Optex WNX-40HW User manual

ledoM
Passive Infrared
40ftx40ft (12mx12m) 85˚
5ft - 8ft (1.5m - 2.4m)Mounting height
Detection method
Coverage
78 zones
3°F (1.6°C) at 2ft / sec (0.6m/sec)
1 - 5ft/sec. (0.3 - 1.5m/sec.)
Switch-able ON/OFF
Detection zones
Sensitivity
Detectable speed
LED indicator
Approx. 20 sec | 2 or 4
1 x CR123A Lithium battery
– 4°F - +122°F (–20°C - +50°C)
85% max.
Form C (micro switch)
Tamper switch
Pulse Count
Battery
Environment humidity
Operating temperature
WNX-40HW / WNX-40DS / WNX-402G / WNX-40IX
I. INSTALLATION HINTS
X. SPECIFICATIONS
II. DETECTION AREA
PIR Detector
PASSIVE INFRARED DETECTOR
WNX-40HW/WNX-40DS
WNX-402G/WNX-40IX
Avoid curtain, screen, etc. from blocking
detection area.
Eviter les obstacles masquant la zone de
détection (rideau, vitres)
Do not obscure even partially the
detector’s field of view.
Ne pas obscurcir partiellement ou
complètement le champ de vision du
détecteur.
Do not install
outdoors.
Ne pas installer
à l’extérieur.
Do not mount in an
unstable location where
vibrations or shock may
affect the detector.
Ne pas installer sur des
supports instables afin
d’éviter les vibrations et
les chocs pouvant
affecter le détecteur.
TOP VIEW
FEATURES
SIDE VIEW
inches (mm)
inches (mm)
The nix sign indicates prohibition.
Dimensions
Mounting Position
Small animal tolerance applies to animals
0 to 40cm/0 to 16 inches in height
Tamper switch
Selectable pulse count 2 or 4
2/28/2018
59-2712-0
NOTE
Le signe non indique une interdiction.
INSTALLATION INSTRUCTIONS
Avoid direct sunlight.
Eviter le rayonnement solaire direct.
Avoid facing directly to air
conditioners or heating vents.
Eivter la proximité d’air
conditionné, de chauffage, etc.
Avoid vapor or
high humidity that
can cause
condensation.
Eviter la vapeur et
l’humidité pouvant
condenser.
OPTEX INC. (U.S.)
URL: http://www.optexamerica.com
OPTEX DO BRASIL LTDA. (Brazil)
URL: http://www.optex.net/br/es/sec
OPTEX (EUROPE) LTD. / EMEA HQ (U.K.)
URL: http://www.optex-europe.com
OPTEX TECHNOLOGIES B.V. (The Netherlands)
URL: http://www.optex.eu
OPTEX SECURITY SAS (France)
URL: http://www.optex-security.com
OPTEX SECURITY Sp.z o.o. (Poland)
URL: http://www.optex.com.pl
OPTEX PINNACLE INDIA, PVT., LTD. (India)
URL: http://www.optex.net/in/en/sec
OPTEX KOREA CO.,LTD. (Korea)
URL: http://www.optexkorea.com
OPTEX (DONGGUAN) CO.,LTD.
SHANGHAI OFFICE (China)
URL: http://www.optexchina.com
OPTEX (Thailand) CO., LTD. (Thailand)
URL: http://www.optex.net/th/th
Copyright (C) 2016 OPTEX CO.,LTD.
This unit is designed to detect an intruder and activate an alarm control panel.
Being only a part of a complete system, we cannot accept responsibility for
any damages or other consequences resulting from an intrusion.
- 1 -- 4 -
WNX-40HW Honeywell 5800 Series Compatible
WNX-402G 2GIG Compatible
WNX-40DS DSC 433MHz Compatible
WNX-40IX Interlogix 319.5MHz & QOLSYS Compatible
*Product is not produced by, endorsed by, nor is officially associated with
Honeywell, DSC, 2GIG, Interlogix, or QOLSYS.
Install in accordance with the Standard for Installation and Classification of Burglar and Holdup Alarm Systems, UL 681.
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference that may be
received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the Resolution Products, Inc. could void the user’s authority to operate this equipment.
IC NOTICE
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux cnr d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes:
(1) L’appareil ne doit pas produire de brouillage, et (2) L’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
“Honeywell”, “2GIG”, “Interlogix”, “DSC” are trademarks owned by Honeywell International, Inc, Nortek Security & Control LLC, United Technologies Corporation, and Tyco Safety Products Canada LTD, respectively.OP-
TEX Inc. products will function with one of either Honeywell, 2GIG, Interlogix, or DSC systems. However, no OPTEX Inc. product is produced by, endorsed by, nor is officially associated with Honeywell, 2GIG, Interlogix,
DSC.OPTEX Inc. recommends verifying proper enrollment and operation, per control panel installation instructions, at installation.
FCC ID
WNX-40HW/WNX-402G: U5X-RE261
WNX-40DS: U5X-RE361
WNX-40IX: U5X-RE161
IC ID
WNX-40HW/WNX-402G: 8310A-RE261
WNX-40DS: 8310A-RE361
WNX-40IX: 8310A-RE161
7
5 10 15 20 25 30 35 40 ft
0
2.4m 128 01 m0 2 4 6 8 ft
5 10 15 25 30 35 40 ft
6 m
4
2
15
10
5
20 ft
24 6 8 10 12m
4
6 m
0
2
0
5
10
15
20 ft
20
Wall Tamper
VI. FUNCTIONSIII. DESCRIPTION AND OPERATION
IV. MOUNTING VII. TROUBLE SHOOTING AND MAINTENANCE
*Conduct a walk test at least once per year.
ESUACELBABORPMELBORP REMEDY
Loosen fastening screw
and remove cover.
Mount the unit, install a
battery, and enroll the
transmitter.
Replace the cover Select switch for Walk Test
from “ON” to “OFF”.
Fasten cover with fastening
screw.
Conduct a Walk Test.
- 3 -
- 2 -
V. ENROLLING TO CONTROL PANEL
1. LED ON / OFF
The Alarm LED indicator can be switched either “ON” or “OFF”.
2. PULSE COUNT
The Detection Mode can be switched to either “2” or “4” depending on the environmental conditions of
installation.
2: For normal applications.
4: For use in hostile areas where there may be movement of small animals or other objects such as fax
When the “4” is selected, the sensitivity may seem sluggish. Conduct a Walk Test to ensure that the desired
coverage is given.
3. WALK TEST SWITCH
WALK TEST
1) LED lights up when the unit has detected.
2) An alarm signal is output whenever it detects.
NORMAL : Normal Operation (Battery Saving Mode)
1) LED lights up when unit detects and “LED ON” is selected.
2) Once alarm is generated, another alarm will not generate for 2 minutes.
Interlogix:
  Programming/Enrolling
     • Place control panel into enrollment mode
     •Remove battery tab to automatically send entire RF enrollment
sequence, or
     • Open cover to send Tamper Signal
QOLSYS:
Programming/Enrolling
• Place control panel into enrollment mode.
• Remove battery tab to automatically send entire RF enrollment
sequence, or
• Open cover to send Tamper Signal
Honeywell:
 Programming/Enrolling
     • Enroll by placing the panel into wireless enrollment mode
     •Remove battery tab while holding Tamper to automatically
send entire RF enrollment sequence, or
     • Trip (alarm or tamper) 3 times, or
     • Enter the sensors ID number
Enrollment Tips
     • Program as an RF type (Supervised RF)
     • Program as Loop 1
     • Loop 4 = Tamper
    
