TRANSFERRING THE SAVED DATA
¥Install the NISSEI HealStyle App from the Google Play Store or
Apple App Store to your smartphone, then start the App.
• Compatibledevices:
–iPod/iPhone/iPaddevice:iPhone4SoriPodtouch(5thGeneration)or
laterwithiOS8orlater
–Androiddevice:Android4.3deviceorlaterequippedwithBluetooth4.0
orlater.
• Performtheuserregistrationbeforehand.
øTransfer the saved data.
Touch the Blood Pressure Monitor icon on the App screen.
Press and hold the Bluetooth connection button ( ) on the main unit
for about 3 seconds.
TheBluetoothmarkstartsflashingandtheunitis
switchedtotheconnectionmode.
Touch the reception button on the upper right on
the App screen, and register the ID for connection
displayed on the unit.
Thedatacommunicationstarts.
• FordetailsaboutoperationsoftheApp,visit:<http://
www.nissei-kk.co.jp>.
• OncetheunitisconnectedwiththeNISSEIHealStyleApp,theclockoftheunitisautomatically
synchronizedwiththeconnectedsmartphone.
• IftheBluetoothconnectioncannotbeestablished,turnofftheunitbypressingtheStart/Stop
button( ),thentryagain.
Do not remove the batteries from the unit or disconnect the AC adapter while transferring the
data.
TROUBLESHOOTING
Bloodpressureisextremelyhighorlow.
• Themainunitisnotadjustedtoyourheart.Adjust the main unit to the height of your
heart.
• Measurementisnottakenwiththecorrectpostureorthecuffiswrappedincorrectly.
Reconfirm the measurement procedures.
• Thereadingwaseffectedbymovingortalking.Remain still and quiet during
measurement.
Measuredvaluesvaryallthetime.
Mentalandphysicalconditionsormeasurementconditionsareinfluencingbloodpressure.
Make measurement under the same conditions.
Measuredvalueisdifferentfromthattakenatahospital.
Mentalconditionssuchasnervousnessatahospitalorfeelingrelaxedathomeare
influencingbloodpressure.Take records of blood pressure taken at home and consult
with your doctor.
Bloodpressureischanging24hoursadayinrelationwithmentalandphysical
conditions.Eating,drinking,smoking,exercisingorbathingwillalterbloodpressure.
Bloodpressurewillbealsoinfluencedbymentalconditionssuchasfeelingtenseor
relievedandhealthconditions.Itisimportanttoknowthetendencyofbloodpressureby
makingmeasurementregularly.Makeyourownrulesincludingconditionsandtimeto
makemeasurementandtakebloodpressureeveryday.
Inflationisrepeated.
Thecuffisinflatedagainifasuddenchangeofpressure,whichcouldbeduetomovement
orstrainingofthearmorwrist,wasdetected.Inflationisrepeateduntilbloodpressureis
taken.Repeated inflation is not a malfunction of the unit. Do not move or speak during
measurement.
[Err-1]or[Err-3]isdisplayed.
• Bloodpressurecouldnotbetakenduetomovingorspeaking.Do not move or speak
during measurement.
• Theresultofthemeasurementisoutsideofthemeasurablerange.If [Err-1] or [Err-3] is
displayed for each time you measure the blood pressure, consult with your doctor.
[Err-2]isdisplayed.
• Theairhoseisbentorcrushed.Check the air hose.
• Thecuffisnotsecurelyconnectedtothemainunit.Secure the air connector.
• Thecuffisnotwrappedappropriately.Reconfirm how to put the cuff on your arm.
• Thereadingwaseffectedbymovingortalking.Remain still and quiet during
measurement.
[Err-300]isdisplayed.
Overpressure:bloodpressurecouldnotbetakenduetomovingorspeakingalthoughthe
cuffwasinflatedtothemaximumpressure.Do not move or speak during measurement.
Nothingisdisplayed.
• TheACadaptorisnotconnected.Connect the AC adaptor.
• Thebatteriesaredepleted.Replace all batteries with new ones.
• Thebatteriesareinsertedincorrectly.Reinsert the batteries correctly.
• Thebatteryterminalsarenotclean.Clean the terminals with a dry cloth.
Clockisnotdisplayed.
Theclockisnotactivated.Adjust the date and time and activate the clock.
• NOTE:Theclockisdeactivatedwhenthebatteriesand/orACadaptorare/isremoved.
Measurementdateandtimearedisplayedas“- - / - -”and“- - : - -”.
Theclockisnotactivated.Adjust the date and time and activate the clock.
Measurementwastakenbeforetheclockwasactivated.The measurement date and time
cannot be saved without the clock being activated.
[00]isdisplayed.
TheStart/Stopbutton( )wasbeingpressedwhenthebatterieswerebeinginstalled
orwhenACadaptorwasbeingpluggedin.Turn off the unit once with the Start/Stop
button ( ).
Ifyoucannotgetacorrectmeasurementwiththemethodsabove,contactyourdealer.
Donotdisassembleortamperwiththeinternalmechanism.
PRODUCT SPECIFICATIONS
Model : DS-S10
Operatingprinciple : Oscillometricmethod
Indicator : 15-digitliquidcrystaldisplay
Pressureindicatingrange : 3to300mmHg(cuffpressure)
Measuringrange : 50to250mmHg(systolic),40to180mmHg(diastolic),
40to160bpm(pulserate)
Accuracy* : ±3mmHg(cuffpressure),±5%ofreading(pulserate)
Inflation : Automaticinflation
Deflation : Automatic(electriccontrolvalve)
Exhaust : Automaticexhaustvalve
Powersupply : Four1.5voltLR6(AAalkaline)batteriesorACadaptor
ADP-W5series
Powerconsumption : 4W(max.)
Electricrating : DC6V/4W,withfourLR6batteries
  Adaptor;AC100–240V,50/60Hz,0.12A,
  Unit;DC6V,500mA,withdesignatedACadaptor
Memory : M1/M2;2banks,eachstores60readings
  ID(No.1toNo.5);5banks,eachstores20readings
Bluetoothstandard : BluetoothLowEnergy4.1
Operatingconditions : +10˚Cto+40˚C,30%to85%RH(noncondensing)
Transportation/storageconditions : –20˚Cto+60˚C,10%to95%RH(noncondensing)
Cuff : Coveragearmcircumference;22to42cm,appliedpart;
BF
Mainunit : Weight:Approx.331g(withoutbatteries)
  Size:162.3x127.3x96mm(WxDxH)
Protectionagainstharmfulingressofwater: IP20
Protectionagainstelectricshock : Internallypoweredequipment,TypeBFappliedpart(cuff)
Modeofoperation : Continuousoperation
Classification : Internallypoweredequipment
Keytosymbols : TypeBFappliedpart
 : Refertoinstructionmanual/booklet.
 : ClassIIequipment
Specificationsaresubjecttochangewithoutpriornotice.
ThisproductcomplieswithJIST1115(noninvasiveelectricbloodpressuremonitors)andEMC
(electromagneticcompatibility)StandardIEC60601-1-2:2007.(CISPRClassification:Group1,ClassB).
* TestprocedureisbasedonANSI/AAMISP10:2002,AmericanNationalStandardforelectronicor
automatedSphygmomanometers,andAmendment.
• iPod,iPhone,iPadaretrademarksofAppleInc.,registeredintheU.S.andothercountries.
• AndroidisatrademarkofGoogleInc.
• TheBluetooth®wordmarkandlogosare registeredtrademarksownedbyBluetoothSIG,Inc.and
anyuseofsuchmarksbyNIHONSEIMITSUSOKKICO.,LTD.Corporationisunderlicense.Other
trademarksandtradenamesarethoseoftheirrespectiveowners.
BLOOD PRESSURE MONITOR DS-S10
INSTRUCTIONS
ThismanualisintendedtoassistyouinthesafeandefficientoperationofBLOODPRESSUREMONITORDS-S10.Theproductmustbeusedinaccordancewiththeprocedurescontainedinthismanualand
mustnotbeusedforpurposesotherthanthosedescribedherein.Itisimportanttoreadandunderstandtheentiremanual.Inparticular,pleasereadcarefullyandbecomefamiliarwiththesectionentitled“TIPS
ONTAKINGYOURBLOODPRESSURE”.
CONTENTS
PARTNAMESANDPRODUCTCOMPONENTS................................................................... 1
GENERALINFORMATION..................................................................................................... 1
WARRANTY............................................................................................................................ 1
PRECAUTIONSANDCONTRAINDICATIONS....................................................................... 2
TIPSONTAKINGYOURBLOODPRESSURE...................................................................... 2
PREPARATIONBEFOREUSE............................................................................................... 2
