Hereby, OPTEX declares that the radio equipment type FLX-A-DAM-X5,FLX-A-DAM-X8,and FLX-A-DAM-X9 are in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address: www.optex.net
Microwave emission Frequency and Power
The following list indicates the areas of intended use of the equipment and any known restrictions.
For countries not included in this list, please consult the responsible Spectrum Management Agency.
FLX-A-DAM-X5, FLX-A-DAM-X8, and FLX-A-DAM-X9 also comply with EU radiation exposure limits set forth for an uncontrolled
environment.
This equipment should be installed and operated with minimum distance
20 cm between the radiator & your body.
■
■
■
■
- Compliance
* If the detector cover does not reach
the ceiling, it can be swung up to +5°.
NOTE
- Angle adjustment with bracket
FLX-A-DAM-X5:
FLX-A-DAM-X8:
FLX-A-DAM-X9:
10.525 GHz 15.78 mW e.i.r.p
10.587 GHz 8.93 mW e.i.r.p
9.425 GHz 14.50 mW e.i.r.p
5゚
20゚
20゚
5゚
45゚
45゚
45゚
45゚
Belgium, Denmark, Finland, Germany, Greece, Italy, Luxembourg, The Netherlands, Spain, Sweden, Iceland, Norway, Switzerland
Belgium, France, Germany, Ireland, Luxembourg, The Netherlands, United Kingdom
Austria, Czechia, Estonia, Germany, Slovakia, Turkey, Russia
10.525 GHz:
10.587 GHz:
9.425 GHz:
RE Directive 2014/53/EU
EU & UK contact information
https://navi.optex.net/cert/contact/
OPTEX INC./AMERICAS HQ (U.S.)
www.optexamerica.com
OPTEX (EUROPE) LTD./EMEA HQ (U.K.)
www.optex-europe.com
OPTEX SECURITY B.V.
(The Netherlands)
www.optex-europe.com/nl
OPTEX SECURITY SAS (France)
www.optex-europe.com/fr
OPTEX SECURITY Sp.z o.o. (Poland)
www.optex-europe.com/pl
OPTEX PINNACLE INDIA,
PVT., LTD. (India)
www.optexpinnacle.com
OPTEX KOREA CO.,LTD. (Korea)
www.optexkorea.com
OPTEX (DONGGUAN) CO.,LTD.
SHANGHAI OFFICE (China)
www.optexchina.com
OPTEX (Thailand) CO., LTD. (Thailand)
www.optex.co.th
Copyright (C) 2022 OPTEX CO.,LTD.
OPTEX CO., LTD. (JAPAN)
www.optex.net
17
FLX-A-DAM-X8 also comply with UK radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body.
Hereby, OPTEX declares that the radio equipment type FLX-A-DAM-X8 is in compliance with Radio Equipment Regulations 2017.
The full text of the UK declaration of conformity is available at the following internet address: www.optex.net
■
UK Radio Equipment Regulations 2017
EN 50131-1 Grades and Environmental Class; Security Grade 3, Environmental Class II
Applied Standards; EN 50131-2-2 (FLX-A-AM), EN 50131-2-4 (FLX-A-DAM-X5 and FLX-A-DAM-X8)
Tested and certified by Telefication
larm klass 3, miljö klass II, SSF 1014
PD6662:2017
UL/c-UL listed (FLX-A-AM and FLX-A-DAM-X5)
■
■
■
■
■