manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Panasonic
  6. •
  7. Control Unit
  8. •
  9. Panasonic S-LINK V SL-VMC1 User manual

Panasonic S-LINK V SL-VMC1 User manual

●Never use this product in a device for personnel protection.
●In case of using devices for personnel protection, use products which
meet laws and standards, such as OSHA, ANSI or IEC etc., for person-
nel protection applicable in each region or country.
●Before touching this product, remove any electrostatic charge that may
be present on your body. There is a danger of this product getting dam-
aged due to the electrostatic charge.
CAUTIONS
3
In case of designing a board, take care of the bottom of this product that is
the area of being prohibited from mounting parts, mounting of the parts kit,
and pattern width.
●This product has been developed / produced for industrial use only.
●This product is not equipped with a short-circuit protection circuit. Use a
power supply having a short-circuit protection function (e.g. fuse, etc.).
●Verify that the supply voltage variation is within the rating. Also, check
the voltage variation at the end terminal of the transmission route, since
voltage drop occurs depending on the diameter or the length of the
transmission cable.
●If power is supplied from a commercial switching regulator, ensure that
the frame ground (F.G.) terminal of the power supply is connected to an
actual ground.
●Do not use during the initial transient time after the power supply is
switched ON. Furthermore, transmission is not possible when the system is
in Busy state (during switching ON of the power supply or system setting.)
●Make sure to use an isolation transformer for the DC power supply. If an
auto-transformer (single winding transformer) is used, this product or the
power supply may get damaged.
●In case a surge is generated in the power supply used, connect a surge
absorber to the supply and absorb the surge.
●Solder terminals at 260°C or less within 10 seconds.
●Do not run the wires together with high-voltage lines or power lines or put
them in the same raceway. This can cause malfunction due to induction.
●Make sure to carry out wiring in the power supply OFF condition.
●Take care that wrong wiring will damage the product.
●In order to reduce noise, make the wiring as short as possible.
●In case noise generating equipment (switching regulator, inverter motor,
etc.) is used in the vicinity of this product, connect the frame ground (F.G.)
terminal of the equipment to an actual ground.
●This product does not have a dust-proof or water-proof construction. Do
not use it in a place having excessive vapor, dust, etc.
●Take care that the product does not come in contact with water, chemi-
cals or organic solvents, such as thinner, etc. Furthermore, do not use it
in an environment having corrosive gas.
●Do not use the product in places where the ambient temperature or the
humidity exceeds the specications.
●Do not touch this product while operation since there are some parts
whose temperatures become high.
●For details of this product, refer to “Product Specications” of the product.
For the “Product Specications” of this product, contact our nearest
sales ofce.
●Please refer to the "S-LINK V User's Manual" for details of the entire
S-LINK V system.
SPECIFICATIONS
1
Notes: 1) 24V DC and 5V DC are insulated.
2) The current consumption value is the total of the maximum current value (D-G line
only) supplied to the S-LINK V I/O units and the current consumption value of the
S-LINK V control module.
3) Validity (valid or invalid) of input interruption can be set for every point. The inter-
ruption condition (ON → OFF or OFF → ON), however, should be set in units of
32 points. If the input change interruption signal and the error occurrence interrup-