MAKINGAMEASUREMENT.................................................................................................. 3
VIEWINGTHESAVEDREADINGS(MEMORYFUNCTION)................................................. 3
TRANSFERRINGTHESAVEDDATA.................................................................................... 4
TROUBLESHOOTING........................................................................................................... 4
PRODUCTSPECIFICATIONS................................................................................................ 4
PART NAMES AND PRODUCT COMPONENTS
CUFF POUCH INSTRUCTIONS AC ADAPTOR
MAIN UNIT AA (R6) BATTERIES ATTACHED DOCUMENT QUICK START GUIDE
AC CONNECTOR
AIR CONNECTOR
DISPLAY
START/STOP BUTTON
UP BUTTON
DOWN BUTTON
MEMORY BUTTON [ID]
MEMORY BUTTON [M1/M2]
MORNING/NIGHT MEMORY BUTTON
(BLUETOOTH CONNECTION BUTTON)
SET BUTTON
BATTERY
COMPARTMENT
AIR HOSE
AIR PLUG JAPANESE
Thebatteriesmaybe
shortlifeastheyare
fortestuse.
UseAA(LR6)batteries
fornormaluse. ENGLISH&CHINESE
GENERAL INFORMATION
INDICATIONS FOR USE
Thisproductisintendedfornoninvasivemeasurementofsystolicanddiastolicbloodpressure,
determinationofpulserateandcalculationofpulsepressureinadultsinahomehealthcareenvironment.
Theproductisnotdesignedforneonataluse.Pleaseconsultwithyourdoctororphysiciantousethis
producttotakethebloodpressureofachildorpersoninpregnancyorunderpre-eclampticcondition.
PULSE PRESSURE DISPLAY
Thisproductcalculatesanddisplayspulsepressure.
Whilesystolicbloodpressurekeepsincreasingwithage,diastolicbloodpressuretendstostart
decreasingataroundage50.Pulsepressureisavalueobtainedbysubtractingthediastolicvalue
fromthesystolicvalueandsopulsepressuretendstoincreasewithage.Pulsepressurehasbeen
consideredtoberelatedtostiffnessofarteryandhasbeenstudiedasacirculatoryriskfactor.Itis
sometimessaidthatapulsepressureof45mmHgisanormalvalue.Pulsepressureonlydoesnot
representarterialsclerosis.However,observationofpulsepressureinthelongtermwillbeimportant.
CARE AND MAINTENANCE
Keeptheproductclean.Inspectitscleanlinessafteruse.Toclean,useonlyasoftdrycloth.Donot
usegasoline,paintthinner,orotherstrongsolvents.Sincethecuffmayabsorbperspirationandother
fluids,inspectitforstainsanddiscolorationaftereachuse.Whencleaningthecuff,useasynthetic
detergentandgentlyrubthesurface.Airdrythoroughly.Makesurefluidnevergetsintheairhose.Do
notmachinewashorscrubit.
Whenstoringtheproduct,donotplaceheavyobjectsonit.Donotfoldorbendthecuffforcibly.To
disconnectthecufffromthemainunit,donotpulltheairhosebutholdtheairplugandunplugit.Donot
coiltheairhosetootightly.Whentheproducthasbeenstoredatatemperaturebelowfreezing,keepit
foratleast1hourinawarmplacebeforeusing.Removethebatteriesiftheproductistobestoredfor
anextendedperiodoftime.Keepthebatteriesoutofreachofchildren.
Wesuggestthatyouhaveyourbloodpressuremonitorcheckedevery2years.Thisoperationmayonly
beperformedbythemanufacturerorbyfirmsauthorizedbythemanufacturer.
METHOD OF MEASUREMENT
Thisproductemploystheoscillometricmethodformeasurementofbloodpressureandpulserate.The
cuffisconnectedtothemainunitandwrappedaroundthearm.Circuitswithinthecuffsensethesmall
oscillationsinpressureagainstthecuffproducedbytheexpansionandcontractionofthearteriesinthe
arminresponsetoeachheartbeat.Theamplitudeofeachpressurewaveismeasured,convertedto
millimetersofmercury,anddisplayedontheLCDasadigitalvalue.
FUZZY INFLATION
ThisproductemploysFUZZYinflationtoeasestresson
thearmduringcuffinflation.Bydetectingpulsesignals
whileinflating,thisproductisabletodeterminethe
sufficientpressureforeachmeasurement.
CUFF SYMBOL
Thisproductdisplayswhetherthecuffisappliedproperlyornotbyanalyzingthepressurewave.[ ]
indicatesthatthecuffisappliedproperly.Iftheindicationisnotdisplayed,thecuffmaybewrappedtoo
tightlyortooloosely.
RELIABILITY SYMBOL
Someoftheimportantaspectsinmeasuringbloodpressurearehowproperlythecuffisappliedand
howcalmyouareduringmeasurement.Theseaspectscanaffectmeasurementvaluesandsuchvalues
cannotsaidtobecorrectvalues.Thisproductshows[ ]whenthemeasurementissupposedly
madeingoodconditionwithoutinfluencesfromsuchaspects.
BODY MOTION SYMBOL
Bloodpressurevaluetakenwhilemovingcannotbesaidtobethecorrectvaluebecausebody
movementcanaffectbloodpressure.
Thisproductanalyzesthepulsewaveanddisplays[ ]whenbodymotionisdetected.
[ ]indicatestheresultsmightbeaffectedbybodymovement.
IRREGULAR PULSE RHYTHM SYMBOL
Pulserhythmcanbedisturbedbytalking,movingor
arrhythmias.Thisproductdisplays[ ]whenthe
differenceoftheshortestandlongesttimeintervals
betweenpulsewavesisover25%,indicatingirregular
pulserhythm.
MEMORY FUNCTION
Themeasuredvaluesareautomaticallysavedforlaterreviewinamemorybank:[M1]or[M2]tosave
thedataontheunit,and[ID](5banks;IDNo.1toNo.5)totransferthedatatoNISSEIHealStyleApp.
Thesememorybankscanbeusedtosavereadingsofseveralpersonsseparatelyortosavemorning
readingsandeveningreadingsseparately.
Youcansaveupto60readingseachon[M1]or[M2]bank,and20readingseachon[ID]bank(IDNo.1
toNo.5).Whenthenumberofstoredreadingsreachesitslimit,theoldestreadingwillbedeletedto
recordanewreading.
Savedreadingsarerecalledwiththemeasurementdateandtimewhentheclockfunctionisactivated.
(Theclockneedstobeactivatedbeforemeasurementforthedateandtimetobesavedwiththe
measuredvalued.)
[Err]resultsarenotsaved.
WARRANTY
Thisequipmentisguaranteedfortheperiodof1yearafterthedateofpurchaseagainstmanufacturingdefectswhenreturnedalongwiththeproofofdateofpurchasetothedealerfromwhomthepurchasewas
made.Duringthisperiod,theunitwillberepairedorreplacedfreeofchargeifthefailureisattributabletofaultydesignormanufacture.Thiswarrantydoesnotcoverdamageormalfunctionscausedbyimproper
handlingorusecontrarytotheinstructionsinthismanual.Pleasecontactyourdealerforadditionalwarrantyprovisionswhichmayremaineffectiveafterthemanufacturer’swarrantyperiodhasexpired.
Manufacturer:
NIHON SEIMITSU SOKKI CO., LTD.
2508-13NakagoShibukawaGunma377-0293Japan
websitehttp://www.nissei-jp.com
Regularpulserhythm
Anexampleofirregularpulserhythm
comparedtoregularpulserhythm
− 1 −− 4−
Press and hold
NISSEI
HealStyle
血圧計
ID FOR
CONNECTION
BLUETOOTH
MARK
受信
測定結果(ニックネーム1)
日付 時刻 最高 最低 脈拍
リスト グラフ プロフィール ID
受信
PRESSURE
TIME
INITIAL
PRESSURE
EN_DS-S10_IM.indd 1 2015/02/18 16:59
MAKING A MEASUREMENT
Inserttheairplugintotheairconnectorbefore
startingabloodpressuremeasurement.
• Thecuffisapplicabletoarmswithacircumference
between22and42cm.Takeyourarmsizebefore
measurement.
• Chooseyourmemorybankbeforemeasurement
tousethepersonalmodeeffectively.
AIR
CONNECTOR
AIR PLUG
Wrapthecufftofityourarmsnugly,leavingenoughspacefortwofingers
tobeputbetweenyourarmandthecuff.
• Inaccuratereadingsmayresultifthecuffiswrappedincorrectly.
Besuretowrapthecuffcorrectly.
NOTtoo
loose
NOTtootight
DONOTwrapover
heavyclothing
DONOTrollup
yoursleeve
DONOTwrap
overatightshirt
¥Sit on a chair and apply the cuff.
Find a chair and a table so that you can be comfortably seated with your feet flat on the
floor and your back and arm supported.
Put the cuff on your left arm with the air hose
positioned toward your hand.
Attach the cuff with the hook and loop
fastener with the lower edge of the cuff
approximately 2 to 3 cm above the inner
elbow.
Adjust the position of the cuff so that the air
hose and the “ARTERY” mark on the cuff
are over the inner part of your arm over the
brachial artery.
Press the surface of the cuff to make sure that the hook & loop fastens securely.
øLet your forearm rest naturally on the table and keep the cuff at the height of your