2GIG:
  Programming/Enrolling
     • Place control panel into enrollment mode
•Remove battery tab while holding tamper to automatically send entire
RF enrollment sequence, or
• Trip (alarm or tamper) 3 times, or
     • Enter the sensors ID number
  Enrollment Tips
     • Confirm Loop 1 is selected
     • Power down the PIR after enrollment to keep panel from mistakenly
double enrolling the sensor.
DSC:
  Programming/Enrolling
     • Place control panel into enrollment mode
     •Remove battery tab to automatically send entire RF enrollment
sequence, or
     • Open cover to send Tamper Signal, or
     • Enter the sensors ID number
Cryptix:
  Programming/Enrolling
     • Place control panel into enrollment mode
     •Remove battery tab to automatically send entire RF enrollment
sequence, or
     • Open cover to send Tamper Signal, or
     • Enter the sensors ID number
Alarm is not activated
although someone is
walking in detection
area.
Unintended activation
(False Alarm)
LED does not light up at
the time of walk test.
Detection area is improper.
Battery is dead.
Battery is dead.
Walk Test switch is OFF.
Conduct a walktest. See Section II.
Change battery.
Change battery.
Turn the Walk Test switch on. See Section VI.
Turn the Walk Test switch on.
Remove the object from the detection area.
Remove the heat sources from the detection area or relocate
the detector.
Walk Test switch is OFF.
Moving object within detection area.
(curtain, wall hanging, etc.)
Temperature of object within area is changing rapidly.
(heater, air conditioning, etc.)
VIII. BATTERY LIFE
IX. OPTIONAL ACCESSORIES
The values indicated are only for reference on each condition. The sensor will send low battery transmissions to the control panel.
CR123A (3V, 1300mAh)
machines or curtains.
(Factory setting)
ON OFF
(Factory setting)
24
(Factory setting)
WALK TEST NORMAL
Alarm trigger per day Battery Life
240 Approx. 7 years
720 Approx. 3 years
Lens
Tamper Knockout
Mounting Knockout
Corner Mounting
Knockout
Corner Mounting
Knockout
Fastening Screw
LED Indicator for
-Warm-up period
-Alarm
TOP VIEW
SIDE VIEW
1.5m 10
5ft
20 30 40 50 60 tf
0
1.5m 510 15 18m
0
5ft
010 20 30 40 50 60 tf
18m15
1050
2.4m
LONG RANGE
(OPTIONAL LENS: FL-60N)
18 x 1.8m (60 x 6ft.)
FA-3
Compact Wall & Ceiling Mount Bracket

