manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. ORiNG
  6. •
  7. Switch
  8. •
  9. ORiNG IGS-9122GPM User manual

ORiNG IGS-9122GPM User manual

Quick Installation Guide
Version 1.0
Quick Installation Guide
Introduction
PRINTED ON RECYCLED PAPER
The is a modular managed industrial Ethernet switch with
twelve 10/100/1000Base-T(X) ports and two 100/1000Base-X SFP ports.
The Gigabit ports provide high network throughputs to give your network the
capacity to handle huge workloads. The SFP ports can meet demand for
long-distance data transmission. The switch comes with two modular slots
to provide more Ethernet ports. The modules support hot-swap installation;
therefore, you don’t need to power off the switch when replacing the
module. The switch also supports Ethernet Redundancy protocol, O-Ring
(recovery time < 30ms over 250 units of connection) and MSTP (RSTP/STP
compatible) to protect mission-critical applications from network
interruptions or temporary malfunctions with fast recovery technology. With
a wide operating temperature from -40 C to 75 C, the device can be
managed centrally via Oring’s proprietary Open-Vision platform as well as
via Web-based interfaces, Telnet, and console (CLI). The switch is one of
the most reliable choices for highly-managed and fiber Ethernet
applications.
IGS-9122GPM
oo
Dimension
Panel Layouts
1. Power System LED
2. Power2 LED
3. Ring status LED
4. Fault indicator
5. Power1 LED
6. R.M. (Ring Master) LED
7. Reset button
8. Power input
9. Console port
10. Link/Act LED for SFP port
11. SFP port
12. Link/action LED for Gigabit Ethernet ports
13. Gigabit Ethernet ports
14. Speed LED for Gigabit Ethernet ports
Package Contents
Contents
DIN-rail Kit
CD
IGS-9122GPM
Pictures Number
X1
X1
X1
Front View
The device is shipped with the following items. If any of these items is
missing or damaged, please contact your customer service representative for
assistance.
GIGABIT
INDUSTRIAL
SWITCH
Industrial Modular Managed Gigabit
Switch
QIG
Console Cable X1
X1
8
4
5
6
Rear View
21
1. Wall-mount screw holes
2. Din-rail screw holes
Installation
Step 1:
Step 2:
Slant the switch and screw the Din-rail kit onto the back of the switch, right in the
middle of the back panel.
Slide the switch onto a DIN-rail from the Din-rail kit and make sure the switch clicks
into the rail firmly.
DIN-rail Installation
QIG IGS-9122GPM 1907-2-29-IGS9122GPM-1.0
Mechanical Loading:
Circuit Overloading:
Mounting of the equipment in the rack should be such that
a hazardous condition is not achieved due to uneven mechanical loading.
Consideration should be given to the connection of the equipment
to the supply circuit and the effect that overloading of the circuits might have on
overcurrent protection and supply wiring. Appropriate consideration of equipment
nameplate ratings should be used when addressing this concern.
Network Connection
The switch provides standard Ethernet ports. According to the link type, the switch uses
CAT 3, 4, 5,5e UTP cables to connect to any other network devices (PCs, servers,
switches, routers, or hubs). Please refer to the following table for cable specifications.
Cable Types and Specifications:
14
10
Preparation
Before you begin installing the switch, make sure you have all of the package
contents available and a PC with Microsoft Internet Explorer 6.0 or later, for
using web-based system management tools.
Elevated Operating Ambient:
Reduced Air Flow:
If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be
greater than room ambient. Therefore, consideration should be given to
installing the equipment in an environment compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is