tion signal are output at the same time, the priority will be given to the error occur-
rence interruption signal.
4) Values of control module single body are shown in these areas. To mount this
product on your device, these values may be subject to change so that the values
can be optimum for both the control module and your device.
Description
S-LINK V control module
Item
Model No.
SL-VMC1
Supply voltage
(Note 1)
[S-LINK V system side] 24V DC
+10
-
5
%
[Control module side] 5V DC±5%
Current consumption [24V DC] 60mA or less (Note 2)
[5V DC] 200mA or less
Transmission speed A mode: 110kbps, B mode: 27.5kbps, C mode: 6.9kbps
Connection method “T” branch connection or multi-drop connection
I/O points Max. 512 points (Using DIP switches, in increments / decre-
ments of 32 points is also possible.)
Connectable nodes Max. 256 nodes
Transmission distance
A mode: max. 50m, B mode: max. 200m, C mode: max. 800m
Total cable length
A mode: 100m or less, B mode: 400m or less, C mode: 1,600m or less
Suitable
transmission cable
Exclusive 4-core at cable (0.5mm2) or
4-core VCTF cable (non-shield) conductor cross section of
0.3 to 2.0mm2
Specications for
CPU side
Address occupation:
256 bytes (including area not used) from the specied address
Address specication:
Specied by the CS (chip selection signal) using the external logic
Data bus width: 8 bits
Interruption function
(Note 3)
When the input is changed, or when an error occurs
[Validity (valid or invalid) of interruption can be set.]
Ambient temperature
(Note 4) 0 to +55°C (No dew condensation), Storage: -20 to +70°C
Ambient humidity
(Note 4) 20 to 85% RH, Storage: 20 to 85% RH
Weight Approx. 20g
Accessory Parts kit: 1 set (refer to “ PARTS KIT.”)
PARTS KIT
2
●The following parts are attached to this product. Make sure to check
those before use.
Common mode lter: 1 pc. Diode: 1 pc.
Ceramic capacitor (blue): 2 pcs. Surge absorber (black): 1 pc.
Poly switch: 2 pcs. Aluminum electrolytic capacitor:
1 pc.
INSTRUCTION MANUAL
Flexible Wire-saving System S-LINK V
S-LINK V Control Module SL-VMC1
MJE-SLVMC1 No.0060-14V
Thank you very much for purchasing Panasonic products.
Please read this Instruction Manual carefully and thoroughly for the correct
and optimum use of this product.
Kindly keep this manual in a convenient place for quick reference.
TERMINAL LAYOUT DRAWING
4
Top view
16 15 14 13 12 11 10 9 8 7 6 4 25 3 1
17 18 19 20 21 22 23 24 25 26 27 29 3128 30 32
Pin No.
Pin No. Name Description
1S-LINK V-24V Opration power for S-LINK V side
2 N.C. Not connected
3 D7
Data I/O
4 D6
5 D5
6 D4
7 D3
8 D2
9 D1
10 D0
11 *RESET Reset input
12 *RD Read input
13 *WAT Wait output
14 *WR Write input
15 *CS Chip selection input
16 GND Grounding terminal for control module side
17 VDD Operation power for control module side
18 SEND Transmission indicator output
19 A0
Address input
20 A1
21 A2
22 A3
23 A4
24 A5
25 A6
26 A7
27 *INT S-LINK V interruption output
28 *READY S-LINK V READY output
29 *24V MON. S-LINK V supply voltage detection output
30 N.C. Not connected
31 S-LINK V-D D of S-LINK V side
32 S-LINK V-G G of S-LINK V side and operation power of 0V
DIMENSIONS (Unit: mm)
6
54
37
3.411±1
Electronic component
mounting area
4.37
15 × 2.54 = 38.1
0.635
2.54
16 × 2.54 = 40.64
33
2
No.1 No.16
No.17
No.32
0.635
INTENDED PRODUCTS FOR CE MARKING
5
●
●
The models listed under “ SPECIFICATIONS” come with CE
Marking.
As for all other models, please contact our office.
Contact for CE
<Until June 30 ,2013>
Panasonic Electric Works Europe AG
Rudolf-Diesel-Ring 2, D-83607 Holzkirchen, Germany
<From July 1 ,2013>
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany
http://panasonic.net/id/pidsx/global
Overseas Sales Division (Head Ofce)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
For sales network, please visit our website.
PRINTED IN JAPAN © Panasonic Industrial Devices SUNX Co., Ltd. 2017