This manual suits for next models

3

Other Optex Security Sensor manuals

Optex FitLink User manual

Optex

Optex FitLink User manual

Optex OVS-6000 User manual

Optex

Optex OVS-6000 User manual

Optex VX Shield Series User manual

Optex

Optex VX Shield Series User manual

Optex HX-40 User manual

Optex

Optex HX-40 User manual

Optex OA-EDGE T User manual

Optex

Optex OA-EDGE T User manual

Optex FTN-RRHW User manual

Optex

Optex FTN-RRHW User manual

Optex HX-40 User manual

Optex

Optex HX-40 User manual

Optex X-ZONE User manual

Optex

Optex X-ZONE User manual

Optex WFX-360HW User manual

Optex

Optex WFX-360HW User manual

Optex BX SHIELD Series User manual

Optex

Optex BX SHIELD Series User manual

Optex AX-350DH MK III User manual

Optex

Optex AX-350DH MK III User manual

Optex HX-40RAM User manual

Optex

Optex HX-40RAM User manual

Optex VX-402 User manual

Optex

Optex VX-402 User manual

Optex WX Shield Series User manual

Optex

Optex WX Shield Series User manual

Optex CX-502 User manual

Optex

Optex CX-502 User manual

Optex MX-40QZ User manual

Optex

Optex MX-40QZ User manual

Optex VX-402R User manual

Optex

Optex VX-402R User manual

Optex AX-70TN User manual

Optex

Optex AX-70TN User manual

Optex AX-70TN User manual

Optex

Optex AX-70TN User manual

Optex REDSCAN mini-Pro Series User manual

Optex

Optex REDSCAN mini-Pro Series User manual

Optex FMX-DT-X5 User manual

Optex

Optex FMX-DT-X5 User manual

Optex RXC-RST User manual

Optex

Optex RXC-RST User manual

Optex inSight INS-HX-80N User manual

Optex

Optex inSight INS-HX-80N User manual

Optex QX Infinity Series User manual

Optex

Optex QX Infinity Series User manual

Popular Security Sensor manuals by other brands

SDC MD-31D installation instructions

SDC

SDC MD-31D installation instructions

Aritech VE1120 Series Installation sheet

Aritech

Aritech VE1120 Series Installation sheet

C-LOGIC 610-MD instruction manual

C-LOGIC

C-LOGIC 610-MD instruction manual

Sminn COMPATTA CONTROL Assembly instructions

Sminn

Sminn COMPATTA CONTROL Assembly instructions

Greenlee 2010 instruction manual

Greenlee

Greenlee 2010 instruction manual

Honeywell Eclipse Installing

Honeywell

Honeywell Eclipse Installing

Taco LeakBreaker LBW Series instruction sheet

Taco

Taco LeakBreaker LBW Series instruction sheet

ADEMCO ASC25 Series installation instructions

ADEMCO

ADEMCO ASC25 Series installation instructions

DBI SALA SAFLOCK 2100103 Specific instructions

DBI SALA

DBI SALA SAFLOCK 2100103 Specific instructions

Siemens SITRANS F FUH1010 Series operating instructions

Siemens

Siemens SITRANS F FUH1010 Series operating instructions

Atim Cloud Wireless LoRaWAN ACW/LW8-THX user guide

Atim Cloud Wireless

Atim Cloud Wireless LoRaWAN ACW/LW8-THX user guide

STEINEL IR 180 Information

STEINEL

STEINEL IR 180 Information

Neilsen CT2129 instruction manual

Neilsen

Neilsen CT2129 instruction manual

Elkron IR200 quick start guide

Elkron

Elkron IR200 quick start guide

Honeywell LightSpot LS1000R Installation and operating instructions

Honeywell

Honeywell LightSpot LS1000R Installation and operating instructions

Scott Safety MultiFlame FV-40 Series user guide

Scott Safety

Scott Safety MultiFlame FV-40 Series user guide

Maximum OUT LOOK quick reference

Maximum

Maximum OUT LOOK quick reference

ST X-NUCLEO-IKS02A1 user manual

ST

ST X-NUCLEO-IKS02A1 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.