heart during measurement.
Ifthecuffislower(orhigher)thantheheart,themeasuredreadingtendstobecomehigher(orlower).
• Take deep breaths and relax.
• Do not move or speak while taking your blood
pressure.
• Donotcrossyourlegsduringmeasurement.
• Donotholdyourbreath.
SDG!DFG
SGLKSJPREJ
DKLFJGS
OGJOIER;J
πStart measurement.
Press the Start/Stop button ( ) to turn on the
unit.
Airisexhaustedfromthecuff.
Automaticinflationstarts.
• Thecuffsymbolisdisplayed.
Press the Start/Stop button ( ) again to
cancel measurement.
Theunitwillexhaustairfromthecuffandturnoff.
Inflationstopsatoptimalpressureandpressurestartsto
decrease.
• Thepulsesymbolisdisplayedasthepulseis
detected.
Airisreleasedfromthecuffandmeasuredvaluesare
displayedasmeasurementcompletes.
• Refertopage1for[ ].
• Refertopage1for[ ].
• Refertopage4for“Err”display.
AUTOMATIC REPEATED INFLATION
Ifyoumoveorstrainyourarmorhand,inflationmay
berepeatedmultipletimestoobtainameasurement.
Repeatedinflationdoesnotindicateamalfunctionof
theunit.
[Select a memory bank to save the
measurement result.
Press the Memory button ( or ) to switch the
bank.
• Tosavethedataontheunit(M1/M2):Pressthe
Memorybutton[M1/M2]( ).Confirmthememory
bankwiththememorymark([ ]or[ ]).
• Tosavethedatafordatatransfer(ID):Pressthe
Memorybutton[ID]( ).Confirmthememorybank
withtheIDnumber(No.1toNo.5).
Readingsareautomaticallysavedinthebank,either
memory[M1]/[M2]or[ID](No.1toNo.5),selectedwhen
theunitisturnedoffaftermeasurement.Makesureto
confirmthebankselectedafterameasurement.
• Refertopage1formemoryfunction.
“Turn off the unit.
Press the Start/Stop button ( ).
Theunitwillbeturnedoff.Evenifyoudonotturnofftheunit,itwillturnoff
automaticallyafter3 minutes.
Do not execute repeated measurements as congestion of blood could result in false
measurement. Let your arm rest for at least 5 minutes.
VIEWING THE SAVED READINGS (MEMORY FUNCTION)
TurnofftheunitoncewiththeStart/Stopbutton( )whentheresultsaredisplayedaftera
measurement.
• Refertopage1formemoryfunction.
¥Select a memory bank to review the saved readings.
Press the Memory button ( or ) to switch the bank.
• Toreviewreadingssavedinthememorybank[M1]or[M2]:
PresstheMemorybutton[M1/M2]( ).
• Toreviewreadingssavedinthememorybank[ID]:Pressthe
Memorybutton[ID]( ).
Theaverageofthesavedreadingsisdisplayed.
• Note:Theaverageisforupto3readingswithin15minutes
beforethelastmeasurement.
• “ ”indicatestheaverage,andthefollowingnumberindicates
thenumberofthesavedresultsusedfortheaverage.
øPress the Up button ( ) or Down button ( ).
• Todisplaythelatestreadingsavedintheselectedmemory
bank:PresstheUpbutton( ).Pressthebuttonrepeatedly
torecallthereadingsfromthelatesttotheoldest.
• Todisplaytheoldestreadingsavedintheselectedmemory
bank:PresstheDownbutton( ).Pressthebutton
repeatedlytorecallthereadingsfromtheoldesttothelatest.
Thedisplayatthetopshowsthememorynumber,measurement
dateandtimealternately.Thelatestreadingisdisplayedas
memory“No.1”.
• Abiggermemorynumberindicatesanolderreading.
πTurn off the unit.
Press the Start/Stop button ( ).
Evenifyoudonotturnofftheunit,itwilldisplaytheresultforapproximately
30secondsandthenturnoffautomatically.
SWITCHING THE RESULT BETWEEN MORNING READING AND NIGHT READING
Youcanswitchbetweenthemorningreadingandnightreadingbypressingthe
Morning/Nightmemorybutton( )whiledisplayingthesavedreading.
• MorningReading: 4–10A.M.
• NightReading: 7P.M.–2A.M.(Thefollowingday)
DELETING SAVED READINGS
¥Display the reading to delete.
• Displaythedesiredreadingtodeleteindividually.
• Displaytheaveragereadingtodeleteallreadingsinthememory.
øPress and hold the Memory button ( or ).
Press and hold the Memory button [M1/M2] ( ) or the Memory button
[ID] ( ) (the same type as the memory displayed) to delete the reading.
Thedisplaywillstartflashing.Holdthebuttonuntilthedisplayiscleared.
(“ ”isdisplayed.)
PRECAUTIONS AND CONTRAINDICATIONS
• Do not use this product without consultation with your doctor if you are under dialysis
therapy or on anticoagulants, antiplatelets or steroids. Use of this instrument under such
conditions could cause internal bleeding.
• For specific information on your blood pressure, contact your physician. Never make any
judgment on your own regarding measurement results.
• Do not use this product along with implantable or wearable medical electrical equipment
such as pacemakers, defibrillators, or electrocardiographic monitors. This product is also not
intended to be used with HF surgical equipment.
• Do not use this product in an explosive environment such as near flammable anesthetics or
inside an oxygen chamber.
• The system may fail to yield the specified measurement accuracy if operated or stored in
temperature or humidity conditions outside the limits stated in the specifications section of
this manual.
• Do not use cuffs or accessories other than those specified by the manufacturer. Otherwise,
correct measurement readings cannot be obtained.
• Use of this product in areas near mobile phones, microwave ovens or other devices with a
strong electromagnetic field may cause malfunctions.
• Do not press the output plug of the AC adaptor during measurement.
• Do not disassemble or modify the product.
• Do not inflate the cuff when it is not wrapped around your arm.
• Do not apply the cuff over a wounded arm, an arm of which side is under an intravascular
access or therapy or an arterio-venous shunt, or an arm on the side of a mastectomy.
Otherwise injury may result.
• Make sure that inflation of the cuff is not causing prolonged impairment of blood circulation.
Also, be cautious about temporary loss of the functions of any other medical equipment if any
monitoring equipment is used on the same limb with the blood pressure measuring cuff.
• To avoid injury due to interfered blood flow from cuff inflation,
–Make sure that the air hose is not twisted before measurement. Otherwise, cuff inflation
may not be conducted properly and prolonged, and
–Do not make measurements repeatedly.
• To avoid any possibility of accidental strangulation, keep this product away from children and
do not drape the air hose around your neck.
• Because the product includes precision parts, avoid extreme temperature variations,
humidity, shock, dust, and direct sunlight. Do not drop or strike the product. Make sure not to
expose it to moisture. This product is not water resistant.
• Do not press the display and operation buttons or place the main unit with the display face
down.
• Do not take out batteries or unplug the AC adaptor when the unit is turned on. Be sure to
switch off the unit before removing batteries or the AC adaptor.
TIPS ON TAKING YOUR BLOOD PRESSURE
• Bloodpressureistheforceexertedbytheheartinpumpingthebloodthroughthearteriesandthe
resistancebytheveinstothisflow.
• Blood pressure varies all the time, influenced by mental and physical factors, and is never
constant.
Ingeneral,bloodpressureishighestduringnormalworkinghoursandgraduallydecreasesduring
theafternoonandeveninghours.Itislowduringsleepandincreasesatarelativelyfastrateafter
arisingfrombed.
Thefollowingarethemaincausesforchangesinbloodpressure:
–Bodymovement
–Conversation
–Mentaltension
–Nervousness
–Emotions
–Eating
–Drinkingalcohol
–Smoking
–Roomtemperature
–Recenturinationorbowelmovement
–Changesinthesurroundingssuchasmovementornoise,etc.
• Let a qualified physician interpret your blood pressure readings.