not compromised.
Safety & Warnings
1
2
3
7
9
11
12
13
1
1
1
Cable Type Max. Length Connector
10BASE-T Cat. 3, 4, 5 100-ohm UTP 100 m (328 ft) RJ-45
100BASE-TX Cat. 5 100-ohm UTP UTP 100 m (328 ft) RJ-45
1000BASE-T Cat. 5 / Cat. 5e 100-ohm UTP UTP 100 m (328 ft) RJ-45
For pin assignments for different types of cables, please refer to the following
tables.
10/100 Base-T(X) MDI/MDI-X
Pin Number MDI port MDI-X port
1TD+(transmit)RD+(receive)
2TD-(transmit)RD-(receive)
3 RD+(receive) TD+(transmit)
4NotusedNotused
5NotusedNotused
6 RD-(receive) TD-(transmit)
7NotusedNotused
8NotusedNotused
Note: “+” and “-” signs represent the polarity of the wires that make up each
wire pair.
1000B ase-T MDI/MDI-X
Pin Number MDI port MDI-X port
1BI_DA+BI_DB+
2 BI_DA- BI_DB-
3 BI_DB+ BI_DA+
4 BI_DC+ BI_DD+
5 BI_DC- BI_DD-
6 BI_DB- BI_DA-
7 BI_DD+ BI_DC+
8 BI_DD- BI_DC-
1000Base-T RJ-45 Port
Pin Number Assignment
1BI_DA+
2BI_DA-
3BI_DB+
4BI_DC+
5BI_DC-
6BI_DB-
7BI_DD+
8BI_DD-
10/100 Base-T(X) RJ-45 Port
Pin Number Assignments
1TD+
2TD-
3RD+
4 Not used
5 Not used
6RD-
7 Not used
8 Not used
IGS-9122GPM
QIG Quick Installation Guide
PRINTED ON RECYCLED PAPER
Quick Installation Guide
Resetting
To reboot the switch, press the button for 2-3 seconds.
To restore the switch configurations back to the factory defaults, press the button for 5 seconds.
Reset
Reset
GIGABIT
INDUSTRIAL
SWITCH
To connect the console port to an external management device, you need an RJ-45 to
DB-9 cable, which is also supplied in the package. Below is the console port pin
assignment information.
Console Port Pin Definition
PC (male) pin assignment RS-232 with DB9 (female) pin
assig nment (RJ45-DB9 cable) RJ45 pi n assignment
PIN#2 RxD PIN#2 RxD PIN#2 RxD
PIN#3TxD PIN#3TxD PIN#3TxD
PIN#5 GND PIN#5 GND PIN#5 GND
Wiring
The switch supports dual redundant power supplies, Power Supply1
(PWR1) and Power Supply 2 (PWR2). The connections for PWR1,
PWR2 and the RELAY are located on the terminal block.
Insert the negative/positive wires into the V-/V+ terminals,
respectively.
To keep the DC wires from pulling loose, use a small flat-
blade screwdriver to tighten the wire-clamp screws on the front of the
terminal block connector.
STEP 1:
STEP 2:
PWR-1PWR-2
1A@24V
V2-V2+ V1-V1+
Fault
Power inputs
The two sets of relay contacts of the 6-pin terminal block connector are used to detect user-
configured events. The two wires attached to the fault contacts form an open circuit when a
user-configured when an event is triggered. If a user-configured event does not occur, the
fault circuit remains closed.
Relay contact
Configurations
After installing the switch, the green power LED should turn on. Please refer to
the following tablet for LED indication.
1. Launch the Internet Explorer and type in IP address of the switch. The default static IP address is
192.168.10.1
2. Log in with default user name and password (both are ). After logging in, you should see
the following screen. For more information on configurations, please refer to the user manual. For
information on operating the switch using ORing’s Open-Vision management utility, please go to
ORing website.
admin
Follow the steps to set up the switch:
Power
Redundant Input power
Power consumption(Typ.)
Dual DC inputs. 12-48VDC on 6-pin terminal block
21 watts
Overload current protection Present
Physical Characteristic
Enclosure IP-30
Dimension(WxDxH) 200 (W) x 150 (D) x 150.8 (H) mm (7.87x5.9x5.9 inch)
RS-232 Serial Console Port
Switch Properties
Switch latency: 7 us
Switch bandwidth: 52Gbps
Max. Number of Available VLANs: 4095
VLAN ID Range :VID 1 to 4094
