

GREISINGER

GREISINGER BaleCheck 200 operating manual

Tru-Test Speedrite Fault Finder quick start guide

Tru-Test

Tru-Test Speedrite Fault Finder quick start guide

Bell and Howell 770 manual

Bell and Howell

Bell and Howell 770 manual

Rane RA 27 Operator's manual

Rane

Rane RA 27 Operator's manual

Keysight Technologies M981 AS Series quick start guide

Keysight Technologies

Keysight Technologies M981 AS Series quick start guide

Tektronix RSA5100A Series Service manual

Tektronix

Tektronix RSA5100A Series Service manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.