Dependingonyourage,weightandgeneralcondition,bloodpressurecanbeslightlydifferent.
Consultwithyourdoctorondeterminingwhatbloodpressureisnormalforyou.
• Blood pressure measured at home tends to be lower than when measured in a hospital, clinic
or doctor’s office.
Thisisbecauseyouaretenseatthehospitalandrelaxedathome.Itisimportanttoknowyourstable
normalbloodpressureathome.
• Beforetakingbloodpressure,restforapproximatelyfiveminutesandtakeyourbloodpressure
whilerelaxedinaquietenvironment.
• Measurebloodpressureusingthecorrectpostureanddonotmoveorspeakduringmeasurement.
• Avoidexercise,eating,drinkingalcohol,smokingandotheractivitiesthataffectyourblood
pressurerightbeforeameasurement.
• Takeyourbloodpressureatthesametimeeveryday.
• Theambienttemperatureshouldbeapproximately20˚Cwhenyoutakeyourbloodpressure.
• Readingsmayvaryslightly,dependingonposture,whethersittingorlying.
PREPARATION BEFORE USE
Installbatteriesandactivatetheclockbeforeuse.Measurementcanbemadewithouttheclock being
activated.However,activatingtheclockallowsyoutosavethemeasurementdateandtimewith
readingsforbetterreview.Theclockisdeactivatedasthebatteriesareremoved.Theproductcanbe
alsooperatedwiththeACadaptor.
¥Installing batteries.
Open the battery compartment cover, by
pressing the projection on the bottom of the
main unit.
Install four “AA” type batteries into the compartment.
• Makesurethatthepolaritiescorrespondtothe(+)and(–)marksinside
thebatterycompartment.
• Batteriescanbeeasilyinstalledorremovedbypushingtheir(–)ends
againstthespring.
Close the battery compartment cover completely until you
hear a click.
Batterysymbol[ ]willflashwhenbatterypowerislow.Measurementcannotbemadewhilethe
symbolisdisplayed.Replacethebatteries.Allfourbatteriesneedtobereplacedwithnewones;do
notmixnewandoldbatteriesordifferentbatteries.
• Thesymbolmightappearonlyduringmeasurementalthoughyoucanreviewreadingsinmemory.
Thisisbecausemorebatterypowerisrequiredforconductingameasurement,e.g.inflatingthe
cuff,thandisplayingthereadingsinmemory.Replacethebatteries.
• Theenclosedbatteriesareformonitoring,andtheirlifemaybeshorterthanthatofcommercial
batteries.
øAdjust the date/time and activate the clock.
YoucanalsoadjustthedateandtimeautomaticallybyconnectingtheunitwithNISSEI
HealStyleAppviaBluetooth.Refertopage4fortheBluetoothconnection.
Press and hold the Set button ( ) until “20 15”
starts flashing.
Set the clock in the order of year, month, day, hour
and minute.
• PresstheUpbutton( )toincreasetheflashing
number,andpresstheDownbutton( )todecrease
it.Thenumberwillchangecontinuouslyifyoupress
andholdthebutton.
• PressingtheSetbutton( )willfixthenumberand
thenextitemwillflash.
Decrease ConfirmIncrease
Oncethedateandtimehavebeenset,theclockisactivated.Theclockisdisplayedwhileon
standby.
OPERATION WITH AC ADAPTOR
ConnecttheACAdaptertotheACconnectorlocatedat
thesideofthemainunit.
• UsethedesignatedACadaptoronly.
• Itissuggestedtotakeoutthebatterieswhenusingtheadapter.However,theclockisdeactivated
astheACadaptorisunpluggedsoyoumaywishtoinsertthebatteriestokeeptheclockactivated.
Insuchacase,pleasemakeafewmeasurementswithoutpluggingintheadaptortoavoidabattery
leak.
• DonotconnecttheACadaptortoanypowersocketwhereaccessibilityisnotsatisfactory.
Protection:Thisdeviceisdoubleinsulatedandprotectedagainstshortcircuitsandoverloadbya
primarythermalfuse.
EnclosuresandProtectiveCovers:Equipmentenclosedtoprotectagainstcontactwithliveparts,and
withpartswhichcanbecomelive(finger,pin,hooktest).
− 3 −− 2 −
Click!
Press and hold
DC6V
AC CONNECTOR
2 to 3 cm
ELBOW
AIR HOSE
“ARTERY”
MARK
ARTERY
MEMORY
MARK
TIME
SYSTOLIC
RELIABILITY
SYMBOL
DIASTOLIC
PULSE
PRESSURE
PULSE
RATE
CUFF
SYMBOL
Seepage1.
INFLATION
SYMBOL
PULSE
SYMBOL
MEMORY
NUMBER
EN_DS-S10_IM.indd 2 2015/02/18 16:59
MAKING A MEASUREMENT
Inserttheairplugintotheairconnectorbefore
startingabloodpressuremeasurement.
• Thecuffisapplicabletoarmswithacircumference
between22and42cm.Takeyourarmsizebefore
measurement.
• Chooseyourmemorybankbeforemeasurement
tousethepersonalmodeeffectively.
AIR
CONNECTOR
AIR PLUG
Wrapthecufftofityourarmsnugly,leavingenoughspacefortwofingers
tobeputbetweenyourarmandthecuff.
• Inaccuratereadingsmayresultifthecuffiswrappedincorrectly.
Besuretowrapthecuffcorrectly.
NOTtoo
loose
NOTtootight
DONOTwrapover
heavyclothing
DONOTrollup
yoursleeve
DONOTwrap
overatightshirt
¥Sit on a chair and apply the cuff.
Find a chair and a table so that you can be comfortably seated with your feet flat on the
floor and your back and arm supported.
Put the cuff on your left arm with the air hose
positioned toward your hand.
Attach the cuff with the hook and loop
fastener with the lower edge of the cuff
approximately 2 to 3 cm above the inner
elbow.
Adjust the position of the cuff so that the air
hose and the “ARTERY” mark on the cuff
are over the inner part of your arm over the
brachial artery.
Press the surface of the cuff to make sure that the hook & loop fastens securely.
øLet your forearm rest naturally on the table and keep the cuff at the height of your
heart during measurement.
Ifthecuffislower(orhigher)thantheheart,themeasuredreadingtendstobecomehigher(orlower).
• Take deep breaths and relax.
• Do not move or speak while taking your blood
pressure.
• Donotcrossyourlegsduringmeasurement.
• Donotholdyourbreath.
SDG!DFG
SGLKSJPREJ
DKLFJGS
OGJOIER;J
πStart measurement.
Press the Start/Stop button ( ) to turn on the
unit.
Airisexhaustedfromthecuff.
Automaticinflationstarts.
• Thecuffsymbolisdisplayed.
Press the Start/Stop button ( ) again to
cancel measurement.
Theunitwillexhaustairfromthecuffandturnoff.
Inflationstopsatoptimalpressureandpressurestartsto
decrease.
• Thepulsesymbolisdisplayedasthepulseis
detected.
Airisreleasedfromthecuffandmeasuredvaluesare
displayedasmeasurementcompletes.
• Refertopage1for[ ].
• Refertopage1for[ ].
• Refertopage4for“Err”display.
AUTOMATIC REPEATED INFLATION
Ifyoumoveorstrainyourarmorhand,inflationmay
berepeatedmultipletimestoobtainameasurement.
Repeatedinflationdoesnotindicateamalfunctionof
theunit.
[Select a memory bank to save the
measurement result.
Press the Memory button ( or ) to switch the
bank.
• Tosavethedataontheunit(M1/M2):Pressthe
Memorybutton[M1/M2]( ).Confirmthememory
bankwiththememorymark([ ]or[ ]).
• Tosavethedatafordatatransfer(ID):Pressthe
Memorybutton[ID]( ).Confirmthememorybank
withtheIDnumber(No.1toNo.5).
Readingsareautomaticallysavedinthebank,either
memory[M1]/[M2]or[ID](No.1toNo.5),selectedwhen
theunitisturnedoffaftermeasurement.Makesureto
confirmthebankselectedafterameasurement.
• Refertopage1formemoryfunction.
“Turn off the unit.
Press the Start/Stop button ( ).
Theunitwillbeturnedoff.Evenifyoudonotturnofftheunit,itwillturnoff
automaticallyafter3 minutes.
Do not execute repeated measurements as congestion of blood could result in false
measurement. Let your arm rest for at least 5 minutes.
VIEWING THE SAVED READINGS (MEMORY FUNCTION)
TurnofftheunitoncewiththeStart/Stopbutton( )whentheresultsaredisplayedaftera
measurement.
• Refertopage1formemoryfunction.
¥Select a memory bank to review the saved readings.
Press the Memory button ( or ) to switch the bank.
• Toreviewreadingssavedinthememorybank[M1]or[M2]:
PresstheMemorybutton[M1/M2]( ).
• Toreviewreadingssavedinthememorybank[ID]:Pressthe
Memorybutton[ID]( ).
Theaverageofthesavedreadingsisdisplayed.
• Note:Theaverageisforupto3readingswithin15minutes
beforethelastmeasurement.
• “ ”indicatestheaverage,andthefollowingnumberindicates
thenumberofthesavedresultsusedfortheaverage.
