manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. OHAUS
  6. •
  7. Measuring Instrument
  8. •
  9. OHAUS ST Series User manual

OHAUS ST Series User manual

This manual suits for next models

8

Other OHAUS Measuring Instrument manuals

OHAUS STARTER 2200 User manual

OHAUS

OHAUS STARTER 2200 User manual

OHAUS CKW Series User manual

OHAUS

OHAUS CKW Series User manual

OHAUS ST20C-A User manual

OHAUS

OHAUS ST20C-A User manual

OHAUS Defender T24PE User manual

OHAUS

OHAUS Defender T24PE User manual

OHAUS Defender 2000 Series User manual

OHAUS

OHAUS Defender 2000 Series User manual

OHAUS i-DT33P User manual

OHAUS

OHAUS i-DT33P User manual

OHAUS Defender 3000 User manual

OHAUS

OHAUS Defender 3000 User manual

OHAUS i-DT33P User manual

OHAUS

OHAUS i-DT33P User manual

OHAUS MB27 User manual

OHAUS

OHAUS MB27 User manual

OHAUS MB35 User manual

OHAUS

OHAUS MB35 User manual

OHAUS 5000 User manual

OHAUS

OHAUS 5000 User manual

OHAUS 7000 Series User manual

OHAUS

OHAUS 7000 Series User manual

OHAUS MB45 User manual

OHAUS

OHAUS MB45 User manual

OHAUS Defender i-DT61PW User manual

OHAUS

OHAUS Defender i-DT61PW User manual

OHAUS MB35 User manual

OHAUS

OHAUS MB35 User manual

OHAUS TD52P User manual

OHAUS

OHAUS TD52P User manual

OHAUS STARTER 300C User manual

OHAUS

OHAUS STARTER 300C User manual

OHAUS TD52 User manual

OHAUS

OHAUS TD52 User manual

OHAUS TD32PE User manual

OHAUS

OHAUS TD32PE User manual

OHAUS ST20D User manual

OHAUS

OHAUS ST20D User manual

OHAUS CD-1 User manual

OHAUS

OHAUS CD-1 User manual

OHAUS MB45 User manual

OHAUS

OHAUS MB45 User manual

OHAUS MB23 User manual

OHAUS

OHAUS MB23 User manual

OHAUS STARTER 3100C User manual

OHAUS

OHAUS STARTER 3100C User manual

Popular Measuring Instrument manuals by other brands

Suaoki D40 user manual

Suaoki

Suaoki D40 user manual

Elster BK-G1.6 operating instructions

Elster

Elster BK-G1.6 operating instructions

Endress+Hauser Deltabar FMD71 technical information

Endress+Hauser

Endress+Hauser Deltabar FMD71 technical information

Duratool D03128 manual

Duratool

Duratool D03128 manual

Vega VEGAPULS 65 Quick setup guide

Vega

Vega VEGAPULS 65 Quick setup guide

Tonghui TH2618B Operation manual

Tonghui

Tonghui TH2618B Operation manual

Tenmars TM-801 user manual

Tenmars

Tenmars TM-801 user manual

MSR 145 user manual

MSR

MSR 145 user manual

TPS WP-82 manual

TPS

TPS WP-82 manual

PCB Piezotronics 003C30 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 003C30 Installation and operating manual

Tenma 72-10465 manual

Tenma

Tenma 72-10465 manual

Endress+Hauser Proline Promag 50 Brief operating instructions

Endress+Hauser

Endress+Hauser Proline Promag 50 Brief operating instructions

Siemens SITRANS F Coriolis FCT030 Function manual

Siemens

Siemens SITRANS F Coriolis FCT030 Function manual

KLINGER CMF V Series instruction manual

KLINGER

KLINGER CMF V Series instruction manual

Keysight M8290A Getting started guide

Keysight

Keysight M8290A Getting started guide

Acterna MS1400 Operation manual

Acterna

Acterna MS1400 Operation manual

R&S ZPH manual

R&S

R&S ZPH manual

Datacolor ColorReader DC10-2 user guide

Datacolor

Datacolor ColorReader DC10-2 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

