V
During use
CAUTION
• Before use, perform visual and operation checks. If abnormal conditions are
encountered, stop using the device.
If the device is used under abnormal conditions, intended results may not occur. Also
unexpected malfunctions or health hazards may occur due to improper measurement.
• Before and after use of the device, and before treating each patient, clean the patient’s
contact area (chinrest and forehead rest) with clean absorbent cotton or gauze
dampened with rubbing alcohol.
If chinrest paper is used, remove one piece for each patient.
For severe stains, wipe the area not with a dry cloth but with gauze dampened with alcohol.
• Take care not to catch hands or fingers in moving parts (measuring unit, main body,
and chinrest). Pay particular attention to the measuring unit as it moves in each
direction during auto alignment. Be sure to give this caution to patients.
Hands or fingers may be pinched and may result in injury.
• Keep the measuring window free of fingerprints and dust. Also confirm that it is not
dirty before use.
The measurement accuracy may decrease substantially.
• In the event of smoke or strange odors, immediately turn off the device and
disconnect the power plug from the outlet. After you are sure that the smoke has
stopped, then contact NIDEK or your authorized distributor.
Usage of the device under such abnormal conditions may cause fire or electric shock. In
case of fire, use a dry chemical (ABC) extinguisher to extinguish the fire.
• Before measurement, explain the measurement purpose and method sufficiently to
patients.
• Instruct the patient to see the picture of a balloon with their eyes wide open. Start the
measurement after confirming that the instruction is properly followed by the patient.
Be careful not to perform measurement while the device is misaligned to the patient’s
eye.
Proper measurement may not be performed.
• After measurement, instruct the patient not to hold the chinrest when the patient is
released from the device.
The device may topple over resulting in injury.
• Immediately replace the power cord if the internal wires are exposed, the device turns
on or off when the power cord is moved, or the cord and/or plug are too hot to be held
with hands.
This may result in electric shock or fire.
In the event of malfunction, disconnect the power cord from the wall outlet. Never touch
the inside of the device and contact NIDEK or your authorized distributor.
• Never press on the LCD with a hard object such as a ball-point pen. Keep magnetic
objects away from the LCD.
The device may be damaged.