øPress the Up button ( ) or Down button ( ).
• Todisplaythelatestreadingsavedintheselectedmemory
bank:PresstheUpbutton( ).Pressthebuttonrepeatedly
torecallthereadingsfromthelatesttotheoldest.
• Todisplaytheoldestreadingsavedintheselectedmemory
bank:PresstheDownbutton( ).Pressthebutton
repeatedlytorecallthereadingsfromtheoldesttothelatest.
Thedisplayatthetopshowsthememorynumber,measurement
dateandtimealternately.Thelatestreadingisdisplayedas
memory“No.1”.
• Abiggermemorynumberindicatesanolderreading.
πTurn off the unit.
Press the Start/Stop button ( ).
Evenifyoudonotturnofftheunit,itwilldisplaytheresultforapproximately
30secondsandthenturnoffautomatically.
SWITCHING THE RESULT BETWEEN MORNING READING AND NIGHT READING
Youcanswitchbetweenthemorningreadingandnightreadingbypressingthe
Morning/Nightmemorybutton( )whiledisplayingthesavedreading.
• MorningReading: 4–10A.M.
• NightReading: 7P.M.–2A.M.(Thefollowingday)
DELETING SAVED READINGS
¥Display the reading to delete.
• Displaythedesiredreadingtodeleteindividually.
• Displaytheaveragereadingtodeleteallreadingsinthememory.
øPress and hold the Memory button ( or ).
Press and hold the Memory button [M1/M2] ( ) or the Memory button
[ID] ( ) (the same type as the memory displayed) to delete the reading.
Thedisplaywillstartflashing.Holdthebuttonuntilthedisplayiscleared.
(“ ”isdisplayed.)
PRECAUTIONS AND CONTRAINDICATIONS
• Do not use this product without consultation with your doctor if you are under dialysis
therapy or on anticoagulants, antiplatelets or steroids. Use of this instrument under such
conditions could cause internal bleeding.
• For specific information on your blood pressure, contact your physician. Never make any
judgment on your own regarding measurement results.
• Do not use this product along with implantable or wearable medical electrical equipment
such as pacemakers, defibrillators, or electrocardiographic monitors. This product is also not
intended to be used with HF surgical equipment.
• Do not use this product in an explosive environment such as near flammable anesthetics or
inside an oxygen chamber.
• The system may fail to yield the specified measurement accuracy if operated or stored in
temperature or humidity conditions outside the limits stated in the specifications section of
this manual.
• Do not use cuffs or accessories other than those specified by the manufacturer. Otherwise,
correct measurement readings cannot be obtained.
• Use of this product in areas near mobile phones, microwave ovens or other devices with a
strong electromagnetic field may cause malfunctions.
• Do not press the output plug of the AC adaptor during measurement.
• Do not disassemble or modify the product.
• Do not inflate the cuff when it is not wrapped around your arm.
• Do not apply the cuff over a wounded arm, an arm of which side is under an intravascular
access or therapy or an arterio-venous shunt, or an arm on the side of a mastectomy.
Otherwise injury may result.
• Make sure that inflation of the cuff is not causing prolonged impairment of blood circulation.
Also, be cautious about temporary loss of the functions of any other medical equipment if any
monitoring equipment is used on the same limb with the blood pressure measuring cuff.
• To avoid injury due to interfered blood flow from cuff inflation,
–Make sure that the air hose is not twisted before measurement. Otherwise, cuff inflation
may not be conducted properly and prolonged, and
–Do not make measurements repeatedly.
• To avoid any possibility of accidental strangulation, keep this product away from children and
do not drape the air hose around your neck.
• Because the product includes precision parts, avoid extreme temperature variations,
humidity, shock, dust, and direct sunlight. Do not drop or strike the product. Make sure not to
expose it to moisture. This product is not water resistant.
• Do not press the display and operation buttons or place the main unit with the display face
down.
• Do not take out batteries or unplug the AC adaptor when the unit is turned on. Be sure to
switch off the unit before removing batteries or the AC adaptor.
TIPS ON TAKING YOUR BLOOD PRESSURE
• Bloodpressureistheforceexertedbytheheartinpumpingthebloodthroughthearteriesandthe
resistancebytheveinstothisflow.
• Blood pressure varies all the time, influenced by mental and physical factors, and is never
constant.
Ingeneral,bloodpressureishighestduringnormalworkinghoursandgraduallydecreasesduring
theafternoonandeveninghours.Itislowduringsleepandincreasesatarelativelyfastrateafter
arisingfrombed.
Thefollowingarethemaincausesforchangesinbloodpressure:
–Bodymovement
–Conversation
–Mentaltension
–Nervousness
–Emotions
–Eating
–Drinkingalcohol
–Smoking
–Roomtemperature
–Recenturinationorbowelmovement
–Changesinthesurroundingssuchasmovementornoise,etc.
• Let a qualified physician interpret your blood pressure readings.
Dependingonyourage,weightandgeneralcondition,bloodpressurecanbeslightlydifferent.
Consultwithyourdoctorondeterminingwhatbloodpressureisnormalforyou.
• Blood pressure measured at home tends to be lower than when measured in a hospital, clinic
or doctor’s office.
Thisisbecauseyouaretenseatthehospitalandrelaxedathome.Itisimportanttoknowyourstable
normalbloodpressureathome.
• Beforetakingbloodpressure,restforapproximatelyfiveminutesandtakeyourbloodpressure
whilerelaxedinaquietenvironment.
• Measurebloodpressureusingthecorrectpostureanddonotmoveorspeakduringmeasurement.
• Avoidexercise,eating,drinkingalcohol,smokingandotheractivitiesthataffectyourblood
pressurerightbeforeameasurement.
• Takeyourbloodpressureatthesametimeeveryday.
• Theambienttemperatureshouldbeapproximately20˚Cwhenyoutakeyourbloodpressure.
• Readingsmayvaryslightly,dependingonposture,whethersittingorlying.
PREPARATION BEFORE USE
Installbatteriesandactivatetheclockbeforeuse.Measurementcanbemadewithouttheclock being
activated.However,activatingtheclockallowsyoutosavethemeasurementdateandtimewith
readingsforbetterreview.Theclockisdeactivatedasthebatteriesareremoved.Theproductcanbe
alsooperatedwiththeACadaptor.
¥Installing batteries.
Open the battery compartment cover, by
pressing the projection on the bottom of the
main unit.
Install four “AA” type batteries into the compartment.
• Makesurethatthepolaritiescorrespondtothe(+)and(–)marksinside
thebatterycompartment.
• Batteriescanbeeasilyinstalledorremovedbypushingtheir(–)ends
againstthespring.
Close the battery compartment cover completely until you
hear a click.
Batterysymbol[ ]willflashwhenbatterypowerislow.Measurementcannotbemadewhilethe
symbolisdisplayed.Replacethebatteries.Allfourbatteriesneedtobereplacedwithnewones;do
notmixnewandoldbatteriesordifferentbatteries.
• Thesymbolmightappearonlyduringmeasurementalthoughyoucanreviewreadingsinmemory.
Thisisbecausemorebatterypowerisrequiredforconductingameasurement,e.g.inflatingthe
cuff,thandisplayingthereadingsinmemory.Replacethebatteries.
• Theenclosedbatteriesareformonitoring,andtheirlifemaybeshorterthanthatofcommercial
batteries.
øAdjust the date/time and activate the clock.
YoucanalsoadjustthedateandtimeautomaticallybyconnectingtheunitwithNISSEI
HealStyleAppviaBluetooth.Refertopage4fortheBluetoothconnection.
Press and hold the Set button ( ) until “20 15”
starts flashing.
Set the clock in the order of year, month, day, hour
and minute.
• PresstheUpbutton( )toincreasetheflashing
number,andpresstheDownbutton( )todecrease
