QUICK START
GUIDE

2
WELCOME
PODDER™!
This guide provides you with
step-by-step instructions for
getting started with your new
Omnipod DASH™System.
+If you are new to the Omnipod
DASH™System, this guide will be
helpful during your live-training with
your Certified Pod Trainer.
+If you are a current user of the Omnipod®
System, use the Omnipod DASH™
System User Guide, Quick Start Guide
and online training module to get started.
You can view the Omnipod DASH™
System online training module in your
PodderCentral™account.
BEFORE YOU DASH™ON …
Please ensure you thoroughly review your Omnipod DASH™System User Guide before
you attempt to start your device.
Personal Diabetes Manager (PDM) Kit
+Take an inventory of your Personal
Diabetes Manager (PDM) Kit
+Register your Omnipod DASH™ System at
PodderCentral™
If you have any questions about setting up your new
Personal Diabetes Manager please contact Customer Care at
800-591-3455 (outside US 978-600-7850) for support 24 hours
a day, 7 days a week.
If you have any questions about your individual pump therapy
settings, please contact your healthcare provider.
PDM + Battery Black
PDM Skin
Carry Case User Guide
*Upto 72 hours of insulin delivery
USER
GUIDE
www.myomnipod.com
InsuletCorporation
600Technology Park Drive, Suite 200
Billerica,MA 01821 USA
1.800.591.3455/1.978.600.7850
©2018Insulet Corporation. Omnipod, the Omnipod logo, Podder, DASH, and the
DASHlogo,are trademarks or registered trademarks of Insulet Corporation. All rights reserved.
Reference#: PDM-USA1-D001-MG-USA1
18296-ENG-AWRev. B 06/18
OMNIPOD DASH
TM
USER GUIDE
Podder’s handbook
TM
Charging Cable
& Adapter

Here’s How to Access:
• Visit www.myomnipod.com/PodderCentral and create an account
• If you don’t have access to a computer, call Customer Care at 800-591-3455
and select Option 2
REGISTER
YOUR OMNIPOD
DASH™SYSTEM AT
PODDERCENTRAL™
A Digital Home For Podders™
+Get Access to Omnipod DASH™System Online Training!
+Manage your Omnipod DASH™account online

4
CURRENT
USER? START
HERE!
+To set up your new Omnipod DASH™
System Personal Diabetes Manager, you
need settings from either your current
Personal Diabetes Manager (model
UST400) or pump therapy settings
provided by your healthcare provider.
+If you currently use the previous
generation Personal Diabetes Manager
(model UST400), the instructions to
the right will help you find your current
settings.
NEW USER?
SKIP THIS
SECTION
Your Certified Pod Trainer will work with
your healthcare provider to obtain your
pump therapy settings.
For your safety, please do not attempt to
create your own Omnipod DASH
™
System
Personal Diabetes Manager settings.
3:00p 5/15
Bolus
More actions
Temp basal
My records
Settings
Suspend
Status Select
3:00p 5/15
Basal Programs
Presets
System setup
Vibration
Back Select
How to Find Your Basal Program(s)
2. Select Basal
Programs
3:00p 5/15
Basal programs:
basal 1
basal 2
Weekend
[add new]
Back Select
Enable
1. On Home
Screen
Select
Settings
4. You will
first see the
graph, press
List to view
your basal
segments as
shown
+Take note of
your Total
Daily Basal
3. Select
the basal
program
to review.
On the next
screen,
select View
3:00p 5/15
Basal 1:
Segment U/hr
12:00a- 8:00a0.60
8:00a- 3:00p0.80
3:00p- 12:00a0.75
Daily basal: 17.15 U
Back Graph

3:00p 5/15
Bolus
More actions
Temp basal
My records
Settings
Suspend
Status Select
3:00p 5/15
Basal Programs
Presets
System setup
Vibration
Back Select
3:00p 5/15
Date/time
Bolus/basal/calcs
Alerts/reminders
BG meter
PDM options
Diagnostics
Back Select
3:00p 5/15
Bolus calc: On
Ratios/factors/targets
Temp basal: Off
Extended: Off
Bolus increment: 0.10U
Max bolus: 10.00U
Max basal: 3.00U/hr
Back Select
3:00p 5/15
Review all settings
Target BG
Min BG for calcs:
70 mg/dL
IC ratio
Correction factor
Reverse correction: On
Insulin action: 4.0hr
Back Select
How to Find Your Bolus Calculator Settings
5
2. Select
System
setup
1. On Home
Screen
Select
Settings
3. Select
Bolus/basal/
calcs
5. Select
Review all
settings
4. Select
Ratios/
factors/
targets.
NOTE: Bolus
calcs must
be “0n.”