IGMP multicast groups: 128 for each VLAN
Port rate limiting: User Define
Security Features
Device Binding security feature
Enable/disable ports, MAC based port security
Port based network access control (802.1x)
Single 802.1x and Multiple 802.1x
MAC-based authentication
QoS assignment
Guest VLAN
MACaddresslimit
TACACS+
VLAN (802.1q) to segregate and secure network traffic
Radius centralized password management
SNMPv3 encrypted authentication and access security
Https / SSH enhance network security
Web and CLI authentication and authorization
IP source guard
Software Features
IEEE 1588v2 clock synchronization
IEEE 802.1D Bridge, auto MAC address learning/aging and MAC address (static)
Multiple Registration Protocol (MRP)
MSTP (RSTP/STP compatible)
Redundant Ring (O-Ring) with recovery time less than 30ms over 250 units
TOS/Diffserv supported
Quality of Service (802.1p) for real-time traffic
VLAN (802.1Q) with VLAN tagging and GVRP supported
IGMP Snooping for multicast filtering
IP-based bandwidth management
Application-based QoS management
Port configuration, status, statistics, monitoring, security
DHCP Server / Client support
DHCP Relay
SMTP Client
Modbus TCP
DNS client proxy
NTP server
Network Redundancy O-Ring, O-chain, MRP, Fast Recovery, MSTP (RSTP/ STP compatible)
RS-232 in RJ45 connector with console cable. 115200bps, 8, N, 1 (support DBU-01 backup unit)
Weig ht (g ) 3,042g(without module)
Jumbo frame Up to 9.6K Bytes
Weig ht (g ) 710 g 740 g722 g 735 g 735 g 740 g
Environmental
-40to85C(-40to185F)
oo
Storage Temperature
-40to75C(-40to167F)
oo
Operating Temperature
5% to 95% Non-condensingOperating Humidity
Regulatory Approvals
FCC Part 15, CISPR (EN55022) class AEMI
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge),EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11
EMS
EN50121-4(N50121-1)
Railway
Warranty
5years
ORing Industrial Networking Corp.
Copyright© 2016 ORing
All rights reserved.
TEL: +886-2-2218-1066
FAX: +886-2-2218-1014
Website: www.oring-networking.com
E-mail: [email protected]
Specifications
ORing Switch Model IGS-9122GPM
Physical Ports
Technology
Ethernet Standards
IEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-TX and 100Base-FX
IEEE 802.3z for 1000Base-X
IEEE 802.3ab for 1000Base-T
IEEE 802.3ad for LACP (Link Aggregation Control Protocol)
IEEE 802.3x for Flow control
IEEE 802.1D for STP (Spanning Tree Protocol)
IEEE 802.1p for COS (Class of service)
IEEE 802.1Q for VLAN Tagging
IEEE 802.1w for RSTP (Rapid Spanning Tree Protocol
IEEE 802.1s for MSTP (Multiple Spanning Tree Protocol)
IEEE 802.1x for Authentication
IEEE 802.1AB for LLDP (Link Layer Discovery Protocol)
10/100/1000Base-T(X) Ports
in RJ45 Auto MDI/MDIX
MAC Table 8K
Priority Queues 8
Processing Store-and-Forward
12
100/1000Base-X with SFP port 2
QIG
Version 1.0
Industrial Modular Managed Gigabit
Switch
LED Color Status Description
PWR Green On System power on
PW1 Green On Power module 1 activate d
PW2 Green On Power module 2 activate d
R.M Green On System operated in O-Ring Master mode
On System operated in O-Ring mode
Ring Green
Blinking Ring structure is broken
Faul t Amb er On Erro rs occur (power failure or ports disconnected)
10/100/ 1000Base-T (X) Fast Ethernet p orts
On Port is Linked
LNK/ACT Green Blinking Transmitting data
Green On Port in 1000Mbps speed
Amber On Port in 100Mbps speed
SPEED
(Dual color)
Green/Amb er Off Port in 10Mbps speed
SFP ports
On Port is linked
LNK/ACT Green
Blinking Transmitting data
Module Slot Number 2 (support 4x1G combo / 4x100Mbps Fiber module)
Fault Contact
Relay Relayoutputtocarrycapacityof1Aat24VDC
MTBF
540, 456 hrs
IGS-9122GPM
IGS-9122GPM