it.Thenumberwillchangecontinuouslyifyoupress
andholdthebutton.
• PressingtheSetbutton( )willfixthenumberand
thenextitemwillflash.
Decrease ConfirmIncrease
Oncethedateandtimehavebeenset,theclockisactivated.Theclockisdisplayedwhileon
standby.
OPERATION WITH AC ADAPTOR
ConnecttheACAdaptertotheACconnectorlocatedat
thesideofthemainunit.
• UsethedesignatedACadaptoronly.
• Itissuggestedtotakeoutthebatterieswhenusingtheadapter.However,theclockisdeactivated
astheACadaptorisunpluggedsoyoumaywishtoinsertthebatteriestokeeptheclockactivated.
Insuchacase,pleasemakeafewmeasurementswithoutpluggingintheadaptortoavoidabattery
leak.
• DonotconnecttheACadaptortoanypowersocketwhereaccessibilityisnotsatisfactory.
Protection:Thisdeviceisdoubleinsulatedandprotectedagainstshortcircuitsandoverloadbya
primarythermalfuse.
EnclosuresandProtectiveCovers:Equipmentenclosedtoprotectagainstcontactwithliveparts,and
withpartswhichcanbecomelive(finger,pin,hooktest).
− 3 −− 2 −
Click!
Press and hold
DC6V
AC CONNECTOR
2 to 3 cm
ELBOW
AIR HOSE
“ARTERY”
MARK
ARTERY
MEMORY
MARK
TIME
SYSTOLIC
RELIABILITY
SYMBOL
DIASTOLIC
PULSE
PRESSURE
PULSE
RATE
CUFF
SYMBOL
Seepage1.
INFLATION
SYMBOL
PULSE
SYMBOL
MEMORY
NUMBER
EN_DS-S10_IM.indd 2 2015/02/18 16:59
TRANSFERRING THE SAVED DATA
¥Install the NISSEI HealStyle App from the Google Play Store or
Apple App Store to your smartphone, then start the App.
• Compatibledevices:
–iPod/iPhone/iPaddevice:iPhone4SoriPodtouch(5thGeneration)or
laterwithiOS8orlater
–Androiddevice:Android4.3deviceorlaterequippedwithBluetooth4.0
orlater.
• Performtheuserregistrationbeforehand.
øTransfer the saved data.
Touch the Blood Pressure Monitor icon on the App screen.
Press and hold the Bluetooth connection button ( ) on the main unit
for about 3 seconds.
TheBluetoothmarkstartsflashingandtheunitis
switchedtotheconnectionmode.
Touch the reception button on the upper right on
the App screen, and register the ID for connection
displayed on the unit.
Thedatacommunicationstarts.
• FordetailsaboutoperationsoftheApp,visit:<http://
www.nissei-kk.co.jp>.
• OncetheunitisconnectedwiththeNISSEIHealStyleApp,theclockoftheunitisautomatically
synchronizedwiththeconnectedsmartphone.
• IftheBluetoothconnectioncannotbeestablished,turnofftheunitbypressingtheStart/Stop
button( ),thentryagain.
Do not remove the batteries from the unit or disconnect the AC adapter while transferring the
data.
TROUBLESHOOTING
Bloodpressureisextremelyhighorlow.
• Themainunitisnotadjustedtoyourheart.Adjust the main unit to the height of your
heart.
• Measurementisnottakenwiththecorrectpostureorthecuffiswrappedincorrectly.
Reconfirm the measurement procedures.
• Thereadingwaseffectedbymovingortalking.Remain still and quiet during
measurement.
Measuredvaluesvaryallthetime.
Mentalandphysicalconditionsormeasurementconditionsareinfluencingbloodpressure.
Make measurement under the same conditions.
Measuredvalueisdifferentfromthattakenatahospital.
Mentalconditionssuchasnervousnessatahospitalorfeelingrelaxedathomeare
influencingbloodpressure.Take records of blood pressure taken at home and consult
with your doctor.
Bloodpressureischanging24hoursadayinrelationwithmentalandphysical
conditions.Eating,drinking,smoking,exercisingorbathingwillalterbloodpressure.
Bloodpressurewillbealsoinfluencedbymentalconditionssuchasfeelingtenseor
relievedandhealthconditions.Itisimportanttoknowthetendencyofbloodpressureby
makingmeasurementregularly.Makeyourownrulesincludingconditionsandtimeto
makemeasurementandtakebloodpressureeveryday.
Inflationisrepeated.
Thecuffisinflatedagainifasuddenchangeofpressure,whichcouldbeduetomovement
orstrainingofthearmorwrist,wasdetected.Inflationisrepeateduntilbloodpressureis
taken.Repeated inflation is not a malfunction of the unit. Do not move or speak during
measurement.
[Err-1]or[Err-3]isdisplayed.
• Bloodpressurecouldnotbetakenduetomovingorspeaking.Do not move or speak
during measurement.
• Theresultofthemeasurementisoutsideofthemeasurablerange.If [Err-1] or [Err-3] is
displayed for each time you measure the blood pressure, consult with your doctor.
[Err-2]isdisplayed.
• Theairhoseisbentorcrushed.Check the air hose.
• Thecuffisnotsecurelyconnectedtothemainunit.Secure the air connector.
• Thecuffisnotwrappedappropriately.Reconfirm how to put the cuff on your arm.
• Thereadingwaseffectedbymovingortalking.Remain still and quiet during
measurement.
[Err-300]isdisplayed.
Overpressure:bloodpressurecouldnotbetakenduetomovingorspeakingalthoughthe
cuffwasinflatedtothemaximumpressure.Do not move or speak during measurement.
Nothingisdisplayed.
• TheACadaptorisnotconnected.Connect the AC adaptor.
• Thebatteriesaredepleted.Replace all batteries with new ones.
• Thebatteriesareinsertedincorrectly.Reinsert the batteries correctly.
• Thebatteryterminalsarenotclean.Clean the terminals with a dry cloth.
Clockisnotdisplayed.
Theclockisnotactivated.Adjust the date and time and activate the clock.
• NOTE:Theclockisdeactivatedwhenthebatteriesand/orACadaptorare/isremoved.
Measurementdateandtimearedisplayedas“- - / - -”and“- - : - -”.
Theclockisnotactivated.Adjust the date and time and activate the clock.
Measurementwastakenbeforetheclockwasactivated.The measurement date and time
cannot be saved without the clock being activated.
[00]isdisplayed.
TheStart/Stopbutton( )wasbeingpressedwhenthebatterieswerebeinginstalled
orwhenACadaptorwasbeingpluggedin.Turn off the unit once with the Start/Stop
button ( ).
Ifyoucannotgetacorrectmeasurementwiththemethodsabove,contactyourdealer.
Donotdisassembleortamperwiththeinternalmechanism.
PRODUCT SPECIFICATIONS
Model : DS-S10
Operatingprinciple : Oscillometricmethod
Indicator : 15-digitliquidcrystaldisplay
Pressureindicatingrange : 3to300mmHg(cuffpressure)
Measuringrange : 50to250mmHg(systolic),40to180mmHg(diastolic),
40to160bpm(pulserate)
Accuracy* : ±3mmHg(cuffpressure),±5%ofreading(pulserate)
Inflation : Automaticinflation
Deflation : Automatic(electriccontrolvalve)
Exhaust : Automaticexhaustvalve
Powersupply : Four1.5voltLR6(AAalkaline)batteriesorACadaptor
ADP-W5series
Powerconsumption : 4W(max.)
Electricrating : DC6V/4W,withfourLR6batteries
  Adaptor;AC100–240V,50/60Hz,0.12A,
  Unit;DC6V,500mA,withdesignatedACadaptor
Memory : M1/M2;2banks,eachstores60readings
  ID(No.1toNo.5);5banks,eachstores20readings
Bluetoothstandard : BluetoothLowEnergy4.1
Operatingconditions : +10˚Cto+40˚C,30%to85%RH(noncondensing)
Transportation/storageconditions : –20˚Cto+60˚C,10%to95%RH(noncondensing)
Cuff : Coveragearmcircumference;22to42cm,appliedpart;
BF
Mainunit : Weight:Approx.331g(withoutbatteries)
  Size:162.3x127.3x96mm(WxDxH)
Protectionagainstharmfulingressofwater: IP20
Protectionagainstelectricshock : Internallypoweredequipment,TypeBFappliedpart(cuff)
Modeofoperation : Continuousoperation
Classification : Internallypoweredequipment
Keytosymbols : TypeBFappliedpart
 : Refertoinstructionmanual/booklet.
 : ClassIIequipment
Specificationsaresubjecttochangewithoutpriornotice.
ThisproductcomplieswithJIST1115(noninvasiveelectricbloodpressuremonitors)andEMC
(electromagneticcompatibility)StandardIEC60601-1-2:2007.(CISPRClassification:Group1,ClassB).
* TestprocedureisbasedonANSI/AAMISP10:2002,AmericanNationalStandardforelectronicor
automatedSphygmomanometers,andAmendment.
• iPod,iPhone,iPadaretrademarksofAppleInc.,registeredintheU.S.andothercountries.
• AndroidisatrademarkofGoogleInc.
• TheBluetooth®wordmarkandlogosare registeredtrademarksownedbyBluetoothSIG,Inc.and