PRESENTED BY
JPBOWLIN.COM
817.332.8116
J.P. Bowlin is a quality-driven Calibration Company
that has provided calibration, repair and sales
of all types of weighing and measurement products since 1931.
ST Series Pen Meter
Instruction Manual
Thank you for choosing OHAUS waterproof pen meters. Please read the manual completely before using. This manual
serves the following model:
Thank you for choosing OHAUS waterproof pen meters. Please read the manual completely before using. This manual serves the following
models:
• ST10C-A (pen Conductivity meter)
• ST10C-B (pen Conductivity meter)
• ST10C-C (pen Conductivity meter)
• ST10T-A (pen TDS meter)
• ST10T-B (pen TDS meter)
• ST10S (pen salinity meter)
Accuracy
ST10C/ST10T/ST10S pen meters are factory calibrated.
Maintenance
Clean the electrode before and after each measurement .
The meter use button battery 1.5V (AA)*4 , replace all the batteries when the display fade or not turn on.
ST10C/ST10T/ST10S pen meters Instruction Manual
First Usage
Condition the electrode by rising and immersing it in pure water for 0.5 hour before use.
Conductivity/TDS/Salinity Measurement
Remove the protection cap, rinse the Conductivity electrode with pure water (distilled water), and wipe clean.
• Press button-On/Off turn on the meter.
• Dip the electrode about 2 to 3cm into the test solution (at least 20ml). Wait until the reading stabilized.
• Clean the electrode with pure water after each measurement.
The electrode is replaceable.
Welcome to OHAUS (www.ohaus.com)!
After more than a century of perfecting the art of measurement through our durable weighing products, OHAUS precision is now available in a
line of portable electrochemistry products that providesaccurate measurement of pH, ORP, conductivity, TDS and salinity.
ST series pen meters are the economical option when you are simply looking for meters that are easy to use and provide accurate measurements.
The pen meters should not be used by Children of age 12 or younger.
This product conforms to the EMC Directive 2004/108/EC. The Declaration of Conformity is available online at europe.ohaus.com/eu-
rope/en/home/support/compliance.aspx.
Order Information
Specification
Model
ST10C-A
ST10C-B
ST10C-C
ST10T-A
ST10T-B
ST10S
Description
Pen Conductivity Meter, range 0.0~199.9 μS/cm
Pen Conductivity Meter, range 0~1999 μS/cm
Pen Conductivity Meter, range 0.00~19.99 mS/cm
Pen TDS Meter, range 0.0-100.0 mg/L
Pen TDS Meter, range 0-1000 mg/L
Pen Salinity Meter, range 0.0-10.0 ppt
Water Proof Pen Meters
Cond. range
Resolution
Accuracy
Battery
Dimension
Weight
Auto-off
Ambient temperature
Materials
ST10C-A
0.0~199.9 μS/cm
0.1 μS/cm
±2.5% FS
4 x 1.5V
183×45×35mm
105g
After 6 min no operation
0~50 °C(32-122°F)
ABS
ST10C-B
0~1999 μS/cm
1 μS/cm
±2.5% FS
4 x 1.5V
185x42x37mm
105g
After 6 min no operation
0~50 °C(32-122°F)
ABS
ST10C-C
0.00~19.99 mS/cm
10 μS/cm (0.01 mS/cm)
±2.5% FS
4 x 1.5V
185x42x37mm
105g
After 6 min no operation
0~50 °C(32-122°F)
ABS
ST10T-A
0.0-100.0 mg/L
0.1 mg/L
±2.5% FS
4 x 1.5V
185x42x37mm
105g
After 6 min no operation
0~50 °C(32-122°F)
ABS
ST10T-B
0-1000 mg/L
1 mg/L
±2.5% FS
4 x 1.5V
185x42x37mm
105g
After 6 min no operation
0~50 °C(32-122°F)
ABS
ST10S
0.0-10.0 ppt
0.1 ppt
±2.5% FS
4 x 1.5V
185x42x37mm
105g
After 6 min no operation
0~50 °C(32-122°F)
ABS
Replaceable electrodes:
Electrode CT10A ST
Electrode CT10B ST
Electrode CS10C ST
In conformance with the European Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE) this device may not be disposed of in domestic waste.
This also applies to countries outside the EU, per their specific requirements. Please dispose of this product in accordance with local regulations at the collecting point
specified for electrical and electronic equipment. If you have any questions, please contact the responsible authority or the distributor from which you purchased this
device. Should this device be passed on to other parties (for private or professional use), the content of this regulation must also be related. Disposal instructions in Europe
are available online at europe.ohaus.com/europe/en/home/support/weee.aspx. Thank you for your contribution to environmental protection.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna, increase the separation between
the equipment and receiver or consult the dealer or an experienced radio/TV technician for help.