6
MY PERSONAL
DIABETES
MANAGER
SETTINGS
You may use the following
worksheet to write down
your Personal Diabetes
Manager settings from
your current PDM (model
UST400).
6

7
1. Maximum Basal Rate _____U/h
_____ to _____ _____U/hr
2. Basal 1 _____ to _____ _____U/hr Total Daily Basal ______U
_____ to _____ _____U/hr
_____ to _____ _____U/hr
3. Temporary Basal Rate On Off (Select “On” if model UST400 is set
to % or U/Hr. “On” is in %)
4. BG Goal Limits Lower Limit_____mg/dL Upper Limit_____mg/dL Find in model UST400: Settings>
System Setup>BG Meter>BG Goal
5. Suggested Bolus Calculator On Off
_____ to _____ Target_____ mg/dL Correct Above_____mg/dL
6. Target BG _____ to _____ Target_____ mg/dL Correct Above_____mg/dL
_____ to _____ Target_____ mg/dL Correct Above_____mg/dL
_____ to _____ Target_____ mg/dL Correct Above_____mg/dL
7. Min BG – for bolus calculations _____mg/dL
_____ to _____ _____g/carb
8. Insulin-to-Carbohydrate (IC) Ratio _____ to _____ _____g/carb
_____ to _____ _____g/carb
_____ to _____ _____g/carb
_____ to _____ _____mg/dL (1 unit of insulin decreases BG by)
9. Correction Factor _____ to _____ _____mg/dL (1 unit of insulin decreases BG by)
_____ to _____ _____mg/dL (1 unit of insulin decreases BG by)
_____ to _____ _____mg/dL (1 unit of insulin decreases BG by)
10. Reverse Correction On Off
11. Duration of Insulin Action _____hours
12. Maximum Bolus _____U
13. Extended Bolus On Off (Select “On” if model UST400 is set
to % or U/Hr. “On” is in %)
12am
12am
12am
12am

8
SET UP YOUR
OMNIPOD
DASH™SYSTEM
PERSONAL
DIABETES
MANAGER
Be sure to register your
Omnipod DASH™Personal
Diabetes Manager (PDM)
on PodderCentral™!
+Use the pull-tab to remove the back cover.
+Insert the battery into the Personal Diabetes Manager.
+Remove the pull-tab and replace the back cover.
+The Personal Diabetes Manager is rechargeable, similar
to common mobile devices.
+Charge frequency is based on device usage.
We suggest you charge your device during bedtime and stick with a similar time each day.
The Personal Diabetes Manager Battery

+Hold down the Power button
to wake your Personal
Diabetes Manager.
+You will begin by personalizing your new Personal Diabetes
Manager!
+After personalization, you will enter your insulin delivery settings.
+The Personal Diabetes Manager guides you step-by-step. Be sure
to read each screen, and accurately enter each setting.
+For more information, refer to Chapter 2 “Initial PDM Setup” in the
Omnipod DASH™System User Guide.
Omnipod DASH™System Initial Personal Diabetes Manager Setup
Your initial pump therapy settings are needed to setup your new Personal Diabetes Manager.
These settings are provided to you by your healthcare provider.
9

10
PAIR YOUR
CONTOUR®NEXT
ONE BG METER
1. Tap “BG Meter Pairing
Instructions”
If you do not want to pair to a
BG meter, tap “SKIP”
2. Follow the on-screen
instructions, then tap “START
SEARCH”
Pair your CONTOUR®NEXT ONE BG Meter
+Pair your CONTOUR®NEXT ONE Blood Glucose Meter with your PDM during the initial
setup, or you can do so later through the PDM settings screens. Only readings taken on
a paired CONTOUR®NEXT ONE meter will be transferred wirelessly to the PDM’s bolus
calculator.
+BG readings taken on a different meter can only be entered manually. If you do not want to
pair a CONTOUR®NEXT ONE BG Meter at this time, tap SKIP.