anyuseofsuchmarksbyNIHONSEIMITSUSOKKICO.,LTD.Corporationisunderlicense.Other
trademarksandtradenamesarethoseoftheirrespectiveowners.
BLOOD PRESSURE MONITOR DS-S10
INSTRUCTIONS
ThismanualisintendedtoassistyouinthesafeandefficientoperationofBLOODPRESSUREMONITORDS-S10.Theproductmustbeusedinaccordancewiththeprocedurescontainedinthismanualand
mustnotbeusedforpurposesotherthanthosedescribedherein.Itisimportanttoreadandunderstandtheentiremanual.Inparticular,pleasereadcarefullyandbecomefamiliarwiththesectionentitled“TIPS
ONTAKINGYOURBLOODPRESSURE”.
CONTENTS
PARTNAMESANDPRODUCTCOMPONENTS................................................................... 1
GENERALINFORMATION..................................................................................................... 1
WARRANTY............................................................................................................................ 1
PRECAUTIONSANDCONTRAINDICATIONS....................................................................... 2
TIPSONTAKINGYOURBLOODPRESSURE...................................................................... 2
PREPARATIONBEFOREUSE............................................................................................... 2
MAKINGAMEASUREMENT.................................................................................................. 3
VIEWINGTHESAVEDREADINGS(MEMORYFUNCTION)................................................. 3
TRANSFERRINGTHESAVEDDATA.................................................................................... 4
TROUBLESHOOTING........................................................................................................... 4
PRODUCTSPECIFICATIONS................................................................................................ 4
PART NAMES AND PRODUCT COMPONENTS
CUFF POUCH INSTRUCTIONS AC ADAPTOR
MAIN UNIT AA (R6) BATTERIES ATTACHED DOCUMENT QUICK START GUIDE
AC CONNECTOR
AIR CONNECTOR
DISPLAY
START/STOP BUTTON
UP BUTTON
DOWN BUTTON
MEMORY BUTTON [ID]
MEMORY BUTTON [M1/M2]
MORNING/NIGHT MEMORY BUTTON
(BLUETOOTH CONNECTION BUTTON)
SET BUTTON
BATTERY
COMPARTMENT
AIR HOSE
AIR PLUG JAPANESE
Thebatteriesmaybe
shortlifeastheyare
fortestuse.
UseAA(LR6)batteries
fornormaluse. ENGLISH&CHINESE
GENERAL INFORMATION
INDICATIONS FOR USE
Thisproductisintendedfornoninvasivemeasurementofsystolicanddiastolicbloodpressure,
determinationofpulserateandcalculationofpulsepressureinadultsinahomehealthcareenvironment.
Theproductisnotdesignedforneonataluse.Pleaseconsultwithyourdoctororphysiciantousethis
producttotakethebloodpressureofachildorpersoninpregnancyorunderpre-eclampticcondition.
PULSE PRESSURE DISPLAY
Thisproductcalculatesanddisplayspulsepressure.
Whilesystolicbloodpressurekeepsincreasingwithage,diastolicbloodpressuretendstostart
decreasingataroundage50.Pulsepressureisavalueobtainedbysubtractingthediastolicvalue
fromthesystolicvalueandsopulsepressuretendstoincreasewithage.Pulsepressurehasbeen
consideredtoberelatedtostiffnessofarteryandhasbeenstudiedasacirculatoryriskfactor.Itis
sometimessaidthatapulsepressureof45mmHgisanormalvalue.Pulsepressureonlydoesnot
representarterialsclerosis.However,observationofpulsepressureinthelongtermwillbeimportant.
CARE AND MAINTENANCE
Keeptheproductclean.Inspectitscleanlinessafteruse.Toclean,useonlyasoftdrycloth.Donot
usegasoline,paintthinner,orotherstrongsolvents.Sincethecuffmayabsorbperspirationandother
fluids,inspectitforstainsanddiscolorationaftereachuse.Whencleaningthecuff,useasynthetic
detergentandgentlyrubthesurface.Airdrythoroughly.Makesurefluidnevergetsintheairhose.Do
notmachinewashorscrubit.
Whenstoringtheproduct,donotplaceheavyobjectsonit.Donotfoldorbendthecuffforcibly.To
disconnectthecufffromthemainunit,donotpulltheairhosebutholdtheairplugandunplugit.Donot
coiltheairhosetootightly.Whentheproducthasbeenstoredatatemperaturebelowfreezing,keepit
foratleast1hourinawarmplacebeforeusing.Removethebatteriesiftheproductistobestoredfor
anextendedperiodoftime.Keepthebatteriesoutofreachofchildren.
Wesuggestthatyouhaveyourbloodpressuremonitorcheckedevery2years.Thisoperationmayonly
beperformedbythemanufacturerorbyfirmsauthorizedbythemanufacturer.
METHOD OF MEASUREMENT
Thisproductemploystheoscillometricmethodformeasurementofbloodpressureandpulserate.The
cuffisconnectedtothemainunitandwrappedaroundthearm.Circuitswithinthecuffsensethesmall
oscillationsinpressureagainstthecuffproducedbytheexpansionandcontractionofthearteriesinthe
arminresponsetoeachheartbeat.Theamplitudeofeachpressurewaveismeasured,convertedto
millimetersofmercury,anddisplayedontheLCDasadigitalvalue.
FUZZY INFLATION
ThisproductemploysFUZZYinflationtoeasestresson
thearmduringcuffinflation.Bydetectingpulsesignals
whileinflating,thisproductisabletodeterminethe
sufficientpressureforeachmeasurement.
CUFF SYMBOL
Thisproductdisplayswhetherthecuffisappliedproperlyornotbyanalyzingthepressurewave.[ ]
indicatesthatthecuffisappliedproperly.Iftheindicationisnotdisplayed,thecuffmaybewrappedtoo
tightlyortooloosely.
RELIABILITY SYMBOL
Someoftheimportantaspectsinmeasuringbloodpressurearehowproperlythecuffisappliedand
howcalmyouareduringmeasurement.Theseaspectscanaffectmeasurementvaluesandsuchvalues
cannotsaidtobecorrectvalues.Thisproductshows[ ]whenthemeasurementissupposedly
madeingoodconditionwithoutinfluencesfromsuchaspects.
BODY MOTION SYMBOL
Bloodpressurevaluetakenwhilemovingcannotbesaidtobethecorrectvaluebecausebody
movementcanaffectbloodpressure.
Thisproductanalyzesthepulsewaveanddisplays[ ]whenbodymotionisdetected.
[ ]indicatestheresultsmightbeaffectedbybodymovement.
IRREGULAR PULSE RHYTHM SYMBOL
Pulserhythmcanbedisturbedbytalking,movingor
arrhythmias.Thisproductdisplays[ ]whenthe
differenceoftheshortestandlongesttimeintervals
betweenpulsewavesisover25%,indicatingirregular
pulserhythm.
MEMORY FUNCTION
Themeasuredvaluesareautomaticallysavedforlaterreviewinamemorybank:[M1]or[M2]tosave
thedataontheunit,and[ID](5banks;IDNo.1toNo.5)totransferthedatatoNISSEIHealStyleApp.
Thesememorybankscanbeusedtosavereadingsofseveralpersonsseparatelyortosavemorning
readingsandeveningreadingsseparately.
Youcansaveupto60readingseachon[M1]or[M2]bank,and20readingseachon[ID]bank(IDNo.1
toNo.5).Whenthenumberofstoredreadingsreachesitslimit,theoldestreadingwillbedeletedto
recordanewreading.
Savedreadingsarerecalledwiththemeasurementdateandtimewhentheclockfunctionisactivated.
(Theclockneedstobeactivatedbeforemeasurementforthedateandtimetobesavedwiththe
measuredvalued.)
[Err]resultsarenotsaved.
WARRANTY
Thisequipmentisguaranteedfortheperiodof1yearafterthedateofpurchaseagainstmanufacturingdefectswhenreturnedalongwiththeproofofdateofpurchasetothedealerfromwhomthepurchasewas
made.Duringthisperiod,theunitwillberepairedorreplacedfreeofchargeifthefailureisattributabletofaultydesignormanufacture.Thiswarrantydoesnotcoverdamageormalfunctionscausedbyimproper
handlingorusecontrarytotheinstructionsinthismanual.Pleasecontactyourdealerforadditionalwarrantyprovisionswhichmayremaineffectiveafterthemanufacturer’swarrantyperiodhasexpired.
Manufacturer:
NIHON SEIMITSU SOKKI CO., LTD.
2508-13NakagoShibukawaGunma377-0293Japan
websitehttp://www.nissei-jp.com
Regularpulserhythm
Anexampleofirregularpulserhythm
comparedtoregularpulserhythm
− 1 −− 4−
Press and hold
NISSEI
HealStyle
血圧計
ID FOR
CONNECTION
BLUETOOTH
MARK
受信
測定結果(ニックネーム1)
日付 時刻 最高 最低 脈拍
リスト グラフ プロフィール ID
受信
PRESSURE
TIME
INITIAL
PRESSURE
EN_DS-S10_IM.indd 1 2015/02/18 16:59