Other Panasonic Control Unit manuals

Panasonic CF-BAS04GU User manual

Panasonic

Panasonic CF-BAS04GU User manual

Panasonic UJ20 Series User manual

Panasonic

Panasonic UJ20 Series User manual

Panasonic AK-HCU250P User manual

Panasonic

Panasonic AK-HCU250P User manual

Panasonic CA-RC3000EU User manual

Panasonic

Panasonic CA-RC3000EU User manual

Panasonic SF-C14EX-01 User manual

Panasonic

Panasonic SF-C14EX-01 User manual

Panasonic CF-BAC04GU User manual

Panasonic

Panasonic CF-BAC04GU User manual

Panasonic FP7 Series User manual

Panasonic

Panasonic FP7 Series User manual

Panasonic VBHN240SE10 User manual

Panasonic

Panasonic VBHN240SE10 User manual

Panasonic HIT VBHN340SA17E User manual

Panasonic

Panasonic HIT VBHN340SA17E User manual

Panasonic CF-BAC02GU User manual

Panasonic

Panasonic CF-BAC02GU User manual

Panasonic AJ-WM50E User manual

Panasonic

Panasonic AJ-WM50E User manual

Panasonic CARICAM AU-VSHL2G User manual

Panasonic

Panasonic CARICAM AU-VSHL2G User manual

Panasonic FZ-VCN55 Series User manual

Panasonic

Panasonic FZ-VCN55 Series User manual

Panasonic PAN1322-SPP User manual

Panasonic

Panasonic PAN1322-SPP User manual

Panasonic PAN1026A Owner's manual

Panasonic

Panasonic PAN1026A Owner's manual

Panasonic WX-CC411BP User manual

Panasonic

Panasonic WX-CC411BP User manual

Panasonic CATU9000U - AV CTRL AMP User manual

Panasonic

Panasonic CATU9000U - AV CTRL AMP User manual

Panasonic GP-KS162CUDE User manual

Panasonic

Panasonic GP-KS162CUDE User manual

Panasonic GPKS162CUD - CONTROL UNIT User manual

Panasonic

Panasonic GPKS162CUD - CONTROL UNIT User manual

Panasonic SF-C21 User manual

Panasonic

Panasonic SF-C21 User manual

Panasonic KX-TD500 User manual

Panasonic

Panasonic KX-TD500 User manual

Panasonic PAN301 Series Quick setup guide

Panasonic

Panasonic PAN301 Series Quick setup guide

Panasonic AK-MSU1000G User manual

Panasonic

Panasonic AK-MSU1000G User manual

Panasonic PAN4620 User manual

Panasonic

Panasonic PAN4620 User manual

Popular Control Unit manuals by other brands

DMP Electronics 714 installation guide

DMP Electronics

DMP Electronics 714 installation guide

IFM AC3222 operating instructions

IFM

IFM AC3222 operating instructions

Kaysun KWF-140 HT ACS owner's manual

Kaysun

Kaysun KWF-140 HT ACS owner's manual

Nibe MODBUS 40 Installer manual

Nibe

Nibe MODBUS 40 Installer manual

National Instruments SCXI-1521 user manual

National Instruments

National Instruments SCXI-1521 user manual

Allmatic B1EE ERMES2 Manual for installation

Allmatic

Allmatic B1EE ERMES2 Manual for installation

SCIENCE LCTA quick start guide

SCIENCE

SCIENCE LCTA quick start guide

Pfeiffer Vacuum RVG 050 C operating instructions

Pfeiffer Vacuum

Pfeiffer Vacuum RVG 050 C operating instructions

Solera R24R/3 Instructions for use and safety

Solera

Solera R24R/3 Instructions for use and safety

urmet domus 1051/020 quick start guide

urmet domus

urmet domus 1051/020 quick start guide

FW Murphy M-VIEW J1939 Series user manual

FW Murphy

FW Murphy M-VIEW J1939 Series user manual

Trenz Electronic TE0808 Schematics

Trenz Electronic

Trenz Electronic TE0808 Schematics

Texas Instruments TPS2388EVM-612 user guide

Texas Instruments

Texas Instruments TPS2388EVM-612 user guide

GEM R90 operating instructions

GEM

GEM R90 operating instructions

Contrive Quad manual

Contrive

Contrive Quad manual

Amphenol SGX SNSORTECH PS1-O3-5-MOD Data Sheet / Manual

Amphenol

Amphenol SGX SNSORTECH PS1-O3-5-MOD Data Sheet / Manual

EKE-Electronics EKE-Trainnet MVB2791B Technical manual

EKE-Electronics

EKE-Electronics EKE-Trainnet MVB2791B Technical manual

Basalte ASANO N3 installation manual

Basalte

Basalte ASANO N3 installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.