3. Select the device to pair from
available meters
4. Your PDM is now paired with
your blood glucose meter
11

12
SET UP A
NEW POD
1. In the “Pod Info” screen, tap
“SET UP NEW POD”
2. Carefully follow the on-
screen instructions

13
Inject the insulin into the fill port. The Pod beeps twice. Remove
the needle from the insulin fill port. Replace the needle’s protective
cap and remove the needle from the fill syringe for proper sharps
disposal.
NEVER inject air into the fill port. Doing
so may result in unintended or interrupted
insulin delivery.
NEVER use a Pod if you feel resistance while
depressing the plunger of the fill syringe.
This condition can result in interrupted insulin
delivery.
With the Pod still in its tray place it next to and touching the
Personal Diabetes Manager to ensure proper communication. Press
“NEXT” on the Personal Diabetes Manager. The system performs a
series of safety checks and automatically primes the Pod.
Your Pod is now ready for application and cannula insertion. For
more information, please refer to Chapter 3 “Changing your Pod” in
your Omnipod DASH™System User Guide.
Collect the following supplies:
+Omnipod DASH™System Personal Diabetes Manager
+Unopened Omnipod DASH™System Pod
+Alcohol swabs
+Vial of room temperature rapid-acting U-100 insulin
Wash your hands with soap and water. Clean the top of the insulin
vial with an alcohol swab.
Remove the fill needle and syringe from the Pod’s tray. Keep the
Pod in its tray during set up. Confirm the Pod’s needle cap is blue.
This ensures your Pod is compatible with your Omnipod DASH™
System Personal Diabetes Manager. Twist the fill needle clockwise
onto the top of the syringe. Do not use any other type of needle or
filling device besides the syringe provided with each Pod.
Remove the syringe’s protective cap from the needle. Draw air into
the syringe equal to the amount of insulin you will use. You must fill
your syringe with at least 85 units of insulin. Insert the needle into
the vial and inject air.
Turn the vial upside down and slowly withdraw insulin. Tap or flick
the filled syringe to remove any bubbles.
Remove the needle from the vial and insert it into the Pod’s insulin
fill port. An arrow on the white paper backing points to the fill port.
Do not inject insulin into any other location on the Pod. The Pod
should still be in its package during fill.
To ensure proper fill, do not insert the fill
syringe at an angle into the fill port.
8
9
1
2
3
4
5
6
7

14
KEY INSULIN
DELIVERY
ACTIONS
Disclaimer: The following screens are for demonstration
purposes only. The values shown are educational
and may not reflect real life scenarios.
1. Tap Menu icon on the Home
screen
2. Tap “Suspend Insulin”
and follow the on-screen
instructions
Suspend Insulin Delivery

15
1. Tap Menu icon on the Home
screen
2. Tap “Set Temp Basal” 3. Tap “Basal Rate” entry box
and select your % change.
Tap “Duration” entry box and
select your time duration. Tap
“Confirm”
Set a Temporary Basal Rate

16
1. Tap “Basal” tab on the Home
screen. Tap “VIEW”
2. Tap “EDIT”
Edit an Active Basal Program
NOTE: You must suspend insulin before editing the active Basal Program.
KEY INSULIN
DELIVERY
ACTIONS
Disclaimer: The following screens are for demonstration
purposes only. The values shown are educational
and may not reflect real life scenarios.

17
3. Tap “SUSPEND INSULIN” 4. Tap to edit program name and
tag or tap “NEXT” to edit basal
time segments and rates
5. Once you are finished editing,
tap “RESUME INSULIN”

18
KEY INSULIN
DELIVERY
ACTIONS
Deliver a Bolus
Disclaimer: The following screens are for demonstration
purposes only. The values shown are educational
and may not reflect real life scenarios.
1. Tap the “Bolus” icon on the
Home screen
2. Tap the “Enter Carbs”
entry box to input grams of
carbs. Sync or enter your
BG manually by tapping the
“ENTER BG” entry box

3. Review your values, then tap
“CONFIRM”
4. Tap “START” to begin bolus
delivery
19

800-591-3455
978-600-7850
www.myomnipod.com
Insulet Corporation
100 Nagog Park
Acton, MA 01720
© 2018 Insulet Corporation. Omnipod, the Omnipod logo,
DASH, the DASH logo, Podder, and PodderCentral are
trademarks or registered trademarks of Insulet Corporation. All
rights reserved.
18419-USA-ENG-AW Rev. C 10/18
For More Information:
Please refer to your Omnipod DASH™System User Guide
Visit us online at myomnipod.com
Download the Omnipod®Patient App!
Other manuals for DASH System
3
Table of contents
Other OmniPod Medical Equipment manuals

OmniPod
OmniPod PODDER Firmware update

OmniPod
OmniPod PDM Series Firmware update

OmniPod
OmniPod DASH System User manual

OmniPod
OmniPod Pod User manual

OmniPod
OmniPod DASH SYSTEM PODDER Firmware update

OmniPod
OmniPod PDM CAT45E User manual

OmniPod
OmniPod 5 User manual

OmniPod
OmniPod PODDER Firmware update

OmniPod
OmniPod 5 Manual

OmniPod
OmniPod 5 User manual
Popular Medical Equipment manuals by other brands

Dorel Juvenile Group
Dorel Juvenile Group Safety 1st Hospital's Choice IH417 instructions

Nasco
Nasco Life/form LF00901U instruction manual

Abbott
Abbott Whitestar Signature Operator's manual

Avante
Avante Volumax Quick reference guide

Crivit
Crivit CEB 1400 A1 operating instructions

Medtrum
Medtrum A6 TouchCare user guide