Other Nissei Blood Pressure Monitor manuals

Nissei DSK-1011 User manual

Nissei

Nissei DSK-1011 User manual

Nissei DSK-1031 User manual

Nissei

Nissei DSK-1031 User manual

Nissei WSK-1011 User manual

Nissei

Nissei WSK-1011 User manual

Nissei WS-1300 User manual

Nissei

Nissei WS-1300 User manual

Nissei ds-1902 User manual

Nissei

Nissei ds-1902 User manual

Nissei WS-1011 User manual

Nissei

Nissei WS-1011 User manual

Nissei DSK-1031 User manual

Nissei

Nissei DSK-1031 User manual

Nissei DSK-1011J User manual

Nissei

Nissei DSK-1011J User manual

Nissei DS-B10 User manual

Nissei

Nissei DS-B10 User manual

Nissei DS-137 User manual

Nissei

Nissei DS-137 User manual

Nissei WS-820 User manual

Nissei

Nissei WS-820 User manual

Nissei DS-1873 User manual

Nissei

Nissei DS-1873 User manual

Nissei DSK-1031 User manual

Nissei

Nissei DSK-1031 User manual

Nissei DS-500 User manual

Nissei

Nissei DS-500 User manual

Nissei DSK-1011 User manual

Nissei

Nissei DSK-1011 User manual

Nissei DS-10 User manual

Nissei

Nissei DS-10 User manual

Nissei DS-10a User manual

Nissei

Nissei DS-10a User manual

Nissei WS-820 User manual

Nissei

Nissei WS-820 User manual

Nissei DS-400 User manual

Nissei

Nissei DS-400 User manual

Nissei WSK-1011 User manual

Nissei

Nissei WSK-1011 User manual

Nissei DSK-1031 User manual

Nissei

Nissei DSK-1031 User manual

Nissei DS-1011 User manual

Nissei

Nissei DS-1011 User manual

Nissei DS-10 User manual

Nissei

Nissei DS-10 User manual

Nissei WSK-1011 User manual

Nissei

Nissei WSK-1011 User manual

Popular Blood Pressure Monitor manuals by other brands

A&D AccuFit manual

A&D

A&D AccuFit manual

Microlife Deluxe BPM3 instruction manual

Microlife

Microlife Deluxe BPM3 instruction manual

Invacare ISG4002654 owner's manual

Invacare

Invacare ISG4002654 owner's manual

Sencor SBD 1470 user manual

Sencor

Sencor SBD 1470 user manual

ReliOn HEM-780REL instruction manual

ReliOn

ReliOn HEM-780REL instruction manual

ADC e-shpyg 3 Instructions for use

ADC

ADC e-shpyg 3 Instructions for use

Omron IntelliSense HEM-790ITCAN instruction manual

Omron

Omron IntelliSense HEM-790ITCAN instruction manual

Topcom BPM WRIST 3500 user guide

Topcom

Topcom BPM WRIST 3500 user guide

Archos Blood Pressure Monitor user manual

Archos

Archos Blood Pressure Monitor user manual

Omron BP9300T instruction manual

Omron

Omron BP9300T instruction manual

Omron RS6 instruction manual

Omron

Omron RS6 instruction manual

Leader BP3MS1-3B instruction manual

Leader

Leader BP3MS1-3B instruction manual

AEG BMG 4906 operating instructions

AEG

AEG BMG 4906 operating instructions

Microlife BP B2 Basic manual

Microlife

Microlife BP B2 Basic manual

HoMedics BPW-200-0 TheraP instruction manual

HoMedics

HoMedics BPW-200-0 TheraP instruction manual

Medisana 51230 manual

Medisana

Medisana 51230 manual

Meraw Cedar user manual

Meraw

Meraw Cedar user manual

Cigii B06T user manual

Cigii

Cigii B06T user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.