Other manuals for IGS-9122GPM

1

Other ORiNG Switch manuals

ORiNG IGPS-9084GP User manual

ORiNG

ORiNG IGPS-9084GP User manual

ORiNG TPS-3882GT-M12-BP1 User manual

ORiNG

ORiNG TPS-3882GT-M12-BP1 User manual

ORiNG IGPS-1042GPA User manual

ORiNG

ORiNG IGPS-1042GPA User manual

ORiNG IGS-3044GC User manual

ORiNG

ORiNG IGS-3044GC User manual

ORiNG IGPS-9822DGP+ User manual

ORiNG

ORiNG IGPS-9822DGP+ User manual

ORiNG TPS-141TX-M12 Series User manual

ORiNG

ORiNG TPS-141TX-M12 Series User manual

ORiNG Thunder Series User manual

ORiNG

ORiNG Thunder Series User manual

ORiNG IPS-1080-24V User manual

ORiNG

ORiNG IPS-1080-24V User manual

ORiNG IGPS-1411GTPA User manual

ORiNG

ORiNG IGPS-1411GTPA User manual

ORiNG TRGPS-9084TG-M12X-BP2-MV User manual

ORiNG

ORiNG TRGPS-9084TG-M12X-BP2-MV User manual

ORiNG TPS-1080-M12 User manual

ORiNG

ORiNG TPS-1080-M12 User manual

ORiNG IES-2060 Series User manual

ORiNG

ORiNG IES-2060 Series User manual

ORiNG IGPS-1080A User manual

ORiNG

ORiNG IGPS-1080A User manual

ORiNG TES-3080-M12 Series User manual

ORiNG

ORiNG TES-3080-M12 Series User manual

ORiNG TGXPS-1080-M12-24V Series User manual

ORiNG

ORiNG TGXPS-1080-M12-24V Series User manual

ORiNG IES-1050A User manual

ORiNG

ORiNG IES-1050A User manual

ORiNG DGS-9168GP-SS-AIO_S User manual

ORiNG

ORiNG DGS-9168GP-SS-AIO_S User manual

ORiNG TES-3080-M12 Series User manual

ORiNG

ORiNG TES-3080-M12 Series User manual

ORiNG IES-2050 User manual

ORiNG

ORiNG IES-2050 User manual

ORiNG IGS-9084GP-FB2-SS User manual

ORiNG

ORiNG IGS-9084GP-FB2-SS User manual

ORiNG IGS-9084GP-LA User manual

ORiNG

ORiNG IGS-9084GP-LA User manual

ORiNG Transporter Series User manual

ORiNG

ORiNG Transporter Series User manual

ORiNG RGS-7244GP User manual

ORiNG

ORiNG RGS-7244GP User manual

ORiNG IES-180-L User manual

ORiNG

ORiNG IES-180-L User manual

Popular Switch manuals by other brands

Lenovo ThinkSystem NE25720 installation guide

Lenovo

Lenovo ThinkSystem NE25720 installation guide

MORLEY ABYES manual

MORLEY

MORLEY ABYES manual

TRENDnet TEG-S16R - DATA SHEETS Quick installation guide

TRENDnet

TRENDnet TEG-S16R - DATA SHEETS Quick installation guide

Emerson TARTARINI V/31-2-AP-E Series instruction manual

Emerson

Emerson TARTARINI V/31-2-AP-E Series instruction manual

3Com 3C16670 - LinkBuilder FMS II Hub Configuration guide

3Com

3Com 3C16670 - LinkBuilder FMS II Hub Configuration guide

Crestron infiNET CLW-SLVS1RF Operation guide

Crestron

Crestron infiNET CLW-SLVS1RF Operation guide

Hama USB 3.0 Hub 1:4 Operating	 instruction

Hama

Hama USB 3.0 Hub 1:4 Operating instruction

Crestron DM-MD8X1-4K-C Supplemental guide

Crestron

Crestron DM-MD8X1-4K-C Supplemental guide

Crystal Image Technologies LCDK2003 user manual

Crystal Image Technologies

Crystal Image Technologies LCDK2003 user manual

Kobold NV operating instructions

Kobold

Kobold NV operating instructions

Digicom 8E4090 brochure

Digicom

Digicom 8E4090 brochure

Ocean Matrix OMX-DEM100 instruction manual

Ocean Matrix

Ocean Matrix OMX-DEM100 instruction manual

Goobay 60811 manual

Goobay

Goobay 60811 manual

Extron electronics System 8 Plus installation instructions

Extron electronics

Extron electronics System 8 Plus installation instructions

ATEN Slideaway CL5708 user manual

ATEN

ATEN Slideaway CL5708 user manual

Manhattan 162272 instructions

Manhattan

Manhattan 162272 instructions

Lenovo RackSwitch G8296 installation guide

Lenovo

Lenovo RackSwitch G8296 installation guide

Hawking CS112U Specifications

Hawking

Hawking CS112U Specifications

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.