3
3. General Ratings
Rated voltage Non-inductive load Inductive load
Resistive load Lamp load Inductive load Motor load
NC NO NC NO NC NO NC NO
125 VAC 10 A 3 A 1.5 A 10 A 5 A 2.5 A
250 VAC 10 A 2 A 1 A 10 A 3 A 1.5 A
8 VDC 10 A 6 A 3 A 10 A 6 A
14 VDC 10 A 6 A 3 A 10 A 6 A
30 VDC 6 A 4 A 3 A 6 A 4 A
125 VDC 0.8 A 0.2 A 0.2 A 0.8 A 0.2 A
250 VDC 0.4 A 0.1 A 0.1 A 0.4 A 0.1 A
Note: 1. Resistive loads have a power factor (cos = φ) of 1.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp loads have an inrush current of 10 times the steady-state current, while motor loads have an inrush current of 6 times the
steady-state current.
4. Inrush current: NC: 30 A max.; NO: 30 A max.
CHARACTERISTICS
Operating speed 0.05 to 0.5 m/s
Operating frequency 30 operations/min max.
Operating characteristics Positive opening
force 19.61 N (4.41 lbf) min.
Positive opening
stroke 20 mm (0.79 inch) min.
All stroke 23 mm (0.91 inch) min.
Locked resistive pulling force 700 N (157 lbf) min.
Insulation resistance 100 MΩmin. (at 500 VDC)
Rated insulation voltage (Ui) 300 VAC
Conventional enclosed thermal current (Ithe) (rated
continuous current) 10 A
Dielectric strength (Uimp)Impulse dielectric strength (Uimp) 4 kV (IEC 947-5-1) between terminals of
different polarity, between each terminal and ground, and between each terminal
and non-current-carrying metal part; 2.5 kV between solenoid and ground
Short-circuit protective device 10 A fuse (type gl) (IEC269)
Contact resistance 50 mΩmax. (initial value)
Vibration resistance Malfunction 10 to 55 Hz, 0.35-mm single amplitude with an imposed acceleration of 50 m/s2
(5G) max. (IEC68-2-6)
Shock resistance Destruction 1,000 m/s2(100G) min. (IEC68-2-27)
Malfunction 300 m/s2(30G) min. (IEC68-2-27)
Life expectancy Mechanical 1,000,000 operations min.
Electrical 500,000 operations min. (with a load rate of 0.5)
Ambient temperature Operating –10 to 55°C (14 to 131°F) with no icing
Ambient humidity Operating 95% max.
Operating environmental pollution level Pollution degree 3 (IEC947-5-1)
Insulation class Insulation class I (IEC536)
Enclosure rating (See Note.) UL 6P and 13
NEMA 6P and 13
IEC529 IP67 (60947-5-1)
Note: Although the switch box does not allow the penetration of dust, oil or water, keep the operation key insertion slot free of dust, oil,
and water.
D4BL D4BL